PULSEOXIMETRYThe noninvasive measurement of arterial oxygen saturation (SpO2) by pulse oximetry has become a standard of care. In addition to oxygen saturation values, many pulse oximeters display a photoelectric plethysmographic waveform, which reflects a combination of volume and flow changes in skin microcirculation.
Plethysmographic wave displayed is highly processed and filtered signal (Inverted, autocentered, autogained, and after a bandpass filtering.
Prof.Dr.O.Ferrer-Roca, 2015
ABP versus PPG
• Utility of the Photoplethysmogram in Circulatory Monitoring
• Anesthesiology. 2008;108(5):950-958. doi:10.1097/ALN.0b013e31816c89e1
Photoplethysmography
Arterial blood pressure
Prof.Dr.O.Ferrer-Roca, 2015
Digital Pulse Analysis (DPA) is the next evolution in pulse wave velocity (PWV), and is based on the measurement of reflected infrared light (IR).
At a frequency of 805 nm, both oxygenated and deoxygenated blood have the same absorption, thereby ensuring accuracy based on blood flow alone.
In fact only IR signal at 940 nm is presented in the PPGs becauseIt is much more stable in time if compared with the Red signal at 660 nm that is more susceptible of changes in oxygen saturation.
PI (perfussion index) = (AC pulsating IR signal/ AD non-pulsating IR signal ) x 100 %AC= Alternate curve componentDC= Direct curve component (venousmovement = right atrial contraction + ventilation )
Prof.Dr.O.Ferrer-Roca, 2015
Clasical Pulseoxymeter
Prof.Dr.O.Ferrer-Roca, 2015
PPG analysis. I.- FFT (frequency domain)
Frequencies of the Autonomic Nervous System:1.- VLF (very low frequency) 0.0033-0.04 Hz2.- LF (low frequency) Mayer waves 0.04-0.15 Hz3.- HF (high frequency) Vagus Nerve 0.15-0.4 HzSympathetic predominance
LF norm = LF/LF+HFParasympathetic predominance
HF norm = HF/ LF+HF
Prof.Dr.O.Ferrer-Roca, 2015
PPG analysis. II.- Time domain
Prof.Dr.O.Ferrer-Roca, 2015
HRV = Heart rate variabilityvaluable indicator of phrophylactic cardiovascular interventions
SD1= Short term beat-to-beat variabilitySD2= Long term beat-to-beat variability
x= HHI or RRI sequencesVar= variance of sequencesSDNN= SD of HHI or RRI
Selvaraj, N.; Jaryal, A.; Santhosh, J.; Deepak, K.K.; Anand, S. Assessment of heart rate variability derived from finger-tip photoplethysmography as compared to electrocardiography. J. Med. Eng. Tech. 2008, 32, 479-484.
PRV= Pulse rate variabilitynow is used from PPG
Prof.Dr.O.Ferrer-Roca, 2015
Healthy CV patients have a well defined “dicrotic wave” in the diastolic phase at D, whereas 98% of overt arteriosclerotic patients had significant decrease or disappearance of the wave
Elements of PTG (Systolic Phase)1. S (Starting Point)Starting point of systolic phase of arterial pulse-wave. Aortic valve opens and the blood of the LV is ejected into aorta.2. P (Percussion Wave) Wave caused from LV ejection that increases the blood volume within artery.Higher point means stronger LV ejection and higher compliance oflarger artery.3. T (Tidal Wave)Reflected wave from the small artery. Higher point means contraction and stiffness of small artery.4. C (Incisura)End-point of systolic phase, then aortic valve is closed.Less drop from pulse height (PH) means larger resistance (arterialcontraction & tension).
Prof.Dr.O.Ferrer-Roca, 2015
Second peak value
Prof.Dr.O.Ferrer-Roca, 2015
Second derivative APG wave
Prof.Dr.O.Ferrer-Roca, 2015
Second derivative APG wave
Prof.Dr.O.Ferrer-Roca, 2015
Differences of sensitivity
Prof.Dr.O.Ferrer-Roca, 2015
Respiratory frequency
Prof.Dr.O.Ferrer-Roca, 2015
LVED= Left Ventricular End Diastolic Pressure
Capable to indicate and grade CHF = Chronic Heart Failure
Prof.Dr.O.Ferrer-Roca, 2015
Comprensive measuring
Prof.Dr.O.Ferrer-Roca, 2015
Compressive reporting
Prof.Dr.O.Ferrer-Roca, 2015
Report
Prof.Dr.O.Ferrer-Roca, 2015
Now everything is available 24h/day• H2O = Humanization of
Healthcare• EAROMICS with PPG from the
ear• Costumized and hack4health
Oxirate ®
Flip ®Ear-o-Smart ®
Prof.Dr.O.Ferrer-Roca, 2015
Extended to GSR & EDA
GSR= Galvanic Skin ResponseEDA= Electrodermal Activity
Prof.Dr.O.Ferrer-Roca, 2015
Extended to EEG
Prof.Dr.O.Ferrer-Roca, 2015
Extended to eating habits
Prof.Dr.O.Ferrer-Roca, 2015
Extended to GlucosaeNIR glucometer by Arduino
InGaAs photodiode, 8 LEDs(2 x Green, 2 x NIR @ 1550nm, 1 IR @ 960nm, 1 Red) an Atmega328p, and the circuits required to run those. Also it contains a small LiPo in order to be able to test, or take training data. Two separate circuit boards and the ADC is channeled through an MCP3421 and then i2c goes across a connector at the bottom which also supplies the regulated 3.3V
Prof.Dr.O.Ferrer-Roca, 2015
4P (preventive-pervasive-proactive-personalized)
DIY data HSD (health small data)