Top Banner
3-STAR HOTEL DESIGN INCORPORATING EARTHQUAKE RESISTANT FEATURES PRESENTED BY: GROUP EAGLES PARINAY SINGHAL AVISHA VERMA DEVENDRA SAHU VAISHALI SALVE VASKAR PYNE YASHITA SINGH JADHON JALAJ JAIN SWARNABHA MANDAL ADITYA SINGH RISHI GARHWAL
18
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Eagles

3-STAR HOTEL DESIGN INCORPORATING

EARTHQUAKE RESISTANT FEATURES

PRESENTED BY: GROUP EAGLES

PARINAY SINGHAL AVISHA VERMA

DEVENDRA SAHU VAISHALI SALVE

VASKAR PYNE YASHITA SINGH JADHON

JALAJ JAIN SWARNABHA MANDAL

ADITYA SINGH

RISHI GARHWAL

Page 2: Eagles

DERIVATION OF FORM

AND CONCEPT

Key features Form is stable at the centre

Void is provided at the centre act as a connectivity space in the building

Central lobby with porch (double height)

The built up area combines of four built masses (legs) in different directions

The floors above the 3rd storey form separate units creating two major open spaces in between the form.

CONCEPTUAL FORM

MODIFICATION

FINAL BUILT-UP FORM

Page 3: Eagles

JUSTIFICATION OF FORM & STABILITY

Volume- void ratio is negligible

Architecturally, the form remains as one single unit but structurally it is divided into two parts so that at the time of earthquake shaking of the building occurs uniformly at all parts

The floors at the bottom acts as solid base for the stability of the building.

Page 4: Eagles

SITE PLAN Total site area : 6000 SqM

Built-up area : 19800 SQM

Ground coverage : 50%

Achieved FAR : 3.25

Total no. Of floors : 9

Total height

BUILT-UP AREA

MAIN ENTRANCE

TO THE SITE

SERVICE ENTRANCE

Page 5: Eagles

Area of 1-3 floors : 2360 X 3 = 7080

Area of 4-9 floors : 2120 X 6 = 12720

Total area : 19800 SQM

Total number of rooms : 280

Floor to floor height : 3.25 m

AREA CALCULATION

Page 6: Eagles

GROUND FLOOR PLAN

SERVICE ROOMS

KITCHEN

BANQUET HALL

ENTRANCE

RESTAURANT

ENTRANCE

ENTRANCE LOBBY

(DOUBLE HEIGHT)

Page 7: Eagles

FIRST FLOOR PLAN

BANQUET HALL

CONFERENCE HALLS

KITCHEN

SERVICE AREA

LOBBYRESTAURANT

Page 8: Eagles

FLOOR PLANS

8TH FLOOR

4TH AND 5TH FLOOR3TH FLOOR

5th AND 6TH FLOOR

Page 9: Eagles

9TH FLOOR PLAN

GYM

SWIMMING POOL

RESTAURANT

SPA

Page 10: Eagles

STRUCTURAL ANALYSIS

Page 11: Eagles

STUCTURAL PLAN

STUCTURAL PLAN ( 1ST TO 3RD FLOOR)

Page 12: Eagles

STUCTURAL PLAN (4TH TO 9TH FLOOR)

STUCTURAL PLAN

Page 13: Eagles

EARTHQUAKE RESISTANT DESIGN

(STRUCTURAL DETAILS)

Page 14: Eagles

EARTHQUAKE RESISTANT DESIGN

(STRUCTURAL DETAILS)

Page 15: Eagles

STRUCTURAL

DETAILSSEISMIC BANDS

Page 16: Eagles

RELATED

VIEWS

Page 17: Eagles

VIEW AS SEEN FROM BACK

SIDE (POOL SIDE)

RELATED VIEWS

Page 18: Eagles

THANK YOU