Top Banner
E97-110: Small Angle GDH Experimental Status Report Vincent Sulkosky Massachusetts Institute of Technology Hall A Collaboration Meeting December 15 th , 2011
27

E97-110: Small Angle GDH Experimental Status Report

Feb 24, 2016

Download

Documents

Jay Al Badri

E97-110: Small Angle GDH Experimental Status Report. Vincent Sulkosky Massachusetts Institute of Technology Hall A Collaboration Meeting December 15 th , 2011. Motivation. - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: E97-110:  Small Angle GDH Experimental Status Report

E97-110: Small Angle GDHExperimental Status Report

Vincent SulkoskyMassachusetts Institute of Technology

Hall A Collaboration MeetingDecember 15th, 2011

Page 2: E97-110:  Small Angle GDH Experimental Status Report

MotivationPrecision measurement of the moments of spin

structure functions at low Q2, 0.02 to 0.24 GeV2 for the neutron (3He)

Covered an unmeasured region of kinematics to test theoretical calculations (Chiral Perturbation theory)

Complements data from experiment E94-010 covered region from 0.1 to 0.9 GeV2

Finalizing systematic uncertainties and first publication

Page 3: E97-110:  Small Angle GDH Experimental Status Report

Neutron Spin Polarizabilities

Page 4: E97-110:  Small Angle GDH Experimental Status Report

E97-110 Spin Polarizabilities

Page 5: E97-110:  Small Angle GDH Experimental Status Report

Experiment E97-110 Inclusive experiment:

◦ Scattering angles of 6◦ and 9◦ ◦ Polarized electron beam:

Avg. Pbeam = 75%◦ Pol. 3He target (para & perp):

Avg. Ptarg = 40%

Measured polarized cross-section differences

Xee )',(He3

M. Amarian et al., PRL 89, 242301 (2002)

Page 6: E97-110:  Small Angle GDH Experimental Status Report

Current WorkWaiting on final target polarization (J. Singh)Elastic 3He analysis (V. Laine)

◦2.1 GeV asymmetry and cross section completed◦Now working on 2.8 GeV data set

Finalize acceptance (V. Sulkosky)Radiative Corrections

◦Preliminary done by J. Singh; code now available◦Tim Holmstrom working on it

Estimation of QE contribution to neutron results (V. Sulkosky)

Page 7: E97-110:  Small Angle GDH Experimental Status Report

9o Acceptance

Septum Mistuned15% uncertainty

Difficulty:◦ Saturation effect is present◦ A few settings were

mistuned with the septum magnet

◦ tg-acceptance appears squeezed at the highest field settings

◦ Varying acceptance cuts does not help

Page 8: E97-110:  Small Angle GDH Experimental Status Report

Interpolation

• The interpolation method works, but there is a concern about the adjacent momentum settings.• Carbon cross section analysis to verify the absolute normalization of the data.

• || 3.6%• Removed edge bins with a secondary process• Corrected remaining edge imperfections with a secondary acceptance correction

Page 9: E97-110:  Small Angle GDH Experimental Status Report

Tools for Carbon Cross Sections

Single carbon foil data were taken for each of the momentum settings for E = 3.775 GeV

Single Arm Monte-Carlo (SAMC) from A. Deur◦ Uses John LeRose transport functions at 9º and apertures ◦ Program complied with QFS subroutines to perform

radiative corrections: internal and external◦ Program utilizes the parameterized cross section for A> 2

from P. Bosted: https://userweb.jlab.org/~bosted/F1F209.f◦ Elastic radiative tail was removed using Rosetail averaged

over the solid angle acceptance of E97-110

Page 10: E97-110:  Small Angle GDH Experimental Status Report

Septum Entrance Apertures

• Shift large angle side by 7mm• Shift small angle side by 5 mm

Page 11: E97-110:  Small Angle GDH Experimental Status Report

Carbon Cross Section 2.007 GeV/c

Page 12: E97-110:  Small Angle GDH Experimental Status Report

Carbon inelastic cross sections

Page 13: E97-110:  Small Angle GDH Experimental Status Report

SummaryWork is progressingAcceptance analysis to be completed

soonMore work needs to go into radiative

corrections:1. Smoothing of the data completed (T.

Holmstrom)2. Finite acceptance for elastic tail subtraction3. Model for the two lowest energies

Draft of first paper completed and internally circulated

Page 14: E97-110:  Small Angle GDH Experimental Status Report

Radiative Tail & Finite Acceptance

Page 15: E97-110:  Small Angle GDH Experimental Status Report

Axial Anomaly and the LT Puzzle

N. Kochelev and Y. Oh; arXiv:1103.4891v1

Page 16: E97-110:  Small Angle GDH Experimental Status Report

Systematic Uncertainties

Page 17: E97-110:  Small Angle GDH Experimental Status Report

Analysis StatusPreliminary results for the moments have been

extracted at constant Q2.Collimator background is mostly from polarized 3He

◦ Need to estimate size of leakage into physics asymmetryIssues and analysis still in progress:

◦ Almost final target polarizations (J. Singh)Waiting to receive final numbers very soon.

◦ Elastic analysis as a cross check of systematics (V. Laine) 2.1 GeV completed; working on other energies now

◦ Acceptance: very messy but making steady progress◦ Finalize radiative corrections (J. Singh, T. Holmstrom & V.

S.)

Page 18: E97-110:  Small Angle GDH Experimental Status Report

Updated SAMC CodeWork done by V. Laine`SAMC rewritten in C++ from FortranImproved implementation of target

collimator cutsRaster correction by calculating electron’s

travel length through the cellRadiative corrections made for each material

separately (previously done all at once)Default units now in meter, gram, GeV and

radian instead of cm and mrad

Page 19: E97-110:  Small Angle GDH Experimental Status Report

Cross Section Smoothing3.319 GeV, 9o

4.404 GeV, 9o

Work by T. Holmstrom

Page 20: E97-110:  Small Angle GDH Experimental Status Report

Delta Acceptance

E94-010

E97-110

• Flat region of -acceptance is much smaller with Septum• Simulation is not perfect on the falling edges

Page 21: E97-110:  Small Angle GDH Experimental Status Report

6o Acceptance Solutions

• || 3.6%• Removed edge bins with a secondary process• Corrected remaining edge imperfections with a secondary acceptance correction

Page 22: E97-110:  Small Angle GDH Experimental Status Report

9-Degree AcceptanceMore painful:

◦Saturation effect is present

◦A few settings were mistuned with the septum magnet

◦tg-acceptance appears squeezed at the highest field settings

Page 23: E97-110:  Small Angle GDH Experimental Status Report

Variation of Acceptance Cuts

Varying acceptance cuts does not help

Page 24: E97-110:  Small Angle GDH Experimental Status Report

Elastic Asymmetry Analysis

Work by V. Laine`

Page 25: E97-110:  Small Angle GDH Experimental Status Report

3He Elastic AcceptanceDelta

ytg W-M

tg tg

Page 26: E97-110:  Small Angle GDH Experimental Status Report

Elastic Cross Section Analysis

Work by V. Laine`

10 A; VDC 19% multi-tracks

Average

Page 27: E97-110:  Small Angle GDH Experimental Status Report

Kinematic Coverage