WELGER RP 435 MASTER E-LINK 3
E-Link for RP 435 MASTER 1 INTRODUCTION.............................................................................................................................5
2 REQUIREMENTS ON THE MACHINE...........................................................................................5
3 SAFETY INSTRUCTIONS ..............................................................................................................6 3.1 WARNING SYMBOLS....................................................................................................................6 3.2 GENERAL INFORMATION..............................................................................................................7 3.3 INSTRUCTIONS FOR FIRE PROTECTION .........................................................................................7 3.4 PROTECTION OF THE ELECTRONIC CONTROL SYSTEM ...................................................................8 3.5 ELECTROMAGNETIC COMPATIBILITY (EMC)..................................................................................8
4 THE MENUS ...................................................................................................................................9 4.1 OVERVIEW .................................................................................................................................9 4.2 SELECT A MENU..........................................................................................................................9
5 "MONITOR" MENU ......................................................................................................................10 5.1 THE DISPLAY ............................................................................................................................11 5.2 TYING MODES...........................................................................................................................12 5.3 HYDRAULIC VALVE BLOCK .........................................................................................................13 5.4 OPERATING PARAMETERS.........................................................................................................16 5.5 MACHINE STATUS: BALING ........................................................................................................20 5.6 MACHINE STATUS: TYING..........................................................................................................20 5.7 MACHINE STATUS: OPEN TAIL GATE...........................................................................................20 5.8 MACHINE STATUS: TAIL GATE OPENED.......................................................................................21 5.9 MACHINE STATUS: CLOSE TAIL GATE .........................................................................................21 5.10 OVERVIEW OF THE KEY FUNCTIONS IN THE "MONITOR" MENU“.....................................................22
6 "SETUP" MENU ...........................................................................................................................23 6.1 OVERVIEW OF THE KEY FUNCTIONS IN THE "SETUP" MENU: .........................................................25
7 "SYSTEMINFO" MENU................................................................................................................26 7.1 OVERVIEW OF THE KEY FUNCTIONS IN THE "SYSTEMINFO" MENU: ................................................27
8 "DIAGNOSIS" MENU ...................................................................................................................28 8.1 STANDARD DIAGNOSIS ..............................................................................................................29 8.2 EXTENDED DIAGNOSIS ..............................................................................................................35 8.3 OVERVIEW OF THE KEY FUNCTIONS IN THE "DIAGNOSIS" MENU:...................................................37
9 "STATISTICS" MENU ..................................................................................................................38 9.1 OVERVIEW OF THE KEY FUNCTIONS IN THE "STATISTICS" MENU: ..................................................39
4 WELGER RP 435 MASTER E-LINK
10 ERROR MESSAGES ................................................................................................................40 10.1 SYSTEM ERROR MESSAGES.......................................................................................................41 10.2 SYSTEM ERROR: "SHORT CIRCUIT IN SUPPLY OF SENSORS" ........................................................41 10.3 SYSTEM ERROR: "BATTERY VOLTAGE TOO HIGH"........................................................................41 10.4 STANDARD ERROR MESSAGES...................................................................................................43 10.5 ERROR MESSAGE: "OVERLOAD" ................................................................................................43 10.6 ERROR MESSAGE: "WIRE BROKEN" ...........................................................................................43 10.7 ERROR MESSAGE: "SET NET KNIFE !" .........................................................................................44 10.8 ERROR MESSAGE: "NET KNIFE SET ?"........................................................................................44 10.9 ERROR MESSAGE: "1 TAILGATE HOOK OPEN" .............................................................................44 10.10 ERROR MESSAGE: "NO PRESSURE INCREASE !"..........................................................................45 10.11 ERROR MESSAGE: "HYD DEN EXEEDED !" ...................................................................................45
11 "SYSTEM SERVICE" MENU ....................................................................................................46 11.1 CALL-UP „SYSTEM SERVICE“ MENU ...........................................................................................46 11.2 "MONITOR" SUBMENU ...............................................................................................................47 11.3 "SYSTEM SETUP" SUBMENU ......................................................................................................47 11.4 "EEPROM CONTENTS" SUBMENU ............................................................................................48 11.5 "SELF TEST" SUBMENU.............................................................................................................48 11.6 OVERVIEW OF THE BUTTON FUNCTIONS IN THE "SYSTEM SERVICE" MENU:...................................49
12 OSCILLOSCOPE ......................................................................................................................50 12.1 OSCILLOSCOPE FOR DIGITAL SENSORS AND ACTORS ..................................................................51 12.2 OSCILLOSCOPE FOR DISTANCE SENSORS...................................................................................52 12.3 OPERATING THE OSCILLOSCOPE................................................................................................53 12.4 OVERVIEW OF THE BUTTON FUNCTIONS IN THE "OSCILLOSCOPE":................................................56
13 APPENDIX ................................................................................................................................57 13.1 CHRONOLOGICAL TYING PROCESS AT AUTOMATIC TYING .............................................................57
Maschinenfabrik GmbH Gebrüder-Welger-Straße 3 • D-38304 Wolfenbüttel Phone: (+49) 53 31 / 404-142 • Fax: (+49) 53 31 / 404-143 eMail: [email protected]
WELGER RP 435 MASTER E-LINK 5
1 Introduction The control contains (see figures bellow): • the control box E-LINK (hand set) • the control unit Balercontrol III The control box E-LINK serves for operating the machine. The control unit Balercontrol III is directly attached to the machine in a solid housing. The control unit and the control box, as well as the respective software contained therein, are provided with their own serial numbers. Always state the serial numbers for possible requests. Please enter this numbers here immediately after delivery:
Part Serial number How to find the serial number
Control box
SW rev. ...........................
dd ...........................
Keep any key on the control box pressed when connecting the power supply.
Call menu overview.
Select SYSTEMINFO menu.
Control unit
Serial no. ...........................
SW version ...........................
SW date ...........................
Memory ...........................
Acknowledge selection.
2 Requirements on the machine • On-board power supply ....................12 V • Fuse protection, machine:.................20 A Operation with 24 V power supply is not permissible.
6 WELGER RP 435 MASTER E-LINK
3 Safety instructions
3.1 Warning symbols
Attention! This symbol stands next to warnings: danger to life, danger of injury, possible serious material damage.
Caution! This symbol stands next to safety instructions: malfunctions and impairments of correct operation, possible material damage.
Note! This symbol stands next to useful information: special information on how to use the machine most efficiently.
WELGER RP 435 MASTER E-LINK 7
3.2 General Information
Attention! Read and heed the operating instruction and safety instructions prior to commission the machine. In this operating instruction all positions required for safety reasons are marked with a warning sign. Instruct all other operators in safety instructions! The warning- and information signs located at the machine give information for safe operation. Watch them for safety reasons!
• It is not permissible to enter the working range of the machine or to approach the working range of the machine as long as the electronics are supplied with power.
• Prior to any kind of assembly, adjustment and maintenance work, the control must be disconnected from power supply: interrupt electrical connection between tractor and machine. Moreover : Switch off power take-off shaft. Switch off tractor engine and remove ignition key. Uncouple power take-off shaft of the machine from the drive shaft of the tractor.
• Check correct setting of all sensors regularly and check that all sensors (proximity switches) and actors (plugs on hydraulic system, plugs on net tying unit or plugs on twine tying unit) are tightened properly.
• Power supply of the electronics must only be switched on when the machine is to be operated. After the end of work, the control system must immediately be disconnected from power supply: interrupt electrical connection between tractor and machine.
• The housing of the control box is moisture-repellent. Nevertheless: in order to avoid malfunctions, the control box must not be exposed to excessive moisture (e.g. heavy rain, splashing, steam-jet- or high-pressure cleaning machine).
• Software- or hardware malfunction can never be totally excluded. Therefore the machine has always to be handled so that no personal or material damages occur.
• Read the pertinent documentation before commissioning the machine. In case of difficulties in understanding please contact the customer service department.
3.3 Instructions for fire protection
• In certain conditions the harvested crop is easily inflammable.
• Keep baler always free from crop remains or oil pollution. This note counts especially after finishing baling.
• The present wiring of the control and of the corresponding machine must not be used for electrical consumers other than mounted or proofed by the manufacturer. Overloading the electrical lines leads to excessive heating.
• Always keep a working fire extinguisher within reach.
8 WELGER RP 435 MASTER E-LINK
3.4 Protection of the electronic control system
• All assembly work (connection and disconnection of sensors, valves, control box etc., replacement of fuses) must be carried out with the power supply switched off.
• The control is designed for 12 Volt operation. Operation with other on-board power supplies is not permissible!
• The correct polarity of the power supply of the tractor must not be changed, otherwise the electronic control could be damaged.
• In case of welding work on the baler: - Do not permit welding current to flow through the control unit; - Interrupt power supply between tractor and baler; - Take heat generation at the welding points into account; if necessary remove sensitive parts (cables, sensors or the like) prior to welding.
3.5 Electromagnetic compatibility (EMC) The machine is equipped with electronic components and modules; the function of these electronic components and modules can be influenced by electromagnetic emissions of other equipment. Such influences can cause risks to persons, if the following safety instructions are not observed: In case of subsequent installation of electrical and electronic equipment and/or components into the machine, with connection to the central mains, it is the user's responsibility to check whether the installation impairs the vehicle electronics or any other components. Ensure above all that the electrical and electronic components subsequently installed are in conformity with the EMC directive 89/336/EEC as amended, and that they are provided with the CE.
WELGER RP 435 MASTER E-LINK 9
4 The menus
4.1 Overview
Menu Task see chapter
MONITOR Display and operation in daily machine operation "Monitor" menu page 10
SETUP Setting of machine parameters "Setup" menu page 23
SYSTEMINFO Information about selected system data "Systeminfo" menu page 26
DIAGNOSIS Diagnostic functions for checking the machine "Diagnosis" menu page 28
STATISTICS Machine running time, cumulative counter and daily counter
"Statistics" menu page 38
4.2 Select a menu
Open menu overview : press key .
Select menu: keys or
Confirm selection with key . If no menu is to be selected: if no key is pressed for 5 seconds, automatic return to the MONITOR menu is effected.
10 WELGER RP 435 MASTER E-LINK
5 "Monitor" menu The MONITOR menu is the standard menu. This menu is used for daily machine operation. The MONITOR menu appears automatically as soon as the control is supplied with power.
Open menu overview: press key
Select MONITOR menu: keys or
Confirm selection with key
The following information are displayed in the menu MONITOR:
Central main field • Machine status (baling, tying, ...) • Bar graph for present and preselected bale diameter • Soft-center mode • Knife in cutting position
Beside the main field • Day counter • Machine working time • Battery voltage • PTO speed
Below the main field • Tying mode • Hydraulic valve block (Cutting device, Bottom door, Pick-Up) • Operating parameter (Bale diameter, Net layers)
WELGER RP 435 MASTER E-LINK 11
5.1 The display
Tying mode
(see page 12) Hydraulic switch
(see page 13) Operating parameter
(see page 16)
manual twine tying
moving the pick-up
bale diameter
automatic twine tying
moving the bottom door
density (pressure)
manual net tying moving the cutting device
(here: 12 knives selected) net layers (here: set value 1.5)
automatic net tying
12 WELGER RP 435 MASTER E-LINK
5.2 Tying modes The machine can be equipped with: • Net tying • Twine tying The tying modes shown in the following table result from the setup setting (see chapter 6 "Setup" menu): Tying mode Machine with
twine tying Machine with
net tying
manual twine tying •
automatic twine tying •
manual net tying •
automatic net tying •
The tying modes can be selected with the left key.
Start tying: Press key <START/STOP> .
WELGER RP 435 MASTER E-LINK 13
5.3 Hydraulic valve block The unit* that is to be moved hydraulically can be selected with the hydraulic switch. * The machine can – according to the type of the machine – be equipped with the following units: • Pick-up (see chapter 5.3.1 Hydraulic switch: Pick-Up) • Bottom door (see chapter 5.3.2 Hydraulic switch: bottom door) • Cutting device (see chapter 5.3.3 Hydraulic switch: Cutting device)
The units are selected with the centre key. The selected unit is displayed directly above the centre key:
Unit Symbol
Pick-Up
bottom door
Cutting device
The selected unit is moved by means of the
tractor's distribution valve.
14 WELGER RP 435 MASTER E-LINK
5.3.1 Hydraulic switch: Pick-Up
Press centre key to select the pick-up The Pick-Up is displayed directly above the centre key: Move Pick-Up with the tractor's distribution valve.
Note!
The valves of the hydraulic switch are not actuated in Pick-Up position This setting has to be preferred to minimise the power consumption.
5.3.2 Hydraulic switch: bottom door
Press centre key to select the bottom door The bottom door is displayed directly above the centre key: Move bottom door with the tractor's distribution valve.
When the bottom door is opened because of a material jam this condition is displayed in a window (symbol "Bottom door"; with flashing exclamation mark).
WELGER RP 435 MASTER E-LINK 15
5.3.3 Hydraulic switch: Cutting device
Press centre key to select the cutting device The cutting device is displayed directly above the centre key: Move cutting device with the tractor's distribution valve.
The machine can be equipped with a group cutting device of 17 knives or of 25 knives. The setting is made in Setup (see chapter 6 "Setup" menu / see separate users manual "RP 405 / RP 435"). • The 17-knife cutting device is divided into 2 groups:
A 8-knife group and a 9-knife group. • The 25-knife cutting device is divided into 2 groups:
A 12-knife group and a 13-knife group. It can be operated with one knife group or both knife groups at the same time. The knife group being in cutting position is displayed (here: 12-knife group).
Caution! Before a knife group can be moved into operating position all knives that are possibly already in operating position, must be moved out of the operating position. If it must be operated with an other knife group, first the knife group being in operating position must be moved into home position before the new knife group can be moved from its home position into operating position.
Only those knife groups are displayed that can be moved in or out for the current moment, e.g. (here: 12-knife group).
16 WELGER RP 435 MASTER E-LINK
5.4 Operating parameters The operating parameters are selected with the right key. The operating parameter selected is displayed directly above the key.
5.4.1 Operating parameters: Set / read bale diameter Set bale diameter: after selection of the operating parameter "Bale diameter" the value can be set
in 1-digit increments using the keys / .
The following overview shows the possible numerical values for the bale diameter display:
Minimum bale diameter
Maximumbale diameter
*90 *91 *92 ... *98 *99 00 01 02 ... 58 59 60
Read bale diameter: the bale diameter currently reached can be read on the indicating instrument
on the machine (see left figure) or on the display of the control box (see right figure).
WELGER RP 435 MASTER E-LINK 17
5.4.2 Operating parameters: Set / read baling density Set baling density (= bale density, = pressure): after selection of the operating parameter "Baling
density" the value can be set in 1-digit increments using the keys / . The following overview shows the possible numerical values for the baling density:
Minimum baling density
Maximumbaling density
0 1 2 3 4 5 6 7 8 9 10
When the baling density reaches stage 10 in a manual tying mode, the message "Stop: Max. baling density reached" is output (see chapter 10 Error messages). Read baling density (pressure): the baling density currently reached can be read on the pressure
gauge on the machine (see figure).
18 WELGER RP 435 MASTER E-LINK
Emergency operation: Set baling density If one of the following error messages appears
ERROR! PRESSURE SENSOR WIRE BROKEN
or ERROR! NO PRESSURE INCREASE
but the pressure gauge on the machine still indicates a pressure (baling density), a defective pressure sensor may be the cause of the fault. Nevertheless the baling density can be set in the mergency operating mode described below:
Set baling density to "0" : press key .
Press key and key simultaneously. Now an "X" appears in the display (in the place where usually the baling density is displayed), see figure.
To set the baling density: (Valve on machine tail) Turn the handwheel
attached laterally to the machine clockwise up to the stop. In this position the maximum pressure (maximum baling density) is set.
If a lower baling density is desired you can turn the handwheel back in counterclockwise direction.
WELGER RP 435 MASTER E-LINK 19
5.4.3 Operating parameters: Set net layers Net layers can only be set on the control box, when electronic net control has been selected in the
"Setup" menu (see chapter 6 "Setup" menu, page 23): EL.NET-CTRL. = YES Set net layers: After selection of the operating parameter "Net layers" the value can be set in
increments of 0.5 using the keys / . The following overview shows the possible numerical values for the net layers:
Few net layers
Manynet layers
0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
After the net length (required for the set number of net layers) has passed the machine, the net knife is automatically activated and tying is finished.
20 WELGER RP 435 MASTER E-LINK
5.5 Machine status: Baling The machine status baling is displayed by an animated material flow into the baler, when the PTO speed is larger than 100 rpm (revolutions per minute).
5.6 Machine status: Tying Two rotating arrows indicate that tying is being carried out.
5.7 Machine status: Open tail gate After tying has been finished, the electronics indicate with a flashing arrow and a beep to open the tail gate. No material flows any more into baler.
WELGER RP 435 MASTER E-LINK 21
5.8 Machine status: Tail gate opened The open tail gate is displayed in the main window. There is no material flow.
5.9 Machine status: Close tail gate After the bale has left the baler, the electronics indicate with a flashing arrow to close the tail gate. No material flows into baler.
22 WELGER RP 435 MASTER E-LINK
5.10 Overview of the key functions in the "Monitor" menu“
Key Operation
left key
Select tying mode (see chapter 5.2 Tying modes): • manual twine tying • automatic twine tying • manual net tying • automatic net tying
centre key
Select hydraulic switch (see chapter 5.3 Hydraulic valve block): • Pick-Up • bottom door • cutting device 8 knives (optional: 12 knives) • cutting device 9 knives (optional: 13 knives) • cutting device 17 knives (optional: 25 knives)
right key
Select operating parameter (see chapter 5.4 Operating parameters): • Bale density • Baling density (pressure) • Net layers
Start selected tying mode manually
Increase set value for selected operating parameters • Bale density • Baling density (pressure) • Net layers
Decrease set value for selected operating parameters • Bale density • Baling density (pressure) • Net layers
– no function –
Acknowledge fault message (delete) (see chapter 10 Error messages)
Call up menu
WELGER RP 435 MASTER E-LINK 23
6 "Setup" menu The SETUP menu serves for setting various machine parameters (Language, Machine type, Beep ...).
Open menu overview: press key
Select Setup menu: keys or
Confirm selection with key
Select parameter: keys and
Change parameter: keys and
Either return to menu overview: press key
Or return to MONITOR menu: press key for 3 sec.
Scroll the display pages forward and backward:
left and right key.
24 WELGER RP 435 MASTER E-LINK
The following machine parameters can be set:
Machine parameter Setting range
Language English– German – French – Swedish – Norwegian – Finnish – Spanish – Italian – Danish – Dutch
Machine type RP435
RP435S (with cutting device)
Delay
(Delay of the buzzer while twine tying or net insertion while net tying during the tying process, see chapter 13 Appendix)
0 sec. / 2,5 sec. / 5,0 sec.
Soft center
yes / no „yes“ means: The bale is to be produced with a softer center. Therefore the preset pressure in the baling chamber does not build up completely (up to the user entered value) before the bale diameter has reached 75 % of the preset value.
Net tying
(setting according to machine's equipment)
yes / no
Twine tying
(setting according to machine's equipment)
yes / no
Electronic net control
(= electronic monitoring of the set number of net layers)
yes / no "yes" means: • input of the desired number of net layers via E-
LINK control box (see chapter "5.4.3 Operating parameters: “Set net layers", page 19).
• electronic control / monitoring of the set number of net layers by the control system.
"no" means: • emergency function only! Input of the desired
number of net layers by means of the wing nut in the slotted hole of the net tying unit (see chapter "Emergency operation: Net tying" in the separate manual "RP 405/435").
Knives
(only for machine type RP435S)
13, 17 or 25
Beep
0 ... 50
WELGER RP 435 MASTER E-LINK 25
6.1 Overview of the key functions in the "Setup" menu:
Key Operation
left key
Scroll display pages backwards
centre key
– no function –
right key
Scroll display pages forward
– no function –
Change parameter
Change parameter
Select parameter
Select parameter
Open menu overview: short key stroke
Return to MONITOR menu: 3 sec. key stroke
26 WELGER RP 435 MASTER E-LINK
7 "Systeminfo" menu
Open menu overview: press key .
Select SYSTEMINFO menu: key or
Confirm selection with key . SYSTEMINFO menu provides information about important system data: Serial number Software version Software date Memory
The menu SYSTEMINFO is exclusively for information. Data can neither be entered nor selected in the menu SYSTEMINFO.
Either return to menu overview: press key
Or return to MONITOR menu: press key for 3 sec.
WELGER RP 435 MASTER E-LINK 27
7.1 Overview of the key functions in the "Systeminfo" menu:
Key Operation
left key
– no function –
centre key
– no function –
right key
– no function –
– no function –
– no function –
– no function –
– no function –
– no function –
Open menu overview: short key stroke
Return to MONITOR menu: 3 sec. key stroke
28 WELGER RP 435 MASTER E-LINK
8 "Diagnosis" menu The control contains extensive diagnostic routines for checking the function the electric equipment. There are two diagnostic routines:
Standard diagnosis (see chapter 8.1 Standard diagnosis) Standard diagnosis may only be performed after the machine has been stopped. In addition, a fully automatic actor test is possible.
Extended diagnosis (see chapter 8.2 Extended diagnosis) Diagnostic functions while machine is in operation. Observation of all sensor channels and actor channels possible. Selection via special key combination.
Attention, danger of injury! Extended diagnosis is executed while the machine is running. For trained and instructed service personnel only!
WELGER RP 435 MASTER E-LINK 29
8.1 Standard diagnosis
Attention, danger of injury! Standard diagnosis may only be performed after the machine has been stopped: Switch off tractor engine, wait until machine has stopped, disconnect hydraulic supply to the machine.
Open menu overview : press key
Select DIAGNOSIS menu: keys or
Confirm selection with key
To previous display page: left key
To next display page: right key
Either return to menu overview: press key
Or return to MONITOR menu: press key for 3 sec.
8.1.1 Standard diagnosis – Digital sensors
Digital sensors are e.g. proximity sensors and switches. In the DIGITAL SENSORS DIAGNOSIS, the status of proximity sensors and switches is displayed.
Note! The number of the sensors shown or of the display pages depends on the settings in the "Setup" menu (see chapter 6 "Setup" menu).
The following symbols are used for the sensor status: Sensor type Symbol Status Proximity sensors
covered („sees“ metal)
uncovered („sees no metal“)
Switch
opened
closed
30 WELGER RP 435 MASTER E-LINK
On the page DIAGNOSIS DIGITAL SENSORS 1/2 the following sensors are displayed:
Diagnosis Digital Sensors 1/2 Abbreviation Name Sensor checks
RPM revolutions per minute revolutions of p.t.o
DIAMETER max. bale diameter position of the tailgate wing
PRESS.SW locking of the cutting device
pressure in the cutting device hydraulics
CUTT.DEV.1 knife group 1 (smaller group)
knives in cutting position?
BOTTOM bottom (bottom door) open / closed?
NETKNIFE net knife (only for net tying)
home position / cutting position?
NET RUN net run (only for net tying)
revolutions of the net infeed roll (determination of the net length)
CUTT.DEV.1 knife group 1 (smaller group)
knives in cutting position?
On the page DIAGNOSIS DIGITAL SENSORS 2/2 the following sensors are displayed:
Diagnosis Digital Sensors 2/2 Abbreviation Name Sensor checks
HOOK L. Locking device, left open / closed?
HOOK R. Locking device, right open / closed?
EJECTOR Bale kicker up / down
TWINE L. Left twine Twine run left (only twine tying)
TWINE R. Right twine Twine run right (only twine tying)
In the E-LINK system, an oscilloscope is available in addition to the various diagnostic functions (see chapter 12 Oscilloscope). The oscilloscope can be used to view and analyse the status of all digital sensors and actors during the last 500 seconds. Viewing of all signals in real time is also possible:
To the oscilloscope: press centre key
Net tying
Twine tying
Net tying
Twine tying
WELGER RP 435 MASTER E-LINK 31
8.1.2 Standard diagnosis – Analog sensors In DIAGNOSIS ANALOG SENSORS the state of the analog sensors is displayed. On the page DIAGNOSIS ANALOG SENSORS 1/2 the following sensors are displayed:
Diagnosis Analog Sensors ½ Abbreviation Meaning
DIAMETER Voltage value [Volt] shows the position of the tailgate wing (corresponds to the present bale diameter).
RP 435: 0,5 Volt (with empty bale chamber) RP 535: 0,45 Volt (with empty bale chamber) On the page DIAGNOSIS ANALOG SENSORS 2/2 the following sensors are displayed:
Diagnosis Analog Sensors 2/2 Abbreviation Meaning
PRESSURE Measured value [per cent] indicates the pressure in the hydraulic bale density control system (corresponds to the current bale density).
CALIBRATING Measured value [per cent] indicates the hydraulic zero point of the pressure sensor.
PRESSURE SENSOR TYPE
Indicates the recognised pressure sensor type: Type 1 / Type 2
32 WELGER RP 435 MASTER E-LINK
8.1.3 Standard diagnosis – Actors
Actors are e.g. electro-valves of the hydraulic system. In the ACTOR DIAGNOSIS, the status of the actor channels is displayed. The functions can be tested manually (Diagnosis Manual) or automatically (Diagnosis Automatic).
Attention, danger of injury! Standard diagnosis may only be performed after the machine has been stopped: Switch off tractor engine, wait until machine has stopped, disconnect hydraulic supply to the machine.
Note! The number of the actors shown or of the display pages depends on the settings in the "Setup" menu (see chapter 6 "Setup" menu). See following chapters: "Standard diagnosis – Actors – Manual" page 33" "Standard diagnosis – Actors – Automatic" page 34
WELGER RP 435 MASTER E-LINK 33
Standard diagnosis – Actors – Manual To toggle between DIAGNOSIS ACTORS MANUAL and DIAGNOSIS ACTORS AUTOMATIC:
Press key <START/STOP>.
Select actor channel: keys and
Switch actor on: key
Switch actor off: key The following symbols are used for the actor status: Symbol Actor status
Actor has been triggered (+) and has switched (+).
Actor should be triggered (+), but has not switched (–). Attention, fault! e. g. actor channel in control unit defective.
Actor not triggered (–), but has switched (+). Attention, fault! e. g. short circuit or broken wire.
Actor has not been triggered (–) and has not switched (–).
On the page DIAGNOSIS ACTORS MANUAL 1/1 the following actors are displayed:
Diagnosis Actors Manual 1/1 Abbreviation Channel designation
VAL.B1 Valve B1*
VAL.B2 Valve B2*
VAL.B3 Valve B3*
VALB45 Valve B45*
PVALVE Control valve of hydraulic bale density control system
NET CLUT Magnetic clutch of the net tying unit
NET KNIFE net knife tripping device
TWI MOT Motor twine insertion
* these names are on the plugs or on the hydraulic block (according to the version of the machine)
Or return to MONITOR menu: press key for 3 sec.
Net tying
Twine tying
34 WELGER RP 435 MASTER E-LINK
Standard diagnosis – Actors – Automatic To toggle between DIAGNOSIS ACTORS MANUAL and DIAGNOSIS ACTORS AUTOMATIC:
Press key <START/STOP>. In the DIAGNOSIS ACTORS AUTOMATIC, all actors are automatically triggered and tested in succession. The following symbols are used for the actor status: Symbol Actor status
Actor channel is OK.
Actor channel is faulty.
On the page DIAGNOSIS ACTORS AUTOMATIC 1/1 the following actors are displayed:
Diagnosis Actors Automatic 1/1 Abbreviation Channel designation
VAL.B1 Valve B1*
VAL.B2 Valve B2*
VAL.B3 Valve B3*
VALB45 Valve B45*
PVALVE Control valve of hydraulic bale density control system
NET CLUT Magnetic clutch of the net tying unit
NET KNIFE net knife tripping device
TWI MOT Motor twine insertion
* these names are on the plugs or on the hydraulic block (according to the version of the machine) In the E-LINK system, an oscilloscope is available in addition to the various diagnostic functions (see chapter 12 Oscilloscope). The oscilloscope mode can be used to view and analyse the status of all digital sensors and actors during the last 500 seconds. Viewing of all signals in real time is also possible:
To the oscilloscope: press centre key .
Or return to MONITOR menu: press key for 3 sec.
Net tying
Twine tying
WELGER RP 435 MASTER E-LINK 35
8.2 Extended diagnosis
Attention, danger of injury! Extended diagnosis is executed while the machine is running. For trained and instructed service personnel only!
The extended diagnosis offers a possibility of viewing the state of sensor and actors during machine operation. Operation of the extended diagnosis is identical to that of the standard diagnosis (see chapter „8.1 Standard diagnosis). In case of extended diagnosis, however, the service personnel has exclusively the function of an observer. Any interference in the sequence of machine operations (e.g. starting of the automatic actor diagnosis or switching of a selected actor channel) will immediately stop machine operation and thus the extended diagnosis.
Indication for extended diagnosis: the symbol (AUTOMATIC) flashes.
Net tying
Twine tying
Net tying
Twine tying
36 WELGER RP 435 MASTER E-LINK
Attention, danger of injury! While the machine is in operation: Never climb the machine. Keep sufficient distance to the range of action of the machine: Pick-up, tail gate. Never stay or work below the machine. Never carry out any adjustment and maintenance work on the machine while the drive is running. Before opening the protections: Switch-off tractor's engine, wait for stand still of the machine, take-out ignition key of the tractor, interrupt hydraulic supply to the machine.
Open menu overview: press key
Call extended diagnosis: Press centre key
and key simultaneously.
Either return to menu selection: press key
Or return to MONITOR menu: press key for 3 sec.
WELGER RP 435 MASTER E-LINK 37
8.3 Overview of the key functions in the "Diagnosis" menu:
Key Operation
left key
Page backwards
centre key
Call up oscilloscope
right key
Page forwards
Toggling between automatic and manual actor diagnosis:
Actor channel On
Actor channel Off
Select actor
Select actor
Open menu overview: short key stroke
Return to MONITOR menu: 3 sec. key stroke
38 WELGER RP 435 MASTER E-LINK
9 "Statistics" menu
Open menu overview : press key
Select STATISTICS menu: keys or
Confirm selection with key The STATISTICS menu provides an overview of Bale number (daily counter) Bale number (total) Machine running time (daily counter) Machine running time (total)
The "total" counters for bale number (example: 42) and machine running time (example: 44.1 h) are cumulative counters and cannot be erased. 20 daily counters are supported (#1, #2, #3 ... #20). The daily counter selected in each case is used for counting. Select daily counter (view and activate):
press key or
Erase selected daily counter: press keys and
simultaneously for 3 seconds. Symbol Meaning
Total Bale number (total)
#3
Bale number (daily counter)
(here e.g. daily counter number 2)
Total Machine running time (total)
#3
Machine running time (daily counter)
(here e.g. daily counter number 2)
Either return to menu selection: press key
Or return to MONITOR menu: press key for 3 sec.
WELGER RP 435 MASTER E-LINK 39
9.1 Overview of the key functions in the "Statistics" menu:
Key Operation
left key
– no function –
centre key
– no function –
right key
– no function –
– no function –
+ Erase selected daily counter: 3 sec. key stroke
Select daily counter (#1, #2, #3, ... #20)
Select daily counter (#1, #2, #3, ... #20)
Open menu overview: short key stroke
Return to MONITOR menu: 3 sec. key stroke
40 WELGER RP 435 MASTER E-LINK
10 Error messages Error messages are displayed in a separate window above the current screen. Error messages consist of: • the word ERROR • the error message (text) • a flashing warning triangle • the number of errors which occurred (below the flashing warning triangle) For example:
If several errors occur at the same time, the error message of the highest priority is displayed first. A distinction is made between: • System error messages (see from chapter 10.1 System error messages) • Standard error messages (see from chapter 10.4 Standard error messages)
Note! If possible errors cannot be removed: Inform the customer service department. Tell the customer service about the displayed error messages. The error messages contain important information about the causes of a possible malfunction to the customer service.
WELGER RP 435 MASTER E-LINK 41
10.1 System error messages System error messages appear in all menus. Exception: standard diagnosis (where no machine functions are in operation). System error messages cannot be acknowledged by pressing a key. They disappear when the cause of the error has been eliminated.
10.2 System error: "Short circuit in supply of sensors" While problems during the sensor's power supply (e.g. during a short circuit in the sensor's power supply or during bad main power supply) the sensor and actor supply of the control unit is switched of automatically, an error window is displayed and an alarm tone sound from the control box. This error cannot be acknowledged. It disappears when the error cause (short circuit or bad main power supply) has been removed.
Interrupt power supply immediately: pull plug (DIN 9680B)
If the error occurs again after reconnection of the power supply, baling can be processed with
switched off electronics and by means of emergency tying (see users manual of the machine, chapter "Emergency operation"). Inform customer service!
Use the delivered cable (part no. 0972.20.40.00) to avoid a bad main power supply.
10.3 System error: "Battery voltage too high" In case of excess voltage in the onboard power supply (battery voltage > 17 Volt), the sensor and actor supply of the control unit is switched off, an error window is opened and a permanent warning signal sounds in the control box. This error cannot be acknowledged. The error message disappears when the cause of the error has been eliminated. Inform customer service! Twine tying Interrupt power supply between tractor and
machine immediately: Pull out plug [1]. If the error occurs again after reconnection of the power supply baling can be processed with emergency tying: Disconnect control unit: pull both 35-pin plugs [3]. Disconnect control box: pull 7-pin plug [2]. Connect power supply: Insert plug [1] into the
socket at the tractor. See users manual of the machine, chapter
"Emergency operation of the tying": The red attachment plug for the twine tying is simply plugged into the empty white socket.
To trigger the twine tying switch on the parking light (or the low beam or the high beam) for a short time until the twine is grasped by the bale.
42 WELGER RP 435 MASTER E-LINK
Net tying Interrupt power supply between tractor and
machine immediately: Pull out plug [1]. If the error occurs again after reconnection of the power supply baling can be processed with emergency tying: Interrupt power supply: Pull plug [1] out of the
socket at the tractor. See operating manual of the machine, chapter
"Emergency operation": The black attachment plug of the electric net coupling is simply plugged into the empty white socket.
See operating manual manual of the machine, chapter "Emergency operation": Make additional mechanical adjustments.
To trigger the net tying switch on the parking light (or the low beam or the high beam) for a short time until the net is grasped by the bale (recognisable from the fast rotation of the net roll).
WELGER RP 435 MASTER E-LINK 43
10.4 Standard error messages Standard error messages can appear in all menus. Exception: DIAGNOSIS menu. The standard error messages OVERLOAD and WIRE BROKEN are not displayed there. Reaction to standard error messages:
Option 1: press key to acknowledge the standard error message. Subsequently, the cause of the fault must be eliminated.
Option 2: The standard error message disappears automatically when the cause of the error has been eliminated.
10.5 Error message: "Overload" An error has occurred which has caused overload of an output channel. The output has been switched off. The error message can be acknowledged, the output remains, however, blocked until restart of the system (pull the power supply plug).
Acknowledge fault messages: press key
10.6 Error message: "Wire broken" A broken wire or a non-connected load has been recognized. The error message can be acknowledged or disappears automatically when the load is connected again.
Acknowledge fault messages: press key
44 WELGER RP 435 MASTER E-LINK
10.7 Error message: "Set net knife !" Automatic net wrapping should have been started, but the net knife sensor is not damped. After removal of the error message, net wrapping can be started manually (net knife sensor is ignored).
Acknowledge fault messages: press key Start manual net tying (see operating manual of
the machine, chapter "Operation / Tying").
10.8 Error message: "Net knife set ?" Manual net wrapping should have been started, but the net knife sensor is not damped. After removal of the error message, net wrapping can be started manually (net knife sensor is ignored).
Acknowledge fault messages: press key
10.9 Error message: "1 tailgate hook open" A locking hook is open. The error message can be acknowledged or disappears automatically when both locking hooks are open or both locking hooks are closed.
Acknowledge fault messages: press key
WELGER RP 435 MASTER E-LINK 45
10.10 Error message: "No pressure increase !" No pressure is built up in the hydraulic tensioning system during baling. The error message can be acknowledged.
Acknowledge fault messages: press key
10.11 Error message: "hyd den exeeded !" After opening of the tail gate, hydraulic pressure is not released. The error message can be acknowledged.
Acknowledge fault messages: press key
46 WELGER RP 435 MASTER E-LINK
11 "System Service" menu
Attention! The following chapter is intended exclusively for trained and instructed service personnel!
The SYSTEM SERVICE menu provides the following submenus for first commissioning and servicing of the machine:
Submenu Task see chapter
MONITOR Terminates SYSTEM SERVICE menu and starts MONITOR menu.
"Monitor" submenu“ page 47
SYSTEM SETUP Machine model toggling, if several user interfaces are available.
"System Setup" submenu" page 47
EEPROM CONTENT
Display of the EEPROM contents. "EEPROM Contents" submenu" page 48
SELF-TEST Self test of the control (in connection with a special testing device).
"Self Test" submenu" page 48
11.1 Call-up „System Service“ menu
Call up SYSTEM SERVICE: hold centre button depressed (for about 10 seconds) when switching on the control voltage.
Select submenu: keys or
Call-up selected submenu: Button
WELGER RP 435 MASTER E-LINK 47
11.2 "Monitor" submenu This menu entry terminates SYSTEM SERVICE and causes return to the Monitor menu, see chapter 5 "Monitor" menu, page 10.
Select MONITOR menu: keys or
Confirm selection with button .
11.3 "System Setup" submenu The control can be used on other prepared machine families.
Select SYSTEM SETUP menu: keys or
Confirm selection with key
Select machine family: keys or
Call up selected machine family: Button Now, the control jumps automatically back to the SETUP menu (see chapter 6 "Setup" menu). To safe the changed setting:
Save selection with button
48 WELGER RP 435 MASTER E-LINK
11.4 "EEPROM Contents" submenu In this submenu the contents of the EEPROM is shown in hexadecimal form (for diagnostic purposes).
Select EEPROM CONTENTS menu: keys or
Confirm selection with key
Line scrolling: keys or
Page scrolling: press key or
Return to SYSTEM SERVICE: button
11.5 "Self Test" submenu A fully automatic self-test can be carried out only in connection with special test equipment designed for this purpose. The self-test cannot be started without this test equipment, and is not described here.
Select SELF-TEST menu: keys or
Confirm selection with button
Return to SYSTEM SERVICE: press key
WELGER RP 435 MASTER E-LINK 49
11.6 Overview of the button functions in the "System Service" menu:
Operation Key
System Service System Setup EEPROM contents Self test
left button
centre button
right button
Select machine family Scroll up by one line
Select machine family Scroll down by one line
Select submenu Scroll down by one page
(8 lines)
Select submenu Scroll up by one page
(8 lines)
Open menu overview
Call-up selected submenu
Call SETUP of the selected machine family
Return to the SYSTEM SERVICE menu
Return to the SYSTEM SERVICE menu
50 WELGER RP 435 MASTER E-LINK
12 Oscilloscope The oscilloscope is used for checking digital sensors, actors, and distance sensors. • see chapter „12.1 Oscilloscope for digital sensors and actors“ • see chapter „12.2 Oscilloscope for distance sensors“ The oscilloscope mode can be used to view and analyse the status of all sensors and actors during the last 500 seconds (about 8 minutes). Viewing of all signals in real time is also possible.
In each diagnostic display (see chapter 8
"Diagnosis" menu) the centre button leads to the corresponding oscilloscope.
WELGER RP 435 MASTER E-LINK 51
12.1 Oscilloscope for digital sensors and actors
Diagnosis page: (here: digital sensors)
Measured data recording: RUN: recording is running
Designation of the sensor/actor channels (see chapter 12.3.7).
Page number
Sensor/actor status High: damped/connected Low: uncovered/disconnected
Time window here: 10 sec. set
Measured data recording: HOLD: recording stopped
Channels not used
Cursor Cursor position here: 495.2 sec.
52 WELGER RP 435 MASTER E-LINK
12.2 Oscilloscope for distance sensors
Actual measurement value(in the RUN-mode, this value is refreshed all the time) (here: 2.30 V)
Zoom factor (here: factor 2.5)
Offset (zero point) (here: 1.0 V)
Cursor Cursor position (here: 490.2 sec.)
Actual measurement value (in the HOLD mode the value is displayed at the cursor position) (here: 2.02 V)
WELGER RP 435 MASTER E-LINK 53
12.3 Operating the oscilloscope
12.3.1 Paging through the oscilloscope screens You can page through the oscilloscope screens:
right button page up.
left button page down.
12.3.2 Start or stop recording (RUN mode / HOLD mode) Recording of the measurement data can be
stopped (HOLD mode) and restarted (RUN mode)
by pressing button <START-STOP>.
12.3.3 „Time window“ function The „Time window“ function serves to set the period of time corresponding to a window size, e.g.: window size T = 10 seconds window size T = 20 seconds window size T = 50 seconds window size T = 100 seconds window size T = 200 seconds window size T = 500 seconds
Position the selection bar (black) on the "Time
Window" function using the buttons and (see dashed circle).
Set the value for the window size by means of the
keys and
12.3.4 „Cursor“ function When recording has been stopped (HOLD), the "Cursor" function can be used to view all times of the course recorded before: Position the selection bar (black) on the "Cursor"
function using the buttons and (see dashed circle).
Move cursor to the desired position: buttons
and
54 WELGER RP 435 MASTER E-LINK
12.3.5 Function "Zoom" (only for the oscilloscope for analog sensors) The „Zoom“ function can be used to enlarge the displayed value range (that means the vertical scale axis). E. g.: „Zoom = 1“ means: the displayed value range
comprises 100 % of the measured values. „Zoom = 2.5“ means: the displayed value range
comprises 40 % of the measured values. „Zoom = 5“ means: the displayed value range
comprises 20 % of the measured values. „Zoom = 10“ means: the displayed value range
comprises 10 % of the measured values. Position the selection bar (black) on the "Zoom"
function using the keys and
Set zoom factor by means of the keys and
12.3.6 Function "Offset" (only for the oscilloscope for analog sensors) The „Offset“ function can be used to shift the origin of the displayed value range (that means the vertical scale axis). This function is used when Zoom is used; that means with a zoom factor larger than 1. Example „Zoom factor = 5“. Only 20 % of all measured values are displayed. Set Offset to 25 %. In this case the measured
values 25 % to 45 % are displayed. Or, set Offset to 50 %. In this case the measured
values 50 % to 70 % are displayed. Or, set Offset to 63 %. In this case the measured
values 63 % to 83 % are displayed.
Position the selection bar (black) on the "Offset"
function using the keys and
Set Offset value by means of the keys and
WELGER RP 435 MASTER E-LINK 55
12.3.7 Designation of the sensor channels and actor channels Net tying
Abbreviation Sensors
Channel designation Sensors
AbbreviationActors
Channel designation Actors
DZ Speed B1 Valve B1 B.D. Max. bale diameter B2 Valve B2 D.S. Pressure switch B3 Valve B3 S.W.1 S.W.2
Cutting device B45 Valve B45
BODN Bottom door NETZ Net coupling N.M. Net knife N.L. Net length V.L. Locking device, left N.M. Net motor V.R. Locking device, right BAW Bale ejector Twine tying
Abbreviation Sensors
Channel designation Sensors
AbbreviationActors
Channel designation Actors
DZ Speed B1 Valve B1 B.D. Max. bale diameter B2 Valve B2 D.S. Pressure switch B3 Valve B3 S.W.1 S.W.2
Cutting device B45 Valve B45
BODN Bottom door GARN Twine motor FA.L. Twine run left FA.R. Twine run right V.L. Locking device, left V.R. Locking device, right BAW Bale ejector
56 WELGER RP 435 MASTER E-LINK
12.4 Overview of the button functions in the "Oscilloscope":
Key Operation
left button
Page forwards
centre button
Call-up/terminate oscilloscope
right button
Page backwards
Switch between RUN mode (recording started) and HOLD mode (recording stopped)
Increase selected oscilloscope parameters
- Page shown
- Time window set (10s - 20s - 50s - 100s - 200s - 500s)
- Cursor position (in HOLD mode only)
- Offset (0..90% measuring range) (only for oscilloscope for distance sensors) - Zoom factor (1x - 2.5x - 5x - 10x) (only for oscilloscope for distance sensors)
Reduce selected oscilloscope parameters
- Page shown
- Time window set (10s - 20s - 50s - 100s - 200s - 500s)
- Cursor position (in HOLD mode only)
- Offset (0..90% measuring range) (only for oscilloscope for distance sensors) - Zoom factor (1x - 2.5x - 5x - 10x) (only for oscilloscope for distance sensors)
Select oscilloscope parameters
- Page shown
- Time window set (10s - 20s - 50s - 100s - 200s - 500s)
- Cursor position (in HOLD mode only)
- Offset (0..90% measuring range) (only for oscilloscope for distance sensors) - Zoom factor (1x - 2.5x - 5x - 10x) (only for oscilloscope for distance sensors)
– no function –
WELGER RP 435 MASTER E-LINK 57
13 Appendix
13.1 Chronological tying process at automatic tying The value "Delay" can be set in menu SETUP (see chapter 6 "Setup" menu).
TWINE TYING
Buzzer
Twine motor
Delay: 0 .. 5.0 sec
8.0 sec
3.0 sec
3.0 sec
Delay: 0 .. 5.0 sec 3.0 sec Net magnet
Buzzer
NET TYING