학술논문 Journal of Biomedical Engineering Research 38: 183-189 (2017) http://dx.doi.org/10.9718/JBER.2017.38.4.183 183 전기 수술기 파워 자동 측정 시스템 개발 김수홍·윤성욱·조명헌·전계록 부산대학교 의공학교실, 양산부산대학교병원 의공실 Development of Automatic Power Measurement System for Electrosurgical Unit SooHong Kim, SungUk Yun, MyoungHun Joh and GyeRok Jeon Department of Biomedical Engineering, School of Medicine, Pusan National University Department of Biomedical Engineering, Pusan National University Yangsan Hospital, Korea (Manuscript received 27 June 2017 ; revised 10 August 2017 ; accepted 24 August 2017) Abstract: Electrosurgical Unit(ESU) is medical equipment that cut or coag tissues using electrical energy. It is used in hospitals’ outpatient clinic room and operating room. Improper use of an ESU may cause fatal injuries to the patient, such as burns. So, before using an ESU, make sure that it is supplying enough energy for cut and coag by measuring the output power and checking the output power cable. In this study, we developed a simple ESU power measurement system PW100 that allows anyone to check the basic output power. And PW100 can check the state of the cable associated with the output power before using ESU. Then, we compared the measured output power of the PW100 with an ESU Analyzer which was commercialized, and compared the performance. In the experiment, the output power measured by the PW100 was lower value than an ESU Analyzer’s that. However, the PW100’s output power measured in the 5% error range and showed stable reproducibility by a low %RSD value. Key words: medical equipment, electrical energy, electrosurgical unit, output power, analyzer I. 서 론 병원에서는 외래의 간단한 시술부터 수술실의 중대한 수 술까지 의료기기를 통한 여러가지 물리적인 에너지를 사용 하고 있다. 의학과 공학의 발달에 따라 빛, 열, 전기 등 새 로운 에너지를 이용한 시술이 증가 하고 있으며 의료기기 또한 발전되고 있다. 이렇게 체외에서 인체에 에너지를 적 용 하는 의료기기는 과도한 사용으로 때로는 인체에 치명적 인 영향을 줄 수 있다. 그래서 의료기기를 사용하기 전에 기 기에서 발생되는 에너지를 측정하고 교정하여 안전하게 사 용하기 위한 성능평가는 반드시 이루어져야 한다[1]. 이는 의료기기의 예방점검을 통해 환자에게 가해질 수 있는 위험 을 최소화하여 환자의 안전을 최대화하기 위함이다. 그래서 의료기기의 출력 에너지를 측정하고 시스템을 평가하기 위 한 의료용 에너지 자동측정 및 성능평가용 계측기기는 의료 의 질 향상과 환자 안전을 위해 반드시 필요하다[2]. 의료용 에너지 중 가장 많이 사용되고 있는 전기에너지를 이용하여 병원의 외래 및 수술실에서 조직을 절개하거나 지 혈을 하는 의료기기로 전기수술기(Electrosurgical Unit, ESU) 가 있다. ESU는 강한 전류에 의해 순간적으로 많은 열이 발생하면 열이 집중된 부위의 조직이 수분과 함께 증 발되어 조직과 조직이 분리되는 절개의 효과를 얻을 수 있 고 설정된 전류를 통해 일정한 열을 발생시켜 조직 내의 수 분을 서서히 증발시킴으로 조직을 굳히는 응고의 효과도 얻 을 수 있다. 이렇게 ESU는 고주파 전류를 사용하여 전력 (watt) 과 파형(pulse) 의 형태로 많을 열을 통해 절개와 응 고 작용을 한다[3]. ESU의 출력은 두 가지 방식이 있는데 고주파 전류의 한 Corresponding Author : GyeRok Jeon Department of Biomedical Engineering, School of Medicine, Pusan National University TEL: +82-55-360-1922 E-mail : [email protected]이 연구는 2016년도 양산부산대학교병원 재원으로 지원을 받아 수 행되어 기초 연구되었음( 양산부산대학교병원 직무연구-5).
7
Embed
전기 수술기 파워 자동 측정 시스템 개발전기 수술기 파워 자동 측정 시스템 개발 - 김수홍·윤성욱·조명헌·전계록 184 쪽 극을 넓은 전극
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
학 술 논 문
Journal of Biomedical Engineering Research 38: 183-189 (2017)
http://dx.doi.org/10.9718/JBER.2017.38.4.183
183
전기 수술기 파워 자동 측정 시스템 개발
김수홍·윤성욱·조명헌·전계록
부산대학교 의공학교실, 양산부산대학교병원 의공실
Development of Automatic Power Measurement System for
Electrosurgical Unit
SooHong Kim, SungUk Yun, MyoungHun Joh and GyeRok Jeon
Department of Biomedical Engineering, School of Medicine, Pusan National University
Department of Biomedical Engineering, Pusan National University Yangsan Hospital, Korea
(Manuscript received 27 June 2017 ; revised 10 August 2017 ; accepted 24 August 2017)
Abstract: Electrosurgical Unit(ESU) is medical equipment that cut or coag tissues using electrical energy. It is used
in hospitals’ outpatient clinic room and operating room. Improper use of an ESU may cause fatal injuries to the
patient, such as burns. So, before using an ESU, make sure that it is supplying enough energy for cut and coag by
measuring the output power and checking the output power cable. In this study, we developed a simple ESU power
measurement system PW100 that allows anyone to check the basic output power. And PW100 can check the state
of the cable associated with the output power before using ESU. Then, we compared the measured output power
of the PW100 with an ESU Analyzer which was commercialized, and compared the performance. In the experiment,
the output power measured by the PW100 was lower value than an ESU Analyzer’s that. However, the PW100’s
output power measured in the 5% error range and showed stable reproducibility by a low %RSD value.
Key words: medical equipment, electrical energy, electrosurgical unit, output power, analyzer
I. 서 론
병원에서는 외래의 간단한 시술부터 수술실의 중대한 수
술까지 의료기기를 통한 여러가지 물리적인 에너지를 사용
하고 있다. 의학과 공학의 발달에 따라 빛, 열, 전기 등 새
로운 에너지를 이용한 시술이 증가 하고 있으며 의료기기
또한 발전되고 있다. 이렇게 체외에서 인체에 에너지를 적
용 하는 의료기기는 과도한 사용으로 때로는 인체에 치명적
인 영향을 줄 수 있다. 그래서 의료기기를 사용하기 전에 기
기에서 발생되는 에너지를 측정하고 교정하여 안전하게 사
용하기 위한 성능평가는 반드시 이루어져야 한다[1]. 이는
의료기기의 예방점검을 통해 환자에게 가해질 수 있는 위험
을 최소화하여 환자의 안전을 최대화하기 위함이다. 그래서
의료기기의 출력 에너지를 측정하고 시스템을 평가하기 위
한 의료용 에너지 자동측정 및 성능평가용 계측기기는 의료
의 질 향상과 환자 안전을 위해 반드시 필요하다[2].
의료용 에너지 중 가장 많이 사용되고 있는 전기에너지를
이용하여 병원의 외래 및 수술실에서 조직을 절개하거나 지
혈을 하는 의료기기로 전기수술기(Electrosurgical Unit,
ESU)가 있다. ESU는 강한 전류에 의해 순간적으로 많은
열이 발생하면 열이 집중된 부위의 조직이 수분과 함께 증
발되어 조직과 조직이 분리되는 절개의 효과를 얻을 수 있
고 설정된 전류를 통해 일정한 열을 발생시켜 조직 내의 수
분을 서서히 증발시킴으로 조직을 굳히는 응고의 효과도 얻
을 수 있다. 이렇게 ESU는 고주파 전류를 사용하여 전력
(watt)과 파형(pulse)의 형태로 많을 열을 통해 절개와 응
고 작용을 한다[3].
ESU의 출력은 두 가지 방식이 있는데 고주파 전류의 한
Corresponding Author : GyeRok Jeon
Department of Biomedical Engineering, School of Medicine,