Top Banner
12

Dyness Portfolio - SolarAdvice · Safe and Reliable IP65 Protection Flexible Size Quick Installation [1] Test conditions: 0.2C Charging/Discharging, @25 C, 80% Dod Model Tower T10

Jun 13, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Dyness Portfolio - SolarAdvice · Safe and Reliable IP65 Protection Flexible Size Quick Installation [1] Test conditions: 0.2C Charging/Discharging, @25 C, 80% Dod Model Tower T10
Page 2: Dyness Portfolio - SolarAdvice · Safe and Reliable IP65 Protection Flexible Size Quick Installation [1] Test conditions: 0.2C Charging/Discharging, @25 C, 80% Dod Model Tower T10
Page 3: Dyness Portfolio - SolarAdvice · Safe and Reliable IP65 Protection Flexible Size Quick Installation [1] Test conditions: 0.2C Charging/Discharging, @25 C, 80% Dod Model Tower T10
Page 4: Dyness Portfolio - SolarAdvice · Safe and Reliable IP65 Protection Flexible Size Quick Installation [1] Test conditions: 0.2C Charging/Discharging, @25 C, 80% Dod Model Tower T10

[1]

Page 5: Dyness Portfolio - SolarAdvice · Safe and Reliable IP65 Protection Flexible Size Quick Installation [1] Test conditions: 0.2C Charging/Discharging, @25 C, 80% Dod Model Tower T10

[1]

Page 6: Dyness Portfolio - SolarAdvice · Safe and Reliable IP65 Protection Flexible Size Quick Installation [1] Test conditions: 0.2C Charging/Discharging, @25 C, 80% Dod Model Tower T10

Model H8025Battery Type LiFePO4

Nominal Energy 2.0kWh

Usable Energy 1.8kWh

Nominal Capacity 25Ah

Nominal Voltage 80V

Maximum Continuous Discharge Power 2kW

Maximum Continuous charge Power 2kW

Net Weight 19Kg

Dimension[W*D*H] 480*434*90mm

Protection Level IP20

Calendar Life 6000 Cycles

Charging Temperature Range

Discharging Temperature Range

Communication CAN

Warranty 10 Years

-10~45 C

0~45 C

[1]

Page 7: Dyness Portfolio - SolarAdvice · Safe and Reliable IP65 Protection Flexible Size Quick Installation [1] Test conditions: 0.2C Charging/Discharging, @25 C, 80% Dod Model Tower T10
Page 8: Dyness Portfolio - SolarAdvice · Safe and Reliable IP65 Protection Flexible Size Quick Installation [1] Test conditions: 0.2C Charging/Discharging, @25 C, 80% Dod Model Tower T10
Page 9: Dyness Portfolio - SolarAdvice · Safe and Reliable IP65 Protection Flexible Size Quick Installation [1] Test conditions: 0.2C Charging/Discharging, @25 C, 80% Dod Model Tower T10
Page 10: Dyness Portfolio - SolarAdvice · Safe and Reliable IP65 Protection Flexible Size Quick Installation [1] Test conditions: 0.2C Charging/Discharging, @25 C, 80% Dod Model Tower T10
Page 11: Dyness Portfolio - SolarAdvice · Safe and Reliable IP65 Protection Flexible Size Quick Installation [1] Test conditions: 0.2C Charging/Discharging, @25 C, 80% Dod Model Tower T10

IP65 Protection Flexible Size Higher EfficiencySafe and Reliable

Model Powercube H48037

17.76kWh

15.1kWh

37Ah

480V

17kW

17kW

235Kg

1218*600*526

IP65

6000 Cycles

H9637

Series

4 5

CAN

10 year

Powercube H38437

14.21kWh

12.1kWh

37Ah

384V

14kW

14kW

190Kg

1040*600*526

IP65

6000 Cycles

H9637

Series

CAN

10 year

Powercube H28837

10.66kWh

9.1kWh

37Ah

288V

10kW

10kW

155Kg

1040*600*526

IP65

6000 Cycles

H9637

Series

3

CAN

10 year

Powercube H19237

7.10kWh

6.1kWh

37Ah

192V

7kW

7kW

120Kg

1040*600*526

IP65

6000 Cycles

H9637

Series

2

CAN

10 year

Nominal energy

Nominal capacity

Nominal voltage

Max. continuousdischarge powerMax. continuouscharge power

Net weight

Dimension [W*D*H]

Protection level

Calendar life

Charging temp. range

Discharging temp. range

Internal battery module

Module connection

Module number

Communication

Warranty

[1] Test conditions: 0.2C Charging/Discharging, @25 C, 80% Dod

Usable energy

0~45 C

-10~45 C

0~45 C

-10~45 C

0~45 C

-10~45 C

0~45 C

-10~45 C

[1]

Page 12: Dyness Portfolio - SolarAdvice · Safe and Reliable IP65 Protection Flexible Size Quick Installation [1] Test conditions: 0.2C Charging/Discharging, @25 C, 80% Dod Model Tower T10

IP65 Protection Flexible Size Quick InstallationSafe and Reliable

[1] Test conditions: 0.2C Charging/Discharging, @25 C, 80% Dod

Model Tower T10 Tower T14 Tower T17 Tower T21Nominal Energy 10.66KWh 14.21KWh 17.76KWh 21.31KWh

Usable Energy 9.1KWh 12.1KWh 15.1KWh 18.1KWh

Nominal Capacity 37Ah 37Ah 37Ah 37Ah

Nominal Voltage 288V 384V 480V 576V

Maximum Continuous Discharge Power 10KW 14KW 17KW 21KW

Maximum Continuous charge Power 10KW 14KW 17KW 21KW

Net Weight 149Kg 192Kg 235Kg 278Kg

Dimension[W*D*H] 800*510*510mm 988*510*510mm 1360*510*510mm

Protection Level IP65 IP65 IP65 IP65

Calendar Life 6000 Cycles 6000 Cycles 6000 Cycles 6000 Cycles

Charging Temperature Range

Discharging Temperature Range

Internal Battery Module T9637 T9637 T9637 T9637

Module Connection series series series series

Module Number 3 4 5 6

Communication CAN CAN CAN CAN

Warranty 10 Years 10 Years 10 Years 10 Years

1175*510*510mm

-10~45 C

0~45 C

-10~45 C

0~45 C

-10~45 C

0~45 C

-10~45 C

0~45 C

[1]