DVW SERIES UNITED ELECTRIC COMPANY, L.P. 501 Galveston St. • Wichita Falls, Texas 76301 • 940-397-2100 • Fax 940-397-2166 DVW 2.3 www. magicaire.com PER 02/02 6M VERTICAL DIRECT DRIVE CHILLED WATER AIR UNITS MAGIC AIRE DVW SERIES FAN COILS ARE ETLC LISTED IN ACCORDANCE WITH UL 1995 AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY. OPTIONAL ACCESSORIES Two Row Hot Water Coil
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1 DVW 2.3
DVW SERIES
UNITED ELECTRIC COMPANY, L.P.501 Galveston St. • Wichita Falls, Texas 76301 • 940-397-2100 • Fax 940-397-2166
DVW 2.3 www. magicaire.com PER 02/02 6M
VERTICAL DIRECT DRIVECHILLED WATER AIR UNITS
MAGIC AIRE DVW SERIES FAN COILS ARE ETLCLISTED IN ACCORDANCE WITH UL 1995AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY.
DVW with VH-2CFM vs. External Static for Standard Unit with Hot Water Coil
DVW SeriesAIR FLOW
Page 4 DVW 2.3
Page 5 DVW 2.3
Page 6 DVW 2.3
DVW Series
Page 7 DVW 2.3
DVW SeriesVERTICAL HOT WATER SECTION
SIDE FRONT
LEDOM A B C D E F G H GNIPPIHSSTHGIEW
2-004-HV 5.31 61 51 5.21 0.42 00.32 6 01 72
2-006-HV 5.31 61 51 5.21 0.42 00.32 6 01 72
2-008-HV 5.31 61 51 5.21 0.42 00.32 6 01 72
2-0001-HV 5.31 61 51 5.31 5.92 52.82 6 01 63
Hot Water Section Cabinet Dimensions
Two Row Coil Heating Capacities
The Hot Water Coils are to be field installed on the discharge side of the unit. When the hot water coils section is placed on top ofthe DVW or DVX unit, a flange will extend down over the unit on each side. Two screws should be placed in each of these twoflanges to secure the hot water coil section to the unit.
Capacities calculated and based on entering air temperatures of 60 degrees.Units not recommended for heating applications when leaving air exceeds 140 degrees.
Page 8 DVW 2.3
UNITED ELECTRIC COMPANY, L.P.501 Galveston St. • Wichita Falls, Texas 76301 • 940-397-2100 • Fax 940-397-2166
DVW 2.3 www. magicaire.com PER 02/02 6M
MAGIC AIRE DVW SERIES FAN COILS ARE ETLCLISTED IN ACCORDANCE WITH UL 1995AND ARE ASSEMBLED TO ORDER FOR COMPETITIVE DELIVERY.
1. Aluminum fin-copper tube coils.2. Direct drive blowers.3. Forward curve blower wheels factor balanced.4. Motors have overload protection.5. Fully insulated with 3/4” fiberglass with an R value
equal to 3.26.6. 1” throwaway filters are standard on all units.7. DVW units have duct connections on return
air inlet.8. Large blower access panel on front.9. Header connections are located on front left hand
side (when looking with airflow).
NOTICE: When Magic Aire® coils are used withground or well water, the water must be free of sandor other contaminants. Magic Aire will not be re-sponsible nor liable for any kind of damages incurredby the ground or well water systems which containsand or any other corrosive contaminants. Contactthe factory for further information.