Duct numbering for EE-

Wolfgang Funk - CERN CMS30/07/2004

06.B

06.A07.B

07.A

08.B

08.A09.B

09.A

10.B

10.A

11.B

11.A

12.B 12.A

13.B13.A

14.B14.A

1

Page 2: Duct numbering for EE- Wolfgang Funk - CERN CMS 30/07/2004 06.B 06.A07.B 07.A 08.B 08.A 09.B 09.A 10.B 10.A 11.B 11.A 12.B12.A 13.B 13.A 14.B 14.A 1.

Wolfgang Funk - CERN CMS30/07/2004

Duct 05.A

Duct 05.B

LV1 4*7.4 (172)LV2 4*6.1 (120)HV 1*15.3 (184)OF 3*4.3X2 (27)signal 1*9 (64)

LV1 4*7.4 (172)LV2 4*6.1 (120)HV 1*15.3 (184)OF 2*4.3X2 (18)signal 1*9 (64)

Bret

OF 15*4.3X2 (129)HV 4*14 (616)Sniff 1*6 (29)

P F

Pret

LV 10*12.2 (1169)CO 1*14 con (154)

Signal 1*10 (79)

CO 1*14 is (314mm**2)CO 1*14 con (154)

N2 1*8 (51)

sn N2

Sum: (1960)

Sum: (1860)

Similar to Duct 03.B

Similar to Duct 03.A

View towards I.P. for EE+

View from I.P. for EE-

Duct 06.B

Duct 06.A

2

Note that the EE HV cables are only the indicated size where there is no space problem. The mantle is cut off elsewhere (curves) and saves almost 60% of cross section.

Page 3: Duct numbering for EE- Wolfgang Funk - CERN CMS 30/07/2004 06.B 06.A07.B 07.A 08.B 08.A 09.B 09.A 10.B 10.A 11.B 11.A 12.B12.A 13.B 13.A 14.B 14.A 1.

Wolfgang Funk - CERN CMS30/07/2004

Duct 04.A

Duct 04.B

LV1 4*7.4 (172)LV2 4*6.1 (120)HV 1*15.3 (184)OF 5*4.3X2 (45) signal 1*9 (64)

LV1 8*7.4 (344)LV2 8*6.1 (240)HV 2*15.3 (368) signal 2*9 (128)

P FP ret

HV 4*14 (616)CO 1*14 is (314)

OF 15*4.3X2 (129)

LV 10*12.2 (1169mm**2)CO 1*14 con (154)

Signal 1*10 (79)

P F Sum: (2149)

Sum: (1987)

Similar to Duct 02.A

Similar to Duct 02.B

Duct 07.B

Duct 07.A

3

Page 4: Duct numbering for EE- Wolfgang Funk - CERN CMS 30/07/2004 06.B 06.A07.B 07.A 08.B 08.A 09.B 09.A 10.B 10.A 11.B 11.A 12.B12.A 13.B 13.A 14.B 14.A 1.

Wolfgang Funk - CERN CMS30/07/2004

Duct 03.A

Duct 03.B

LV1 4*7.4 (172)LV2 4*6.1 (120)HV 1*15.3 (184)OF 5*4.3X2 (45)signal 1*9 (64)

LV1 4*7.4 (172)LV2 4*6.1 (120)HV 1*15.3 (184)OF 3*4.3X2 (27)Signal 1*9 (64)

OF 15*4.3X2 (129)HV 2*14 (308)

LV 10*12.2 (1169)CO 1*14 con (154)

Signal 1*10 (79)

CO 4*10 is (804mm**2)CO 1*14 is (314)CO 1*12 is (255)CO 1*14 con (154)

OESR

P FP ret

BF BF BF BF OESF

FES F

Sum: (1969)

Sum: (2549)

Similar to Duct 05.B

Similar to Duct 05.A

Duct 08.B

Duct 08.A

4

Page 5: Duct numbering for EE- Wolfgang Funk - CERN CMS 30/07/2004 06.B 06.A07.B 07.A 08.B 08.A 09.B 09.A 10.B 10.A 11.B 11.A 12.B12.A 13.B 13.A 14.B 14.A 1.

Wolfgang Funk - CERN CMS30/07/2004

Duct 02.A

Duct 02.B

LV1 4*7.4 (172)LV2 4*6.1 (120)HV 1*15.3 (184)OF 2*4.3X2 (18)signal 1*9 (64)

PE 1*3.6 (10)LV1 8*7.4 (344)LV2 8*6.1 (240)HV 2*15.3 (368)OF 4*4.3X2 (36)signal 2*9 (128)

P FP ret

LV 10*12.2 (1169mm**2)CO 1*14 con (154)

Signal 1*10 (79)

CO 2*14 is (628)Laser 1*10 (79)

OF 15*4.3X2 (129)Co 1*14 (154)

P F

MEM 24*2.2 (92)MEM 4*1.5X2 (12)MEM 6*2X10 (120)

Note: additional cables between MEM and balconies: Hybrid (5V,2.5V Ving, sensing for all) 2*12.3 (238), OF 2*4.3X2 (18) MEM cables (MEM 24*2.2 (92), MEM 4*1.5X2 (12) and MEM 6*2X10 (120) )are only between MEM and Dees

Sum: (2340)

Sum: (2403)

Sum: (2122)

Similar to Duct 04.B

Similar to Duct 04.A

DCS 1*11 (95)DCS 1*7.2 (41)DCS 1*5.8 (26)

Duct 09.B

Duct 09.A

5

P F retB ret

Note: PE is only in in 9A-/2B+ for ES and not in 18A-/11B+

Page 6: Duct numbering for EE- Wolfgang Funk - CERN CMS 30/07/2004 06.B 06.A07.B 07.A 08.B 08.A 09.B 09.A 10.B 10.A 11.B 11.A 12.B12.A 13.B 13.A 14.B 14.A 1.

Wolfgang Funk - CERN CMS30/07/2004

Duct 01.A

CO 1*71 (3960)

Duct 10.B

6

Page 7: Duct numbering for EE- Wolfgang Funk - CERN CMS 30/07/2004 06.B 06.A07.B 07.A 08.B 08.A 09.B 09.A 10.B 10.A 11.B 11.A 12.B12.A 13.B 13.A 14.B 14.A 1.

Wolfgang Funk - CERN CMS30/07/2004

Duct 01.B

CO 1*71 (3960)

Duct 10.A

7

Page 8: Duct numbering for EE- Wolfgang Funk - CERN CMS 30/07/2004 06.B 06.A07.B 07.A 08.B 08.A 09.B 09.A 10.B 10.A 11.B 11.A 12.B12.A 13.B 13.A 14.B 14.A 1.

Wolfgang Funk - CERN CMS30/07/2004

Duct 18.B

LV1 4*7.4 (172)LV2 4*6.1 (120)HV 1*15.3 (184)OF 2*4.3X2 (18)signal 1*9 (64)

P FP ret

LV 10*12.2 (1169mm**2)CO 1*14 con (154)

Signal 1*10 (79)

Sum: (2122)

Similar to Duct 16.B

Duct 11.A

Duct 18.A

CO 2*14 is (628)Co 1*14 (154)

P F

HV 4*14 (616)OF 15*4.3X2 (129)

Sum: (2652)

Similar to Duct 16.A

Duct 11.B

8

P F

LV1 8*7.4 (344)LV2 8*6.1 (240)HV 2*15.3 (368)OF 5*4.3X2 (45)signal 2*9 (128)

DCS 1*11 (95)DCS 1*7.2 (41)DCS 1*5.8 (26)

retB ret

Page 9: Duct numbering for EE- Wolfgang Funk - CERN CMS 30/07/2004 06.B 06.A07.B 07.A 08.B 08.A 09.B 09.A 10.B 10.A 11.B 11.A 12.B12.A 13.B 13.A 14.B 14.A 1.

Wolfgang Funk - CERN CMS30/07/2004

Duct 17.A

LV1 4*7.4 (172) LV2 4*6.1 (120)HV 1*15.3 (184)OF 3*4.3X2 (27)Signal 1*9 (64)

LV 10*12.2 (1169)CO 1*14 con (154)

Signal 1*10 (79)

P FP ret Sum: (1969)

Similar to Duct 15.A

Duct 12.B

Duct 17.B

LV1 4*7.4 (172)LV2 4*6.1 (120)HV 1*15.3 (184)OF 5*4.3X2 (45)signal 1*9 (64)

CO 4*10 is (804mm**2)CO 1*14 is (314)CO 1*12 con (113)CO 1*14 con (154)

OESRBF BF BF BF OES

FSum: (2407)

Similar to Duct 15.B

Duct 12.A

FES R

9

OF 15*4.3X2 (129)HV 2*14 (308)

Page 10: Duct numbering for EE- Wolfgang Funk - CERN CMS 30/07/2004 06.B 06.A07.B 07.A 08.B 08.A 09.B 09.A 10.B 10.A 11.B 11.A 12.B12.A 13.B 13.A 14.B 14.A 1.

Wolfgang Funk - CERN CMS30/07/2004

Duct 16.A

LV1 8*7.4 (344)LV2 8*6.1 ( 240)HV 2*15.3 (368) signal 2*9 (128)

P F Sum: (2139)

Similar to Duct 18.A

Duct 13.B

Duct 16.B

LV1 4*7.4 (172)LV2 4*6.1 (120)HV 1*15.3 (184)OF 5*4.3X2 (45) signal 1*9 (64)

P FP ret

LV 10*12.2 (1169mm**2)CO 1*14 con (154)

Signal 1*10 (79)

Sum: (1987)

Similar to Duct 18.B

Duct 13.A

10

HV 4*14 (616)CO 1*14 is (314)

OF 15*4.3X2 (129)

Page 11: Duct numbering for EE- Wolfgang Funk - CERN CMS 30/07/2004 06.B 06.A07.B 07.A 08.B 08.A 09.B 09.A 10.B 10.A 11.B 11.A 12.B12.A 13.B 13.A 14.B 14.A 1.

Wolfgang Funk - CERN CMS30/07/2004

Duct 15.A

LV1 4*7.4 (172)LV2 4*6.1 (120)OF 2*4.3X2 (18)signal 2*9 (128)

14/23

Pret

LV 10*12.2 (1169)CO 1*14 con (154)

Signal 1*10 (79)

Sum: (1840)

Similar to Duct 17.A

Duct 14.B

Duct 15.B

LV1 2*7.4 (86)LV2 2*6.1 (60)HV 1*15.3 (184)OF 2*4.3X2 (18)signal 1*9 (64)

Bret

HV 6*14 (924)OF 15*4.3X2 (129)

Sniff 1*6 (29)

P F

CO 1*14 is (314mm**2)CO 1*14 con (154)

N2 1*8 (51)

sn

N2Sum: (2126)

Similar to Duct 17.B

Duct 14.A

N2/sniff 1*12 (113)

N2

Note: ES N2 pipe is input on one Dee and output on other Dee (same diameter)

11

Note: in 14B-/15A+ for ES only LV2 2*6.1 and not 4! whereas in 5B-/6A+ LV2 4*6.1 existent

Note: in the ducts 14B-/15A+/5B-/6A+ ES LV1 and ES LV2 all cables run to counting room since used for heating

Page 12: Duct numbering for EE- Wolfgang Funk - CERN CMS 30/07/2004 06.B 06.A07.B 07.A 08.B 08.A 09.B 09.A 10.B 10.A 11.B 11.A 12.B12.A 13.B 13.A 14.B 14.A 1.

History

Wolfgang Funk - CERN CMS30/07/2004 12

1. Move ES services out of 10B-/10A- into 9A-/11B- (no space in ducts with ES pipes).2. Move PF from 7A- to 9A- and from 13B- to 11B- to avoid crossing of cooling pipe over

ring flange bean.3. Move half of OF from 6B-/8B-/13B-/11B- to 7A-/9A-/14A-/12A- to have less crossings.4. Move half of HV from 7A-/9A-/14A-/12A- to 6B-/8B-/13B-/11B- to have less crossings.5. Change of DCS scheme: no DCS cable anymore in 7B-/13A-, but 3 DCS cables in

9B-/11A-, no overall cross section increase.

New version 14/7/03 to avoid crossing of services at EE patch panel area according to Justin’s proposal of patch panel design of spring ’03:

New version 6/8/03 to increase LV cable sets to 20/Quadrant (before 18/Quadrant) because of new “EE-mechatronics’’ design of Tony:

1. 2 more LV EE cables each in ducts 7B-,9B-,11A-,13A- .

New version 11/8/03 to increase space in ducts for ES cooling pipes.

1. Move EE backplate return pipes from 10B-/10A- into 9A-/11B- .

Page 13: Duct numbering for EE- Wolfgang Funk - CERN CMS 30/07/2004 06.B 06.A07.B 07.A 08.B 08.A 09.B 09.A 10.B 10.A 11.B 11.A 12.B12.A 13.B 13.A 14.B 14.A 1.

History(2)

Wolfgang Funk - CERN CMS30/07/2004 13

1. Remove one OF from of 9A-.2. Remove separate LV cables for controls 14A- (are part of standard LV system)

New version 23/9/03 to adapt latest version of ES services:

New version 03/12/03 to adapt latest version of EE/ES services:

1. One ES unit contains now only one signal- (control) cable instead of 2 with exception of duct 14B-.2. One ES LV unit contains now of 4*7.4 and 4*6.1 instead of 6*7.43. MEM services adopted to new information4. EE HV 2*13 mantles/Dee (each has 13/12 coax) replaces single coaxes, changed some positions to equalize filling factors.

New version 2/03/04 to adapt latest version of EE/ES services:

1. In 14B- ES now only 2 LV 6.1mm instead of 4 (but not other Dee (5B-), where are still 4)2. In 14A- ES only 2 LV 6.1mm and 2 LV 7.4mm instead of 4 each before3. Only 4 signal cables/Quadrant for EE instead of 6 before4. One more optical fiber in all ducts where there was a fiber for ES (spare)

Page 14: Duct numbering for EE- Wolfgang Funk - CERN CMS 30/07/2004 06.B 06.A07.B 07.A 08.B 08.A 09.B 09.A 10.B 10.A 11.B 11.A 12.B12.A 13.B 13.A 14.B 14.A 1.

History(3)

Wolfgang Funk - CERN CMS30/07/2004 14

1. 4 less OF spares/ Dee than before.2. Implement 1 OF spare per double MEM3. Implement 1 protection conductor per ES disk

New version 30/7/04 to adapt latest version of ES/EE services: