> Ventilation Air Conditioning Refrigeration Heating 22 º C Inside OUTSIDE HUMIDITY PROVIDED BY HEINEN & HOPMAN 35 C 90% PRODUCTS Duct fan WMR
>
Ventilation Air Conditioning RefrigerationHeating
22ºCInside
OUTSIDEHUMIDITY
PROVIDED BYHEINEN & HOPMAN
35 C
90%
productsduct fan WMr
To stand by our clients in the harshest environments
“ “
Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.
Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.
WMR ducT fan
applicationMarine duct fans WMR are destined for operation in ventilation systems of seagoing of unrestricted cruising area as well as offshore objects.
Temperature of conveyed medium must not exceed +45 0C, dust content 0.3g/m3. design features• Made of steel or plastic, with epoxy coating• Speed-controllable using optional solid-state speed control• Fans can be used to supply or exhaust air• Fans can be installed horizontally and vertically• Fans can be installed in flexible or rigid duct• Extensive range of accessories constructionCasing and impeller are made of PA2 aluminum sheets, welded. A terminal box with G20 cable gland, for feeding cable connection, is fitted on the casing. Electric motor: induction, squirrel-type, 3-phase, IP55 enclosure, in marine execution.
classification
dimensions Duct ventilation 1-phase and 3-phase
Type DN ØD L H E F V / Hz
WMR 100 / L 100 244 290 175 35 25 230 / 50 - 60
WMR 125 / L 125 264 315 185 35 25 230 / 50 - 60
WMR 160 / L 160 338 340 225 35 25 230 / 50 - 60
WMR 200 / M 200 338 400 225 40 30 230 / 50 - 60
WMR 200 / L 200 418 400 266 40 30 230 / 50 - 60
Dimensions in mm
Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.
Type WMR 100 / L WMR 125 / L WMR 160 / L WMR 200 / M WMR 200 / L
Nominal diameter (mm) 100 125 160 200 200
Power consumption (kW)
0.05 0.07 0.13 kW 0.21 kW 0.40
Electric motor- Type- Rated power (kW)- Rated current (A)- Revolution (min-1)- Supply (V / Hz)- Weight (kg)- Noise level (dB[A])
mSg56-2A
0.090.322800
3x380 / 504.455
mSg56-2B
0.120.352800
3x380 / 505.058
mSg63-2A
0.180.552760
3x380 / 507.862
mSg63-2B
0.250.652760
3x380 / 509.363
mSg71-2B
0.551.352790
3x380 / 501465
Power consumption (kW)
0.07 0.10 0.21 0.28 0.59
Electric motor- Type- Rated power (kW)- Rated current (A)- Revolution (min-1)- Supply (V / Hz)- Weight (kg)- Noise level (dB[A])
mSg56-2A
0.110.353380
3x440 / 604.456
mSg56-2B
0.140.353380
3x440 / 605.059
mSg63-2B
0.290.653330
3x440 / 607.863
mSg63-2A
0.431.003400
3x440 / 609.664
mSg71-2B
0.641.353400
3x440 / 601466
WMR (3-phase) specifications
Performance chart (50Hz and 60Hz)
Alternatives available on request.Due to continued product development, Heinen & Hopman reserves the right to introduce alternations without prior notice.
Type WMR 100 / L WMR 125 / L WMR 160 / L WMR 200 / M WMR 200 / L
Nominal diameter (mm) 100 125 160 200 200
Power consumption (kW)
0.05 0.07 0.13 kW 0.21 kW 0.40
Electric motor- Type- Rated power (kW)- Rated current (A)- Revolution (min-1)- Supply (V / Hz)- Weight (kg)- Noise level (dB[A])
mSEg56-2A
0.090.852860
1x220 / 504.455
mSEg56-2B
0.121.0
28601x220 / 50
5.058
mSEg63-2A
0.181.5
28201x220 / 50
7.862
mSEg63-2B
0.251.852850
1x220 / 509.363
mSEMg71-2C
0.554.0
28001x220 / 50
1465
Power consumption (kW)
0.07 kW 0.10 kW 0.21 kW 0.28 kW 0.59 kW
Electric motor- Type- Rated power (kW)- Rated current (A)- Revolution (min-1)- Supply (V / Hz)- Weight (kg)- Noise level (dB[A])
mSEg56-2A
0.111.0
34301x220 / 60
4.456
mSEg56-2B
0.141.153430
1x220 / 605.059
mSEg63-2B
0.291.753380
1x220 / 607.863
mSEg63-2C
0.432.453400
1x220 / 609.564
mSMg71-2C
0.644.6
34001x220 / 60
1466
centrifugal WMR (1-phase) duct fan specifications
Performance chart (50Hz and 60Hz)
www.heinenhopman.com
Heinen & Hopman encourages a more
sustainable world. By providing eco-friendly solutions and serviceswe offer our clients
the option of reducing energy consumption
and thus co2 emissions. Visit
greenmanifest.info for more information.
BrazilT: +5521 3587 4241/4244E: [email protected]
france - La ciotatT: +334 4204 8685E: [email protected]
france - GrasseT: +336 3090 7786 E: [email protected]
GermanyT:+49 4073 1680E: [email protected]
IndiaT: +9133 6499 1293E: [email protected]
ItalyT: +3901 8745 7970E: [email protected]
The netherlands (HQ)T: +313 3299 2500E: [email protected]
The netherlands (Rotterdam)T: +317 8890 8050E: [email protected]
norwayT: +47 6919 0900E: [email protected]
Peoples Republic of chinaT: +8621 3253 2896E: [email protected]
Peoples Republic of chinaT: +86 510 8528 1763E: [email protected]
PolandT: +489 1433 1800E: [email protected]
RomaniaT: +402 3644 8222E: [email protected]
RussiaT: +7 (4012) 308 801E: [email protected]
SingaporeT: +65 6897 7879E: [email protected]
South KoreaT: +8270 4901 0000E: [email protected]
SpainT: +349 3225 9668E: [email protected]
SwedenT: +46 3121 7500E: [email protected]
TurkeyT: +9021 6493 8118E: [email protected]
uaE (abu dhabi) T:+971 2550 4147E: [email protected]
uaE (dubai)T: +971 4263 5453E: [email protected]
uSa - fort Lauderdale, floridaT: +195 4463 0110E: [email protected]
uSa - Houma, Louisiana T: +198 5876 7989E: [email protected]