Top Banner
DT601/ID DT601F/ID RF CARD RF CARD English User Manual 2-Wire Video Outdoor Station DT-ENG-601(F)ID-V2 141122
16

DT601(F)/ID User Manual

Jan 05, 2017

Download

Documents

dangkhue
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: DT601(F)/ID User Manual

DT601/ID DT601F/ID

RF CARD RF CARD

English

User Manual

2-Wire Video Outdoor Station

DT-ENG-601(F)ID-V2 141122

Page 2: DT601(F)/ID User Manual
Page 3: DT601(F)/ID User Manual

Contents

1.Parts and Functions............................................................................................. 1

2.Terminal Descriptions .......................................................................................... 1

3.Door Station Mounting ......................................................................................... 2

4. System Wiring and Electric Lock Connection ..................................................... 4

5. ID Card Registration ........................................................................................... 8

6.Unlock Operations ............................................................................................... 10

7.ID Setting of Door Station .................................................................................... 10

8. Precaustions ....................................................................................................... 11

9. Specifications ..................................................................................................... 11

10. Cables Requirements ....................................................................................... 12

Page 4: DT601(F)/ID User Manual

Side View Mounting box

ID card window

Rainy Cover

DT601/KP

Camera Lens

Speaker

NameplateCall Button

Microphone

93 mm

182

mm

Night Light

RF CARD ID card window RF CARD

30 mm

DT601F/ID

220

mm

120 mm

RF CARD

Camera Lens

Speaker

NameplateCall Button

Microphone

Night Light

Screws for panel mounting

RF CARD

1.Parts and Functions

2.Terminal Descriptions

1 2

3

Lock Control Jumper

BUS PL S+ S-Main Connect Port

-1-

Page 5: DT601(F)/ID User Manual

3.Door Station Mounting

1 2

43

Drill holes in the wall to match the size of screws and attach the rainy cover to the wall.

Attach the panel to the rainy cover Use the screwdriver and the screw to fix the panel

Connect the cable correctly

DT601/ID Mounting

-2-

• Lock Control Jumper: To select the lock type.

• Main Connect Port: To connect the bus line and the electronic locks. • BUS: Connect to the bus line, no polarity. • PL: External lock power input, connect to the power positive(power +). • S+: Lock power(+) output. • S-: Lock power(-) output, connect to the power(-) input of locks(only when using the door

station to power the locks, if using the external power supply for the locks, the S- will not be connected).

Page 6: DT601(F)/ID User Manual

DT601F/ID Mounting

1 2

43

Drill a hole in the wall to match the size of the mounting box and attach to the wall.

Attach the panel to the mounting box and use screws supplied to fix the panel

Connect the cable correctly

Placing Name Label

AcDbMLeader (ACDB_MLEADER_CLASS)

AcDbMLeader (ACDB_MLEADER_CLASS)

-3-

Use a screwdriver to unscrew the screw, and cock the host , then Placing Name Label.

Page 7: DT601(F)/ID User Manual

4. System Wiring and Electric Lock Connection

Basic Connection

BUS(IM) BUS(DS)

PC6

AC~

-

+

L1 L2 PL S+ S-

Doorbell Button

Switch

1 2

3

ONDIP

S

-4-

Electric Lock Connection

Door Lock Controlled with Internal Power

Note:

1. Electronic lock of Power-on-to-unlock type should be used.

2. The door lock is limited to 12V, and holding current must be less than 250mA.

3. The door lock control is not timed from Exit Button(EB).

4. The Unlock Mode Parameter of Monitor must be set to 0 (by default).

EB*LOCK

BUS PL S+ S-

Jumper position in 2-3

1 2 3

Page 8: DT601(F)/ID User Manual

Unlock parameter setting(set on monitor)

LOCK

Take off the Jumper

POWER SUPPLY

BUS PL S+ S-

-5-

Door Lock Controlled with Dry Contact

Note:

1. The external power supply must be used according to the lock.

2. The inside relay contact is restricted to AC or DC 24V/1A.

3. The jumper must be taken off before connecting.4. Setup the Unlock Mode of Monitor for

different lock types.

• Power-on-to-unlock type:Unlock Mode=0 (by default)

• Power-off-to-unlock type:Unlock Mode=1

Note:1.must connect DT601(F)/ID correctly before setting.2.the parameter will be saved in DT601(F)/ID automatically, so you need only set on one monitor.3.Here we take DT47M(the monitor) for example, please refer to the corresponding user manual.

1.Touch icon on main menu page.

2.Touch UNLOCK button and hold for 2s.

3.A digital keypad will be shown.

About Local Address 00.00

Video Standard AUTO

System Verson 00.01.00

Display Driver 1.0

Front 1.0

UI 1.0

INSTALLER SETUP 123 _

Page 9: DT601(F)/ID User Manual

-6-

Multi Door Stations Connection

100~240VAC

DBC4A

A B C D

OFF

ON

Impedance switch

BUS(IM) BUS(DS)

PC6

AC~

1# Camera2# Camera3# Camera4# Camera

L1 L2 PL S+ S-L1 L2 PL S+ S-L1 L2 PL S+ S-L1 L2 PL S+ S-

(Device Address:3) (Device Address:2) (Device Address:1) (Device Address:0)

Basic IN-OUT Wiring Mode

Multi Monitors Connection

RF CARD

Code=14Code=15

(Device Address:0)

BUS(IM) BUS(DS)

PC6

AC~

100~240VAC

Code=0

NOTE:Here we take DT47M(the monitor) for example.

Page 10: DT601(F)/ID User Manual

With DBC4A Wiring Mode

RF CARD

Code=0

OFF ON

OFF ON

DBC4

A

A B

C D

DBC4

A

A B

C D

Impedance switch

Impedance switch

(Device Address:0)

NOTE:Here we take DT47M(the monitor) for example.

100~240VAC

BUS(IM) BUS(DS)

PC6

AC~

Code=2

Code=1

Code=3

Code=12

Code=14

Code=13

Code=15

-7-

Page 11: DT601(F)/ID User Manual

5. ID Card RegistrationIntroduction:

• Up to 320 user cards can be registered by the door station. • Easy management with LED status and sound hints. • There are two master cards, one MASTER CARD ADD card and one MASTER

CARD DELETE card, When registered new master cards, the old master cards are invalid automatically.

• Card reading distance is from 3 to 5 cm. • The master cards are necessary when you add or delete user cards. Please

keep it well for future use.

-8-

Authorize master cards:

The color of background indicator

beep+ beep+,beep beep+,beep

Press and hold the Call Button to power-on.("Beep+",means that enter the setting state)

Press and hold again the Call Button 3 seconds.

Press and hold the Call

Button 3 seconds.(At this time press the Call Button will to start the aging function)

(blue)

The color of background indicator

The color of background indicator

(white)

Notice:it will return to standby mode if no operation within 10s.Or press Call Button to exit the state of setting and start to call the monitor(except step 3).

(blue)

beep+

The color of background indicator

(yellow)

Show the first card to ID card window, it will be set to MASTER CARD ADD card.

beep+

The color of background indicator

(blue)

Show the second card to ID card window, it will be set to MASTER CARD DELETE card.

By default,there are two master cards marked MASTER CARD ADD and MASTER CARD DELETE ,but you should know that the master card can be authorized by users at any time.That means any two user cards can be authorized to master cards,When registered new master cards, the old master cards are invalid automatically.

Page 12: DT601(F)/ID User Manual

-9-

Access Initialization (delete all user cards):

Show the MASTER CARD

DELETE card to ID card window in standby mode.

Show the MASTER CARD

ADD card to ID card window.(At this time show the MASTER CARD DELETE,it will return to the "Delete User Cards" state)

Show the MASTER CARD

ADD card to ID card window again,format operation is performing.

The color of background indicator

beep+,beep beep+(yellow)

The color of background indicator

The color of background indicator

(green blink)(red)beep+,beep

Add User Cards:

The color of background indicator

beep+,beep beep+ beep,beep+

Show the MASTER CARD

ADD card to ID card window in standby mode.

Show user cards to be added, one by one.

Show the MASTER CARD

ADD card to exit.

(white)

The color of background indicator

(green blink one time)

The color of background indicator

(blue)

Delete User Cards:

Notice:it will return to standby mode if no operation within 10s .Or press Call Button to exit the status of setting and start to call the monitor.

The color of background indicator

beep+,beep beep+ beep,beep+

Show the MASTER CARD

DELETE card to ID card window in standby mode.

Show user cards to be deleted in sequence

Show the MASTER CARD

DELETE card to exit.

(yellow)

The color of background indicator

(green blink one time)

The color of background indicator

(blue)

Notice:it will return to standby mode if no operation within 20s.Or press Call Button to exit the status of setting and start to call the monitor.

Page 13: DT601(F)/ID User Manual

-10-

Notice:1.Automatically returns to standby mode after FORMAT completed. 2.It will return to standby mode if no operation within 20s.Or press Call Button to exit the status of setting and start to call the monitor.

1. If show the authorized user card,the buzzer will sound of beep+,and the LED background indicator will light up.

2. If show the unauthorized user card,the buzzer will sound of beep,beep,beep.

6.Unlock Operations

When the registered user card has been shown to ID card window, the LED background indicator lights up, the buzzer sounds,and the electric door strike is unlocked.

Unlocking of ID Card

7.ID Settings of Door Station

The color of background indicator

beep+,beep

beep

Press the Call Button 3 seconds.(At this time press the Call Button will to exit the setting,and start calling)

Press again the Call Button 3 seconds.

(white)

The color of background indicator

(ID0:cyan)(ID1:green)(ID2:yellow)(ID3:red)

beep,beepbeep,beep,beepbeep,beep,beep,beep

The ID of door station will circulate at ID0 ID1 ID2 ID3.

At this time press the Call Button .

beep+,beep

If no operation within 5s,or press the Call Button 3 seconds,it will exit the setting.

Page 14: DT601(F)/ID User Manual

8. Precaustions

9. Specifications

• Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent. If necessary, please use a little pure water or dilute soap water to clean the dust.

• The unit is weather resistant. However do not spray high pressure water on access control keypad directly. Excessive moisture may cause problems with the unit.

• You must use the right adaptor which is supplied by the manufacture or approved by the manufacture.. • Pay attention to the high voltage inside the products, please refer service only to a trained and qualified

professional.

• Power Supply : DC 24V (supplied by PS4-24V or PS5-24V); • Power Consumption: Standby 40mA; Working status 160mA; • Camera: Color ARS; 420 TV Lines; • Lock Power supply: 12Vdc, 280mA(Internal Power); • Number of relay circuits: 2(the second lock need external device to support) • Mounting: Surface mounting(DT601/ID)

Flush mounting (DT601F/ID) • Working temperature: -15ºC ~ +55ºC • Wiring: 2 wires,non-polarity • Dimension: 182(H)×93(W)×44(D)mm(DT601/ID)

220(H)×120(W)×50(D)mm(DT601F/ID)

-11-

Page 15: DT601(F)/ID User Manual

-12-

RF CARD

The farest monitor

B

A

C

DBC4Amonitormonitor

monitor

with two or four monitors

100~240VAC

BUS(IM) BUS(DS)

PC6

AC~

10. Cables RequirementsThe maximum distance of the wiring is limited in the DT system. Using different cables may also affect the maximum distance which the system can reach.

When Monitor quantity < 20

Cable Usage A B C

Twisted cable 2x0.75 mm2 60 60 30

Twisted cable 2x1 mm2 80 80 40

When Monitor quantity > 20

Cable Usage A B C

Twisted cable 2x1 mm2 70 30 20

Twisted cable 2x1.5 mm2 70 50 30

Note:If the monitor has been specified the distance,refer to the parameter.

Page 16: DT601(F)/ID User Manual

The design and specifications can be modified without notice to the user. Right to interpret and copyright of this manual are reserved.

DT-ENG-601(F)ID-V2 141122