Intrusion Systems | DS7220V2 Control Panel The DS7220V2 has eight zones expandable to 24, four outputs expandable to 12, and two areas. It is suitable for commercial burglary and residential fire/burglary applications. System Overview 4 7 6 8 5 1 2 3 9 10 12 13 14 11 15 DS7220V2 Control Panel ▶ Eight on-board zones ▶ Eight programmable Skeds ▶ RF compatibility ▶ Up to 32 users with optional keyfob operation available ▶ Four programmable authority levels ▶ Two communications routing destinations ▶ 254 event log ▶ Remote-programmable with RPS-INTL ▶ Optional Door Access Control Module (DACM) ▶ Network communication option (LAN/WAN) www.boschsecurity.com
4
Embed
DS7220V2 Control Panel - Bosellbosell.com.tr › Assets › Documents › DS7220V2Control_DataSheet...2011/05/21 · 1. DS7445i LED Keypad 2. DS7445V2 LED Keypad 3. Door Access Control
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Intrusion Systems | DS7220V2 Control Panel
The DS7220V2 has eight zones expandable to 24, fouroutputs expandable to 12, and two areas. It is suitable forcommercial burglary and residential fire/burglaryapplications.
System Overview
ON
1 2 3 4 5 6
+OUT - TMPR R B G Y 1 COM 2 3 COM 4 5 COM 6 7 COM 8
ON
OFF
12345678
12345678 O
N
1
2
3
4
ON
SER
RxTx
BUS
Rx Tx
LED
ENABLE
DB9 GND
ENABLE
P1
P6
P2
BG
YR
P3
18
VA
CD
ata
GR
NY
EL
-+
Au
x/D
ata
RY
GB
BA TT+
BA TT - ALRM
+PO1
L-1SMK
+ L-2COM L-4COML-3 L-6COML-5 L-8COML-7
T
T1
R1
AUXILIAR Y
INS
TA
LL
ER
PO1 SELECT
12
VD
C
+
PO
4
PO
3
PO
2
Au
x P
ow
er
-
A B
RST ATUS
4
7
6
8
5
1 2 3
9
10
12
13
14
11
15
SER
RxTx
BUS
Rx Tx
LED
ENABLE
DB9 GND
ENABLE
P1
P6
P2
BG
YR
P3
DS7220V2 Control Panel▶ Eight on-board zones
▶ Eight programmable Skeds
▶ RF compatibility
▶ Up to 32 users with optional keyfob operation available
▶ Four programmable authority levels
▶ Two communications routing destinations
▶ 254 event log
▶ Remote-programmable with RPS-INTL
▶ Optional Door Access Control Module (DACM)
▶ Network communication option (LAN/WAN)
www.boschsecurity.com
2 | DS7220V2 Control Panel
1. DS7445i LED Keypad
2. DS7445V2 LED Keypad
3. Door Access Control Module (DACM)
4. DS7447E LCD Keypad
5. DS7447V2 LCD Keypad
6. RF3227E RF Receiver
7. DS7220V2 Control Panel
8. DX3010 Octo-output Expander
9. DX2010 Input Expander
10. DX3020 X-10 Interface Module
11. DX4020 Network Interface Module
12. DX4010i RS-232 Serial Interface Module
13. DX4010i RS-232 Serial Interface Module
14. DS7447E LCD Keypad
15. DS7447V2 LCD Keypad
Functions
Alarm Verification OptionCentral station personnel can verify alarms with a two-wayvoice session with the premises, or visually through an on-premises camera connected to the optional rvm4c RemoteVideo Module.
Eight On-board ZonesThe DS7220V2 Control Panel has eight on-board zones. Itcan have hard-wired expanded zones and wireless zones.Program any of these zones to follow one of 15 zonefunctions.
The DS7220V2 Control Panel also allows configurationusing two resistors for each sensor loop. The control panelmonitors two zones for each sensor loop, making 16 on-board zones available. Zone doubling is also available onhard-wired expanded zones.
When programming zones for entry or exit delay times, youcan choose a longer delay time for zones located a longerdistance from the keypad.
Authority Levels and PINsThe system supports 32 Personal Identification Numbers(PIN). The PIN default is four digits, but can range betweenthree and seven digits. Designate an unlimited number ofmaster PINs. Use the master PINs to reprogram existingPINs. Program PINs using up to four different authoritylevels, which can restrict the PIN from bypassing, testing,and disarming the system.
Locally or Remotely ProgrammableThe system is completely keypad programmable (DS7447Eor DS7447V2 Keypad required). An Installer's Keypadfeature is also available that allows quick access to theprogramming menu.
Remote Programming Software (RPS) is a Windows®-basedaccount management and panel programming anddiagnostic utility. It is designed to remotely (or locally usingthe DX4010i Aux Data pins) set up and program theDS7220V2 Control Panels.
LED and LCD Keypad Support
Keypad Description
DS7445i LED KeypadDS7445V2 LED Keypad
Provide 16 operating LEDs, and eight systemstatus LEDs that indicate conditions such asarmed, fire alarm, and trouble.
Two-line displays allow custom zone and areadescriptions up to 16 characters. The enduser can adjust the sounder volume and back-light intensity using easy button commands.
LED and LCD keypads can be used in the same DS7220V2Control Panel system.
PK32The DS7220V2 Control Panel has an optional PK32Programming Key that can copy one control panel'sprogramming to another control panel. This can be used asan installer’s template. The installer could store aresidential template in one PK32 and a commercialtemplate in another PK32. The on-board LED illuminateswhen information is sent to or from the key, and blinkswhen functional diagnostics are performed on the key.
Flexible Digital CommunicationsThe DS7220V2 Control Panel works with most alarmreceivers that support Contact ID and SIA 300 digitalcommunicator formats and pager format. The pager formatallows control panels to dial a digital pager service andleave a numeric message representing the account number,event number, area number, and zone or user number.
Network Communication OptionAdding a DX4020 Network Interface Module provides bi-directional communications over an Ethernet network. Thenetwork can also be used for both remote programmingsessions with RPS and central station (ARC) reporting.
Event History LogA 254-event history log keeps a record of open and closeevents, alarms, and troubles organized by time and date.View the log information using the DS7447E and DS7447V2LCD Keypads or RPS. The log also tracks the area, zone(device), user, and communication information relevant toeach event. All 254 events are in non-volatile memory.
DS7220V2 Control Panel | 3
Scheduled Events (Skeds)Skeds are programmed events that occur at a specific timeof day and day of week. These events include Auto On, AutoPerimeter Only On, Auto Partial On, Auto Off and SkedOutput Function. Users can use the Extend Auto On Timefunction to add an additional hour to the setting for AutoOn, Auto Perimeter Only On and Auto Partial On. Dependingon the assigned authority level, users can change a sked.Eight skeds are available.
Fire Alarm VerificationThe DS7220V2 Control Panel can automatically reset smokedetectors after an initial alarm. If a second alarm occurswithin the verification window, an immediate fire alarmresults. This reduces potential false alarms, while stillproviding fast response to an alarm.
Door Access Control Modules (DACMs)A DACM grants or restricts access through a door using akeypad, credential reader, Request-to-Exit (REX) input, or adoor contact. Each DACM replaces one system keypad andsupervises one door. The DACM can also function as astand-alone device.
ZonesThe DS7220V2 Control Panel accepts up to 24 zones in anycombination of the available on-board zones, hard-wiredexpanded zones, or wireless zones.
AreasThe DS7220V2 Control Panel can be divided into twoindependently-configurable areas. Each area can haveseparate keypads and a separate reporting ID.
OutputsThe DS7220V2 Control Panel has four on-boardprogrammable outputs that can be expanded up to 12.
PO 1: terminals can be configured as an alarm poweroutput. The default configuration for PO 1 makes it a drycontact, Normally-Open (NO) relay.
PO 2: can be used with Alarm + as a supervised siren driver.Connect an approved 4 Ω or 8 Ω speaker. Alternatively, PO 2can sink up to 500 mA, 12 VDC.
PO 3 and PO 4: can be configured for Alarm Output. Theseoutputs can sink 500 mA, 12 VDC each.
Certifications and Approvals
Region Certification
Europe CE 1999/5/EC, 2006/95/EC, 2004/108/EC; EN 55022:2006 + A1:2007, Class B;EN 50130-4 w/A1:1998 + A2:2003;EN61000-3-2:2006;EN61000-3-3:1995; EN 60950-1:2001;TBR21:1998
Russia GOST GOST 12997-84, GOST R MEK60065-2002, GOST R 50009-2000,GOST R 51317.3.2-99, GOST R51317.3.3-99
France AFNOR NF, A2P (122077-00)
China CCC DS7220V2-CHI: 2005031902000137
Sweden INTYG 05-303
Brazil ANATEL 1240-05-1855
The DS7220V2 Control Panel is designed to comply with the following cer-tifications, approvals, and standards.
EN50131-1 grade 2
Installation/Configuration Notes
Compatibility Information
Batteries D126 12 V, 7 Ah Standby Battery
D1218 12 V, 18 Ah Standby Battery
D1240 12 V, 4 Ah Standby Battery
Keypads DS7445i LED Keypad
DS7445V2 LED Keypad
DS7446KP LCD Keypad
DS7447E LCD Keypad
DS7447V2 LCD Keypad
Fire Detectors D132A Smoke Detector Reversing Relay