This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
*TSO:Temperature sensitivity of offset voltage *TCS:Temperature coefficient of output span voltage *Temperature range from 0-50 deg C
RoHS compliance
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-012-EH-0110.pdf
Sensing element/Gauge FPN Data sheet
2
■Outline dimensions■
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-012-EH-0110.pdf
Sensing element/Gauge FPN Data sheet
3
■Connection diagram■
■Output characteristics■
Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected]
Output span voltage
Rated pressure
↑Output voltage(mV)
→Pressure(kPa)
0kPa
Offset voltage
-Rated pressure
Atomospheric pressure
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-015-EH-0110.pdf
Sensing element/Gauge FGN Data sheet
1
■Features ■Applications Surface mount package ・Home use Non-Invasive Blood Pressure (NIBP) monitors ・Vacuum cleaner ・Washing machine ■Part number for ordering
Length of the pressure port Rated Pressure (PSI) G:Gauge Pressure
Terminal leads configuration Surface mount package
FGN-6 07P G SR
6:6mm Pressure type
RoHS compliance
*TSO:Temperature sensitivity of offset voltage *TCS:Temperature coefficient of output span voltage *Temperature range from 0-50 deg C
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-015-EH-0110.pdf
Sensing element/Gauge FGN Data sheet
2
■Outline dimensions■
■Connection diagram■
2-φ1.1
FGN
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-015-EH-0110.pdf
Sensing element/Gauge FGN Data sheet
3
■Output characteristics■
Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected]
*TSO:Temperature sensitivity of offset voltage *TCS:Temperature coefficient of output span voltage *Temperature range from 0-50 deg C
RoHS compliance
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-017-EH-0110.pdf
Sensing element/Gauge FPM Data sheet
2
■Outline dimensions■
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-017-EH-0110.pdf
Sensing element/Gauge FPM Data sheet
3
■Connection diagram■
■Output characteristics■
Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected]
Recommended operating conditions Pressure type Absolute pressure -
Rated pressure 168.0 kPa・abs Measurable pressure range 34.66~168.0 kPa・abs
Temperature range 0~50 ℃ Pressure media Non-corrosive gases only (No liquid) -
Excitation current (Constant) 1.5 mADC Absolute maximum rating
Maximum load pressure Twice of rated pressure - Maximum excitation current 3.0 mADC
Operating temperature -20~100 ℃ Storage temperature -40~120 ℃ Operating humidity 30~80 (Non dew condition) %RH
Electric characteristics (Drive Current 1.5mA constant ,ambient temperature Ta=25℃) Output span voltage 80~160 (at 34.66~168.0kPa・abs) mV
Offset voltage 50~130 (at 101.3 kPa・abs) mV Bridge resistance 4000~6000 Ω Response time 2 (for the reference) msec
Accuracy TSO* ±3 %FS/0~50℃
TCS* 2.5 %FS/0~50℃
Linearity ±0.3 %FS Pressure hysteresis ±0.2 %FS
Model
Rated Pressure (PSI)
Pressure type A:Absolute pressure
Terminal leadsdirection
No Mark:
R :
FPM-15P A R
*TSO:Temperature sensitivity of offset voltage *TCS:Temperature coefficient of output span voltage *Temperature range from 0-50 deg C
RoHS compliance
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-010-EH-0110.pdf
Sensing element/Absolute FPM-A Data sheet
2
■Outline dimensions■
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-010-EH-0110.pdf
Sensing element/Absolute FPM-A Data sheet
3
■Connection diagram■
■Output characteristics■
Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected]
Output span voltage
168.0
↑Output voltage(mV)
→Pressure(kPa・abs) 34.66
Offset voltage
101.3
Atomospheric pressure
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-009-EH-0110.pdf
Sensing element/Gauge FGM Data sheet
1
■Features ■Applications Surface mount package ・Industrial instrumentation
Length of the pressure port Rated Pressure (PSI) G:Gauge Pressure
Terminal leads configuration Surface mount package
FGM-6 07P G SR
3:3mm Pressure type
6:6mm
RoHS compliance
*TSO:Temperature sensitivity of offset voltage *TCS:Temperature coefficient of output span voltage *Temperature range from 0-50 deg C
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-009-EH-0110.pdf
Sensing element/Gauge FGM Data sheet
2
■Outline dimensions■
2-φ1.1
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-009-EH-0110.pdf
Sensing element/Gauge FGM Data sheet
3
■Connection diagram■
■Output characteristics■
Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected]
<602PG~607PG>
<302PG~307PG>
Output span voltage
Rated pressure
↑Output voltage(mV)
→Pressure(kPa)
0kPa
Offset voltage
-Rated pressure
Atomospheric pressure
<315PG~3120PG> <615PG~6120PG>
Output span voltage
Rated pressure
↑Output voltage(mV)
→Pressure(kPa)
0kPa
Offset voltage
-98.07kPa
Atomospheric pressure
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-007-EH-0110.pdf
Sensing element/Differential FDM Data sheet
1
■Features ■Applications Differential pressure,Surface mount package ・Industrial instrumentation
Terminal leads configuration Surface mount package
Model
Rated Pressure (PSI)
Pressure type D:Differential pressure
FDM-07P D SR
*TSO:Temperature sensitivity of offset voltage *TCS:Temperature coefficient of output span voltage *Temperature range from 0-50 deg C **1 Port1 pressure >Port2 pressure , Port2 pressure:reference pressure **2 Output refers to pressure at pressure port2.
RoHS compliance
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-007-EH-0110.pdf
Sensing element/Differential FDM Data sheet
2
■Outline dimensions■
■Connection diagram■
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-007-EH-0110.pdf
Sensing element/Differential FDM Data sheet
3
■Output characteristics■
Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected]
Output span voltage
Rated pressure
↑Output voltage(mV)
→Pressure(kPa)
0kPa
Offset voltage
-Rated pressure
Atomospheric pressure
Pressure(kPa) =Port1 pressure - Port2 pressure (Port1 pressure >Port2 pressure) Output refers to pressure at pressure port2.
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-016-EH-0110.pdf
Sensing element/Gauge FHM Data sheet
1
■Features ■Applications Horizonral pressure port ・Industrial instrumentation
*TSO:Temperature sensitivity of offset voltage *TCS:Temperature coefficient of output span voltage *Temperature range from 0-50 deg C
RoHS compliance
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-016-EH-0110.pdf
Sensing element/Gauge FHM Data sheet
2
■Outline dimensions■
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-016-EH-0110.pdf
Sensing element/Gauge FHM Data sheet
3
■Connection diagram■
■Output characteristics■
Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected]
Measurable pressure range(kPa・abs) Part number for ordering
34.66~168.0 FAM-15PASR
■Specifications Model FAM-15PASR Unit
Recommended operating conditions Pressure type Absolute pressure -
Rated pressure 168.0 kPa・abs Measurable pressure range 34.66~168.0 kPa・abs
Temperature range 0~50 ℃ Pressure media Non-corrosive gases only (No liquid) -
Excitation current (Constant) 1.5 mADC Absolute maximum rating
Maximum load pressure Twice of rated pressure - Maximum excitation current 3.0 mADC
Operating temperature -20~100 ℃ Storage temperature -40~120 ℃ Operating humidity 30~80 (Non dew condition) %RH
Electric characteristics (Drive Current 1.5mA constant ,ambient temperature Ta=25℃) Output span voltage 80~160 (at 34.66~168.0kPa・abs) mV
Offset voltage 50~130 (at 101.3 kPa・abs) mV Bridge resistance 4000~6000 Ω Response time 2 (for the reference) msec
Accuracy TSO* ±3 %FS/0~50℃
TCS* 2.5 %FS/0~50℃
Linearity ±0.3 %FS Pressure hysteresis ±0.2 %FS
Terminal leads configuration Surface mount package
Model
Rated Pressure (PSI)
Pressure type A:Absolute pressure
FAM-15P A SR
RoHS compliance
*TSO:Temperature sensitivity of offset voltage *TCS:Temperature coefficient of output span voltage *Temperature range from 0-50 deg C
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-011-EH-0110.pdf
Sensing element/Absolute FAM Data sheet
2
■Outline dimensions■
■Connection diagram■
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-32-102-011-EH-0110.pdf
Sensing element/Absolute FAM Data sheet
3
■Output characteristics■
Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected]
Output span voltage
168.0
↑Output voltage(mV)
→Pressure(kPa・abs) 34.66
Offset voltage
101.3
Atomospheric pressure
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-31-102-001-EH-0110.pdf
Pre-amplified/5V Excitation/Gauge XFPN Data sheet
1
■Features ■Applications On-chip amplification and temperature compensations ・Home use Non-Invasive Blood Pressure (NIBP) monitors Pre-calibration of offset voltage and span ・Vacuum cleaner Dual-in-line package (DIP) ・Washing machine ■Part number for ordering
Temperature range 0~50 ℃ Pressure media Non-corrosive gases only (No liquid) -
Supply voltage(constant) 5±0.25 VDC Absolute maximum rating
Maximum load pressure Twice of rated pressure - Maximum excitation voltage 8 VDC
Operating temperature -10~80 ℃ Storage temperature -20~100 ℃ Operating humidity 30~80 (Non dew condition) %RH
Electrical characteristics (Excitation voltage Vcc=5.0V constant ,ambient temperature Ta=25℃) Power consumption 10mA max. mA Output impedance 10Ω max. Ω
Source current 0.2mA max. mA Sink current 2mA max. mA
Response time 2 (for the reference) msec Output span voltage 4.0 V
Offset voltage * 0.5±0.1 (at 0 kPa ) V Output voltage at full scale * 4.5±0.1 (at rated pressure) V
Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected]
↑Output voltage(mV)
Rated pressure
→Pressure(kPa)
0kPa
Offset voltage
4.5V
0.5V
Output voltage at full scale
Output span voltage
Atomospheric pressure
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-31-102-019-EH-0110.pdf
Pre-amplified/5V Excitation/Gauge XFGN Data sheet
1
■Features ■Applications On-chip amplification and temperature compensations ・Home use Non-Invasive Blood Pressure (NIBP) monitors Pre-calibration of offset voltage and span ・Vacuum cleaner Surface mount package ・Washing machine ■Part number for ordering
Temperature range 0~50 ℃ Pressure media Non-corrosive gases only (No liquid) -
Supply voltage(constant) 5±0.25 VDC Absolute maximum rating
Maximum load pressure Twice of rated pressure - Maximum excitation voltage 8 VDC
Operating temperature -10~80 ℃ Storage temperature -20~100 ℃ Operating humidity 30~80 (Non dew condition) %RH
Electrical characteristics (Excitation voltage Vcc=5.0V constant ,ambient temperature Ta=25℃) Power consumption 10mA max. mA Output impedance 10Ω max. Ω
Source current 0.2mA max. mA Sink current 2mA max. mA
Response time 2 (for the reference) msec Output span voltage 4.0 V
Offset voltage * 0.5±0.1 (at 0 kPa ) V Output voltage at full scale * 4.5±0.1 (at rated pressure) V
Accuracy * ±5.0 %FS/0~50℃
RoHS compliance
XFGN-6 025KP G SR
Model
Length of the pressure port Rated Pressure (kPa)
Terminal leads configuration Surface mount package
Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected]
↑Output voltage(mV)
Rated pressure
→Pressure(kPa)
0kPa
Offset voltage
4.5V
0.5V
Output voltage at full scale
Output span voltage
Atomospheric pressure
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-31-102-002-EH-0110.pdf
Pre-amplified/5V Excitation/Gauge XFPM Data sheet
1
■Features ■Applications On-chip amplification and temperature compensations ・Industrial instrumentation Pre-calibration of offset voltage and span ・Pressure switch, Pneumatic device Dual-in-line package (DIP) ・Medical device ■Part number for ordering
Temperature range 0~85 ℃ Pressure media Non-corrosive gases only (No liquid) -
Supply voltage(constant) 5±0.25 VDC Absolute maximum rating
Maximum load pressure
Twice of rated pressure
1.5 times of rating pressure
-
Maximum excitation voltage 8 VDC Operating temperature -40~125 ℃ Storage temperature -40~125 ℃ Operating humidity 30~80 (Non dew condition) %RH
Electrical characteristics (Excitation voltage Vcc=5.0V constant ,ambient temperature Ta=25℃) Power consumption 10mA max. mA Output impedance 10Ω max. Ω
Source current 0.2mA max. mA Sink current 2mA max. mA
Response time 2 (for the reference) msec Output span voltage 4.5 V
Offset voltage *1 *2 *3 0.2±0.1125 (at 0 kPa ) V Output voltage at full scale *1 *4 *5 4.7±0.1125 (at rated pressure) V
Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected]
↑Output voltage(mV)
Rated pressure
→Pressure(kPa)
0kPa
Offset voltage
4.7V
0.2V
Output voltage at full scale
Output span voltage
Atomospheric pressure
↑Output voltage(mV)
→Pressure(kPa)
Offset voltage
4.7V
0.2V
Output voltage at full scale
Output span voltage
Atomospheric pressure
+100kPa -100kPa 0kPa
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-31-102-005-EH-0110.pdf
Pre-amplified/5V Excitation/Absolute XFPM-A Data sheet
1
■Features ■Applications Barometric pressure measurable ・Industrial instrumentation On-chip amplification and temperature compensations ・Medical device Pre-calibration of offset voltage and span ・Barometer, Altimeter Dual-in-line package (DIP) ・Altitude compensation ■Part number for ordering
Weight (grams)
1.5
Measurable pressure range(kPa・abs) Part number for ordering
15~115 XFPM-115KPA XFPM-115KPAR
■Specifications Model XFPM-115KPA / XFPM-115KPAR Unit
Recommended operating conditions Pressure type Absolute pressure -
Rated pressure 115 kPa・abs Measurable pressure range 15~115 kPa・abs
Temperature range 0~85 ℃ Pressure media Non-corrosive gases only (No liquid) -
Supply voltage(constant) 5±0.25 VDC Absolute maximum rating
Maximum load pressure Twice of rated pressure - Maximum excitation voltage 8 VDC
Operating temperature -40~125 ℃ Storage temperature -40~125 ℃ Operating humidity 30~80 (Non dew condition) %RH
Electrical characteristics (Excitation voltage Vcc=5.0V constant ,ambient temperature Ta=25℃) Power consumption 10mA max. mA Output impedance 10Ω max. Ω
Source current 0.2mA max. mA Sink current 2mA max. mA
Response time 2 (for the reference) msec Output span voltage 4.5 V
Offset voltage * 0.2±0.1125 (at 15 kPa・abs ) V Output voltage at full scale * 4.7±0.1125 (at 115kPa・abs ) V
Accuracy * ±2.5 %FS/0~85℃
* Excluding input voltage error.
XFPM-115KP A R
Model
Rated Pressure (kPa)
Pressure type A:Absolute pressure
Terminal leadsdirection
No Mark:
R :
RoHS compliance
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-31-102-005-EH-0110.pdf
Pre-amplified/5V Excitation/Absolute XFPM-A Data sheet
2
■Outline dimensions■
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-31-102-005-EH-0110.pdf
Pre-amplified/5V Excitation/Absolute XFPM-A Data sheet
Pre-amplified/5V Excitation/Absolute XFPM-A Data sheet
4
■Output characteristics■
Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected]
Output voltage at full scale
Output span voltage
115kPa・abs
→Pressure(kPa・abs) 15kPa・abs
Offset voltage
4.7V
0.2V
↑Output voltage(mV)
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-31-102-031-EH-0413.pdf
DATE 29 March, 2013
No. V-70001
Messrs.
SPECIFICATION
Model:
AP2, AG2 Pressure Sensor
Project:
Distributor:
Reference:
Yoshiyuki Uchiumi, Application Engineer
Sensor Department Fujikura Ltd.
Preliminary Edition
Ver. 2.00
This document has a possibility to
be revised without notice.
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-31-102-031-EH-0413.pdf
V-70001
1 of 12
Preliminary Edition Ver. 2.00 This document has a possibility to be revised without notice.
1. General
This document describes the specifications of Fujikura Pressure Sensors, AP2 and AG2 series.
2. Principle
Fujikura Pressure Sensor is composed of a silicon piezoresistive pressure sensing chip and a signal
conditioning integrated circuit. The low-level signal from the sensing chip is amplified, temperature
compensated, calibrated, and finally converted to a high-level output signal that is proportional to the applied
pressure.
3. Device Lineup
This device has the following lineup.
Model Pressure
Type
Supply
Voltage Accuracy
Pressure Range (kPa)
-100 0 25 50 100 200 1000
AP2
or
AG2
Gauge
5.0Vdc
or
3.3Vdc
±1.5%FS
3.0Vdc ±2.0%FS Same as the above
4. RoHS
This device is compliant with the Restriction of the use of certain Hazardous Substances in Electrical and
Electronic Equipment (RoHS).
Table shown below is revision records of this specification
Rev.
Est.
Date Name Comment Mark
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-31-102-031-EH-0413.pdf
V-70001
2 of 12
Preliminary Edition Ver. 2.00 This document has a possibility to be revised without notice.
5. Block Diagram and Pin Connections
Pin No. Pin Name I/O Type Function
1 VSS - - Common voltage connection
2 VOUT O Analog Analog output
3 VDD - - Power supply connection *1
4 NC - - - *2
5 NC - - - *2
6 NC - - - *2
Notes:
*1) 0.1µF capacitance is recommended to connect VDD Pin 3 with VSS Pin 1.
*2) Pin 4, 5 and 6 must be open.
Temperature Sensor
EEPROM
Pin 2 VOUT
Pin 3 VDD
Sensor Bridge
Buffer
3.0V, 3.3 or 5Vdc
Pin 1 VSS
Pin 4 NC
0.1µF
Power On Reset
Oscillator
ADC DAC MUX DSP
Pre-amplifier
Pin 5 NC
Pin 6 NC
VDD
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-31-102-031-EH-0413.pdf
V-70001
3 of 12
Preliminary Edition Ver. 2.00 This document has a possibility to be revised without notice.
6. Device Name Code
The device name code is consisted of Sensor code, Pressure code and Packing style. For the exact ordering
device number, please refer to Section 16 Ordering Information.
7. Absolute Maximum Ratings *1
Item Symbol Rating Unit
Maximum Load Pressure
Pre
ssu
re C
od
e
025KG
Pmax+
+50 kPa
050KG +100 kPa
100KG +200 kPa
200KG +400 kPa
001MG +1.5 MPa
100KV -200 kPa
100KW ±200 kPa
Maximum Input Voltage VDD 6 Vdc
Operating Temperature Topt -40 ~ +125 deg. C
Storage Temperature Tstg -40 ~ +125 deg. C
Note: *1) Absolute maximum ratings are the limits that the device will withstand without damage.
Pin direction for AP2 N : Normal
R : Opposite
Port length for AG2 3 : 3mm
6 : 6mm
AP2 0 N - 025 K G
Model AP2 : DIP (Dual Inline Package) AG2 : SMD (Surface Mount Device)
Preliminary Edition rev. 1.00 This document has a possibility to be revised without notice.
Table of Contents
1. General .......................................................................................................................................... 2
■Features ■Applications On-chip amplification and temperature compensations ・Industrial instrumentation Pre-calibration of offset voltage and span ・Pressure switch, Pneumatic device Surface mount package ・Medical device ■Part number for ordering
Weight(grams)
Weight (grams)
0.3
0.35
Part number for ordering Measurable pressure
range(kPa) 3mm pressure port 6mm pressure port -100~100 XFGM-3100KPGWSR XFGM-6100KPGWSR
Temperature range 0~85 ℃ Pressure media Non-corrosive gases only (No liquid) -
Supply voltage(constant) 5±0.25 VDC Absolute maximum rating
Maximum load pressure
Twice of rated pressure
1.5 times of rating pressure
-
Maximum excitation voltage 8 VDC Operating temperature -40~125 ℃ Storage temperature -40~125 ℃ Operating humidity 30~80 (Non dew condition) %RH
Electrical characteristics (Excitation voltage Vcc=5.0V constant ,ambient temperature Ta=25℃) Power consumption 10mA max. mA Output impedance 10Ω max. Ω
Source current 0.2mA max. mA Sink current 2mA max. mA
Response time 2 (for the reference) msec Output span voltage 4.5 V
Offset voltage *1 *2 *3 0.2±0.1125 (at 0 kPa ) V Output voltage at full scale *1 *4 *5 4.7±0.1125 (at rated pressure) V
Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected]
↑Output voltage(mV)
→Pressure(kPa)
Offset voltage
4.7V
0.2V
Output voltage at full scale
Output span voltage
Atomospheric pressure
+100kPa -100kPa 0kPa
↑Output voltage(mV)
Rated pressure
→Pressure(kPa)
0kPa
Offset voltage
4.7V
0.2V
Output voltage at full scale
Output span voltage
Atomospheric pressure
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-31-102-004-EH-0110.pdf
Pre-amplified/5V Excitation/Differential XFDM Data sheet
1
■Features ■Applications Dif ferential pressure ・Industrial instrumentation On-chip amplification and temperature compensations ・Pressure switch, Pneumatic device Pre-calibration of offset voltage and span ・Medical device Surface mount package ■Part number for ordering
Temperature range 0~85 ℃ Pressure media Non-corrosive gases only (No liquid) -
Supply voltage(constant) 5±0.25 VDC Absolute maximum rating Maximum differential pressure *1 Port1 Maximum load pressure Port2 Maximum load pressure
Twice of rated pressure
1.5 times of rating
pressure -
Maximum excitation voltage 8 VDC Operating temperature -40~125 ℃ Storage temperature -40~125 ℃ Operating humidity 30~80 (Non dew condition) %RH
Electrical characteristics (Excitation voltage Vcc=5.0V constant ,ambient temperature Ta=25℃) Power consumption 10mA max. mA Output impedance 10Ω max. Ω
Source current 0.2mA max. mA Sink current 2mA max. mA
Response time 2 (for the reference) msec Output span voltage 4.5 V Offset voltage *2,*3 *4 0.2±0.1125 (at 0 kPa ) V
Output voltage at full scale *2,*3 *5 4.7±0.1125 (at rated pressure) V Accuracy *2,*3 ±2.5 %FS/0~85℃
Terminal leads configuration Surface mount package
Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected]
↑Output voltage(mV)
Rated pressure
→Pressure(kPa) 0kPa
Offset voltage
4.7V
0.2V
Output voltage at full scale
Output span voltage
Atomospheric pressure
Pressure(kPa) =Port1 pressure - Port2 pressure (Port1 pressure >Port2 pressure) Output refers to pressure at pressure port2.
↑Output voltage(mV)
→Pressure(kPa)
Offset voltage
4.7V
0.2V
Output voltage at full scale
Output span voltage
Atomospheric pressure
+100kPa-100kPa 0kPa
Pressure(kPa) =Port1 pressure - Port2 pressure (Port1 pressure >Port2 pressure) Output refers to pressure at pressure port2.
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-31-102-003-EH-0110.pdf
Pre-amplified/5V Excitation/Gauge XFHM Data sheet
1
■Features ■Applications On-chip amplification and temperature compensations ・Industrial instrumentation Pre-calibration of offset voltage and span ・Pressure switch, Pneumatic device Horizonral pressure port ・Medical device ■Part number for ordering
Temperature range 0~85 ℃ Pressure media Non-corrosive gases only (No liquid) -
Supply voltage(constant) 5±0.25 VDC Absolute maximum rating
Maximum load pressure
Twice of rated pressure
1.5 times of rating pressure
-
Maximum excitation voltage 8 VDC Operating temperature -40~125 ℃ Storage temperature -40~125 ℃ Operating humidity 30~80 (Non dew condition) %RH
Electrical characteristics (Excitation voltage Vcc=5.0V constant ,ambient temperature Ta=25℃) Power consumption 10mA max. mA Output impedance 10Ω max. Ω
Source current 0.2mA max. mA Sink current 2mA max. mA
Response time 2 (for the reference) msec Output span voltage 4.5 V
Offset voltage * *2 *3 0.2±0.1125 (at 0 kPa ) V Output voltage at full scale * *4 *5 4.7±0.1125 (at rated pressure) V
Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected]
↑Output voltage(mV)
→Pressure(kPa)
Offset voltage
4.7V
0.2V
Output voltage at full scale
Output span voltage
Atomospheric pressure
+100kPa-100kPa 0kPa
↑Output voltage(mV)
Rated pressure
→Pressure(kPa) 0kPa
Offset voltage
4.7V
0.2V
Output voltage at full scale
Output span voltage
Atomospheric pressure
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-31-102-006-EH-0110.pdf
Pre-amplified/5V Excitation/Absolute XFAM Data sheet
1
■Features ■Applications Barometric pressure measurable ・Industrial instrumentation On-chip amplification and temperature compensations ・Medical device Pre-calibration of offset voltage and span ・Barometer, Altimeter Surface mount package ・Altitude compensation ■Part number for ordering
Weight (grams)
0.3
Measurable pressure range(kPa・abs) Part number for ordering
15~115 XFAM-115KPASR
■Specifications Model XFAM-115KPASR Unit
Recommended operating conditions Pressure type Absolute pressure -
Rated pressure 115 kPa・abs Measurable pressure range 15~115 kPa・abs
Temperature range 0~85 ℃ Pressure media Non-corrosive gases only (No liquid) -
Supply voltage(constant) 5±0.25 VDC Absolute maximum rating
Maximum load pressure Twice of rated pressure - Maximum excitation voltage 8 VDC
Operating temperature -40~125 ℃ Storage temperature -40~125 ℃ Operating humidity 30~80 (Non dew condition) %RH
Electrical characteristics (Excitation voltage Vcc=5.0V constant ,ambient temperature Ta=25℃) Power consumption 10mA max. mA Output impedance 10Ω max. Ω
Source current 0.2mA max. mA Sink current 2mA max. mA
Response time 2 (for the reference) msec Output span voltage 4.5 V
Offset voltage * 0.2±0.1125 (at 15 kPa・abs ) V Output voltage at full scale * 4.7±0.1125 (at 115kPa・abs ) V
Accuracy * ±2.5 %FS/0~85℃
XFAM-115KP A SR
Terminal leads configuration Surface mount package
Model
Rated Pressure (kPa)
Pressure type A:Absolute pressure
* Excluding input voltage error.
RoHS compliance
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-31-102-006-EH-0110.pdf
Pre-amplified/5V Excitation/Absolute XFAM Data sheet
2
■Outline dimensions■
■Connection diagram■
View from Lavel
Marking
XFAM
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
100-31-102-006-EH-0110.pdf
Pre-amplified/5V Excitation/Absolute XFAM Data sheet
Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : [email protected]
Output voltage at full scale
Output span voltage
115kPa・abs
→Pressure(kPa・abs) 15kPa・abs
Offset voltage
4.7V
0.2V
↑Output voltage(mV)
100-31-102-005-DH-0713
100-31-102-005-DH-0713.pdf
Wir sind für Sie da. Adressen und Kontakte
Verkauf Österreich
Kurt StritzelbergerNeumarkter Str. 86aD-81673 München