Top Banner
©PGH Bricks and Pavers Pty Ltd 2017. This document should not be reproduced or communicated without the prior written approval of PGH Bricks & Pavers Pty Ltd Do not scale this drawing DRAWING NUMBER DRAWING TITLE DRAWN BY BY DATE DESCRIPTION REV REVISION SHEET NO PAPER SIZE SCALE A: 75 Townson Road, Schofields, NSW 2762 E: [email protected]u T: 61 2 9235 8000 F: 61 2 8362 9005 ABN 68 168 794 821 A INFORMATION N/A A3 01 A P.A 11/04/2019 COVER PAGE AVA-TYP-COV 11/04/2019 P.A AVANTE TYPICAL DETAIL LIST NO. TITLE DETAIL DRAWING NUMBER REV. SHEET NO. 1 COVER PAGE COV AVA-TYP-COV A 1 2 TYPICAL ELEVATION ELEV AVA-TYP-ELEV A 2 3 FIXING PATTERN D01 AVA-TYP-D01 A 3 4 TYPICAL AVANTE WALL SECTION (SIDE VIEW) D02 AVA-TYP-D02 A 4 5 TYPICAL AVANTE WALL SECTION (TOP VIEW) D03 AVA-TYP-D03 A 5 6 FLOOR FLASHING DETAIL D04 AVA-TYP-D04 A 6 7 TYPICAL CAPPING DETAIL D05 AVA-TYP-D05 A 7 8 HORIZONTAL EXPANSION JOINT AND SLAB EDGE FLASHING D06 AVA-TYP-D06 A 8 9 VERTICAL EXPANSION JOINTDETAIL D07 AVA-TYP-D07 A 9 10 WINDOW JAMB DETAIL D08 AVA-TYP-D08 A 10 11 DOOR JAMB DETAIL D09 AVA-TYP-D09 A 11 12 WINDOW HEAD DETAIL DETAIL D10 AVA-TYP-D10 A 12 14 WINDOW SILL DETAIL D11 AVA-TYP-D11 A 13 15 CORNER DETAILS D12 AVA-TYP-D12 A 14 16 TYPICAL AVANTE DETAIL ABUTTING TO SOFFIT LINE D13 AVA-TYP-D13 A 15 17 TYPICAL AVANTE DETAIL ABUTTING INTO TRADITIONAL BRICK D14 AVA-TYP-D14 A 16 *NOTES: 1. SEE CONSTRUCTION MANUAL FOR MATERIAL SELECTION FOR CORROSIVITY ENVIRONMENT. 2. SEE CONSTRUCTION MANUAL (CANTILEVER SPAN TABLE) FOR MORE INFORMATION ABOUT AVANTE RAIL CANTILEVER SPAN REQUIREMENTS.
16

DRAWING SHEET NUMBER REV. CORROSIVITY ENVIRONMENT. …€¦ · 8 horizontal expansion joint and slab edge flashing d06 ava-typ-d06 a 8 9 vertical expansion jointdetail d07 ava-typ-d07

Jun 13, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: DRAWING SHEET NUMBER REV. CORROSIVITY ENVIRONMENT. …€¦ · 8 horizontal expansion joint and slab edge flashing d06 ava-typ-d06 a 8 9 vertical expansion jointdetail d07 ava-typ-d07

©PGH Bricks and Pavers Pty Ltd 2017. This document should not be reproduced or communicated

without the prior written approval of PGH Bricks & Pavers Pty Ltd

Do not scale this drawing

DRAWING NUMBER

DRAWING TITLEDRAWN BYBY DATEDESCRIPTIONREV

REVISION

SHEET NO

PAPER SIZE

SCALE

A: 75 Townson Road, Schofields, NSW 2762

E: [email protected]

T: 61 2 9235 8000

F: 61 2 8362 9005

ABN 68 168 794 821

AINFORMATION

N/A

A3

01

A

P.A

11/04/2019

COVER PAGE

AVA-TYP-COV

11/04/2019P.A

AVANTE TYPICAL DETAIL LIST

NO. TITLE DETAIL

DRAWING

NUMBER

REV.

SHEET

NO.

1 COVER PAGE COV AVA-TYP-COV A 1

2 TYPICAL ELEVATION ELEV AVA-TYP-ELEV A 2

3 FIXING PATTERN D01 AVA-TYP-D01 A 3

4

TYPICAL AVANTE WALL SECTION (SIDE VIEW)

D02 AVA-TYP-D02 A 4

5

TYPICAL AVANTE WALL SECTION (TOP VIEW)

D03 AVA-TYP-D03 A 5

6 FLOOR FLASHING DETAIL D04 AVA-TYP-D04 A 6

7 TYPICAL CAPPING DETAIL D05 AVA-TYP-D05 A 7

8 HORIZONTAL EXPANSION JOINT AND SLAB EDGE FLASHING D06 AVA-TYP-D06 A 8

9 VERTICAL EXPANSION JOINTDETAIL D07 AVA-TYP-D07 A 9

10 WINDOW JAMB DETAIL D08 AVA-TYP-D08 A 10

11 DOOR JAMB DETAIL D09 AVA-TYP-D09 A 11

12 WINDOW HEAD DETAIL DETAIL D10 AVA-TYP-D10 A 12

14 WINDOW SILL DETAIL D11 AVA-TYP-D11 A 13

15 CORNER DETAILS D12 AVA-TYP-D12 A 14

16 TYPICAL AVANTE DETAIL ABUTTING TO SOFFIT LINE D13 AVA-TYP-D13 A 15

17 TYPICAL AVANTE DETAIL ABUTTING INTO TRADITIONAL BRICK D14 AVA-TYP-D14 A 16

*NOTES:

1. SEE CONSTRUCTION MANUAL

FOR MATERIAL SELECTION FOR

CORROSIVITY ENVIRONMENT.

2. SEE CONSTRUCTION MANUAL

(CANTILEVER SPAN TABLE) FOR

MORE INFORMATION ABOUT

AVANTE RAIL CANTILEVER SPAN

REQUIREMENTS.

Page 2: DRAWING SHEET NUMBER REV. CORROSIVITY ENVIRONMENT. …€¦ · 8 horizontal expansion joint and slab edge flashing d06 ava-typ-d06 a 8 9 vertical expansion jointdetail d07 ava-typ-d07

FLOOR LEVEL

GROUND LEVEL

PARAPET LEVEL

©PGH Bricks and Pavers Pty Ltd 2017. This document should not be reproduced or communicated

without the prior written approval of PGH Bricks & Pavers Pty Ltd

Do not scale this drawing

DRAWING NUMBER

DRAWING TITLEDRAWN BYBY DATEDESCRIPTIONREV

REVISION

SHEET NO

PAPER SIZE

SCALE

A: 75 Townson Road, Schofields, NSW 2762

E: [email protected]

T: 61 2 9235 8000

F: 61 2 8362 9005

ABN 68 168 794 821

AINFORMATION

N/A

A3

02

A

P.A

11/04/2019

TYPICAL ELEVATION

AVA-TYP-ELEV

11/04/2019P.A

PAGE 07

D05

PAGE 08

D06

PAGE 14

D12

PAGE 12

D10

PAGE 06

D04

PAGE 09

D07

D01

PAGE 03

PAGE 13

D11

PAGE 10

D08

PAGE 04

D02

PAGE 11

D09

PAGE 05

D03

6000mm MAX VERTICAL EXPANSION JOINT SPACING

3000mm MAX VERTICAL EXPANSION

JOINT FROM CORNER

HORIZONTAL EXPANSION JOINT @ FLOORS

Page 3: DRAWING SHEET NUMBER REV. CORROSIVITY ENVIRONMENT. …€¦ · 8 horizontal expansion joint and slab edge flashing d06 ava-typ-d06 a 8 9 vertical expansion jointdetail d07 ava-typ-d07

©PGH Bricks and Pavers Pty Ltd 2017. This document should not be reproduced or communicated

without the prior written approval of PGH Bricks & Pavers Pty Ltd

Do not scale this drawing

DRAWING NUMBER

DRAWING TITLEDRAWN BYBY DATEDESCRIPTIONREV

REVISION

SHEET NO

PAPER SIZE

SCALE

A: 75 Townson Road, Schofields, NSW 2762

E: [email protected]

T: 61 2 9235 8000

F: 61 2 8362 9005

ABN 68 168 794 821

AINFORMATION

N/A

A3

03

A

P.A

11/04/2019

FIXING PATTERN

AVA-TYP-D01

11/04/2019P.A

600 600 600 600

1200 MAX FIXING CENTRES

STAGGERED FIXING

#10 FASTENERS*

2400mm MAX AVANTE RAIL*S*

POSITION OF FIXINGS TO PERIMETER

TOP HATS*, Z-SECTIONS* OR HELPING

HANDS* @ 600 CTRS TO CREATE CAVITY

MIN 12mm EDGE DISTANCE (TYP)

Page 4: DRAWING SHEET NUMBER REV. CORROSIVITY ENVIRONMENT. …€¦ · 8 horizontal expansion joint and slab edge flashing d06 ava-typ-d06 a 8 9 vertical expansion jointdetail d07 ava-typ-d07

©PGH Bricks and Pavers Pty Ltd 2017. This document should not be reproduced or communicated

without the prior written approval of PGH Bricks & Pavers Pty Ltd

Do not scale this drawing

DRAWING NUMBER

DRAWING TITLEDRAWN BYBY DATEDESCRIPTIONREV

REVISION

SHEET NO

PAPER SIZE

SCALE

A: 75 Townson Road, Schofields, NSW 2762

E: [email protected]

T: 61 2 9235 8000

F: 61 2 8362 9005

ABN 68 168 794 821

AINFORMATION

N/A

A3

04

A

P.A

11/04/2019

TYPICAL AVANTE WALL SECTION (SIDE VIEW)

AVA-TYP-D02

11/04/2019P.A

230*76mm AVANTE BRICK FACINGS*

PRIMARY STRUCTURE

MIN 25mm CAVITY FORMED USING TOP HATS*,

Z-SECTIONS* OR HELPING HANDS* @ 600 CTRS

MAX 31mm OVERALL AVANTE SYSTEM (RAIL AND BRICK SLIP)

AVANTE RAIL*

10mm MORTAR* JOINT

#10 FASTENERS*

INTERNAL FINISHES

AIR/WATER/VAPOUR BARRIER IF REQUIRED FOR OVERALL

WALL NATIONAL CONSTRUCTION CODE (NCC) COMPLIANCE

Page 5: DRAWING SHEET NUMBER REV. CORROSIVITY ENVIRONMENT. …€¦ · 8 horizontal expansion joint and slab edge flashing d06 ava-typ-d06 a 8 9 vertical expansion jointdetail d07 ava-typ-d07

©PGH Bricks and Pavers Pty Ltd 2017. This document should not be reproduced or communicated

without the prior written approval of PGH Bricks & Pavers Pty Ltd

Do not scale this drawing

DRAWING NUMBER

DRAWING TITLEDRAWN BYBY DATEDESCRIPTIONREV

REVISION

SHEET NO

PAPER SIZE

SCALE

A: 75 Townson Road, Schofields, NSW 2762

E: [email protected]

T: 61 2 9235 8000

F: 61 2 8362 9005

ABN 68 168 794 821

AINFORMATION

N/A

A3

05

A

P.A

11/04/2019

TYPICAL AVANTE WALL SECTION (TOP VIEW)

AVA-TYP-D03

11/04/2019P.A

230*76mm AVANTE BRICK FACINGS*

AVANTE RAIL*

10mm MORTAR* JOINT

#10 FASTENERS*

AIR/WATER/VAPOUR BARRIER IF REQUIRED

FOR OVERALL WALL NATIONAL

CONSTRUCTION CODE (NCC) COMPLIANCE

MIN 25mm CAVITY FORMED USING TOP HATS*,

Z-SECTIONS* OR HELPING HANDS* @ 600 CTRS

INTERNAL FINISHES

PRIMARY STRUCTURE

MAX 31mm OVERALL AVANTE SYSTEM (RAIL AND BRICK SLIP)

Page 6: DRAWING SHEET NUMBER REV. CORROSIVITY ENVIRONMENT. …€¦ · 8 horizontal expansion joint and slab edge flashing d06 ava-typ-d06 a 8 9 vertical expansion jointdetail d07 ava-typ-d07

©PGH Bricks and Pavers Pty Ltd 2017. This document should not be reproduced or communicated

without the prior written approval of PGH Bricks & Pavers Pty Ltd

Do not scale this drawing

DRAWING NUMBER

DRAWING TITLEDRAWN BYBY DATEDESCRIPTIONREV

REVISION

SHEET NO

PAPER SIZE

SCALE

A: 75 Townson Road, Schofields, NSW 2762

E: [email protected]

T: 61 2 9235 8000

F: 61 2 8362 9005

ABN 68 168 794 821

AINFORMATION

N/A

A3

06

A

P.A

11/04/2019

FLOOR FLASHING DETAIL

AVA-TYP-D04

11/04/2019P.A

230*76mm AVANTE BRICK FACINGS*

AVANTE RAIL*

10mm MORTAR* JOINT

#10 FASTENERS*

AIR/WATER/VAPOUR BARRIER IF REQUIRED FOR OVERALL

WALL NATIONAL CONSTRUCTION CODE (NCC) COMPLIANCE

MIN 25mm CAVITY FORMED USING TOP HATS*,

Z-SECTIONS* OR HELPING HANDS* @ 600 CTRS

FLOOR

PRIMARY STRUCTURE

SEAL AND DRAIN AS REQUIRED FOR OVERALL WALL NCC COMPLIANCE. ALL

SEALANTS TO BE COMPATIBLE WITH AVANTE BRICK FACINGS AND MORTAR.

MAX 31mm OVERALL AVANTE SYSTEM (RAIL AND BRICK SLIP)

FLASHING IF REQUIRED FOR OVERALL WALL NCC COMPLIANCE

Page 7: DRAWING SHEET NUMBER REV. CORROSIVITY ENVIRONMENT. …€¦ · 8 horizontal expansion joint and slab edge flashing d06 ava-typ-d06 a 8 9 vertical expansion jointdetail d07 ava-typ-d07

©PGH Bricks and Pavers Pty Ltd 2017. This document should not be reproduced or communicated

without the prior written approval of PGH Bricks & Pavers Pty Ltd

Do not scale this drawing

DRAWING NUMBER

DRAWING TITLEDRAWN BYBY DATEDESCRIPTIONREV

REVISION

SHEET NO

PAPER SIZE

SCALE

A: 75 Townson Road, Schofields, NSW 2762

E: [email protected]

T: 61 2 9235 8000

F: 61 2 8362 9005

ABN 68 168 794 821

AINFORMATION

N/A

A3

07

A

P.A

11/04/2019

TYPICAL CAPPING DETAIL

AVA-TYP-D05

11/04/2019P.A

230*76mm AVANTE BRICK FACINGS*

AVANTE RAIL*

10mm MORTAR* JOINT

#10 FASTENERS*

AIR/WATER/VAPOUR BARRIER IF REQUIRED FOR OVERALL

WALL NATIONAL CONSTRUCTION CODE (NCC) COMPLIANCE

MIN 25mm CAVITY FORMED USING TOP HATS*,

Z-SECTIONS* OR HELPING HANDS* @ 600 CTRS

MAX 31mm OVERALL AVANTE SYSTEM (RAIL AND BRICK SLIP)

SEAL AS REQUIRED FOR OVERALL WALL NCC

COMPLIANCE. ALL SEALANTS TO BE COMPATIBLE

WITH AVANTE BRICK FACINGS AND MORTAR.

METAL CAPPING

PRIMARY STRUCTURE

Page 8: DRAWING SHEET NUMBER REV. CORROSIVITY ENVIRONMENT. …€¦ · 8 horizontal expansion joint and slab edge flashing d06 ava-typ-d06 a 8 9 vertical expansion jointdetail d07 ava-typ-d07

©PGH Bricks and Pavers Pty Ltd 2017. This document should not be reproduced or communicated

without the prior written approval of PGH Bricks & Pavers Pty Ltd

Do not scale this drawing

DRAWING NUMBER

DRAWING TITLEDRAWN BYBY DATEDESCRIPTIONREV

REVISION

SHEET NO

PAPER SIZE

SCALE

A: 75 Townson Road, Schofields, NSW 2762

E: [email protected]

T: 61 2 9235 8000

F: 61 2 8362 9005

ABN 68 168 794 821

AINFORMATION

N/A

A3

08

A

P.A

11/04/2019

HORIZONTAL CONTROL JOINT AND SLAB EDGE FLASHING DETAIL

AVA-TYP-D06

11/04/2019P.A

AIR/WATER/VAPOUR BARRIER IF REQUIRED FOR OVERALL WALL

NATIONAL CONSTRUCTION CODE (NCC) COMPLIANCE

MIN 25mm CAVITY FORMED USING TOP HATS*,

Z-SECTIONS* OR HELPING HANDS* @ 600 CTRS

PRIMARY STRUCTURE

#10 FASTENERS*

10mm MORTAR* JOINT

AVANTE RAIL*

MAX 31mm OVERALL AVANTE SYSTEM (RAIL AND BRICK SLIP)

SEAL AND DRAIN AS REQUIRED FOR

OVERALL WALL NCC COMPLIANCE. SEALANT

TO SUIT DESIGN BUILDING MOVEMENTS.

FLASHING AT SLAB EDGE IF REQUIRED

FOR OVERALL WALL NCC COMPLIANCE

CONCRETE SLAB / EDGE BEAM

MIN 15 mm

230*76mm AVANTE BRICK FACINGS*

Page 9: DRAWING SHEET NUMBER REV. CORROSIVITY ENVIRONMENT. …€¦ · 8 horizontal expansion joint and slab edge flashing d06 ava-typ-d06 a 8 9 vertical expansion jointdetail d07 ava-typ-d07

©PGH Bricks and Pavers Pty Ltd 2017. This document should not be reproduced or communicated

without the prior written approval of PGH Bricks & Pavers Pty Ltd

Do not scale this drawing

DRAWING NUMBER

DRAWING TITLEDRAWN BYBY DATEDESCRIPTIONREV

REVISION

SHEET NO

PAPER SIZE

SCALE

A: 75 Townson Road, Schofields, NSW 2762

E: [email protected]

T: 61 2 9235 8000

F: 61 2 8362 9005

ABN 68 168 794 821

AINFORMATION

N/A

A3

09

A

P.A

11/04/2019

VERTICAL EXPANSION JOINT DETAIL

AVA-TYP-07

11/04/2019P.A

AIR/WATER/VAPOUR BARRIER IF

REQUIRED FOR OVERALL WALL

NATIONAL CONSTRUCTION CODE

(NCC) COMPLIANCE

MIN 25mm CAVITY FORMED USING TOP HATS*,

Z-SECTIONS* OR HELPING HANDS* @ 600 CTRS

#10 FASTENERS*

10mm MORTAR* JOINT

AVANTE RAIL*

MAX 31mm OVERALL AVANTE SYSTEM (RAIL AND BRICK SLIP)

PRIMARY STRUCTURE

INTERNAL FINISHES

SEAL AND DRAIN AS REQUIRED FOR

OVERALL WALL NCC COMPLIANCE. SEALANT

TO SUIT DESIGN BUILDING MOVEMENTS.

MIN 15 mm

230*76mm AVANTE BRICK FACINGS*

AVANTE RAIL CANTILEVER SPAN*AVANTE RAIL CANTILEVER SPAN*

Page 10: DRAWING SHEET NUMBER REV. CORROSIVITY ENVIRONMENT. …€¦ · 8 horizontal expansion joint and slab edge flashing d06 ava-typ-d06 a 8 9 vertical expansion jointdetail d07 ava-typ-d07

©PGH Bricks and Pavers Pty Ltd 2017. This document should not be reproduced or communicated

without the prior written approval of PGH Bricks & Pavers Pty Ltd

Do not scale this drawing

DRAWING NUMBER

DRAWING TITLEDRAWN BYBY DATEDESCRIPTIONREV

REVISION

SHEET NO

PAPER SIZE

SCALE

A: 75 Townson Road, Schofields, NSW 2762

E: [email protected]

T: 61 2 9235 8000

F: 61 2 8362 9005

ABN 68 168 794 821

AINFORMATION

N/A

A3

10

A

P.A

11/04/2019

WINDOW JAMB DETAILS

AVA-TYP-D08

11/04/2019P.A

AIR/WATER/VAPOUR BARRIER IF REQUIRED FOR OVERALL

WALL NATIONAL CONSTRUCTION CODE (NCC) COMPLIANCE

MIN 25mm CAVITY FORMED USING TOP HATS*,

Z- SECTIONS* OR HELPING HANDS* @ 600 CTRS

PRIMARY STRUCTURE

PRIMARY STRUCTURE

SEAL AND DRAIN AS REQUIRED FOR OVERALL WALL NCC

COMPLIANCE. ALL SEALANTS TO BE COMPATIBLE WITH AVANTE

BRICK FACINGS AND MORTAR

230*110*76mm AVANTE PISTOL CORNER

10mm MORTAR* JOINT

AVANTE RAIL*

#10 FASTENERS*

WINDOW JAMB

SCALE N/A

WINDOW JAMB DETAIL - BRICK REVEAL

01

SCALE N/A

WINDOW JAMB DETAIL - METAL REVEAL

02

MAX 31mm OVERALL AVANTE SYSTEM (RAIL AND BRICK SLIP)

AVANTE RAIL*

AIR/WATER/VAPOUR BARRIER IF REQUIRED FOR OVERALL

WALL NATIONAL CONSTRUCTION CODE (NCC) COMPLIANCE

MIN 25mm CAVITY FORMED USING TOP HATS*,

Z-SECTIONS* OR HELPING HANDS* @ 600 CTRS

#10 FASTENERS*

10mm MORTAR* JOINT

SEAL AND DRAIN AS REQUIRED FOR OVERALL WALL NCC

COMPLIANCE. ALL SEALANTS TO BE COMPATIBLE WITH

AVANTE BRICK FACINGS AND MORTAR

WINDOW SHROUD

MAX 31mm OVERALL AVANTE SYSTEM (RAIL AND BRICK SLIP)

MAX 10 mm

MIN

1

0m

m

MIN 10mm

230*76mm AVANTE BRICK FACINGS*

AVANTE RAIL CANTILEVER SPAN*

AVANTE RAIL CANTILEVER SPAN*

Page 11: DRAWING SHEET NUMBER REV. CORROSIVITY ENVIRONMENT. …€¦ · 8 horizontal expansion joint and slab edge flashing d06 ava-typ-d06 a 8 9 vertical expansion jointdetail d07 ava-typ-d07

©PGH Bricks and Pavers Pty Ltd 2017. This document should not be reproduced or communicated

without the prior written approval of PGH Bricks & Pavers Pty Ltd

Do not scale this drawing

DRAWING NUMBER

DRAWING TITLEDRAWN BYBY DATEDESCRIPTIONREV

REVISION

SHEET NO

PAPER SIZE

SCALE

A: 75 Townson Road, Schofields, NSW 2762

E: [email protected]

T: 61 2 9235 8000

F: 61 2 8362 9005

ABN 68 168 794 821

AINFORMATION

N/A

A3

11

A

P.A

11/04/2019

DOOR JAMB DETAILS

AVA-TYP-D09

11/04/2019P.A

AIR/WATER/VAPOUR BARRIER IF REQUIRED FOR OVERALL

WALL NATIONAL CONSTRUCTION CODE (NCC) COMPLIANCE

MIN 25mm CAVITY FORMED USING TOP HATS*,

Z-SECTIONS* OR HELPING HANDS* @ 600 CTRS

PRIMARY STRUCTURE

SEAL AS REQUIRED FOR OVERALL WALL NCC

COMPLIANCE. ALL SEALANTS TO BE COMPATIBLE

WITH AVANTE BRICK FACINGS AND MORTAR

10mm MORTAR* JOINT

AVANTE RAIL*

#10 FASTENERS*

DOOR JAMB

MAX 31mm OVERALL AVANTE SYSTEM (RAIL AND BRICK SLIP)

MIN 10mm

230*76mm AVANTE BRICK FACINGS*

AVANTE RAIL CANTILEVER SPAN*

Page 12: DRAWING SHEET NUMBER REV. CORROSIVITY ENVIRONMENT. …€¦ · 8 horizontal expansion joint and slab edge flashing d06 ava-typ-d06 a 8 9 vertical expansion jointdetail d07 ava-typ-d07

©PGH Bricks and Pavers Pty Ltd 2017. This document should not be reproduced or communicated

without the prior written approval of PGH Bricks & Pavers Pty Ltd

Do not scale this drawing

DRAWING NUMBER

DRAWING TITLEDRAWN BYBY DATEDESCRIPTIONREV

REVISION

SHEET NO

PAPER SIZE

SCALE

A: 75 Townson Road, Schofields, NSW 2762

E: [email protected]

T: 61 2 9235 8000

F: 61 2 8362 9005

ABN 68 168 794 821

AINFORMATION

N/A

A3

12

A

P.A

11/04/2019

TYPICAL AVANTE WINDOW HEAD DETAIL

AVA-TYP-D10

11/04/2019P.A

SCALE N/A

WINDOW HEAD DETAIL - BRICK REVEAL

01

PRIMARY STRUCTURE

SCALE N/A

WINDOW HEAD DETAIL - METAL REVEAL

02

230*76mm AVANTE BRICK FACINGS*

AVANTE RAIL*

10mm MORTAR* JOINT

#10 FASTENERS*

AIR/WATER/VAPOUR BARRIER IF

REQUIRED FOR OVERALL WALL

NATIONAL CONSTRUCTION CODE

(NCC) COMPLIANCE

MIN 25mm CAVITY FORMED

USING TOP HATS*, Z-SECTIONS*

OR HELPING HANDS* @ 600 CTRS

MAX 31mm OVERALL AVANTE

SYSTEM (RAIL AND BRICK SLIP)

PRIMARY STRUCTURE

230*110*76mm AVANTE PISTOL CORNER

SEAL AND DRAIN AS REQUIRED FOR OVERALL WALL

NCC COMPLIANCE. ALL SEALANTS TO BE COMPATIBLE

WITH AVANTE BRICK FACINGS AND MORTAR

SEAL AND DRAIN AS REQUIRED

FOR OVERALL WALL NCC

COMPLIANCE. ALL SEALANTS TO

BE COMPATIBLE WITH AVANTE

BRICK FACINGS AND MORTAR

WINDOW SHROUD

230*76mm AVANTE BRICK FACINGS*

AVANTE RAIL*

10mm MORTAR* JOINT

AIR/WATER/VAPOUR BARRIER IF

REQUIRED FOR OVERALL WALL

NATIONAL CONSTRUCTION CODE

(NCC) COMPLIANCE

MIN 25mm CAVITY FORMED USING

TOP HATS*, Z-SECTIONS* OR

HELPING HANDS* @ 600 CTRS

#10 FASTENERS*

MAX 31mm OVERALL AVANTE

SYSTEM (RAIL AND BRICK SLIP)

MIN 10mm

VERTICAL AVANTE RAIL*-MIN

RAIL ENGAGEMENT 50mm

MIN 10mm

HORIZONTAL TOP HAT TO SUPPORT

VERTICAL AVANTE RAIL*

2/#10 FASTENERS* FOR

EACH VERTICAL RAIL

AV

AN

TE

R

AIL

C

AN

TIL

EV

ER

S

PA

N*

AV

AN

TE

R

AIL

C

AN

TIL

EV

ER

S

PA

N*

Page 13: DRAWING SHEET NUMBER REV. CORROSIVITY ENVIRONMENT. …€¦ · 8 horizontal expansion joint and slab edge flashing d06 ava-typ-d06 a 8 9 vertical expansion jointdetail d07 ava-typ-d07

©PGH Bricks and Pavers Pty Ltd 2017. This document should not be reproduced or communicated

without the prior written approval of PGH Bricks & Pavers Pty Ltd

Do not scale this drawing

DRAWING NUMBER

DRAWING TITLEDRAWN BYBY DATEDESCRIPTIONREV

REVISION

SHEET NO

PAPER SIZE

SCALE

A: 75 Townson Road, Schofields, NSW 2762

E: [email protected]

T: 61 2 9235 8000

F: 61 2 8362 9005

ABN 68 168 794 821

AINFORMATION

N/A

A3

13

A

P.A

11/04/2019

TYPICAL AVANTE WINDOW SILL DETAIL

AVA-TYP-D11

11/04/2019P.A

SCALE N/A

WINDOW SILL DETAIL - BRICK REVEAL

01

SCALE N/A

WINDOW SILL DETAIL - METAL REVEAL

02

PRIMARY STRUCTURE

230*76mm AVANTE BRICK FACINGS*

AVANTE RAIL*

10mm MORTAR* JOINT

#10 FASTENERS*

AIR/WATER/VAPOUR BARRIER IF

REQUIRED FOR OVERALL WALL

NATIONAL CONSTRUCTION CODE

(NCC) COMPLIANCE

MIN 25mm CAVITY FORMED USING

TOP HATS*, Z-SECTIONS* OR

HELPING HANDS* @ 600 CTRS

MAX 31mm OVERALL AVANTE

SYSTEM (RAIL AND BRICK SLIP)

230*110*76mm AVANTE PISTOL CORNER

SEAL AS REQUIRED FOR OVERALL WALL

NCC COMPLIANCE. ALL SEALANTS TO BE

COMPATIBLE WITH AVANTE BRICK

FACINGS AND MORTAR

PRIMARY STRUCTURE

WINDOW SILL

AVANTE RAIL*

10mm MORTAR* JOINT

230*76mm AVANTE

BRICK FACINGS*

MAX 31mm OVERALL AVANTE

SYSTEM (RAIL AND BRICK SLIP)

MIN 25mm CAVITY FORMED USING

TOP HATS*, Z-SECTIONS* OR

HELPING HANDS* @ 600 CTRS

AIR/WATER/VAPOUR

BARRIER IF REQUIRED

FOR OVERALL WALL

NATIONAL CONSTRUCTION

CODE (NCC) COMPLIANCE

#10 FASTENERS*

SEAL AS REQUIRED FOR OVERALL

WALL NCC COMPLIANCE. ALL

SEALANTS TO BE COMPATIBLE WITH

AVANTE BRICK FACINGS AND

MORTAR

MIN 10mm

VERTICAL AVANTE RAIL*-MIN

RAIL ENGAGEMENT 50mm

HORIZONTAL TOP HAT TO SUPPORT

VERTICAL AVANTE RAIL*

2/#10 FASTENERS* FOR

EACH VERTICAL RAIL

MIN 6mm

AV

AN

TE

R

AIL

C

AN

TIL

EV

ER

S

PA

N*

AV

AN

TE

R

AIL

C

AN

TIL

EV

ER

S

PA

N*

Page 14: DRAWING SHEET NUMBER REV. CORROSIVITY ENVIRONMENT. …€¦ · 8 horizontal expansion joint and slab edge flashing d06 ava-typ-d06 a 8 9 vertical expansion jointdetail d07 ava-typ-d07

©PGH Bricks and Pavers Pty Ltd 2017. This document should not be reproduced or communicated

without the prior written approval of PGH Bricks & Pavers Pty Ltd

Do not scale this drawing

DRAWING NUMBER

DRAWING TITLEDRAWN BYBY DATEDESCRIPTIONREV

REVISION

SHEET NO

PAPER SIZE

SCALE

A: 75 Townson Road, Schofields, NSW 2762

E: [email protected]

T: 61 2 9235 8000

F: 61 2 8362 9005

ABN 68 168 794 821

AINFORMATION

N/A

A3

14

A

P.A

11/04/2019

TYPICAL AVANTE CORNER DETAILS

AVA-TYP-D12

11/04/2019P.A

SCALE N/A

EXTERNAL CORNER DETAIL

01

PRIMARY STRUCTURE

MAX 31mm OVERALL AVANTE

SYSTEM (RAIL AND BRICK SLIP)

AVANTE RAIL*

10mm MORTAR* JOINT

230*76mm AVANTE BRICK FACINGS*

AIR/WATER/VAPOUR BARRIER IF REQUIRED FOR OVERALL

WALL NATIONAL CONSTRUCTION CODE (NCC) COMPLIANCE

#10 FASTENERS*

SCALE N/A

INTERNAL CORNER DETAIL

02

MAX 31mm OVERALL AVANTE SYSTEM (RAIL AND BRICK SLIP)

MIN 25mm CAVITY FORMED USING TOP HATS*,

Z-SECTIONS* OR HELPING HANDS* @ 600 CTRS

AIR/WATER/VAPOUR BARRIER IF REQUIRED FOR OVERALL WALL

NATIONAL CONSTRUCTION CODE (NCC) COMPLIANCE

MIN 25mm CAVITY FORMED USING TOP HATS*,

Z-SECTIONS* OR HELPING HANDS* @ 600 CTRS

230*110*76mm AVANTE PISTOL CORNER

#10 FASTENERS*

10mm MORTAR* JOINT

CORNER ANGLE FIXED

TO THE BACK OF RAILS

PRIMARY STRUCTURE

MIN 15mm (VERTICAL EXPANSION JOINT)

INSTALL SHEAR BLOCK

@MAX 300 CTRS

230*110*76mm AVANTE

PISTOL CORNER

3m MAX EXPANSION JOINT DISTANCE

SEAL AND DRAIN AS REQUIRED

FOR OVERALL WALL NCC

COMPLIANCE. SEALANT TO SUIT

DESIGN BUILDING MOVEMENTS.

AVANTE RAIL CANTILEVER SPAN*

AV

AN

TE

R

AIL

C

AN

TIL

EV

ER

S

PA

N*

Page 15: DRAWING SHEET NUMBER REV. CORROSIVITY ENVIRONMENT. …€¦ · 8 horizontal expansion joint and slab edge flashing d06 ava-typ-d06 a 8 9 vertical expansion jointdetail d07 ava-typ-d07

©PGH Bricks and Pavers Pty Ltd 2017. This document should not be reproduced or communicated

without the prior written approval of PGH Bricks & Pavers Pty Ltd

Do not scale this drawing

DRAWING NUMBER

DRAWING TITLEDRAWN BYBY DATEDESCRIPTIONREV

REVISION

SHEET NO

PAPER SIZE

SCALE

A: 75 Townson Road, Schofields, NSW 2762

E: [email protected]

T: 61 2 9235 8000

F: 61 2 8362 9005

ABN 68 168 794 821

AINFORMATION

N/A

A3

15

A

P.A

11/04/2019

TYPICAL AVANTE DETAIL ABUTTING TO SOFFIT LINE

AVA-TYP-D13

11/04/2019P.A

PRIMARY STRUCTURE

MAX 31mm OVERALL AVANTE SYSTEM (RAIL AND BRICK SLIP)

AVANTE RAIL*

230*76mm AVANTE BRICK FACINGS*

AIR/WATER/VAPOUR BARRIER IF REQUIRED FOR OVERALL

WALL NATIONAL CONSTRUCTION CODE (NCC) COMPLIANCE

MIN 25mm CAVITY FORMED USING TOP HATS*,

Z-SECTIONS* OR HELPING HANDS* @ 600 CTRS

#10 FASTENERS*

10mm MORTAR* JOINT

SEAL AND DRAIN AS REQUIRED FOR OVERALL WALL NCC COMPLIANCE. ALL

SEALANTS TO BE COMPATIBLE WITH AVANTE BRICK FACINGS AND MORTAR

FLASHING IF REQUIRED FOR OVERALL WALL NCC COMPLIANCE

SOFFIT LINING

PRIMARY STRUCTURE

Page 16: DRAWING SHEET NUMBER REV. CORROSIVITY ENVIRONMENT. …€¦ · 8 horizontal expansion joint and slab edge flashing d06 ava-typ-d06 a 8 9 vertical expansion jointdetail d07 ava-typ-d07

©PGH Bricks and Pavers Pty Ltd 2017. This document should not be reproduced or communicated

without the prior written approval of PGH Bricks & Pavers Pty Ltd

Do not scale this drawing

DRAWING NUMBER

DRAWING TITLEDRAWN BYBY DATEDESCRIPTIONREV

REVISION

SHEET NO

PAPER SIZE

SCALE

A: 75 Townson Road, Schofields, NSW 2762

E: [email protected]

T: 61 2 9235 8000

F: 61 2 8362 9005

ABN 68 168 794 821

AINFORMATION

N/A

A3

16

A

P.A

11/04/2019

TYPICAL AVANTE DETAIL ABUTTING INTO TRADITIONAL BRICKWORK

AVA-TYP-D14

11/04/2019P.A

230*76mm AVANTE BRICK FACINGS*

MAX 31mm OVERALL AVANTE

SYSTEM (RAIL AND BRICK SLIP)

AVANTE RAIL*

10mm MORTAR* JOINT

#10 FASTENERS*

INTERNAL FINISHES

MIN 25mm CAVITY FORMED USING TOP HATS*,

Z-SECTIONS* OR HELPING HANDS* @ 600 CTRS

230*110*76mm TRADITIONAL BRICKWORK

SEAL AS REQUIRED FOR OVERALL WALL NCC

COMPLIANCE. ALL SEALANTS TO BE COMPATIBLE

WITH AVANTE BRICK FACINGS AND MORTAR

MIN 10mm