Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-1 TABLE OF CONTENTS General Information ................................................... 2-2 Elevations/Sizes: 1/4” & 1/8” Scale Single Units .................................................... 2-5 Twin Units ..................................................... 2-14 Triple Units .................................................... 2-21 4-Wide Units ................................................... 2-29 5-Wide Units ................................................... 2-31 Double-Hung Picture ........................................... 2-34 Double-Hung Transom .......................................... 2-44 Glazing Options ........................................................ 2-50 Jamb Extender Options ................................................. 2-51 Standard Mullion Options ............................................... 2-52 Lite Cut Information .................................................... 2-54 Unit Sizing Information ................................................. 2-56 Clear Opening Layout ................................................... 2-57 Section Details ........................................................ 2-58 W-2500 Double-Hung Windows
66
Embed
Double-Hung Windows9dc159b43a66b1fe0a49-bd2073f7c8dbd16f36eed639782493f0.r48.cf1.rackcdn.c…Architectural Detail Manual April 2013 JELD-WEN reserves the right to change specifications
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-1
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-2
Clad double hung windows feature fully operating upper and lower sash.Counterbalancing is achieved with helical spring extension systems hidden inweatherable PVC jambliners. Operating units are supplied with cam-type sashlocks installed. There are several hardware finish options. Refer to theSpecifications for available finish options.
MULTIPLE ASSEMBLIESClad double hung windows may be mulled beside other clad double hungs or clad picturewindows, or below clad transom windows, to fulfill a wide variety of needs. Factory assembledmulls are limited in height (100”), width (114”), and a total area (75 square feet).
GENERAL INFORMATION
Double-Hung Windows
W-2500
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-3
ELEVATION DRAWINGS UTILIZE A LIMITED NUMBER OF PROJECTED LINES TO PRODUCE A RUDIMENTARY DRAWING INTENDEDTO BE USED IN A SMALL GRAPHICAL SCALE. ELEVATIONS ARE VIEWED PERPENDICULAR FROM THE EXTERIOR OF THESTRUCTURE. IF MORE DIMENSIONS ARE NEEDED, USE THE SECTION DRAWINGS FOR MORE COMPLETE DEPICTIONS.
’25CDH’ INDICATESW2500 CLAD DOUBLE HUNG
THE FIRST TWO NUMBERSINDICATE THE UNIT WIDTH
THE LAST TWO NUMBERS INDICATETHE UNITS HEIGHT
BOOK CODE
OUTSIDE OF FRAME.
ROUGH OPENINGDIMENSIONS ARE
IN BOLD TEXT.
Masonry Openings for Brickmould, Flat & Adams Casing.Vertical measurements include sillnose.(Subtract 1/2” from Masonry Opening for Unit Size)
1. ALL UNITS SHOWN ARE AVAILABLE AS OPERATORS ONLY.
2. UNIT ELEVATIONS ARE SHOWN WITHOUT EXTERIOR TRIM.
3. ALL OPERATING SASH ARE INSTALLED WITH VINYL JAMB LINERS ANDOPERATED WITH AN INTERNAL HELICAL SPRING SYSTEM.
4. DIMENSIONAL VALUES IN BRACKETS ARE MILLIMETER CONVERSIONS.
25CDH2136
UNIT WIDTH
UNIT HEIGHT
LOWER SASHVERTICAL GLASS
25CDH2148C24
COTTAGE & REVERSE COTTAGEBOOK CODES
C = COTTAGER = REVERSE COTTAGE
ELEVATION SYMBOL LEGEND:
BASIC UNIT CLEAR OPENING EXCEEDS 20” IN WIDTH, 24” INHEIGHT & A MINIMUM OF 5.7 SQ. FT.
NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITHSTANDARD GLAZING.
##
E
SEE SYMBOL LEGEND BELOW
DAYLIGHT OPENING
##
ELEVATION NOTES
Double-Hung Windows
W-2500
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-4
SASH TILTING FOR WASHINGThe Custom Double Hung window will allow the sash to be tilted or removed for easycleaning.
DOUBLE HUNG OPERATION:When the sash are locked at thecheck rails the sash are closed andsealed in the sash opening of theframe.
When the sash are unlocked thelower sash travels vertically to anyposition desired. The upper sash canalso be positioned as desired.
OPERATION & SASH TILTING
Double-Hung Windows
W-2500
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-5
SINGLE UNITS
E1 UNITS WITH AN E1 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH A DP35 SILL STOP, BUT NOT WITH A DP 50 SILL STOP.E2 UNITS WITH AN E2 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH EITHER A DP35 OR A DP 50 SILL STOP.E3 UNITS WITH AN E3 EGRESS DESIGNATION MEET 5.7 SQ FT EGRESS WITH A DP35 SILL STOP, BUT NOT WITH A DP 50 SILL STOP.E4 UNITS WITH AN E4 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH EITHER A DP35 OR A DP 50 SILL STOP.
ELEVATION SYMBOL LEGEND:
##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.
VALUES IN () ARE IN MILLIMETER CONVERSIONS.
##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.
VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
E1 UNITS WITH AN E1 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH A DP35 SILL STOP, BUT NOT WITH A DP 50 SILL STOP.E2 UNITS WITH AN E2 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH EITHER A DP35 OR A DP 50 SILL STOP.E3 UNITS WITH AN E3 EGRESS DESIGNATION MEET 5.7 SQ FT EGRESS WITH A DP35 SILL STOP, BUT NOT WITH A DP 50 SILL STOP.E4 UNITS WITH AN E4 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH EITHER A DP35 OR A DP 50 SILL STOP.
ELEVATION SYMBOL LEGEND:
##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.
VALUES IN () ARE IN MILLIMETER CONVERSIONS.
##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.
VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/4” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-7
E1 UNITS WITH AN E1 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH A DP35 SILL STOP, BUT NOT WITH A DP 50 SILL STOP.E2 UNITS WITH AN E2 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH EITHER A DP35 OR A DP 50 SILL STOP.E3 UNITS WITH AN E3 EGRESS DESIGNATION MEET 5.7 SQ FT EGRESS WITH A DP35 SILL STOP, BUT NOT WITH A DP 50 SILL STOP.E4 UNITS WITH AN E4 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH EITHER A DP35 OR A DP 50 SILL STOP.
ELEVATION SYMBOL LEGEND:
##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.
VALUES IN () ARE IN MILLIMETER CONVERSIONS.
##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.
VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
N INDICATES NOMINALSIZING.
Double-Hung Windows
W-2500
SCALE: 1/4” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-8
E1 UNITS WITH AN E1 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH A DP35 SILL STOP, BUT NOT WITH A DP 50 SILL STOP.E2 UNITS WITH AN E2 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH EITHER A DP35 OR A DP 50 SILL STOP.E3 UNITS WITH AN E3 EGRESS DESIGNATION MEET 5.7 SQ FT EGRESS WITH A DP35 SILL STOP, BUT NOT WITH A DP 50 SILL STOP.E4 UNITS WITH AN E4 EGRESS DESIGNATION MEET 5.0 SQ FT EGRESS WITH EITHER A DP35 OR A DP 50 SILL STOP.
ELEVATION SYMBOL LEGEND:
##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.
VALUES IN () ARE IN MILLIMETER CONVERSIONS.
##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.
VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
N INDICATES NOMINALSIZING.
Double-Hung Windows
W-2500
SCALE: 1/4” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-9
SINGLE UNITSWITH 15” TRANSOM
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-11
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-12
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-13
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-14
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-15
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-16
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-17
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-18
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-19
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-20
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-21
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-22
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-23
TRIPLE UNITS - NOMINAL
DAYLIGHT OPENINGFRAME SIZE
ROUGH OPENINGUNIT SIZE
E
E
E
E
E
E
E
25CDH2036N-3
25CDH2042N-3
25CDH2048N-3
25CDH2054N-3
25CDH2060N-3
25CDH2066N-3
25CDH2072N-3
25CDH2436N-3
25CDH2442N-3
25CDH2448N-3
25CDH2454N-3
25CDH2460N-3
25CDH2466N-3
25CDH2472N-3
25CDH2836N-3
25CDH2842N-3
25CDH2848N-3
25CDH2854N-3
25CDH2860N-3
25CDH2866N-3
25CDH2872N-3
25CDH3236N-3
25CDH3242N-3
25CDH3248N-3
25CDH3254N-3
25CDH3260N-3
25CDH3266N-3
25CDH3272N-3
25CDH3636N-3
25CDH3642N-3
25CDH3648N-3
25CDH3654N-3
25CDH3660N-3
25CDH3666N-3
25CDH3672N-3
13 15/16”(354)[3]59 1/4”(1505)
60”(1524)62”(1575)
17 15/16”(455)[3]71 1/4”(1810)
72”(1829)74”(1880)
21 15/16”(557)[3]83 1/4”(2115)
84”(2134)86”(2184)
25 15/16”(659)[3]95 1/4”(2419)
96”(2438)98”(2489)
29 15/16”(760)[3]107 1/4”(2724)
108”(2743)110”(2794)
145/
16”(
364)
[2]
351/
4”(8
95)
36”(
914)
38”(
965)
411/
4”(1
048)
42”(
1067
)44
”(11
18)
471/
4”(1
200)
48”(
1219
)50
”(12
70)
531/
4”(1
353)
54”(
1372
)56
”(14
22)
591/
4”(1
505)
60”(
1524
)62
”(15
75)
651/
4”(1
657)
66”(
1676
)68
”(17
27)
711/
4”(1
810)
72”(
1829
)74
”(18
80)
175/
16”(
440)
[2]
205/
16”(
515)
[2]
235/
16”(
592)
[2]
265/
16”(
668)
[2]
295/
16”(
745)
[2]
325/
16”(
821)
[2]
N INDICATES NOMINALSIZING.
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-24
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-25
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-26
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-27
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-28
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-29
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-30
E UNIT MEETS EGRESS REQUIREMENTS FOR IRC CODE. STATE AND LOCAL EGRESS CODES MAY DIFFER. ALWAYS REFER TO LOCAL BUILDING CODES FOR COMPLETE REQUIREMENTS.CHECK WITH LOCAL OFFICIALS TO ENSURE COMPLIANCE BEFORE INSTALLING THE UNIT.SEE NOTES ON SINGLE UNIT ELEVATIONS FOR SPECIFIC EGRESS CAPABILITY.
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Double-Hung Windows
W-2500
SCALE: 1/8” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-31
5 WIDE UNITS
ELEVATION SYMBOL LEGEND:VALUES IN () ARE IN MILLIMETER CONVERSIONS.VALUES IN [] ARE NUMBER OF DAYLIGHT OPENINGS PER UNIT.
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-33
ELEVATION DRAWINGS UTILIZE A LIMITED NUMBER OF PROJECTED LINES TO PRODUCE A RUDIMENTARY DRAWING INTENDEDTO BE USED IN A SMALL GRAPHICAL SCALE. ELEVATIONS ARE VIEWED PERPENDICULAR FROM THE EXTERIOR OF THESTRUCTURE. IF MORE DIMENSIONS ARE NEEDED, USE THE SECTION DRAWINGS FOR MORE COMPLETE DEPICTIONS.
1. ALL UNITS SHOWN ARE AVAILABLE AS STATIONARY ONLY.
2. UNIT ELEVATIONS ARE SHOWN WITHOUT EXTERIOR TRIM.
3. DIMENSIONAL VALUES IN BRACKETS ARE MILLIMETER CONVERSIONS.
GENERAL DOUBLE HUNG TRANSOM NOTES
25CDHP2124
ROUGH OPENINGDIMENSIONS ARE
IN BOLD TEXT.
M.O. Adams/Flat CasingRough Opening
M.O. Brickmould
Frame Size
Masonry Openings for Brickmould, Flat & Adams Casing.Vertical measurements include sillnose.(Subtract 1/2” from Masonry Opening for Unit Size)
OUTSIDE OFFRAME.
’25CDHP’ INDICATESW2500 CLAD DOUBLE HUNG TRANSOM
BOOK CODE
THE LAST TWO NUMBERS INDICATETHE UNITS HEIGHTTHE FIRST TWO NUMBERS
INDICATE THE UNIT WIDTH
SEE SYMBOL LEGEND BELOW
ELEVATION SYMBOL LEGEND:
NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITHSTANDARD GLAZING.
##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.VALUES IN () ARE IN MILLIMETER CONVERSIONS.
##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.
Double-Hung Windows
W-2500
SCALE: 1/4” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-37
PICTURE UNITS
44”(1118)49 3/8”(1254)50 1/8”(1273)52 1/8”(1324)
42 3/4”(1086)48”(1219)
48 3/4”(1238)50 3/4”(1289)
48 3/4”(1238)54”(1372)
54 3/4”(1391)56 3/4”(1441)
54 3/4”(1391)60”(1524)
60 3/4”(1543)62 3/4”(1594)
25CDHP4812 25CDHP4912 25CDHP5412 25CDHP6012
25CDHP4818 25CDHP4918 25CDHP5418 25CDHP6018
25CDHP4824 25CDHP4924 25CDHP5424 25CDHP6024
25CDHP4830 25CDHP4930 25CDHP5430 25CDHP6030
25CDHP4836 25CDHP4936 25CDHP5436 25CDHP6036
25CDHP4840 25CDHP4940 25CDHP5440 25CDHP6040
25CDHP4842 25CDHP4942 25CDHP5442 25CDHP6042
25CDHP4848 25CDHP4948 25CDHP5448 25CDHP6048
35*50**
35*50**
35**50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
12”(
305)
123/
4”(3
24)
143/
4”(3
75)
71/
4”(1
84)
18”(
457)
183/
4”(4
76)
203/
4”(5
27)
131/
4”(3
37)
24”(
610)
243/
4”(6
29)
263/
4”(6
79)
191/
4”(4
89)
30”(
762)
303/
4”(7
81)
323/
4”(8
32)
251/
4”(6
41)
36”(
914)
363/
4”(9
33)
383/
4”(9
84)
311/
4”(7
94)
40”(
1016
)40
3/4”
(103
5)42
3/4”
(108
6)
351/
4”(8
95)
42”(
1067
)42
3/4”
(108
6)44
3/4”
(113
7)
371/
4”(9
46)
48”(
1219
)48
3/4”
(123
8)50
3/4”
(128
9)
431/
4”(1
099)
DAYLIGHT OPENINGFRAME SIZE
ROUGH OPENINGUNIT SIZE
ELEVATION SYMBOL LEGEND:
##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.VALUES IN () ARE IN MILLIMETER CONVERSIONS.
##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.
Double-Hung Windows
W-2500
SCALE: 1/4” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-38
PICTURE UNITS
25CDHP4854 25CDHP4954 25CDHP5454 25CDHP6054
25CDHP4856 25CDHP4956 25CDHP5456 25CDHP6056
25CDHP4860 25CDHP4960 25CDHP5460 25CDHP6060
25CDHP4864 25CDHP4964 25CDHP5464 25CDHP6064
25CDHP4868 25CDHP4968 25CDHP5468 25CDHP6068
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
54”(
1372
)54
3/4”
(139
1)56
3/4”
(144
1)
491/
4”(1
251)
56”(
1422
)56
3/4”
(144
1)58
3/4”
(149
2)
511/
4”(1
302)
60”(
1524
)62
3/4”
(159
4)64
3/4”
(164
5)
551/
4”(1
403)
64”(
1626
)64
3/4”
(164
5)66
3/4”
(169
5)
591/
4”(1
505)
68”(
1727
)68
3/4”
(174
6)70
3/4”
(179
7)
631/
4”(1
607)
DAYLIGHT OPENINGFRAME SIZE
ROUGH OPENINGUNIT SIZE
44”(1118)49 3/8”(1254)50 1/8”(1273)52 1/8”(1324)
42 3/4”(1086)48”(1219)
48 3/4”(1238)50 3/4”(1289)
48 3/4”(1238)54”(1372)
54 3/4”(1391)56 3/4”(1441)
54 3/4”(1391)60”(1524)
60 3/4”(1543)62 3/4”(1594)
ELEVATION SYMBOL LEGEND:
##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.VALUES IN () ARE IN MILLIMETER CONVERSIONS.
##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.
Double-Hung Windows
W-2500
SCALE: 1/4” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-39
PICTURE UNITS
25CDHP4872 25CDHP4972 25CDHP5472 25CDHP6072
25CDHP4876 25CDHP4976 25CDHP5476 25CDHP6076
25CDHP4888 25CDHP4988 25CDHP5488 25CDHP6088
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
72”(
1829
)72
3/4”
(184
8)74
3/4”
(189
9)
671/
4”(1
708)
76”(
1930
)76
3/4”
(194
9)78
3/4”
(200
0)
711/
4”(1
810)
88”(
2235
)88
3/4”
(225
4)90
3/4”
(230
5)
831/
4”(2
115)
DAYLIGHT OPENINGFRAME SIZE
ROUGH OPENINGUNIT SIZE
44”(1118)49 3/8”(1254)50 1/8”(1273)52 1/8”(1324)
42 3/4”(1086)48”(1219)
48 3/4”(1238)50 3/4”(1289)
48 3/4”(1238)54”(1372)
54 3/4”(1391)56 3/4”(1441)
54 3/4”(1391)60”(1524)
60 3/4”(1543)62 3/4”(1594)
ELEVATION SYMBOL LEGEND:
##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.VALUES IN () ARE IN MILLIMETER CONVERSIONS.
##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.
Double-Hung Windows
W-2500
SCALE: 1/4” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-40
PICTURE UNITS
56”(1422)61 3/8”(1559)62 1/8”(1578)64 1/8”(1629)
60 3/4”(1543)66”(1676)
66 3/4”(1695)68 3/4”(1746)
66 3/4”(1695)72”(1829)
72 3/4”(1848)74 3/4”(1899)
25CDHP6112 25CDHP6612 25CDHP7212
25CDHP6118 25CDHP6618 25CDHP7218
25CDHP6124 25CDHP6624 25CDHP7224
25CDHP6130 25CDHP6630 25CDHP7230
25CDHP6136 25CDHP6636 25CDHP7236
25CDHP6140 25CDHP6640 25CDHP7240
25CDHP6142 25CDHP6642 25CDHP7242
25CDHP6148 25CDHP6648 25CDHP7248
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
12”(
305)
123/
4”(3
24)
143/
4”(3
75)
71/
4”(1
84)
18”(
457)
183/
4”(4
76)
203/
4”(5
27)
131/
4”(3
37)
24”(
610)
243/
4”(6
29)
263/
4”(6
79)
191/
4”(4
89)
30”(
762)
303/
4”(7
81)
323/
4”(8
32)
251/
4”(6
41)
36”(
914)
363/
4”(9
33)
383/
4”(9
84)
311/
4”(7
94)
40”(
1016
)40
3/4”
(103
5)42
3/4”
(108
6)
351/
4”(8
95)
42”(
1067
)42
3/4”
(108
6)44
3/4”
(113
7)
371/
4”(9
46)
48”(
1219
)48
3/4”
(123
8)50
3/4”
(128
9)
431/
4”(1
099)
DAYLIGHT OPENINGFRAME SIZE
ROUGH OPENINGUNIT SIZE
ELEVATION SYMBOL LEGEND:
##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.VALUES IN () ARE IN MILLIMETER CONVERSIONS.
##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.
Double-Hung Windows
W-2500
SCALE: 1/4” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-41
PICTURE UNITS
25CDHP6154 25CDHP6654 25CDHP7254
25CDHP6156 25CDHP6656 25CDHP7256
25CDHP6160 25CDHP6660 25CDHP7260
25CDHP6164 25CDHP6664 25CDHP7264
25CDHP6168 25CDHP6668 25CDHP7268
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
54”(
1372
)54
3/4”
(139
1)56
3/4”
(144
1)
491/
4”(1
251)
56”(
1422
)56
3/4”
(144
1)58
3/4”
(149
2)
511/
4”(1
302)
60”(
1524
)62
3/4”
(159
4)64
3/4”
(164
5)
551/
4”(1
403)
64”(
1626
)64
3/4”
(164
5)66
3/4”
(169
5)
591/
4”(1
505)
68”(
1727
)68
3/4”
(174
6)70
3/4”
(179
7)
631/
4”(1
607)
DAYLIGHT OPENINGFRAME SIZE
ROUGH OPENINGUNIT SIZE
56”(1422)61 3/8”(1559)62 1/8”(1578)64 1/8”(1629)
60 3/4”(1543)66”(1676)
66 3/4”(1695)68 3/4”(1746)
66 3/4”(1695)72”(1829)
72 3/4”(1848)74 3/4”(1899)
ELEVATION SYMBOL LEGEND:
##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.VALUES IN () ARE IN MILLIMETER CONVERSIONS.
##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.
Double-Hung Windows
W-2500
SCALE: 1/4” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-42
PICTURE UNITS
25CDHP6172 25CDHP6672 25CDHP7272
25CDHP6176 25CDHP6676 25CDHP7276
25CDHP6188 25CDHP6688 25CDHP7288
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
35*50**
72”(
1829
)72
3/4”
(184
8)74
3/4”
(189
9)
671/
4”(1
708)
76”(
1930
)76
3/4”
(194
9)78
3/4”
(200
0)
711/
4”(1
810)
88”(
2235
)88
3/4”
(225
4)90
3/4”
(230
5)
831/
4”(2
115)
DAYLIGHT OPENINGFRAME SIZE
ROUGH OPENINGUNIT SIZE
56”(1422)61 3/8”(1559)62 1/8”(1578)64 1/8”(1629)
60 3/4”(1543)66”(1676)
66 3/4”(1695)68 3/4”(1746)
66 3/4”(1695)72”(1829)
72 3/4”(1848)74 3/4”(1899)
ELEVATION SYMBOL LEGEND:
##* NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITH STANDARD GLAZING.VALUES IN () ARE IN MILLIMETER CONVERSIONS.
##** NUMBER INDICATES OPTIONAL DESIGN PRESSURE (DP) RATING.
Double-Hung Windows
W-2500
SCALE: 1/4” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-43
ELEVATION DRAWINGS UTILIZE A LIMITED NUMBER OF PROJECTED LINES TO PRODUCE A RUDIMENTARY DRAWING INTENDEDTO BE USED IN A SMALL GRAPHICAL SCALE. ELEVATIONS ARE VIEWED PERPENDICULAR FROM THE EXTERIOR OF THESTRUCTURE. IF MORE DIMENSIONS ARE NEEDED, USE THE SECTION DRAWINGS FOR MORE COMPLETE DEPICTIONS.
1. ALL UNITS SHOWN ARE AVAILABLE AS STATIONARY ONLY.
2. UNIT ELEVATIONS ARE SHOWN WITHOUT EXTERIOR TRIM.
3. DIMENSIONAL VALUES IN BRACKETS ARE MILLIMETER CONVERSIONS.
4. UNIT SHOWN IS FOR A W-2500 DH TRANSOM WITH STANDARD SASH, THETRADITION SASH OPTION WILL HAVE A DIFFERENT DAYLIGHT OPENINGVALUE.
GENERAL DOUBLE HUNG TRANSOM NOTES
25CDHT2124
ROUGH OPENINGDIMENSIONS ARE
IN BOLD TEXT.
M.O. Adams/Flat CasingRough Opening
M.O. Brickmould
Frame Size
Masonry Openings for Brickmould, Flat & Adams Casing.Vertical measurements include sillnose.(Subtract 1/2” from Masonry Opening for Unit Size)
OUTSIDE OFFRAME.
’25CDHT’ INDICATESW2500 CLAD DOUBLE HUNG TRANSOM
BOOK CODE
THE LAST TWO NUMBERS INDICATETHE UNITS HEIGHTTHE FIRST TWO NUMBERS
INDICATE THE UNIT WIDTH
SEE SYMBOL LEGEND BELOW
ELEVATION SYMBOL LEGEND:
NUMBER INDICATES DESIGN PRESSURE (DP) RATING WITHSTANDARD GLAZING.
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-54
LITE CUT INFORMATION
UNEVEN
GOTHIC
VERTICAL PRAIRIE
RADIUSDIAMOND
RECTANGULAR
BAR ALIGNMENT
Alignment of divided lite muntin bars from one window to the
next is often required by fine architectural design. Wood
grilles, GBG’s, and Simulated Divided Lites may be specified
with muntin bars aligned.
LITE CUT OPTIONS
Special lite cut patterns can include a wide
variety of straight line and radius patterns.
The illustrations shown here represent just a
few of the possibilities. Rectangular,
horizontal, vertical and Prairie lite patterns
are available in all standard size clad double
hung windows. Uneven, diamond, radius
and Gothic lite cuts are available, subject to
approval. Approvals are based on the ability
to fulfill the design requirement while
maintaining the construction integrity of the
finished product.
Clad double hung windows are available with removable grilles in 7/8” Full surround or beaded SDL only, 5/8” flator 23/32” contour grilles between the glass (GBG) and Simulated Divided Lites. Standard lite cuts are rectangular,.
W-2500
Double-Hung Windows
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-55
DIVIDED LITE OPTIONS
NOTES:ALL GLASS AND AIRSPACE DIMENSIONS PER CURRENT CARDINAL GLASS SPECSLITES WITH SHAPES, ANGLES, OR RADII OUTSIDE THE LISEC BENDERCAPABILITIES FOR STAINLESS STEEL WARM EDGE SPACER WILL HAVEALUMINUM BOX SPACER WITH THE SAME AIRSPACE DIMENSION SHOWN HERE
5/8” GRILLE 23/32” GRILLE
0.625 0.709
0.156
7/8” SDL
0.625
0.2500 0.2500
5/8” GRILLE 23/32” GRILLE
0.187 0.217
7/8” SDL
0.187
0.2500 0.2500
0.150 0.156
0.625 0.709 0.625
W-2500
Double-Hung Windows
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-56
DRIP CAP & NAILING FLANGE
STANDARD OFFERING
ROUGH OPENING IS ALWAYS 3/4” OVERROUGH OPENING:
FRAME SIZE OF THE WINDOW
EXTREME SIZE OF THE WINDOW
UNITS WITH NO TRIM AND SILL NOSE:
(DRIP CAP & NAILING FLANGE ARENOT ADDED TO ANY UNIT SIZING)
MASONRY OPENING IS ALWAYS 1/2” OVERTHE UNIT SIZE OF THE WINDOW
WITH OR WITHOUT TRIM
UNIT SIZE IS ALWAYS THE
UNIT SIZE = FRAME SIZE
MASONRY OPENING:
GENERAL NOTES:
FRAME TO TRIMDIMENSIONS
TYPICAL FOR HEAD & SIDES
NON-STANDARD UNIT SIZINGEXTERIOR TRIM MUST USE SILL NOSE
FRAME = UNIT SIZEUNIT SIZE
UN
ITSI
ZEFR
AM
E=
UN
ITSI
ZEHORIZONTAL
ROUGH OPENING
3/8” [10]3/8” [10]
3/4” [19]
VER
TIC
AL
RO
UG
HO
PEN
ING
&A
DA
MS
CA
SIN
GFR
AM
E+
41/
16”
[104
]
31/
2”FL
AT
CA
SIN
G
FRA
ME
+2
9/16
”[6
5]BR
ICK
MO
ULD
UN
ITSI
ZE
UN
ITSI
ZE
& ADAMS CASING3 1/2” FLAT CASING
UNIT SIZE
FRAME + 3” [76]
UNIT SIZEBRICKMOULD
FRAME + 6” [152]
1 1/2” [38]BRICKMOULD
3” [76]3” FLAT &ADAMS CASING
UNIT SIZING, ROUGH OPENINGS& MASONRY OPENINGS
W-2500
Double-Hung Windows
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-57
REVERSE COTTAGE WINDOW
COTTAGE & REVERSE COTTAGEConsult the Design Data Tables for clear opening information. For dimensional units, contact Jeld-Wen - Bend Window Division, Technical ServicesDepartment for clear opening information.
DOUBLE HUNG WINDOW
COTTAGE WINDOW
CLEAR OPENING FORMULA
Frame Width - 3 3/8” = Clear Opening
DOUBLE HUNG
VERTICAL
HORIZONTAL
CLEAR OPENING
2 27/64” [62]
CLEAR OPENING
1 11/16” [43]1 11/16” [43]
CLEAR OPENING
1 11/16” [43]1 11/16” [43]
CLEAR OPENING
1 11/16” [43]1 11/16” [43]
2 27/64” [62]
CLEAR OPENING
2 27/64” [62]
CLEAR OPENING
(Frame Height / 2) - 3 15/16” = Clear Opening
CLEAR OPENING LAYOUTDP35 SILL
W-2500
Double-Hung Windows
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-58
VERTICAL SECTION
Day
light
Ope
ning
Gla
ssSi
ze
Sash
Size
Fram
eSi
ze
Roug
hO
peni
ng
1/2”
1”
1 11/16”
3/4”1/2”
3/4”
Day
light
Ope
ning
Gla
ssSi
ze
Sash
Size
Scre
enSi
ze
Uni
tSi
ze
1 1/4”
5 13/16”
4 9/16”
1 1/4”
5 13/16”
4 9/16”2”
1/2”
3/4”
2 5/16”
1/2”13/16”
SINGLE UNITS
Double-Hung Windows
W-2500
SCALE: 6” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-59
HORIZONTAL SECTION
Daylight Opening
Glass Size
Sash Size
Frame Size
Rough Opening
3/8” 3/8”
1/2” 1/2”
3/4”
1 7/16”
3/4”
1 7/16”
1 1/4”
5 13/16”
4 9/16”
1 1/4”
5 13/16”
4 9/16”
Sash Size
Glass Size
Screen Size
Unit Size
3/4”
1/2”
2 5/16”
3/4”
2 5/16”
1/2”
SINGLE UNITS
Double-Hung Windows
W-2500
SCALE: 6” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-60
HORIZONTAL SECTION
Daylight Opening
Glass Size
Sash Size
Frame Size
Rough Opening
3/8” 3/8”
1/2” 1/2”
3/4”
1 7/16”
3/4”
1 7/16”
1 1/4”
5 13/16”
4 9/16”
1 1/4”
5 13/16”
4 9/16”
Sash Size
Glass Size
Screen Size
Unit Size
3/4”
3/8”
2 7/16”
3/4”
2 7/16”
3/8”
DOUBLE-HUNG UNITSWITH CONCEALED JAMB LINER
Double-Hung Windows
W-2500
SCALE: 6” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-61
VERTICAL SECTION
Day
light
Ope
ning
Gla
ssSi
ze
Sash
Size
Fram
eSi
ze
Roug
hO
peni
ng
1/2”
3/4”
1 5/8”
2 1/16”
1/2”
Day
light
Ope
ning
Gla
ssSi
ze
Sash
Size
Scre
enSi
ze
Uni
tSi
ze
1 1/4”
5 13/16”
4 9/16”
5 13/16”
4 9/16”
2”
1/2”
2 1/16”
1/2”
13/16”
3/4”2 5/16”
DOUBLE-HUNG UNITSWITH TRADITIONAL SASH PACK
Double-Hung Windows
W-2500
SCALE: 6” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-62
HORIZONTAL SECTION
Daylight Opening
Glass Size
Sash Size
Frame Size
Rough Opening
3/8” 3/8”
1/2” 1/2”
1 1/4”
1 7/16”
1 1/4”
1 7/16”
1 1/4”
5 13/16”
4 9/16”
1 1/4”
5 13/16”
4 9/16”
Daylight Opening
Sash Size
Glass Size
Screen Size
Unit Size
1/2” 1/2”
1 1/4”
1/2”
2 5/16”
1 1/4”
2 5/16”
1/2”
DOUBLE-HUNG UNITSWITH TRADITIONAL SASH PACK
Double-Hung Windows
W-2500
SCALE: 6” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-63
HORIZONTAL SECTION
1 3/8”
5 13/16”
2 1/2”
5 5/16”
DOUBLE-HUNG UNITS - MULLION
Double-Hung Windows
W-2500
SCALE: 6” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-64
VERTICAL SECTION
Day
light
Ope
ning
Gla
ssSi
ze
Sash
Size
Fram
eSi
ze
Roug
hO
peni
ng
3/4”1 1/4”
5 13/16”
4 9/16”
1 1/4”
5 13/16”
4 9/16”
Uni
tSi
ze
1/2”
3/4”
11/16”
1 11/16”
3/4”
1/2”
IN-SASH PICTURE/TRANSOM
Double-Hung Windows
W-2500
SCALE: 6” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-65
HORIZONTAL SECTION
Daylight Opening
Glass Size
Sash Size
Frame Size
Rough Opening
1/2”
1 7/16”
3/4”
1 7/16”
3/4”
1/2”
3/8” 3/8”
1 1/4”
5 13/16”
4 9/16”
1 1/4”
5 13/16”
4 9/16”
Unit Size
IN-SASH PICTURE/TRANSOM
Double-Hung Windows
W-2500
SCALE: 6” = 1’
Architectural Detail ManualApril 2013 JELD-WEN reserves the right to change specifications without notice. Page 2-66