Top Banner
1 A+/A+ COP and EER efficiencies Between 7,000-10,000 BTU/hr of Integrated heat The PTTW The PTTW - - 10 10 - - EC Monobloc EC Monobloc Heat Pump Heat Pump - - ARI ARI - - V1.1 V1.1
24

Double Duct Interior Mount Heat Pump

May 14, 2015

Download

Business

dgeisert

A single chassis heat pump. Ideal for light commercial, residential, and historical buildings. NO refrigerant line-virtually hang, plug, and play.
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Double Duct Interior Mount Heat Pump

1

• A+/A+ COP and EER efficiencies• Between 7,000-10,000 BTU/hr of Integrated heat

The PTTWThe PTTW--1010--EC Monobloc EC Monobloc Heat PumpHeat Pump

--ARIARI--V1.1V1.1

Page 2: Double Duct Interior Mount Heat Pump

CONTENTSCONTENTSPage

1. Product Line Introduction 3,4

2. Product Specifications 5,6

3. Product Features Plug-and-play installation 7 Indoor appearance of installed unit 8 Outdoor appearance of installed unit 9 Heat pump and air conditioner 10 Sound performance 11 Cold weather operation 12 Tropical condition operation 13 Energy Performance 14 Product Comparison 15 Control system 16 Indoor air quality solution 17 Fresh-air intake system 18 Condensate drainage removal system 19 BMS enabled data controllers 20 Customized panel solutions 21

4. Dimensional Drawings 222

Page 3: Double Duct Interior Mount Heat Pump

1. Product Line Introduction1. Product Line Introduction

Commercial Advantages: modern and attractive unit outlook suitable for high-end residential and

commercial applications

package product suitable for retail, direct sales and professional HVAC channels

plug-and-play installation without brazing or refrigerant charging required

suitable for hotels, historical buildings, government housing and other

buildings with restrictions on outdoor units or refrigerant piping distance

customized panel designs and commercial solutions available

3

Page 4: Double Duct Interior Mount Heat Pump

1. Product Line Introduction1. Product Line Introduction

Technical Advantages:

Next generation product design and construction

Market leading energy efficiency

Market leading sound performance (42 dBa to 48 dBa indoor SPL)

Market leading operating range (5°F to 125.6°F) with up to

7000 BTU/hr integrated electric heating for cold weather operation

Flexible condensate drainage solutions

Multiple fresh air intake solutions

Fully enabled MODBUS solution with optional local PC host control program

(controls up to 400 units)

4

Page 5: Double Duct Interior Mount Heat Pump

2. Product Specifications2. Product Specifications

5

MODEL PTTW-10-EC

AirflowH

ft3 / h15,890

M 14,120L 12,360

Cooling capacity Btu / h 9,890Heating capacity Btu / h 10,060Electric Heater Capacity Btu / h 6800EER Btu / W 11.16COP Btu / Btu 3.54

Noise level @ 3.28ft

IndoorH

dB / A48

M 45.5L 42.8

Outdoor *H

dB / A56.5 (53)

M -L 41.6 (38.1)

Electrical insulation protection class IWater proof class IPX4Dehumidification gal / h 0.217All capacities are based on: cooling: indoor 80.6ºF DB, 66.2ºF WB, outdoor 95ºF DB, 75.2ºF WB 09 V.1.0

heating: indoor 68ºF DB, outdoor 44.6ºF DB, 42.8ºF WB* Values in parentheses refer to outdoor sound pressure levels with optional sound attenuation device installed

Page 6: Double Duct Interior Mount Heat Pump

2. Product Specifications 2. Product Specifications -- contcont’’dd

6

MODEL PTTW-10-EC

Power supply V / Ph / Hz 220-240 / 1 / 60

Power inputCooling W 885Heating W 830

Running currentCooling A 4.1Heating A 3.88

Start currentCooling A 12.3Heating A 11.6

Electric heater running current A 2.24Compressor ROTARYRefrigerant control CAPILLARYRefrigerant charge lb 1.43Refrigerant type R410A

DimensionsWidth

in39.37

Height 22.83Depth 9.65

Gross weight lb 99.2109 V.1.0

Page 7: Double Duct Interior Mount Heat Pump

3. Product Features 3. Product Features -- Plug-and-play installation

Installation - in 3 quick and easy steps:

STEP 1: Measure and drill two 6.38” diameter holes and one

0.79” diameter hole for condensate discharge in

outer building wall

STEP 2: Install external grilles, intake and discharge air hoses,

condensate drainage line and mounting brackets

STEP 3: Mount unit, connect wiring and run

Notes:

Installation kit including air intake and discharge hoses, wall brackets and condensate

drainage line supplied as standard

No welding, brazing, or refrigerant charging required for installation

7

Page 8: Double Duct Interior Mount Heat Pump

3. Product Features 3. Product Features -- Indoor appearance of installed unit

Modern, stylish indoor appearance

Suitable for high-end residential and hotel applications

Blue light LED temperature display

High quality ABS plastic frame with laminate panel overlay

Brand logos reverse printed on laminate overlay for elegant brand presentation

8

Page 9: Double Duct Interior Mount Heat Pump

3. Product Features 3. Product Features -- Outdoor appearance of installed unit

Patented flexible external grilles

UV resistant

Constructed of EPDM

Designed for easy installation on outer building

wall from inside the heated or cooled space.

Discreet outdoor appearance

Limited modification to outer building wall

Suitable for residential applications with

building wall restrictions, including hotels,

historical structures and government housing

9

Page 10: Double Duct Interior Mount Heat Pump

Discreet and Elegant Installations

The PTTW through the Wall unit is unique as a room air conditioner, as it designed to operate without an outdoor unit.

More and more countries now apply strict rules that forbid outdoor installation of air conditioners, in order to preserve the aesthetic properties of historical buildings. The PTTW is a revolutionary and innovative solution to this challenge.

The picture on the left shows the minimal effect of a PTTW installation on the outer appearance of a building, in contrast to standard split and window unit installations.

PTTW-10-EC installation

Window type installation Split type installation

3. Product Features 3. Product Features –– Heat pump and air conditioner

10

Page 11: Double Duct Interior Mount Heat Pump

The ease of assembly will reduce the overall time of installation by up to 70%.

There are no refrigerant line sets required. No inspection will be required. The Monobloc unit is supplied with a 230v wall plug

and is virtually “hang, plug, and play.” The Monobloc unit can be installed without ever living

the indoors - ideal for high rise apartments, condominiums, office buildings and alike.

3. Product Features 3. Product Features –– Easy installationEasy installation

PTTW-10-EC installation: Inside unit only

Split type installation: Inside unit & Outside unit

Page 12: Double Duct Interior Mount Heat Pump

3. Product Features 3. Product Features -- Sound performance

Ground-breaking sound performance:

Sound attenuation device for reduced outdoor sound level - optional on all models

device placed in air discharge hose during installation

reduction of 2.5 dBa to 3.5 dBa depending on unit size

and motor speed

Internal structure constructed from EPP

with excellent sound and vibration absorption properties

Innovative cross-flow ventilator fan design

for ultra-low indoor air flow sound

Compressor and internal parts noise acoustically

channeled to outdoor space via air intake and

discharge hoses

12

Page 13: Double Duct Interior Mount Heat Pump

3. Product Features 3. Product Features -- Cold weather operation

Cold-weather heating operation

PTTW-10-EC includes:

Hot-gas bypass using electronic expansion valve (EEV) for improved heating performance during defrost cycle

Standard 2 x 3,500 BTU/hr PTC electrical heaters mounted on the unit

2-stage thermo-fuse / thermistor cut-outs

13

Page 14: Double Duct Interior Mount Heat Pump

3. Product Features 3. Product Features -- Tropical T3 operation

Tropical T3 conditions cooling operation

Effective cooling performance in T3 tropical ambient conditions

Refrigerant system and components designed to withstand sustained

cooling operation up to 125.6°F ambient temperatures .

14

Page 15: Double Duct Interior Mount Heat Pump

PTTW COP Curve

0

0.5

1

1.5

2

2.5

3

3.5

5°F 14°F 23°F 32°F 45°F

Temperature (°F)

CO

P (B

tu/B

tu)

PTTW-10-EC

3. Product Features 3. Product Features –– Energy Performance

15

Cold weather heating operation

Effective heating performance in cold weather conditions

Page 16: Double Duct Interior Mount Heat Pump

3. Product Features 3. Product Features –– Product comparison

Product comparison:

PTTW-10-EC has high

energy efficiency of ratio (EER)

and high coefficient of

performance (COP), comparing

to other products with relative

cooling and heating capacities.

EER Performance Comparison

8

8.5

9

9.5

10

10.5

11

11.5

PTTW-10-EC PTAC Window Unit Split System

Relative Products

EE

R (B

tu/B

tu)

COP Performance Comparison

22.22.42.62.8

33.23.43.63.8

PTTW-10-EC PTAC Window Unit Split System

Relative Products

CO

P (B

tu/W

)

16

Page 17: Double Duct Interior Mount Heat Pump

3. Product Features 3. Product Features -- Unit controllers

IR handset:

controls all key functions, incl. timer, sleep, set-

temperature and fan speed

IR handset standard on all models

handset storage drawer standard on selected models

Onboard controller:

controls all key functions, incl. timer, sleep, set-temperature and fan speed

located on the top-right of the machine

standard on selected models

17

Page 18: Double Duct Interior Mount Heat Pump

3. Product Features 3. Product Features -- Indoor air quality

Indoor air quality filtration

nylon net filter (0.12” thickness) standard on all models

activated carbon and photocatalytic filters available as options (standard on selected models)

2-step removal and maintenance lift filter and air inlet grille

rotate plastic clips to remove filtersfor cleaning

Activated carbon filter

Photocatalytic filter

STEP 1 STEP 2

Activated carbon filter

high efficiency ventilation

effective on particulate matter >0.005 microns

Photocatalytic filter

eliminates harmful gases

sterilization rate of >99% vs. airborne bacteria

18

Page 19: Double Duct Interior Mount Heat Pump

3. Product Features 3. Product Features -- Fresh air intake system

Solution 1: Fresh air intake via building leakage - standard

utilizes slide gate to create negative air pressure differential which sucks fresh

air into the room

no extra installation of components required

Solution 2: Direct fresh air intake - optional

1.97” diameter hole in unit casing for fresh air intake direct from outdoors

with pre-installed nylon net filter

Fresh air volume up to 29.2 CFM at high speed

19

Page 20: Double Duct Interior Mount Heat Pump

3. Product Features 3. Product Features -- Condensate drainageFlexible drainage solutions 2 drainage connection points (each 0.74” dia.): 1 for outdoor drainage, 1 for indoor drainage

7.87’ drainage hose and connector as standard on all models

mini-condensate centrifugal pump available

REVERSE VIEW DRAINAGE POSITIONS: INDOOR 1 / OUTDOOR 2

Mini-condensate centrifugal pump

maximum discharge head of 16.4’

maximum flow rate of 132 gal/h

120 - 230V / 60 Hz models available

20

1

2

Page 21: Double Duct Interior Mount Heat Pump

3. Product Features 3. Product Features -- BMS solution

BMS solution

1 data logger per 200 unit sub-network

Max. 2 data-loggers per computer

Data-logger to unit connection using RJ45 telephone wire

Data-logger to PC connection using USB port

MODBUS communication protocol

Local PC software control program

Control full functionality of unit

Program runs on Windows 98/NT/XP/Vista

Suitable for small to medium size hotels

Software screenshots

BMS data logger

21

Page 22: Double Duct Interior Mount Heat Pump

3. Product Features 3. Product Features -- Front panel options

Wide range of standard panel colors

Customized panel designs

22

Page 23: Double Duct Interior Mount Heat Pump

4. Dimensional Drawings4. Dimensional Drawings

Note: Air inlet hose diameter Φ6.3”Air outlet hose diameter Φ5.91”

23

Page 24: Double Duct Interior Mount Heat Pump

THANK YOU FOR YOUR KIND ATTENTION AND INTEREST!THANK YOU FOR YOUR KIND ATTENTION AND INTEREST!

Headquarters, Hong KongOffice 6, 9/F, Block A, New Trade Plaza, 6 On Ping Street, Shatin, N.T., Hong KongTel. +852 2648 8887 Fax. +852 2636 6608 E-mail: [email protected]: www.sonkor.com

Branch Office, SpainC/Actriz Margarita Lozano 5, 2 5D - 30100 – Murcia, SpainTel. +34 687207815 E-mail: [email protected]

Branch Office, ChinaJinxiu 19-305, Lucheng, Wenzhou, ChinaTel. +86 577 8831 1691 Fax. +86 577 8831 1691 E-mail: [email protected]

Branch Office, North American Distribution Partner230 Dalfaber Lane, Springboro, Ohio 45066 USATel. +1 937 838 0019 Fax. +1 707 929 2588 E-mail: [email protected]