Top Banner
The Taco Hot-Link ® System (HLS-1) for domestic hot water recirculation reduces the time it takes for hot water comfort to reach showers and faucets. The Hot-Link System can save an average family up to 12,000 gallons of water per year and it’s easy to retrofit to an existing plumbing system. Domestic Hot Water Recirculation System ©Taco Catalog #100-93 Effective Date: 07/17/14 Supersedes: New Printed in USA Water Circulation Pumps & Circulators Exclusive clean in place undersink valve design
4

Domestic Hot Water Recirculation System - The Home … · Domestic Hot Water Recirculation System ... 07/17/14 Supersedes: New Printed in USA Water Circulation ... Hot-Link® System

May 21, 2018

Download

Documents

vudung
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Domestic Hot Water Recirculation System - The Home … · Domestic Hot Water Recirculation System ... 07/17/14 Supersedes: New Printed in USA Water Circulation ... Hot-Link® System

The Taco Hot-Link® System (HLS-1) for domestic hot water recirculation reduces the time it takes for hot water comfort to reach showers and faucets. The Hot-Link System can save an average family up to 12,000 gallons of water per year and it’s easy to retrofit to an existing plumbing system.

Domestic Hot WaterRecirculation System

©Taco Catalog #100-93 Effective Date: 07/17/14Supersedes: New Printed in USA

Water CirculationPumps & Circulators

Exclusive clean in place undersink valve design

Page 2: Domestic Hot Water Recirculation System - The Home … · Domestic Hot Water Recirculation System ... 07/17/14 Supersedes: New Printed in USA Water Circulation ... Hot-Link® System

LEFT: No under-sink electricity needed. The Hot-Link Pump is mounted at the water heater.

No wiring

Hot-Link®CartridgeCirculator

Hot-Link®Valve

delivers instant hot water using existing plumbing system!

Features:• Exclusive clean in place undersink valve design - Extends valve life - Reduces customer calls to replace “plugged” valves• Creates a domestic hot water recirculation system without dedicated return loop piping• Easy to retrofit to existing plumbing system• Conserves water by greatly reducing the time it takes to get hot water• Analog pump timer allows you to set the system to work during peak hours or to work continuously• Includes Hot-Link® System Cartridge Circulator, a Hot-Link bypass valve and flex hoses• 3 Year Warranty

Features

ToWaterHeater

From Water

Heater

Hot-Link Valve Closed Hot-Link Valve Open

Page 3: Domestic Hot Water Recirculation System - The Home … · Domestic Hot Water Recirculation System ... 07/17/14 Supersedes: New Printed in USA Water Circulation ... Hot-Link® System

CITY WATER SUPPLY COLD WATER LINE

HOT WATER LINE

Hot

Shut-O�Valve

Shut-O�Valve

The Best Locationis furthest �xturefrom Hot Water Heater

Optional AdditionalHot-Link® Valve Locations

(2) New 1/2”x1/2”Taco® supplied �ex lines(female to female)

Use (2) existing 3/8” x 1/2”female to female �ex lines

Hot-Link® includes (2)plastic wall anchors& screws

Cold

1/2” 1/2”

WaterHeater

Hot-Link®CartridgeCirculator

A Typical Installationwith a Mixing Valve

ColdInlet

HOT COLD

Hot Cold

HOT COLD

Save Energy, Water and Time!Link up to instant hot water comfort!

Installation is a snap. Uses existing plumbing.

Typical Hot-Link® Schematic

Hot water without the waste!The Taco Hot-Link® System for domestic hot water recirculation reduces the time it takes for hot water comfort to reach showers and faucets by recirculating “cooled” water back to the water heater; hot water lines remain hot. The Hot-Link® System can save an average family up to 12,000 gallons per year — water that normally goes down the drain while waiting for hot water.

How the Hot-Link System works.A quiet and efficient Hot-Link circulator is installed at the water heater and a Hot-Link bypass valve is easily installed at the faucet furthest away from the hot water heater. The thermal disk technology tells the Hot-Link bypass valve what to do. No under sink electricity is needed.

Hot-Link System is easy to install.The Hot-Link System circulator is installed at the water heater. Simply plug the 6’ power cord into any standard

120V electrical outlet; no electrician required. Everything needed to install and operate the Hot-Link System is included in the box. Simply set the Hot-Link circulator timer to work during peak hours or to work continuously.

Benefits of the Hot-Link System.Saves energy, water and time while providing instant hot water comfort. What’s more, it’s made by Taco, known by plumbing professionals as a world leader in high quality hydronic components since 1920.

Page 4: Domestic Hot Water Recirculation System - The Home … · Domestic Hot Water Recirculation System ... 07/17/14 Supersedes: New Printed in USA Water Circulation ... Hot-Link® System

HLS-1 Includes: Hot-Link Valve

Hot-Link Circulator

(2) Braided Flex Hoses

3/4” Bronze Union

Materials of Construction— Pump & Union Casting (Volute) ...................Stainless Steel Stator Housing......................Steel Cartridge ..................................Stainless Steel Impeller .....................................Noryl Shaft ............................................Ceramic Bearings ....................................Carbon O-Ring ........................................EPDM Union ..........................................Bronze

Materials of Construction— Hot-Link Valve Body ............................................Nylon Thermal Disk Actuator .....Bi-Metal O-Ring Seals ...........................EPDM Integral Flow Check (IFC®): Body, Plunger ...............Acetal O-Rings ............................EPDM Screen ........................................304 SS Stem ............................................Nylon Actuator Cartridge .............Stainless Steel Braided Flex Hoses .............Stainless Steel

Model Volts Hz Ph Amps RPM HP

Hot-Link Circulator 115 60 1 .52 3250 1/40

Motor Type Permanent Split CapacitorImpedance Protected

Electrical Data

ConnectionA B C D Ship Wt.

in. mm in. mm in. mm in. mm Lbs. Kg

1/2” MNPT 4 102 4-7/16 87 1-3/4 41 2-1/2 64 0.37 0.17

Dimensions & Weights:Hot-Link Valve

A B C D E F Ship Wt.

in. mm in. mm in. mm in. mm in. mm in. mm Lbs. Kg

7-1/4 184 1-15/16 49 2 51 3-1/16 78 5-1/4 134 3-5/16 84 7.0 3.2

Hot-Link Circulator

Taco Inc., 1160 Cranston Street, Cranston, RI 02920 / (401) 942-8000 / Fax (401) 942-2360 Taco (Canada) Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8 / (905) 564-9422 / Fax (905) 564-9436

www.taco-hvac.com

Submittal Data # 101-148 Effective: 07/17/14Supersedes: New Submittal Data Information

Hot-Link® System (For Domestic Hot Water Recirculation)

A C

B

MINIMUM AREAREQUIRED TOMOVE STEM

D

Certifications & Listings

FOR INDOOR USE ONLY

D

E

C

A

F

B