apartments
Feb 08, 2016
apartments
And it all started out so well!
The window has always been an important architectural element, adding balance and elegance. The balcony, however was just treated as a decorative feature.
Things started to go wrong when we tried to turn the balcony into a living area. Typically, it just ended up being used as a storage space which cut out the light and spoilt the facade.
You only have to look upwards to see cluttered balconies (bikes, boxes, chairs..) to see that they are not an attractive nor an elegant idea.
The balcony had to bereinvented!
Imagine.... you are enjoying a meal and you want to take advantage of the great weather.
Just slide one panel, two panels,...
....and, by simply sliding all the panels, you go from inside to outside.
loungekitchen
MORE THAN A WINDOW, LUMICENE IS A LIVING AREA
Unlike a standard balcony or terrace, LUMICENE is an inherent part of your living area. It extends the apartment by integrating it with the living area.The apartment becomes centralised around the LUMICENE which is not only an inside/outside interface but also links the kitchen, hall and living room. In this way, LUMICENE provides structure and flexibility to the whole living area.
Neither a bow-window, veranda nor terrace, LUMICENE is a cir-cular balcony area, redefining the link between the inside and the outside.
ADVANTAGES 7.
With LUMICENE, you are not simply inside or outside, but are able to switch between both, giving great flexibility depending on the light and weather conditions.
halfway outsideinside
ADVANTAGES 8.
Revolutionary
IN WINTER
IN SUMMER
PROTECTION FROM THE SUN
Based on «green» principles and sustainable development, LUMICENE is the only bioclimatic structure of its type on the market today. The different positions optimise the suns warmth and our comfort.
By optimising the buildings’ thermal inertia and with dynamic ventilation, LUMICENE helps create a «low energy home».
LUMICENE absorbs the suns energy all day, warming the room by the glass-house effect.
The panels are on the inside. The glass surfaces are then in the shade to stop over-heating.
By using the optional external shutters the thermal comfort is further improved.
morning
noon
evening
morning
noon
evening
Warm in winter
In the shade in summer
morning
noon
evening
morning
noon
evening
Warm in winter
In the shade in summer
morning
noon
evening
shutters Optional protection from sun
ADVANTAGES 9.
Bioclimatic
A true bioclimatic design must manage the effect of the sun as well as that of the wind.
This is managed by by the sliding panels which provide protection from any direction.
Wind Protection
Panoramic vision, light and quality space.Three crucial qualities to interest potential buyers.
with balcony
with LUMICENE
Panoramic
AVANTAGES 10.10.ADVANTAGES
When you are inside, LUMICENE increases the useful interior area and when you are outside, it increases the size of the balcony.
Either way, LUMICENE provides more useful space and is self-financing thanks to the extra saleable area.
50 m2 saleable
6m2 of balcony
56 m2 saleable
12m2 of balcony
= +
ADVANTAGES 11.
Autofinancing
AccessibilityStricter building regulations demand improved access and facilities for the disabled. With LUMICENE there are no gaps or steps. The increased light and access to the panoramic view can be fully appreciated.
The pictures below show comparisons between a LUMICENE and a standard balcony. The accessibility impact is immediately obvious.
Both inside and outside surfaces can easily be cleaned - in total security. Just slide the panels to access both surfaces.
User manuals are not required as the operation isintuitive. Open a lock at each end and the sliding panels can be freely positio-ned.
12.12.ADVANTAGES
Easy to maintain
Practical
LUMICENE is the result of succesful alliance between an innovative company and an industrial giant. The LUMICENE company and the St Gobain Group are linked through its subsidiary Sovedys by an exclusive licence.
LUMICENE is built integrally by Sovedys and the Group provides a full 10 year building warranty.
LUMICENE is a room in its own right (typically 12m2) and is usually used as a dining area.
The various LUMICENE diameters allow it to be used for other things such as larger rooms, pools, Jacuzzis or rest rooms in retirement homes.
model 3000
6m2
model 3500
model 5000
model 4000
model 6000
9m2
19,5m2
11,5m2
27m2
ADVANTAGES 13.13.
Industrial
Adaptable
VERTICAL BLINDS
Vertical blinds are particularly well suited to LUMICENE as they provide privacy and also protection from the sun.
Available as on option.Wide choice of materials and colours.
CURTAINS
LUMICENE is provided with curtain runners as standard. All types of curtains can be used for privacy and protection from the sun.
ADVANTAGES 14.
Privacy
MOTORISED CURVED BLINDS
Thanks to a built in storage space and a curved runner, the blind follows the LUMICENE shape.
Single or volume orders accepted.Large choice of sizes and materials.
ACCORDION DESIGN
The panels slide on curved rails and fold up like an accordion.
Wood or aluminium.
MOTORISED SHUTTERS
The shutters slide on curved rails and roll up inside two storage colu-mns. The polyurethane-filled slats are available in RAL colours.
Additional information: www.lumicene.com
ADVANTAGES 15.
Solar Protection
To learn more about the revolution which will transform your way ofliving, please consult our website
www.lumicene.com
17.
Le Palais Raphaël Lattes - Port Ariane (34)
28 LUMICENE ø 4 M
ARCHITECT Philippe Monestier
DEVELOPER Ellul
www.lumicene.fr/palaisraphael.html
EXAMPLES 18.
Ideal TowerBlankenberge - Belgium
EXAMPLES
20 LUMICENE ø 3 M
ARCHITECT Restyling Groep
DEVELOPER Ideal Tower NV
www.lumicene.fr/idealtower.html
19.
L’AmirautéLe Mans (72)
18 LUMICENE ø 3 M
ARCHITECT Alain Juillard
DEVELOPER P2I
www.lumicene.fr/amiraute.html
EXAMPLES 20.
Le LemaniazEvian (74)
12 LUMICENE ø 4 M
ARCHITECT Gilles Dagnau
DEVELOPER Baillet Immobilier
www.lumicene.fr/lemaniaz.html
EXAMPLES 21.
Kérival Laval (53)
9 LUMICENE ø 3 M
ARCHITECT Archigne
DEVELOPER LHK
www.lumicene.fr/kerival.html
EXAMPLES 22.
Villa Margaux Les Sables d’Olonne (85)
32 LUMICENE ø 3-4 M
ARCHITECT Artha.
DEVELOPER BATI NANTES
www.lumicene.fr/villamargaux.html
EXAMPLES 23.
Résidence François Laurent PleinGent (Belgium)
4 LUMICENE ø 4 M
ARCHITECT Luc Vertongen
DEVELOPER ABS Bouwteam
www.lumicene.fr/laurentplein.html
EXAMPLES 24.
Les Glycines Lille (59)
2 LUMICENE ø 4 M
ARCHITECT Philippe Stekelerom
DEVELOPER Debbé
www.lumicene.fr/glycines.html
EXAMPLES 25.
Les Jardins d’Héloïse Issy-Les-Moulineaux (92)
3 LUMICENE ø 3 M
ARCHITECT Hormozi
DEVELOPER Annie Promotion
www.lumicene.fr/jardinsheloise.html
EXAMPLES 26.
Avant-Seine Mantes-La-Jolie (78)
20 LUMICENE ø 3 M
ARCHITECT Atrium Studio
DEVELOPER Hermitage
www.lumicene.fr/avantseine.html
EXAMPLES 27.
Technical Notes
28.TECHNICAL NOTES
LUMICENE has curved glass panels running on two circular, concentric rails, top and bottom - all independent of each other. The external rail also acts as a sill. The inside rail is completely recessed into the floor finish and the concrete base.The top rail is simply a guide - it does not support the weight of the panels which slide on the bottom rail. It does,however, support the false ceiling which is necessary for both aesthetic and constructional reasons.
All the aluminium profiles have been specifically engineered for LUMICENE.The circular top rail is manufactured using numeric process control, ensuring millimeter precision - an essential property for a smooth sliding action. A patented thermal barrier has been developed for the curved profile.
The St Gobain signature guarantees the high performance glass. This is 16mm, laminated, low emission, argon filled as standard.
Design and Materials
LUMICENE : AN INDUSTRIAL PRODUCT
top curved rail PVC/ALU
curved, laminated glass
concrete floor
external drain rail
recessedinside rail
plaster board ceiling
recessed lighting
aluminium thermalbreak profile
assembled on concrete base
29.TECHNICAL NOTES
Dimensions
30.TECHNICAL NOTES
Sectional View
Top curved rail in PVC/ALU (patented)
Curved BA 13 plaster board
31.TECHNICAL NOTES
LATERAL SEALS
The seal between the panels and the pillar extremity is provided by a triple barrier consisting of automotive type, deformable seals. The result is a very high quality air and water seal.
At the top and bottom of the panels, a block is linked to the locks, ensuring a perfect seal.(Exclusive to LUMICENE)
Seals
32.TECHNICAL NOTES
ø3000
ø3500
ø4000
ø5000
ø6000
Height 2250 mm or 2500 mm
Standard on request Standard Standard Standard
Floor Area 6m2 8,75 m2 11,5 m2 19,5 m2 27 m2
Glass Area 8,2 m2 10,3 m2 11,3 m2 14,3 m2 17,5 m2
Number of Panels 4 4 5 6 7
Weight (6/16/6) 432 kg 542 kg 575 kg 753 kg 921 kg
Weight (44-2/166) 474 kg not available 680 kg 861 kg 1054 kg
Characteristics of the 6/16/6 Eko Plus Glass
U 1,5 W/(m2.K)
g iso 9050 M1 0,64 W(m2.K)
Kn 1,8 W(m2.K)
Glass Sound Reduction Index 44 2/16/6
RW 40 dB
LUMICENE has been successfully tested against strict European Standards.The approvals are available on the www.lumicene.com web site.
Characteristics
33.TECHNICAL NOTES
Method 1 : Prefabricated concrete beam
Installation
34.INSTALLATION
All the configurations below use the same method : a prefabricated concrete beam. The following pages describe the advantages.
Flush with the building to meet regulations or protruding to improve the view.
Prefabricated concrete beam
35.INSTALLATION
36.INSTALLATION
Cross-section
1 For ceiling heights of 250cm, the 225cm height LUMICENE is used. This choice is mainly aesthetic as the LUMICENE area is then clearly defined independently.
2 Using the 225cm height LUMICENE allows a lintel to be used which is normally necessary for structural reasons. A gap of 10cm is usually left between the underside of the lintel and the LUMICENE, to allow for a false ceiling and constructional tolerances.
3 The top rail is never fixed directly to the building structure. The use of a prefabricated, curved beam is strongly recommended as this guarantees a quality assembly and allows for any building imprecision.
4 Using a false ceiling complies with fire regulations concerning transmission between floors.
5 LUMICENE requires a concrete floor. The bottom rail is mounted on the rough concrete base. The rails are fitted using adjustable screw-jacks providing millimetre-height precision. Once the floor finish has been added, the rail is perfectly flush with the floor.
6 LUMICENE is an internal space. Inter-level insulation is therefore not necessary. The false ceiling only requires insulation if on the top floor. Prefabricated beams with a thermal bridge are available on request.
7 A range of standard safety rails have been designed for LUMICENE.
8The inside is finished with a curved plaster-board panel which fits into a slot in the top rail.
Prefabricated concrete beam
37.INSTALLATION
OUTSIDE LOWER RAIL
The bottom outside rail is of a conventional design. It serves as a drain and also compensates for concrete thickness. It has integrated adjustable screw-jacks and an external sealing strip.
OUTSIDE TOP RAIL
The outside top rail assembly is manufactured from solid PVC and curved aluminium,using numeric control techniques. A curtain rail is incorporated. The mounting method provides full three dimensional adjustments.
39.INSTALLATION
INSIDE LOWER RAIL
The bottom rail has been designed to be integrated into the finished floor. It is mounted on an adjustable height plate incorporating a silent block to provide an acoustic bridge when the concrete floor is laid.
INSIDE TOP RAIL
The top inside rail is of the same design as the top outside rail. It is fixed by an adjustable suspension system and has a slot for the curved plaster board panel.
Standard beam with or without overhang
MISE EN ŒUVRE 41.INSTALLATION 41.
Method 2:Between two concrete floors
Installation
42.INSTALLATION
This method does not use a prefabricated beam but is simply installed between floors, either using a balcony extension or within the building volume.
Flush with the building to meet regulations or protruding to improve the view.
Between two concrete floors
43.INSTALLATION
44.INSTALLATION
Cross-section
1 For ceiling heights of 250cm, the 225cm height LUMICENE is used.This choice is mainly aesthetic as the LUMICENE area is then clearly defined independently.
2 Using the 225cm height LUMICENE allows a lintel to be used which is normally necessary for structural reasons. A gap of 10cm is usually left between the underside of the lintel and the LUMICENE, to allow for a false ceiling and constructional tolerances.
3 The false ceiling space can be used to align the terrace with the floor on the last level to allow access by the disabled.
4 The LUMICENE can be positioned to best complement the interior design.
5 LUMICENE requires a concrete floor. The bottom rail is mounted on the rough concrete base. The rails are fitted using adjustable screw-jacks providing millimetre-height precision. Once the floor finish has been added, the rail is perfectly flush with the floor.
6 LUMICENE is an internal space. Inter-level insulation is therefore not necessary. The false ceiling only requires insulation if on the top floor
7 The inside is finished with a curved plaster-board panel which fits into a slot in the top rail.
Between two concrete floors
45.INSTALLATION
Download LUMICENE leaflet in 3D in .dwg format
standards approval report
complete assembly instructions
LUMICENE price list
LUMICENE photos
On www.lumicene.com
ADVANTAGES ............................................................................................. p 7 Revolutionary ....................................................................................... p 8 Bioclimatic ........................................................................................... p 9 Panoramic .......................................................................................... p 10 Wind protection .................................................................................. p 10 Self-financing & Accessibility ............................................................ p 11 Practical and Easy to Maintain .......................................................... p 12 Adaptable & Industrial ....................................................................... p 13 Privacy ............................................................................................... p 14 Solar protection .................................................................................. p 15
EXAMPLES ............................................................................................... p 17 Le Palais Raphaël .............................................................................. p 18 Ideal Tower ......................................................................................... p 19 L’Amirauté .......................................................................................... p 20 Le Lemaniaz ....................................................................................... p 21 Kérival ................................................................................................ p 22 Villa Margaux ..................................................................................... p 23 Le Laurent Plein ................................................................................. p 24 Les Glycines ....................................................................................... p 25 Les Jardins d’Héloïse .......................................................................... p 26 Avant-Seine ....................................................................................... p 27
TECNICAL NOTES ..................................................................................... p 28 Structure & Materials ......................................................................... p 29 Dimensions ........................................................................................ p 30 Sectional view .................................................................................... p 31 Seals .................................................................................................. p 32 Characteristics .................................................................................. p 33
INSTALLATION .......................................................................................... p 34 Prefabricated concrete beam ........................................................p 35-41 Between two floors ........................................................................p 42-45
TABLE DES MATIÈRES 47.
Review many examples on our websitewww.lumicene.com
LUMICENE is also used in houses
the balcony had to bereinvented!
21c rue des Lices F-53000 LAVALT +33 (0)2 43 56 60 60F +33 (0)2 43 49 07 89
Laure
nt
Salv
aire Invente
ur. B
revets
fra
nçais
et
euro
péens.
Marq
ue D
ép
osée.
Dro
its d
’exp
loitation e
xclu
sif
s S
oved
ys/S
t G
ob
ain
Gla
ss
20
08
- C
réd
its P
hoto
s : S
tud
io A
rka .
Desig
n: