Release Notes
EMC Storage Resource Management SuiteRelease number 3.0
Release NotesP/N 302-000-508REV 02January 03, 2014
These release notes contain supplemental information about EMC
Storage ResourceManagement Suite release 3.0. Topics include:u
Revision
history.........................................................................................................
2u Product
description....................................................................................................2u
New features and
changes.........................................................................................
2u Known problems and
limitations................................................................................5u
Installation..............................................................................................................
20u Environment and system
requirements....................................................................
20u Technical
notes........................................................................................................20u
Troubleshooting and getting
help.............................................................................22u
Documentation........................................................................................................
22
-
Revision historyThis table records the revisions made to this
document.Revision Date Description
- - -01 December 20, 2013 GA release of the product.02 January
03, 2014 Post-GA update of Known problems and
limitations on page 5.
Product descriptionEMC Storage Resource Management Suite
provides comprehensive monitoring,reporting, and analysis for
heterogeneous block, file, and virtualized storageenvironments. It
enables you to visualize applications to storage dependencies,
monitoranalyze configurations and capacity growth, as well as
optimize your environment toimprove return on
investment.Virtualization enables businesses of all sizes to
simplify management, control costs andguarantee uptime. However,
virtualized environments also add layers of complexity to theIT
infrastructure, that reduce visibility and can complicate the
management of storageresources. Storage Resource Management Suite
addresses these layers-simply-byproviding visibility into the
physical and virtual relationships to ensure consistent
servicelevels. As you build out your cloud infrastructure, SRM
Suite helps you ensure storageservice levels while optimizing IT
resources both key attributes of successful clouddeployments.
New features and changesEMC Storage Resource Management Suite,
release 3.0 includes consolidates Watch4netwith storage related
SolutionPacks, ProSphere topology and capacity metrics, and
thecompliance features of Storage Configuration Advisor into one
product with a single userinterface, installation, and discovery
process.EMC Storage Resource Management Suite (SRM Suite) provides
comprehensivemonitoring, reporting, and analysis for heterogeneous
block, file, and virtualized storageenvironments. It enables you to
visualize applications to storage dependencies, monitorand analyze
configurations and capacity growth, as well as optimize your
environment toimprove return on investment.Virtualization enables
businesses of all sizes to simplify management, control costs
andguarantee uptime. However, virtualized environments also add
layers of complexity to theIT infrastructure, that reduce
visibility and can complicate the management of storageresources.
Storage Resource Management Suite addresses these layers simply
byproviding visibility into the physical and virtual relationships
to ensure consistent servicelevels. As you build out your cloud
infrastructure, SRM Suite helps you ensure storageservice levels
while optimizing IT resources - both key attributes of successful
clouddeployments.New features in SRM Suite coreThe SRM Suite
combines the three separate products from the previous
version(ProSphere, SCA, and Watch4net) into a single integrated
software stack that delivers allthe capability of the previous
version plus more. It provides configuration, capacity, and
Release Notes
2 EMC Storage Resource Management Suite 3.0 Release Notes
-
performance reporting, alerting, topology, and storage
compliance, in one product with asingle user interface,
installation, and discovery process:u Quick installation of the
product into Windows, Linux, and VMware environments.u Ability to
check for core component and SolutionPack updates, download them,
and
then notify you that they are available for installation.u
Windows host agent that collects data without requiring any
credentials on the host.u Host capacity utilization reporting that
allows the storage admin to see how existing
capacity is being utilized.u Consolidated capacity reporting
across the EMC VMAX and VNX arrays.u Accurate and flexible
reporting of capacity allocation to clusters.u Management of SLAs
and Chargeback reports in terms of FAST Policy or disk/array
characteristics.u A new use-case driven user interface.u
Performance monitoring and troubleshooting.u Topology maps,
end-to-end tabular views of the data.u Consolidated monitoring of
health, configuration, compliance breaches, and
threshold-based alerts.u Tabular summaries of information about
zonesets, zones, and zone members.u Global search across all
discovered configuration items.u A consolidated Alert console that
includes:
l Alerts for breaches of EMC's eLab Support Matrix and
configuration best practicesl EMC PowerPath health metricsl
Threshold alerts based on performance datal Health alerts collected
from Brocade switches, Cisco switches, VMware, and VNX
and VMAX arraysNew SolutionPacksSRM Suite includes these new
SolutionPacks:SolutionPackName
Description Available Reports- - -SolutionPack forIBM
SVC/V7000
The IBM System Storage SANVolume Controller (SVC)SolutionPack
for IBM SVC/V7000 isa member of the IBM Storwizefamily providing
storagevirtualization with a single point ofcontrol for storage
resources. Itenables users to generate both real-time and
historical reports byaccessing the capacity andperformance details
to gain insightinto the management of theirunderlying Storwize
storageenvironment.
SolutionPack forEMC RecoverPoint
The SolutionPack for EMCRecoverPoint enables users togenerate
both real-time and
l RecoverPoint Summaryl Traffic Metrics
Release Notes
New features and changes 3
-
SolutionPackName
Description Available Reports- - -
historical performance reports asspecified for the data
replicationfrom any of the supported SAN-based arrays to any other
SAN-based arrays. The summary reportsfor key components such as
EMCRecoverPoint Appliance (RPA),Clusters, Consistency GroupMetrics,
and so on, and I/Othroughput analysis for SAN systemtraffic provide
a deeperunderstanding of the overallreplication schemes in place
andthe policies that govern them.
SolutionPack
forStorageCompliance(EssentialarchitecturalSolutionPack)
The SolutionPack for StorageCompliance feature analyzes
theconfiguration changes in yourdatacenter for policy complianceand
detects breaches against thosepolicies.
l Manage Rules and Policiesl Breach Reportl Match to EMC Support
Matrix
SolutionPack forEMC Host Interface
The SolutionPack for EMC HostInterface discovers physical
servers.A global view of all hosts in a datacenter with a drill
down on hosttopology, capacity utilization andperformance
measurements onhosts. Reports host capacity bysummarizing storage
LUNs mappedon host file systems and provide adetailed report on
Storage Capacity.
Note
SolutionPack for EMC Host Interfacedoes not support PowerPath in
theSRM Suite 3.0 release. PowerPathdata is available through
agentlessdata collection only in SolutionPackfor Physical Hosts and
SolutionPackfor VMware vCenter.
l Host Enterprise DashboardHost Information and detailsFile
Systems, VolumeManagement summary reportLocal and Remote Disk
CapacityReportsService level for LUNs mapped tohost file
systemsPerformance metrics for hostdevices namely CPU,
Memory,Disks
SolutionPack forPhysical Hosts
The SolutionPack for Physical Hostsenables users to monitor
andgenerate both real-time andhistorical reports regarding
theperformance of physical hosts andto gain better insight
intoparameters such as capacity andutilization associated to
aninventory of File Systems, VolumeGroups and Disks (both local
andremote).
l Host Enterprise DashboardHost Information and detailsFile
Systems, VolumeManagement summary reportLocal and Remote Disk
CapacityReportsService level for LUNs mapped tohost file
systems
Release Notes
4 EMC Storage Resource Management Suite 3.0 Release Notes
-
SolutionPackName
Description Available Reports- - -
Performance metrics for hostdevices namely CPU, Memory,Disks
SolutionPack forEMC DataProtection Advisor
The SolutionPack for EMC DataProtection Advisor (DPA) helps
youperform capacity management andchange management through
thesingle pane of the user interface. Italso generates alerts and
helps introubleshooting of your replicationand backup
environmentdiscovered and monitored throughDPA.
Replication:l RPO Compliancel Alertsl CapacityData Domainl
Configurationl Performancel Replication
Updated SolutionPacksThe list of updated SolutionPacks is as
follows. For details on the updates, see thespecific SolutionPack
Readme.u SolutionPack for Brocade FC Switchu SolutionPack for Cisco
MDS/Nexusu SolutionPack for EMC VPLEXu SolutionPack for Physical
Hostsu SolutionPack for VMware vCenteru SolutionPack for
VirtualWisdomu SolutionPack for EMC VMAXu SolutionPack for EMC VNXu
SolutionPack for Hitachi Device Manageru SolutionPack for NetApp
Filer now includes support for Cluster Mode (C-Mode).SolutionPacks
not supportedSRM Suite 3.0 does not support the SolutionPack for
ProSphere-SCA.
Known problems and limitationsThis topic lists the known issues
and limitations in each Storage Resource ManagementSuite component
first alphabetically by the component name, and then in
descendingorder of the issue number.
CQ/Issuenumber
Component Problem description Workaround /Resolution- - -
-651395 Alert Consolidation For Compliance breaches, the All
Alerts report does not display CreatedAt and Modified At
data.
Use the Operations > Compliance > Breachinstead.
Release Notes
Known problems and limitations 5
-
CQ/Issuenumber
Component Problem description Workaround /Resolution- - -
-651349 Alert Consolidation If the APG webservice is not
reachable,
File not found Exceptionentry is found in the EPM log.
Ignore the exception. It is removed on successfulconnection to
the APG webservice.
650764 Alert Consolidation All Alerts report does not show
alertsreceived from external sources if thesystem time of the
source is ahead(later than) the SRM Suite host.
Ensure that the system time of alert sources andSRM Suite are in
sync at all times in order to viewalerts in the All Alerts report
as soon as they areprocessed.The delayed alerts appear in the All
Alerts report aswhen the suite host timestamp crosses the
systemtimestamp of the alert source.
650225 Alert Consolidation During SolutionPack for Brocade
FCSwitch installation entry of themandatory email address result
inemail notifications only for the CreditLoss alerts, and is
applicable to emailnotifications for alerts consolidated.
Disable the corresponding alert definition in theAlerting
Frontend.
650018 Alert Consolidation Alert consolidation continues to
workafter uninstallation of the followingSolutionPacks:l Brocade FC
Switchl Cisco MDS/Nexusl EMC VMAX
The "Infrastructure Preparation for Discovery andData
Collection" chapter in the EMC StorageResource Management Suite
Installation andConfiguration Guide describes the procedure
forenabling alert consolidation for each alert source.l For Brocade
and Cisco switches, apply the same
procedure used for enabling alert consolidationto disable SNMP
trap forwarding by logging intoeach switch.
l For VMAX, apply the same procedure used forenabling alert
consolidation to disable SNMPtrap forwarding by removing trap
recipient IPsfrom the daemon_options file in therespective
Solutions Enabler (SE).
612178 Alert Consolidation User Datagram Protocol (UDP) nature
ofSNMP traps for VMAX arrays fromSolutions Enabler, the suite fails
toreceive and display some alerts. If atrap is lost in the
networkcommunication, Solutions Enabler isnot aware of the loss and
cannotresend the lost information.
There is not workaround available.
611574 Browser support When using Internet Explorer (IE) 9
theissues are:l In the Login screen, Sign In is
disabled.l In Centralized Management, the
main view and the navigationpanel are blank.
l To enable Sign In in the Login screen, add theSRM Suite URL to
the IE Local Intranet zone.
l To view all Centralized Management features,either disable the
IE Pop-up Blocker, or add theSRM Suite URL to the Pop-up Blocker
exceptionlist.
Release Notes
6 EMC Storage Resource Management Suite 3.0 Release Notes
-
CQ/Issuenumber
Component Problem description Workaround /Resolution- - -
-602585 Browser support When using Internet Explorer 8 to
install a SolutionPack, the installermight fail to start.
Close the current selection and then select theSolutionPack
again.For more information, see Primus article emc324861.
602584 Browser support There are browser refresh issues
whenusing IE8.
There is no workaround available.
N/A Browser support(SolutionPack forStorageCompliance)
In IE 8, only Breach Report isaccessible under Operations
>Storage Compliance. The other twoadministrative options are
accessibleonly in IE versions 9 and 10:l Manage Rules &
Policies and all
associated policy administrationoptions
l Match to EMC Support Matrixadministration option
There is no workaround available.
612531 End-to-End reports Passive hosts are not reported in
theconnectivity and path details topologyreports for switches and
storagesystems.
Connectivity and path details for passive hosts arereported in
the context of the passive host itself.These reports can be opened
in Explore > PassiveHosts, or by searching for the passive
host.
612528 End-to-End reports When VM is deleted in Virtual
Centerand recreated on a different ESX server,it might be reported
in the topologymaps as related to both the old andnew ESX
servers.
Contact EMC Customer Support for a workaround todisassociate the
VM from the old ESX server.
612514 End-to-End reports Selection of a fabric or VSAN node
inthe map does not display any reports.
You can view reports for the fabric or VSAN byselecting or
searching for it in Explore > SANConnectivity > Fabric.
611981 Web GUI-Frontend Auto-suggest filter does not work
inAlerting, Events, Compliance, andOperations > Inventory >
StorageInventory > Connected LUNs.
There is no workaround available.
650976 Web GUI-Frontend When you export reports in PDF
formatfrom Explore > Hosts > , the suite does not includethe
topology map.
There is no workaround available.
611749 Web GUI-Frontend When a LUN (or any other component)is
remove from an array, it takestwenty-four hours to be excluded
fromthe global reports.
There is no workaround available.
N/A Global CapacityReporting
Certain cells in the report for Symmetrixor CLARiiON arrays are
empty ormissing data for the following reasons:l Discovery of the
arrays takes
longer than 15 minutes.
This is expected behavior. To enable efficient, error-free
discovery, ensure that you:l Restrict only one Symmetrix or
CLARiiON array to
each collector.
Release Notes
Known problems and limitations 7
-
CQ/Issuenumber
Component Problem description Workaround /Resolution- - - -
l Discovery stopped due to errors. l Check your logs to identify
the cause of anyerrors that are preventing successful discovery,and
correct them.
N/A Global CapacityReporting
Some configuration data for a LUN takeup to three collection
cycles to be set.
There is no workaround available, because this isthe expected
behavior for configuration data of aLUN, as in the case of the
following:l Flags, such as, Is Used, Is Pool Contributor,
and Is Pool Consumerl Attributes, such as, Purpose (Primary,
Local
Replica, Remote Replica, System Resource)l Attributes, such as,
Service Level, Storage
Group NameSRM Suite requires two collection cycles to
computeenterprise capacity metrics (for example, Used,Free,
Primary, Service Level Free) accurately. Inbetween collection
cycles, you can expect thecapacity values to fluctuate.
650102 SolutionPack forBrocade FC Switch
The report issues are:l The Throughput by Fabrics (/s)
report:l Should be renamed to
Throughput by Switch (/s).l Should include the unit of
throughput as million packetsper second (MPPS).
l Displays the throughput datafor only one switch and not
all.
l The All, None, and Autooptions cannot be applied.
l The report description isrepeated twice.
l The Throughput by Port (/s)report:l Does not include the
switches
for which the port data hasbeen generated.
l The legend descriptions are notcomplete.
l The All, None, and Autooptions cannot be applied.
l The report description isrepeated twice.
There is no workaround available.
Release Notes
8 EMC Storage Resource Management Suite 3.0 Release Notes
-
CQ/Issuenumber
Component Problem description Workaround /Resolution- - -
-649960 SolutionPack for
Brocade FC SwitchBrocade Access Gateway does notsupport the
capabilities (SNMP MIBs)of normal Brocade FC switches. Hence,the
SolutionPack does not collect andreport system performance
statisticsand FC port statistics for AccessGateways.
There is no workaround available.
612826 SolutionPack forBrocade FC Switch
Switch discovery fails to terminatewhen the seed file contains
invalidvalues.
Ensure that all the values in the seed file are valid the
collector group mentioned should be available,and the SNMP version
should be correct (v1, v2c,and v3).
612720 SolutionPack forBrocade FC Switch
Host names are not resolved correctlywhen zone names have more
than 3underscores, and there are digits justbefore the last
underscore.
There is no workaround available.
611966 SolutionPack forBrocade FC Switch
Although the path details showconnectivity, end to end topology
mapsare broken due to missing fabrics andswitches.A symptom of this
issue is that theSNMP Collector starts timing out insuccessive
collection cycles due tonetwork issues or unresponsiveswitches. The
Collector logs indicatethis behavior with a WARNINGstatement in the
format:WARNING -- [EST]--
PollingUnitTable$PollTableTask::catchIOException(): time out
afterretrieson agentHost=,Port=
1. Increase the timeout of switches using thedevice-discovery
web application.
2. Push the updated configuration to the Collector.
N/A SolutionPack forBrocade FC Switch
The Interfaces Utilization has nodata in the Interface Type and
Speed(Mbps) columns.
There is no workaround available.
649888 SolutionPack forCisco MDS/Nexus
The report issues are:l In the general VSANs report, the
Number of FC Ports and StaticPorts Configured have 0 as
thevalue. Also, the AverageUtilization (/s) column has novalue.
l In the Name Server Databasereport for individual switches,
theFabric Port column has no values.
There is no workaround available.
Release Notes
Known problems and limitations 9
-
CQ/Issuenumber
Component Problem description Workaround /Resolution- - - -
l In the VSANs report for individualVSANs, the Static
PortsConfigured table, the FC Idcolumn has no values.
N/A SolutionPack forEMC Data Domain
The Overview report has no data inthe Serial Number
andUncompressed Stored Datacolumns. In addition, the
performancecharts in the drill-down data are empty.
There is no workaround available.
651443 SolutionPack forEMC Host Interface
The default performance polling cyclefor SolutionPack for EMC
Host Interfaceis 5 minutes .
During SolutionPack installation or reconfigurationenable
15-minute (900 seconds) polling interval:1. Select Do you want to
configure advanced
settings.2. Click Install.
651260,650702
SolutionPack forEMC Host Interface
SolutionPack for EMC Host Interfacedoes not support EMC
PowerPath andVeritas Volume Manager:l If the SolutionPack for EMC
Host
Interface discovers a host on whichPowerPath is installed, there
is nodata in the Physical Hosts > HostInformation > Device
>PowerPath Reports for HealthSummary, Bus Metrics and
LUNMetrics.
l If SolutionPack for EMC HostInterface is installed on a host
withVeritas Volume Manager, incorrectdata is possible in the
ReportLibrary > EMC Host Interfacereports for Configured
andUnconfigured Disk Capacity, andreports that contain File
Systemand Volume Group information.
There is no workaround available.
649996 SolutionPack forEMC Host Interface
Within 5 to 6 hours, significant memoryleak was observed for
SolutionsEnabler.
During SolutionPack installation or reconfiguration:1. Select Do
you want to configure advanced
settings.2. Set Topology Polling Interval to 21600 (6
hours).651592 SolutionPack for
EMC VMAXThe bar chart in the Raw CapacityUsage for individual
arrays is absentbecause of incorrect reportconfiguration. The
report should have
1. In the User Interface, click Edit Mode.2. Click on Report
Configuration, and make the
following changes:a. Set Default Duration to last 1 week.
Release Notes
10 EMC Storage Resource Management Suite 3.0 Release Notes
-
CQ/Issuenumber
Component Problem description Workaround /Resolution- - - -
time settings of Last 1 Week:average on 1 hour.
b. Set Sampling Period to 1 hour.c. Set Sampling Type to
average.
3. Click Save.4. Click Browse Mode and return to the report
to
view the bar chart.651270 SolutionPack for
EMC VMAXThe SolutionPack reports include allVMAX arrays in the
environment,including empty entries for VMAXarrays that are not
configured forcollection of topology data.
There is no workaround available. In the reports,ignore all VMAX
arrays that have not been configuredfor topology data
collection.
612796 SolutionPack forEMC VMAX
Masking View Summary report doesnot display any value for
Devicecount.
There is no workaround available.
612681 SolutionPack forEMC VMAX
Incorrect Pool Subscribed capacityvalues reported for VMAX
arrays. Theaffected report is Explore > Storage >Storage /
Storage Systems - Block.
Note
Reconfiguration of the SolutionPack overwrites thevhf-vmax3.xml
change described here. Therefore,you must repeat this procedure
every time theSolutionPack for EMC VMAX is reconfigured.On each
VMAX Collector instance in yourenvironment, perform this
procedure:1. Click Administration > Centralized
Management > Logical Overview >Collecting .
2. Click Variable-Handling-Filter::.Where, is the name of
theSolutionPack for EMC VMAX instance.
3. Under Properties, expand Configuration files.4. Type
vhf-vmax3.xml in the Search filter.5. When conf/vhf-vmax3.xml,
appears in the
search result, click next to the file.6. In line 19 of
vhf-vmax3.xml, delete the XML:
(name=='SubscribedCapacity' |name=='OversubscribedCapacity'
|name=='RemoveMeZero') &pooltype=='Thin Pool'
7. In the same location, insert the XML:(name=='SubscribedCa
Release Notes
Known problems and limitations 11
-
CQ/Issuenumber
Component Problem description Workaround /Resolution- - - -
pacity' |name=='OversubscribedCapacity' |name=='RemoveMeZero')
&parttype=='Storage Pool' &pooltype=='Thin Pool'
8. Under Service Status, click Stop, and thenStart.
612679 SolutionPack forEMC VMAX
The suite reports incorrect ConfiguredUsable Including RAID,
RAIDOverhead, and Unusable Capacityvalues for VMAX arrays.The
affected reports are:l Explore > Storage > Storage /
Storage Systems - Blockl EMC VMAX > Array Summary >
> Raw Capacity Usage
Note
Reconfiguration of the SolutionPack overwrites
thexmlcollector-vmax-topo.xml changedescribed here. Therefore, you
must repeat thisprocedure every time the SolutionPack for EMCVMAX
is reconfigured.On each VMAX Collector instance in yourenvironment,
perform this procedure:1. Click Administration > Centralized
Management > Logical Overview >Collecting .
2. Click XML-Collector::.Where, is the name of theSolutionPack
for EMC VMAX instance.
3. Under Properties, expand Configuration files.4. Type
vmax-topo in the Search filter.5. When conf/xmlcollector-vmax-
topo.xml, appears in the search result, click next to the
file.
6. Under the rawcap property, delete XMLmentioned in CQ612679:
xmlcollector-vmax-topo.xml file changes on page 20.
7. In the same location, insert the XML provided in CQ612679:
xmlcollector-vmax-topo.xml filechanges on page 20.
8. Under Service Status, click Stop, and thenStart.
612590 SolutionPack forEMC VMAX
The following issues are observed inChargeback reports:Total
Presented and Total UsedChargeback capacities for a Host/HyperVisor
do not include anySnapshot capacities(VDEVs) of theprimary LUNS.
The affected reports are:
There is no workaround available.
Release Notes
12 EMC Storage Resource Management Suite 3.0 Release Notes
-
CQ/Issuenumber
Component Problem description Workaround /Resolution- - - -
l Explore > Storage > Chargebackby Host/HyperVisor >
TotalUsed and Total Presented
l Explore > Storage > Chargebackby HyperVisor Cluster >
TotalUsed and Total Presented
l Dashboard > Storage >Chargeback by Group > TotalUsed
and Total Presented
Local Replica Used capacity does notinclude any
Snapshotcapacities(VDEVs) of the primary LUNS.The affected reports
are:l Dashboard > Storage > Used
Capacity by Purpose > LocalReplica Used Capacity
l Explore > Storage System Block> Local Replica Used
Capacity
610764 SolutionPack forEMC VMAX
Capacity numbers may fluctuate for alimited period during active
datacollection.
There is no workaround available.
N/A SolutionPack forEMC VMAX
Connectivity report for NPIV GatewaySwitch incorrectly includes
virtualconnectivity along with physicalconnectivity. Only physical
connectivityshould be used in this report.
There is no workaround available.
649279 SolutionPack forEMC VNX
Report Library > EMC VNX > TreeQuota reports are missing
from VNXFile.
There is no workaround available.
612779 SolutionPack forEMC VNX
The Usable Capacity by Pool > BlockPools report (VNX) does
not containdata in LUN Contributors,Consumers , and Disk
Contributorstables.
Use the Explore > Storage > Block Pools tablesinstead.
612651 SolutionPack forEMC VNX
When upgrading from EMC Watch4net6.2.4 to 6.3 in a
distributedenvironment, SEVERE errors appear forthe following files
in the SolutionPack:l pre-replica-chain.csvl usedby.csvl
poolraidluns.csv
There is no workaround available.
Release Notes
Known problems and limitations 13
-
CQ/Issuenumber
Component Problem description Workaround /Resolution- - -
-612413 SolutionPack for
EMC VNXIn Explore > Block Pools Global ,Snap Pools have no
pool consumers inthe Consumers column.
There is no workaround available.
612345 SolutionPack forEMC VNX
In the Storage Capacity Presentedto NAS Report report for
individualVNX arrays, the Free Capacity onUsed Disks(GB) column may
displaynegative values.
There is no workaround available.
612300 SolutionPack forEMC VNX
In the Usable Capacity by ServiceLevel report, the columns
remainempty when they should display thevalue 0.
There is no workaround available.
612219 SolutionPack forEMC VNX
Meta LUN performance charts do notcontain any data.
There is no workaround available.
612151 SolutionPack forEMC VNX
The tooltips in the Usable Capacityand Used by Purpose reports
(VNXand Enterprise) do not match the reportdata.
Ignore the tooltips. The report data is correct.
611697 SolutionPack forEMC VNX
The SolutionPack does not support ESXNFS datastores.
There is no workaround available.
610219 SolutionPack forEMC VNX
When a pool contains a list of LUN IDsthat collectively exceed
4096characters, the Pool Name does notappear in the Pool Summary
report.
1. Navigate to the #/opt/APG/bin/apg.properties.
2. Under the system property,
addrestricted.reader.line.size=32768.
3. Wait for 1 hour and then recheck the PoolSummary report for
the appearance of PoolName.
609662 SolutionPack forEMC VNX
The SolutionPack does not tag commonLUNs with all the storage
groups towhich the common LUNs are members.
There is no workaround available.
644238 SolutionPack for HP3PAR StoreServ
The capacity units for total, free,allocated and failed capacity
in HP3PAR StoreServ Solution pack do notmatch with those shown in
3PAR CLI.The Usable Capacity Report will showcapacity units in GB
instead of TB unit.
1. In the User Interface, click Edit Mode.2. Click Report
Details: Graph, and make the
following changes:3. Change the By Unit value from MB to GB.4.
Change To Unit to Auto.5. Click Save.6. Click on Browse Mode and
check the report.7. Repeat the steps 1 through 4 for Free
Capacity,
Allocated Capacity and Failed Capacity.N/A SolutionPack for
Microsoft Hyper-VOne volume report underAll Volumes >Volume
List displays the following
There is no workaround available.
Release Notes
14 EMC Storage Resource Management Suite 3.0 Release Notes
-
CQ/Issuenumber
Component Problem description Workaround /Resolution- - - -
text for the By File Type graph: Thisgraph doesn't
supportnegative values...
651414 SolutionPack forNetApp Filer
Report Library > NetApp Filer >Storage Systems Summary
> 7-Mode > FilerName > Details >Snapshots report does
not displayvolume details. Aggregate details mightincorrectly
include volume data.
There is no workaround available.
651331 SolutionPack forNetApp Filer
If a disk name is the same in multiplenodes of a cluster, the
Total Diskscolumn displays incorrect data in theReport Library >
NetApp Filer >Storage Systems Summary > C-Mode report.
1. Click Report Library > NetApp Filer > StorageSystems
Summary > C-Mode, and then clickEDIT MODE.
2. Expand the C-Mode report.3. Click the child Node C-Mode
Filer, and then
the arrow next to C-Mode Filer.4. In the NetApp Filer > >
C-Mode
Filer that opens, click Formula.5. Click
util.DistinctValueCountFormula , and
then Settings.6. In Expand on field for Value, type
device,part .7. Click Save and wait until the Save
Successful message appears.8. Click BROWSE MODE to return to the
normal
report view.651358 SolutionPack for
NetApp FilerThe Report Library > NetApp Filer >CPU
Utilization report shows the totalCPU busy time instead of the
averageCPU busy time.
1. Click Report Library > NetApp Filer > CPUUtilization ,
and then click EDIT MODE.
2. Click Filtering & Expansion .3. Click the filter
CpuBusyTotal.4. Click Edit, and type CpuBusyAvg.5. Click Save and
wait until the Save
Successful message appears.6. Click BROWSE MODE to return to the
normal
report view.651359 SolutionPack for
NetApp FilerIncorrect unit conversion results ininaccurate
values in the Saved Spacecolumn of the Report Library >NetApp
Filer > Capacity >Deduplication report.
1. Click Report Library > NetApp Filer > Capacity>
Deduplication.
2. Click Report Details: Table .3. Expand Value:Saved Space ,
and then expand
Value Settings.
Release Notes
Known problems and limitations 15
-
CQ/Issuenumber
Component Problem description Workaround /Resolution- - - -
4. In Scaling Mode > Unit, type TB.5. Click Save and wait
until the Save
Successful message appears.6. Click BROWSE MODE to return to the
normal
report view.651204 SolutionPack for
Physical HostsSolutionPack forEMC Host Interface
The suite reports inaccurate data for ahost configured for
discovery in bothSolutionPack for Physical Hosts andSolutionPack
for EMC Host Interface.
Configure the host for discovery only on oneSolutionPack, and
not both.
N/A SolutionPack forPhysical HostsSolutionPack forVMware
vCenter
The Inventory > List all servers > chart for CPU Usage (%)
hasno data.
There is no workaround available.
651142 SolutionPack forPhysical Hosts
In LUN Path Health and LUN Metricsreports for Windows hosts, a
fewdevices and LUNs might be duplicated.These reports might contain
containingpartial or empty data in a few columns.
There is no workaround available.
650667 SolutionPack forPhysical Hosts
The suite does not support PowerPathreports for HP-UX-11.23 due
tooperating system limitations.PowerPath reports and alerts
aresupported only for HP-UX 11.31.
There is no workaround available. The suite supportsPowerPath
reports in HP-UX 11.31 and later.
649903 SolutionPack forPhysical Hosts
Host data collection fetches partial CPUname on select Sun
Solaris hosts.
There is no workaround available.
649651 SolutionPack forPhysical Hosts
The WS-MAN (Web ServicesManagement) APIgetFCPTargetMapping
function returnsincorrect number of LUNs on Windows2003 and
2008.The problem is seen on problem isseen on old HBA models
QlogicQLA2340 and QLA2342. These arelegacy HBA IO cards that are
supportedonly on older servers running Windows2003 and Windows
2008.
Contact your EMC Customer Service Engineer toobtain the INQ
binary executable to fix this issue.
612657 SolutionPack forPhysical Hosts
Initial selection of the StorageConnectivity report for physical
hostsdoes not show any connections.
Click a different device in the map (for example, aswitch or
array), and then click the original hostagain.
611214 SolutionPack forPhysical Hosts
In LUN Path Health and LUN MetricReports for some hosts, a few
devicesor LUNs might be duplicated containingpartial or empty data
in a few columns.
Ignore the empty or partial data rows for duplicateddevices.
Release Notes
16 EMC Storage Resource Management Suite 3.0 Release Notes
-
CQ/Issuenumber
Component Problem description Workaround /Resolution- - - -N/A
SolutionPack for
Physical HostsThe Uptime column in the HostInformation report
has no data.
There is no workaround available.
651345,611302
SolutionPack forStorageCompliance
Solutions Enabler, HBA firmware andvendor details for ESX
servers are notavailable for compliance rules thatinvolve checks
related to multi-pathingsoftware. This information is currentlynot
part of the VMware discovery datacollection.
There is no workaround available.
651255 SolutionPack forStorageCompliance
Rules are not populated in the CreatePolicy > Rules when the
defaultpolicies are selected in the followingscenario:1. You select
a policy template when
creating a policy.2. Create a scope for the policy.3. Change the
policy template to
some other entry.The rules corresponding to thisnew selection
are not displayed.
1. Cancel the policy creation.2. Create a new policy.
650644 SolutionPack forStorageCompliance
Bulk matched items show up in thesame report view irrespective
of thepage number set.
Refresh the report view.
651266 SolutionPack forVMware vCenter
After discovering LUN and path relateddata (present in the
database and userinterface), if a LUN is removed fromhost, the LUN
and path data persist inthe database and user interface.
There is no workaround available.
650617 SolutionPack forVMware vCenter
In Report Library > VMware vCenter >Situations to Watch
> DiskBottleneck Analysis report, there isno data in the
following columns:l IOPSl Throughput/sl Queue Latencyl Total
Latency
There is no workaround available.
644756 SolutionPack forVMware vCenter
The query AvailablePerfMetricsdisplays no data for the
discoveredvCenter.
There is no workaround available.
644003 SolutionPack forVMware vCenter
Missing or stale data are displayed forVMware reports when
vCentercredentials expire.
The credentials used to discover a vCenter in vCentersolution
pack should be kept updated and current. Itis advisable to use
passwords which do not expire.
Release Notes
Known problems and limitations 17
-
CQ/Issuenumber
Component Problem description Workaround /Resolution- - -
-612776 SolutionPack for
VMware vCenterVirtual Applications report for VMs ismissing the
following metrics:l VCPUsl Memory sizel CPU Usagel %CPU
There is no workaround.
612419 SolutionPack forVMware vCenter
IP Network details are not available forHypervisor (ESX).
There is no workaround available.
612386 SolutionPack forVMware vCenter
On Windows Collectors, performancecollection does not occur
despiteselection of Collect PerformanceMetrics for PowerPath LUNs
duringSolutionPack.
Manually edit the value of thepowerPathPerformanceCollection
flag inthese files:l For Windows hosts
LunMappingDetection.ps1l For ESX-Windows hosts
ESXPowerPathPerformance.ps1
612332 SolutionPack forVMware vCenter
If ESX servers have vMotion that is notactivated, the IP address
is notavailable in Explore > Hosts >Hypervisor report. This
is because,typically, there are several IPs assignedto an ESX
server. Of these IPs, the suiteonly collects the property ip from
the IPthat is unique to vMotion.
There is no workaround available.
612328 SolutionPack forVMware vCenter
At times, Storage Connectivity >Connectivity reports for VMs
and ESXservers do not display any data forswitch port WWN data.
There is no workaround available.
611790 SolutionPack forVMware vCenter
The Path Details report for ESX serversand VMs do not contain
paths for NFSDatastores.
There is no workaround available.
610125 SolutionPack forVMware vCenter
Some capacity and configurationreports might report incorrect
datawhen different virtual machines areconfigured in VMware vCenter
with thesame display name.
There is no workaround available.
N/A SolutionPack forVMware vCenter
The Situations to Watch > VirtualMachines CPU Bottleneck
report hasno metric and CPU Ready By O.S (%)data.
There is no workaround available.
N/A SolutionPack forVMware vCenter
The Datacenters Summary > host >Hosts > > Virtual
Machines >Virtual Machines report has no data
There is no workaround available.
Release Notes
18 EMC Storage Resource Management Suite 3.0 Release Notes
-
CQ/Issuenumber
Component Problem description Workaround /Resolution- - - -
in a few columns, including StoragePath.
602586 SolutionPack forEMC Watch4netHealth
Installing theSolutionPack for EMCWatch4net Health using IE8
might fail ifit is the first SolutionPack to beinstalled.
Install a different SolutionPack first, then install
theSolutionPack for EMC Watch4net Health. For moreinformation, see
Primus article emc324861.
612841 Topology NAS Gateway topology maps do notshow complete
end-to-end path whengateway is not connected through anAG/NPV
switch.
Use the Path Details report to identify the backendarray.
However, there is no workaround available forthe absence of switch
data in the StorageConnectivity report.
612587 Topology Hosts can be seen under PassivelyDiscovered
Hosts. However, whenthese hosts are selected, the maps
areempty.
1. Navigate to Administration > CentralizedManagement >
Physical Overview > .
2. In the Services list, click Topology-Mapping-Service -
Default.
3. Click Restart.612584 Topology End-to-end topology maps
continue to
display paths that should not exist,such as when the associated
maskingrecord has been deleted.This issue occurs because the
deletionof masking is not propagated to thetopology service. Should
a physicalpath exist, the suite incorrectlydisplays the path as
connected.
There is no workaround available.
611966 Topology The Topology Map does not showcomplete
end-to-end path for hostsconnected to Symmetrix arrays
throughBrocade switches.
From the device discovery application, check if theswitch
discovery has failed due to SNMP timeout. Ifso, increase the
timeout and rediscover the switch.
611704 Topology Data collected from Collectors are notavailable
in topology maps. This issueoccurs because the Topology
MappingService fails to send data to theBackend after Generic-RSC
andGeneric-SNMP are configured on ascaled-out Collector before
deployingthe SolutionPack for Brocade FCSwitch, SolutionPack for
Cisco MDS/Nexus, and SolutionPack for EMC HostInterface.
Restart the Topology Mapping Service afterreconfiguring
Generic-RSC and Generic-SNMP:1. Navigate to Administration >
Centralized
Management > Physical Overview > .
2. In the Services list, click Topology-Mapping-Service -
Default.
3. Click Restart.
611071 Topology The end-to-end topology maps forCisco switches
are broken.
Use the maps for other connected devices, like hostsand arrays,
to view fabric and switch topology.
612754 vApp The single VM vApp is used for both All-In-One vApp
installations, as well aspre-configured SRM Suite 3.0 VMssuitable
for scaling out an existing SRM
After deployment of the single VM vApp (with anyrole other than
All-In-One vApp), but before startup:1. Log into VMware
vCenter.
Release Notes
Known problems and limitations 19
-
CQ/Issuenumber
Component Problem description Workaround /Resolution- - - -
Suite installation. When used as an All-In-One vApp, the VM is
configured withthe right parameters. However, whenused as any other
type of VM, the CPUcount is set to 2, which is too low forthe load
placed that will be placed onit.
2. If the vApp is already up, power off the vApp(after making
sure the first boot is complete).
3. Increase the CPU count for the VM from 2 to 4.4. Power on the
vApp.
InstallationThe Storage Resource Management Suite Installation
and Configuration Guide, availableon EMC Online Support at
https://support.emc.com, provides instructions forinstallation,
post-install configuration and supported upgrade paths.
Environment and system requirementsThe EMC Storage Resource
Management Suite Support Matrix, available on EMC OnlineSupport at
https://support.emc.com, provides details on system requirements, a
list ofsupported operating systems and compatible third-party
software.
Technical notesThis information is intended to supplement any
installation procedures or defectworkarounds.CQ612679:
xmlcollector-vmax-topo.xml file changesXML to delete:
-
not(contains(configuration,'3-Way')) and
not(contains(configuration,'4-Way'))]) then (. * 2) else ( if
(../../Dev_Info[contains(configuration,'3-Way')]) then (. * 3) else
( if (../../Dev_Info[contains(configuration,'4-Way')]) then (. * 4)
else (.) ) ) ) )" />
In place of the deleted XML, insert this one:
Release Notes
Technical notes 21
-
Troubleshooting and getting helpFor product information and
assistance, you can contact EMC Technical Support.Procedureu For
documentation, videos, release notes, software updates, or
information about
EMC products, go to EMC Online Support at
https://support.emc.com.u For technical support, go to EMC Online
Support and click Service Center.
You must have a valid support agreement to open a service
request.u Contact your EMC sales representative for details about
obtaining a valid support
agreement or with questions about your account.
DocumentationAdditional documentation is available and updated
periodically.Table 1 Related documentation
Document Revision Part number- - -EMC Storage Resource
Management 3.0 User and AdministrationGuide
01 302-000-514
EMC Storage Resource Management 3.0 Installation
andConfiguration Guide
01 302-000-506
EMC Storage Resource Management 3.0 Open Source License
andCopyright Information
01 302-000-515
EMC Storage Resource Management 3.0 Open Source License
andCopyright Information for GPLv3 as Included with a Distribution
ofSLES 11
01 302-000-516
EMC Storage Resource Management 3.0 Ports Usage and Worksheet 01
302-000-507EMC Storage Resource Management 3.0 Documentation
Portfolio 01 302-000-517EMC Storage Resource Management 3.0
Security ConfigurationGuide
01 302-000-513
EMC Storage Resource Management 3.0 Support Matrix 01
302-000-510
Electronic versions of the updated manuals are available on EMC
Online Support at https://support.emc.com.
Documentation errataThis section lists corrections required in
the documentation.
EMC Storage Resource Management Suite Installation and
Configuration GuideCorrection to "Enabling passive host discovery
through Generic-SNMP" procedureReplace the current procedure with
the following:1. Click Administration > Centralized
Management.
Release Notes
22 EMC Storage Resource Management Suite 3.0 Release Notes
-
2. Click SolutionPacks.3. Under Independent SolutionPack Blocks,
click to reconfigure the Generic-SNMP
SolutionPackBlock instance.4. Select the Enable Passive Host
Discovery checkbox.5. Click Reconfigure.6. In Device Discovery >
Dashboard > Device Distribution.7. Click Distribute all approved
devices with capabilities on all
enabled collectors.8. Click Send the generated configurations on
all available
collectorsSNMP configurations missing for Brocade switchesIn
chapter 5, "Infrastructure Preparation for Discovery and Data
Collection," sub-section"Brocade switch configuration," procedures
identical to the following Cisco switchconfiguration are
required.Configure switches for SNMPv1You have to configure Brocade
switches for SNMPv1 to enable discovery, data collection,and alert
consolidation for the switches. The SNMPv1 information you provide
whenperforming discovery is necessary for SRM Suite to contact the
switch to obtaininformation.1. Log into the Brocade FC switch as
the administrator.2. Type snmpConfig --set snmpv1 , and press
Enter.3. When prompted, type the Community string to be configured
on the switch.
Ignore the other fields that you are prompted to type.Configure
switches for SNMPv3You have to configure Brocade switches for
SNMPv3 to enable discovery, data collection,and alert consolidation
for the switches. The SNMPv1 information you provide whenperforming
discovery is necessary for SRM Suite to contact the switch to
obtaininformation.1. Log into the Brocade FC switch as the
administrator.2. Type snmpConfig --set snmpv3 , and press Enter.3.
Type the following details, when prompted:
Option Description- -User (rw) The SNMP v3 user to be configured
on the switch.Auth Protocol [MD5(1)/SHA(2)/noAuth(3)] The
authentication protocol required.New Auth Passwd: Authentication
password.Verify Auth Passwd: Retype the authentication
password.Priv Protocol [DES(1)/noPriv[2]): The Privacy protocol
required.New Priv Passwd: The privacy password.Verify Priv Passwd:
Retype the privacy password.
Release Notes
Documentation errata 23
-
EMC Storage Resource Management Suite Support MatrixCorrection
to supported CMCNE/BNA versions in Table 5 Supported models for
BrocadeFabric supportIn the topic "SolutionPack for Brocade FC
Switch", "Table 5 Supported models forBrocade Fabric", the
CMCNE/BNA support should also include CMCNE/BNA 12.x:
Supported model Collector Prerequisites Port- - - -l Brocade
300, 4100, 4900, 5000, 510, 5300, 5410, 5424, 5450,
5460, 5470, 5480, 7500, 7500E, 7600l Brocade 7800 Extension
Switchl Brocade 8000 FCoE Switchl Brocade Encryption SwitchBrocade
DCX
Backbone and Brocade DCX-4S Backbone: FA4-18 Fibre
Channelapplication blade,FCOE10-24 DCX Blade, FS8-18 Encryption
Blade, FC8-16 port blade,FC8-32 port blade,FC8-48 port blade,
FC8-64 port blade
l Fabric OS MIB Reference: 53-1001768-01, FC10-6 port
blade,FR4-18i router blade, FX8-24 DCX Extension Blade
l Brocade 48000 director: FA4-18 Fibre Channel application
blade,FC4-16 port blade, FC4-16IP, FC4-32 port blade, FC4-48 port
blade,FC10-6 port blade, FR4-18i outer blade
l Brocade VA-40FC
Generic-SNMPXMLCollector
All Brocade switches thatare running FOSv4.x orhigher. SNMP
compliantwith FC-MGMTMIB.Providers:l CMCNE/BNA 11.1.x,
11.2.1, 12.xl CMDCE/DCFM 10.4.x
SNMP(defaultport is161)
Corrections to footnotes in Table 5 Supported models for Brocade
Fabric supportFootnotes b,f, and h for Table 5 are not accurate.
They should read as follows:u Footnote b: "SRM Suite requires the
integrated SMI Agent (CMCNE/BNA,CMDCE/
DCFM) to discover NPIV enabled Switch Ports and Access Gateway
capabilities."u Footnote f: "Discovery is limited to FC blades.
Discovery supports only the E, F, and G
ports on the blades. SRM Suite does not support Administrative
Domains features."u Footnote h is incorrectly applied to only
CMCNE/BNA 11.1.x. This note is a generic
note for all CMCNE/BNA versions, and not specific to CMCNE/BNA
11.1.x.Corrections to Table 6 Supported models for Cisco fabricIn
the topic, "SolutionPack for Cisco MDS/Nexus", "Table 6 Supported
models for Ciscofabric", the Collector column should only include
Generic-SNMP. Remove Text-Collector.Port incorrect in SolutionPack
for EMC Host Interface table 12In the topic, "SolutionPack for EMC
Host Interface", "Table 12 Supported hosts in SRMSuite", contains a
typo. The Port column should have the following content:"Default
ports are 5988 and 5989 (secure)"
EMC Storage Resource Management Suite Security Configuration
GuideSolutionPack for EMC VNX: Navisphere SSL certificate
settingAdd this new topic to the "Communication security settings"
sub-section of the "Securityconfiguration settings" chapter in the
EMC Storage Resource Management Suite SecurityConfiguration
Guide.
Release Notes
24 EMC Storage Resource Management Suite 3.0 Release Notes
-
" Navisphere is installed with a default security level of low.
If you need to increase thesecurity level to medium, this can be
done using /opt/Navisphere/bin/setlevel_cli.sh.1. At the command
prompt, type /opt/Navisphere/bin/setlevel_cli.sh and press
Enter.2. Type m when prompted:
Please enter the verifying level(low|medium|l|m) to set?mSetting
medium verifying level..... Verification level medium has been set
SUCCESSFULLY!!!
3. Confirm if a Naviseccli command runs without a prompt.
Release Notes
Documentation errata 25
-
Copyright 2013-2014 EMC Corporation. All rights reserved.
Published in USA.Published January 03, 2014EMC believes the
information in this publication is accurate as of its publication
date. The information is subject to change withoutnotice.The
information in this publication is provided as is. EMC Corporation
makes no representations or warranties of any kind withrespect to
the information in this publication, and specifically disclaims
implied warranties of merchantability or fitness for aparticular
purpose. Use, copying, and distribution of any EMC software
described in this publication requires an applicable
softwarelicense.EMC, EMC, and the EMC logo are registered
trademarks or trademarks of EMC Corporation in the United States
and other countries.All other trademarks used herein are the
property of their respective owners.For the most up-to-date
regulatory document for your product line, go to EMC Online Support
(https://support.emc.com). Fordocumentation on EMC Data Domain
products, go to the EMC Data Domain Support Portal
(https://my.datadomain.com).
Release Notes
26 EMC Storage Resource Management Suite 3.0 Release Notes
Revision historyProduct descriptionNew features and changesKnown
problems and limitationsInstallationEnvironment and system
requirementsTechnical notesTroubleshooting and getting
helpDocumentationDocumentation errata