Installation work check list for Flexi BSC
and TCSM3i
DN70596578
Issue 1-0
7/28/2019 dn70596578.pdf
http://slidepdf.com/reader/full/dn70596578pdf 2/18
2 DN70596578
Issue 1-0
Installation work check list for Flexi BSC and TCSM3i
Id:0900d805804d6a14
The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-
TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-
RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED
TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY
OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION
IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2009/10/19. All rights reserved
f Important Notice on Product SafetyElevated voltages are inevitably present at specific points in this electrical equipment.
Some of the parts may also have elevated operating temperatures.
Non-observance of these conditions and the safety instructions can result in personal
injury or in property damage.
Therefore, only trained and qualified personnel may install and maintain the system.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected
has to comply with the applicable safety standards.
The same text in German:
Wichtiger Hinweis zur Produktsicherheit
In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Span-
nung. Einige Teile können auch eine hohe Betriebstemperatur aufweisen.
Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverlet-
zungen und Sachschäden führen.
Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die
Anlagen installiert und wartet.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene
Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.
7/28/2019 dn70596578.pdf
http://slidepdf.com/reader/full/dn70596578pdf 3/18
DN70596578
Issue 1-0
3
Installation work check list for Flexi BSC and TCSM3i
Id:0900d805804d6a14
Table of ContentsThis document has 18 pages.
Summary of changes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2 Check list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.1 Checking the availability of documents and tools . . . . . . . . . . . . . . . . . . 7
2.2 Unpacking and checking the equipment . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.3 Preparing the cabinets for installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.4 Installing the cabinets on their own feet. . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.5 Installing the cabinet on floor rails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.6 Installing the Side cable conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.7 Grounding (earthing) the cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.8 Connecting the site power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.9 Attaching and filling in the labels and stickers . . . . . . . . . . . . . . . . . . . . 13
2.10 Installing the internal cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.11 Replacing Fan Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.12 Creating a temporary ESD-protected area for fieldwork . . . . . . . . . . . . 14
2.13 Equipping the cartridges with plug-in units . . . . . . . . . . . . . . . . . . . . . . 14
2.14 Cabling to environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.15 Installing the External Alarm Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.16 Finishing the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.17 Additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7/28/2019 dn70596578.pdf
http://slidepdf.com/reader/full/dn70596578pdf 4/18
4 DN70596578
Issue 1-0
Installation work check list for Flexi BSC and TCSM3i
Id:0900d805804d6a14
7/28/2019 dn70596578.pdf
http://slidepdf.com/reader/full/dn70596578pdf 5/18
DN70596578
Issue 1-0
5
Installation work check list for Flexi BSC and TCSM3i Summary of changes
Id:0900d805804c569a
Summary of changesChanges between document issues are cumulative. Therefore, the latest document
issue contains all changes made to previous issues.
Issue 1-0
This is the first issue of Installation Work Check List for Flexi BSC and TCSM3i , based
on document Installation Work Check List, BSC3i and TCSM3i Installation. Flexi BSC
product family has been introduced on S14 level, and therefore the title has been
changed.
7/28/2019 dn70596578.pdf
http://slidepdf.com/reader/full/dn70596578pdf 6/18
6 DN70596578
Issue 1-0
Installation work check list for Flexi BSC and TCSM3i
Id:0900d805804a7d6f
Overview
1 OverviewThe purpose of the installation work is to check the delivery, to install the Flexi BSC and
the TCSM3i to the site, to prepare the network elements, and to check that the site is
ready for commissioning.
The purpose of Installation work check list for Flexi BSC and TCSM3i is to ensure the
quality of installation work. It provides Check list and, in the Appendix, Installation Cer-
tificate of Completion for checking the installation of the Flexi BSC and the TCSM3i. The
Check list is to be updated after each work phase.
Also, Site Deficiency Report and Failure Report are generated during the work. The fol-
lowing documents are referred to in the Check list :
• Installing Flexi BSC and TCSM3i
• Installation Site Requirements for Flexi BSC and TCSM
• Connector Panels and External Cables in Flexi BSC and TCSM3i
• Engineering for Flexi BSC
• Engineering for TCSM3i
• Interconnection cables in Flexi BSC
• Interconnection cables in TCSM3i
• Cabling Instructions for Flexi BSC
• Cabling Instructions for TCSM3i
• Equipment List for Flexi BSC
• Equipment List for TCSM3i
• Packing List and/or Despatch Note
7/28/2019 dn70596578.pdf
http://slidepdf.com/reader/full/dn70596578pdf 7/18
DN70596578
Issue 1-0
7
Installation work check list for Flexi BSC and TCSM3i Check list
Id:0900d805804bf2ac
2 Check listThe tables in the following sections provide check lists to be updated after each work
phase.
2.1 Checking the availability of documents and tools
Check the availability of documents and tools needed for installation.
2.2 Unpacking and checking the equipment
Prepare the equipment room and unpack and check the equipment.
Preparing the equipment room
Installation phase and related documents Completed
Check the availability of the documents needed for installation.
Acquire missing documents.
See: Installing Flexi BSC and TCSM3i, section About the installa-
tion of Flexi BSC
Check the availability of the tools needed for installation. Acquiremissing tools.
See: Installing Flexi BSC and TCSM3i, section About the installa-
tion of Flexi BSC and TCSM3i
Installation phase and related documents CompletedEnsure that all basic work such as installation of lighting, fire extin-
guishing and air conditioning equipment has been completed.
See: Installing Flexi BSC and TCSM3i, section Unpacking and
checking the equipment
Check against the floor plan for the site that all cable shelves and
gratings separate from the equipment itself are ready.
See: Installing Flexi BSC and TCSM3i, section Unpacking and
checking the equipment
Ensure that the site power supply system has been properly
installed and that it is ready for use.
See: Installing Flexi BSC and TCSM3i, section Unpacking and checking the equipment
Ensure that the ventilation equipment has been properly installed
and that the temperature in the equipment room is within the limits
allowed for the DX 200 equipment.
See: Installing Flexi BSC and TCSM3i, section Unpacking and
checking the equipment, and Installation site requirements for
Flexi BSC and TCSM3i section Cooling of DX 200 equipment
Make the needed additional holes in raised floors and correct
installation floor plan.
Ensure that the premises are properly cleaned.
See: Installing Flexi BSC and TCSM3i, section Unpacking and checking the equipment
7/28/2019 dn70596578.pdf
http://slidepdf.com/reader/full/dn70596578pdf 8/18
7/28/2019 dn70596578.pdf
http://slidepdf.com/reader/full/dn70596578pdf 9/18
DN70596578
Issue 1-0
9
Installation work check list for Flexi BSC and TCSM3i Check list
Id:0900d805804bf2ac
2.5 Installing the cabinet on floor rails
Install the cabinets on floor rails according to the floor plan.
Installing the floor rails
Installation phase and related documents Completed
Study the floor plan.
See: Installation site requirements for Flexi BSC and TCSM3i section Equipment room layout
Adjust all four feet of the cabinet (or cabinets) to an initial height
of about 50 mm (2 in).
See: Installing Flexi BSC and TCSM3i, section Installing the
cabinets on their own feet
Place the cabinet to its final place according to the floor plan.
See: Installing Flexi BSC and TCSM3i, section Installing the
cabinets on their own feet
Level off the cabinet in the width and depth direction using a spirit
level as a reference.
See: Installing Flexi BSC and TCSM3i, section Installing the
cabinets on their own feet
If two or more Flexi BSCs or TCSM3is are installed, repeat the
steps mentioned above.
See: Installing Flexi BSC and TCSM3i, section Installing the
cabinets on their own feet
Attach the cabling cabinet to the equipment cabinet by using bolts
for attachment.
When installing an upgrade-delivery Flexi BSC, attach the base
cabinet and the extension cabinet by using bolts for attachment.
When installing the TCSM3i for combined BSC/TCSM installation
option, attach the TCSA cabinet to the BSC-part by using bolts for
attachment.
In a row consisting of several network elements, attach the
network elements firmly to one another, but do not use any bolts
for attachment.
Installation phase and related documents Completed
Study the floor plan.
See: Installation site requirements for Flexi BSC and TCSM
section Equipment room layout
Determine the insertion points on the floor for the attachment
screws for the first rail.
See: Installing Flexi BSC and TCSM3i, section Installing the
cabinets on floor rails
7/28/2019 dn70596578.pdf
http://slidepdf.com/reader/full/dn70596578pdf 10/18
10 DN70596578
Issue 1-0
Installation work check list for Flexi BSC and TCSM3i
Id:0900d805804bf2ac
Check list
Installing the Floor Rail Installation Set
Mounting the cabinet on floor rails
Drill the holes for the screws and lodge a wedge anchor in each
hole.
See: Installing Flexi BSC and TCSM3i, section Installing thecabinets on floor rails
Repeat the procedure mentioned above for the other rail.
See: Installing Flexi BSC and TCSM3i, section Installing the
cabinets on floor rails
Place the rails to their final places and level them off.
See: Installing Flexi BSC and TCSM3i, section Installing the
cabinets on floor rails
In IBN installation, mount the insulation tube in the first hole,
followed by the insulation washer, the washer and the attachment
screw. Screw in the screw loosely.
Repeat the procedure mentioned above to all attachment pointsfor both rails.
See: Installing Flexi BSC and TCSM3i, section Installing the
cabinets on floor rails
After attaching all screws, tighten them.
See: Installing Flexi BSC and TCSM3i, section Installing the
cabinets on floor rails
In IBN installation, check that the attachment screws are not elec-
trically connected to the rail.
See: Installing Flexi BSC and TCSM3i, section Installing the
cabinets on floor rails
Installation phase and related documents Completed
Insert the cabinet attachment pieces inside the floor rails.
See: Installing Flexi BSC and TCSM3i, section Installing the
cabinets on floor rails
Place the support bars crosswise to the rails, each bar on a pair
of cabinet attachment pieces.
See: Installing Flexi BSC and TCSM3i, section Installing the
cabinets on floor rails
Move the support bars to approximately their final positions
lengthwise on the rails.
See: Installing Flexi BSC and TCSM3i, section Installing the
cabinets on floor rails
Installation phase and related documents Completed
Remove the feet from the cabinet.
See: Installing Flexi BSC and TCSM3i, section Installing the
cabinets on floor rails
Installation phase and related documents Completed
7/28/2019 dn70596578.pdf
http://slidepdf.com/reader/full/dn70596578pdf 11/18
DN70596578
Issue 1-0
11
Installation work check list for Flexi BSC and TCSM3i Check list
Id:0900d805804bf2ac
2.6 Installing the Side cable conduit
Install the Side cable conduit (SCC). It can be installed at either side of the equipment
cabinet. When the SCC is used, the cabling cabinet cannot be used.
It is recommended to install and tie the cables entering the cabinet through the conduit
before installing the conduit panel.
2.7 Grounding (earthing) the cabinet
Ground (earth) the cabinets.
Place the installation ramp in front of the rail, between the
support bars for the cabinet and press the support bars against
the sides of the ramp.See: Installing Flexi BSC and TCSM3i, section Installing the
cabinets on floor rails
Roll the cabinet along the ramp onto the support bars.
See: Installing Flexi BSC and TCSM3i, section Installing the
cabinets on floor rails
Loosely attach the cabinet to the attachment pieces using
M10x40 hex bolts.
See: Installing Flexi BSC and TCSM3i, section Installing the
cabinets on floor rails
Push the cabinet sideways along the rails to its final position.
See: Installing Flexi BSC and TCSM3i, section Installing thecabinets on floor rails
Attach the equipment cabinet by using bolts for attachment.
Attach the cabling cabinet to the equipment cabinet by using
bolts for attachment.
When installing the TCSM3i for combined BSC/TCSM installa-
tion option, attach the TCSA cabinet to the BSC-part by using
bolts for attachment.
In a row consisting of several network elements, attach the
network elements firmly to one another, but do not use any bolts
for attachment.
Installation phase and related documents Completed
Installation phase and related documents Completed
Install two mounting brackets in the upper and lower holes of the
cabinet using screws, washers and nuts.See: Installing Flexi BSC and TCSM3i, section Installing the
Side cable conduit
Install the conduit panel on the mounting brackets using
washers and screws.
See: Installing Flexi BSC and TCSM3i, section Installing the
Side cable conduit
7/28/2019 dn70596578.pdf
http://slidepdf.com/reader/full/dn70596578pdf 12/18
12 DN70596578
Issue 1-0
Installation work check list for Flexi BSC and TCSM3i
Id:0900d805804bf2ac
Check list
Connecting the standard ground cable
In installations on a raised floor, the main ground cable is routed through the SCC onto
the cable structures under the floor, and to the main ground bar of the site.
Connecting the ground cable with NEBS-compliant bracket
In installations on a raised floor, the main ground cable is routed through the SCC onto
the cable structures under the floor, and to the main ground bar of the site.
2.8 Connecting the site power supply
Connect the site power supply.
Installing Earth comb panels (CPGOs)
Installation phase and related documents Completed
Install the main ground cable to the grounding connector.
See: Installing Flexi BSC and TCSM3i, section Grounding the
cabinets
Measure and cut a 25 mm² (AWG 4) cable which connects the
network element to the main ground bar of the site (one cable
per network element).
See: Installing Flexi BSC and TCSM3i, section Grounding the
cabinets
Installation phase and related documents Completed
Install the NEBS-compliant cable bracket to the grounding con-
nector.
See: Installing Flexi BSC and TCSM3i, section Grounding the
cabinets
Install the grounding lug, with a cable crimped to it, to the
grounding bracket with two M6 hex socket screws.
See: Installing Flexi BSC and TCSM3i, section Grounding the
cabinets
Measure and cut a 25 mm² (AWG 4) cable which connects the
network element to the main ground bar of the site (one cable
per network element).
See: Installing Flexi BSC and TCSM3i, section Grounding the
cabinets
Installation phase and related documents Completed
Install the Earth comb panel (CPGO) at the BSCC cabinet top
in the hole on right-hand side (seen from front) of the Connector
panel (CPRJ45-A). Secure it with four Allen-head screws.
See: Installing Flexi BSC and TCSM3i, section Connecting the
site power supply
7/28/2019 dn70596578.pdf
http://slidepdf.com/reader/full/dn70596578pdf 13/18
DN70596578
Issue 1-0
13
Installation work check list for Flexi BSC and TCSM3i Check list
Id:0900d805804bf2ac
Connecting power supply cables
2.9 Attaching and filling in the labels and stickers
Attach and fill in the labels and stickers.
Note, however, that in first deliveries, the network element identification sticker is
attached to the cabinet at the factory.
2.10 Installing the internal cablesInstall the internal cables.
2.11 Replacing Fan Trays
The equipment cabinet contains four Fan Trays (FTRB-A or FTRB) for forced cooling.
The Fan Trays have been installed at the factory into special slots contained on shelves
2 and 4 (BSCC and BSCD) and on shelves 1 and 4 (TCSA) in the cabinet. If you haveto replace them, follow the instructions given in the installing document.
Installation phase and related documents Completed
Connect the main supply cables from the rectifiers to the four
power connector blocks (PSCG3-B) on the top structure of the
cabinet.
See: Installing Flexi BSC and TCSM3i, section Connecting the
site power supply
Installation phase and related documents Completed
Attach labels (the network element identification sticker and
cabinet identification and positioning sticker).
See: Installing Flexi BSC and TCSM3i, section Attaching iden-
tification stickers and marking labels
Fill in the labels.
See: Installing Flexi BSC and TCSM3i, section Attaching iden-
tification stickers and marking labels
Installation phase and related documents Completed
Check that the cabling lists are available.
See: Installing Flexi BSC and TCSM3i, section Installing the
internal cables
See also: Site Documents Interconnection Cables in Flexi
BSC , Interconnection Cables in TCSM3i , Cabling Instructions
for Flexi BSC and Cabling Instructions for TCSM3i
Install the internal cabling according to the cabling lists.
See: Installing Flexi BSC and TCSM3i, section Installing the
internal cables
See also: Site Documents Interconnection Cables in Flexi
BSC , Interconnection Cables in TCSM3i , Cabling Instructions
for Flexi BSC and Cabling Instructions for TCSM3i
7/28/2019 dn70596578.pdf
http://slidepdf.com/reader/full/dn70596578pdf 14/18
14 DN70596578
Issue 1-0
Installation work check list for Flexi BSC and TCSM3i
Id:0900d805804bf2ac
Check list
Removing a Fan Tray
Installing a Fan Tray
2.12 Creating a temporary ESD-protected area for fieldwork
Create a temporary ESD-protected area (EPA) for field work.
It is strongly recommended that the entire installation site be constructed according to
EPA rules.
2.13 Equipping the cartridges with plug-in units
Equip the cartridges with plug-in units.
Installation phase and related documents Completed
Remove cables from the FTRB-A (FTRB).
See: Installing Flexi BSC and TCSM3i, section Installing and
replacing Fan Trays
Pull the FTRB-A out of the shelf.
See: Installing Flexi BSC and TCSM3i, section Installing and
replacing Fan Trays
Installation phase and related documents Completed
Insert the FTRB-A (FTRB) into the shelf: slide the locks on thefront of the FTRB-A (FTRB) towards each other and push the
Fan Tray gently into its shelf (positions 2 and 4, or positions 1
and 4) until it clicks into place.
See: Installing Flexi BSC and TCSM3i, section Installing and
replacing Fan Trays
Connect cables into the FTRB-A (FTRB):
• connect the power cable from connector P7 in the corre-
sponding PDFU-B (S11.5 onwards) PDFU-A (S11 or
S10.5) to the back connector of the FTRB
• connect Alarm cabling from CLOC-B to the back connec-
tor of the FTRB-A (FTRB)
• connect grounding cable from the shelf to the FTRB-A(FTRB).
See: Installing Flexi BSC and TCSM3i, section Installing and
replacing Fan Trays
Installation phase and related documents Completed
Create a temporary EPA.
See: Installing Flexi BSC and TCSM3i, section Creating a
temporary ESD protected area (EPA) for fieldwork
7/28/2019 dn70596578.pdf
http://slidepdf.com/reader/full/dn70596578pdf 15/18
DN70596578
Issue 1-0
15
Installation work check list for Flexi BSC and TCSM3i Check list
Id:0900d805804bf2ac
Preliminary checks
Precautions
Replacing DCAR1-A
Installing plug-in units
Install plug-in units if they have not been installed at the factory. Follow the instructions
below.
Installation phase and related documents Completed
Check the following:
• PROM versions of the plug-in units
• interchangeability codes of the plug-in units
• jumper connectors on the plug-in units.
See: Installing Flexi BSC and TCSM3i, section Equipping the
cartridges with plug-in units
Installation phase and related documents Completed
Familiarise yourself with precautions to be taken.See: Installing Flexi BSC and TCSM3i, section Equipping the
cartridges with plug-in units
Ensure that you are working in an electrostatic free environ-
ment.
See: Installing Flexi BSC and TCSM3i, section Equipping the
cartridges with plug-in units
Handle the plug-in units with care at all installation phases.
See: Installing Flexi BSC and TCSM3i, section Equipping the
cartridges with plug-in units
Installation phase and related documents Completed
Replace the DCAR1-A.
See: Installing Flexi BSC and TCSM3i, section Equipping the
cartridges with plug-in units
Installation phase and related documents Completed
Check the code of the plug-in unit positions. Record and
correct the differences according to jumper setting instruc-
tions.
See: Installing Flexi BSC and TCSM3i, section Equipping the
cartridges with plug-in units
See also: Site Document Equipment list for Flexi BSC , Equip-
ment list for TCSM3i
Install the EMC shielding springs.
See: Installing Flexi BSC and TCSM3i, section Equipping the
cartridges with plug-in units
7/28/2019 dn70596578.pdf
http://slidepdf.com/reader/full/dn70596578pdf 16/18
16 DN70596578
Issue 1-0
Installation work check list for Flexi BSC and TCSM3i
Id:0900d805804bf2ac
Check list
2.14 Cabling to environment
Install the cables to environment.
2.15 Installing the External Alarm Unit
Install the External Alarm Unit (EXAU-A).
2.16 Finishing the installation
Finish the installation.
Use an EDS wrist strap earthing device!
Insert all the plug-in units (including I/O devices) in the car-
tridges after checking of identification labels.
Leave the plug-in units unconnected.
See: Installing Flexi BSC and TCSM3i, section Equipping the
cartridges with plug-in units
See also: Site Document Equipment list for Flexi BSC , Equip-
ment list for TCSM3i
Install the power supply units.
See: Installing Flexi BSC and TCSM3i, section Equipping the
cartridges with plug-in units
Switch power supply units on. Check the function of the units
from the LED indicators.
See: Installing Flexi BSC and TCSM3i, section Equipping the
cartridges with plug-in units
Installation phase and related documents Completed
Installation phase and related documents Completed
For information on connector panel types, see: Installing
Flexi BSC and TCSM3i, section Interfaces to environment
For information on installing connector panels, see: Installing Flexi BSC and TCSM3i, section Interfaces to environment
For information on connector panels and external cables,
see: Connector Panels and External Cables in Flexi BSC
and TCSM3i
Installation phase and related documents Completed
Mount the External Alarm Unit on the wall and connect thealarm cable.
See: Installing Flexi BSC and TCSM3i, section Installing the
External Alarm Unit (EXAU-A)
Installation phase and related documents Completed
Remove all temporary markings.
7/28/2019 dn70596578.pdf
http://slidepdf.com/reader/full/dn70596578pdf 17/18
DN70596578
Issue 1-0
17
Installation work check list for Flexi BSC and TCSM3i Check list
Id:0900d805804bf2ac
2.17 Additional information
Information on powering down of the network element is found in Installing Flexi BSC
and TCSM3i, section Powering down. Information on the external cables including
requirements specifications for the cables is found in Connector Panels and External
Cables in Flexi BSC and TCSM3i .
Check the corrections in drawings used during the installa-
tion.
Reinstall the doors.
See: Installing Flexi BSC and TCSM3i, section Finishing the
installation
Connect the grounding cables between the doors and the
cabinet frame.
See: Installing Flexi BSC and TCSM3i, section Finishing the
installation
Clean the installation site.
Fill in the Installation certificate of completion, in the Appen-
dix.
Installation phase and related documents Completed
7/28/2019 dn70596578.pdf
http://slidepdf.com/reader/full/dn70596578pdf 18/18
18 DN70596578
Installation work check list for Flexi BSC and TCSM3i
Id:0900d8058049d01c
Appendix
3 Appendix
Installation certificate of completion
STAGE
Date
Network element installed by
(Also Print Name)
Customer
(Also Print Name)
COMPLETE/OK (Initials)
COMMENTS/DEFICIENCY
CUSTOMER NAME
DELIVERY NO.
SITE NAME
SITE NO.
SITE ADDRESS
SOFTWARERELEASE
DN02198294
Checking the availability of documents and toolsUnpacking and checking the equipmentPreparing the cabinet for installationInstalling the cabinet on its own feetInstalling the cabinet on floor railsInstalling the Side Cable ConduitGrounding (earthing) the cabinetConnecting the site power supply
Attaching and filling in the labels and stickersInstalling the internal cablesReplacing Fan TraysCreating a temporary ESD-protected areaEquipping the cartridges with plug-in units
Cabling to environmentInstalling the External Alarm UnitFinishing the installation