DN2 TRAINING OVERVIEW
ROB WHITE
Tel +44(0)7771 821908
Email: [email protected]
Course structure
•Introductions
•2M Frame Structure
•Sub rack and Power
•DN2 installation and configuration including tables
•MSTE and DN2 manager
•Open forum and wash up
Workshop Program
E1 Transmission Format
• A Frame;
• An E1 system consists of 32 time slots which contain the 64 kbit/s consecutive samples. This is called a frame.
• The Transmission Rate;
• When combined together 32 time slots x 64 Kbits/s = 2048 Kbits/s which is the speed of the E-1 transmission system.
• ITU-T Specifications;
• ITU-T Rec. G.703
– Bit rate: 2048 Kbit/s
– Line Code: HDB3 (high density bipolar 3)
• Time Slot 16 : Frames 2 through 15 are the same as frame 1• Time Slot 0: Even number frames 2 through 14 are the same as frame 0• Time Slot 0: Odd number frames 3 through 15 are the same as frame 1
1 = bit set to 1 0 = bit set to 0 1/0 = speech / signalling (varying data) X = unassigned bit
(normally set to 1)
10 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Multiframe (16 frames)
Frame 0 (32 Time Slots)10 2 3 4 5 6 7 8 9 101112131415 1716 1819202122232425262728293031
Frame 1 (32 Time Slots)10 2 3 4 5 6 7 8 9 101112131415 1716 1819202122232425262728293031
Time Slot 0 (8 bits)
0X 0 1 1 0 1 110
10
10
10
10
10
10
10
Time Slot 1 Speech (Ch. 1)
Time Slot 16 (8 bits)
00 0 0 X 0 X X
Time Slot 0 (8 bits)
1X 0 X X X X X
Time Slot 16 Signalling Bits10
10
10
10
10
10
10
10
SpeechCh. 1-15
SpeechCh. 16-30
SpeechCh. 1-15
SpeechCh. 16-30
Frame
Time Slot
Frame Alignment
Word
Multi-Frame
Alignment Word
Not-Frame alignment word
A B CD A B CD
ITU-T Rec. G.704
• diagram illustrating how CAS information is sent.
2M Frame
• Diagram of the E1 frame.
Questions?
DYNANET PRODUCTS
DM2
DB2
DN2
Dynacard Bus - Core of DYNANET Nodes
VF SUB
Dynacard bus
VF DCLOOP
VF E&M
DATA 0..19.2k
DATA 48..64k
DATA nx64k
ISDN
ILT (HDSL)
nx64k G.704
ADPCM
DN2/DB2/DM2
N x 2M
PIA Replacement Tips
• Can not be managed by MSTE• Always check strapping of removed unit and change where different on
replacement unit• ON/OFF switch is physically locked into ON position by a retaining bar. However
it is a toggle type and therefore it is possible that it has ‘tripped’ to the OFF state while physically remaining in the ON position. Releasing from the retaining bar and resetting trip is obtained by physically moving position to OFF and back to ON.
NokiaDynaMech DC/DC Rack powered
Power Supply RPSAT73880.01
Sub Rack T37870.01
RPM 37881.01Alm 37886.01
NDA 37884.01
DC -48V
NokiaDynaMech DN2 shelf
T37882.01 NDM DC Unit (NDU)
DC -48V or 240 V DC
Sub Rack T37871.01
T37883.01 NDM AC/DC Unit (NAU)
Power Supply RPSAT73880.01
NDA 37884.01
Questions?
• Operation of service LEDs
• The red service LED of the MCU is lit when there is a serious fault in the equipment. If the MCU is powered up and the red LED still stays on, the unit should be replaced.
• The red LED on a DYNACARD (PIU) unit indicates that either there is a serious fault in the unit or the unit has not been added to the equipment configuration.
• Note: The red LED of any unit is lit when an external power supply fails to provide the operating voltages required.
• The yellow service LED is lit when the unit has detected a fault outside the equipment (the incoming signal may be faulty, for example). Some of the services may still be functioning quite normally and further actions are needed for locating the fault.
• The green service LED is lit when the unit is accessed by the Service Terminal or MSTE, or the Nokia DCNA
• Connection to the DCNA does not activate the green LED in all cases.
Alarms and LEDs
2MMUX
DN2
2MMUX
LOSLFA
LMFA
FEA/RDI
AIS
2MMUX
2MMUX
DN2
8MMUX
8MMUX
DN2
NO ALARMON 8M LINK
2MMUX
2MMUX
DN2
8MMUX
8MMUX
DN2
LOSAISAIS
AIS AIS AIS
FEA/RDI
FEA/RDI
FEA/RDI
LOSLFA
LMFA
PDH Alarms
Service Terminal Overview
Nokia TC21700 Service terminal (ST)
•Used to make configuration changes onNokia Dynanet equipment (Network Element – NE)
•“MODE” key to setup ST or check battery charge etc.
•“OBJ” key to connect to the equipment:Connect cable to SI (Service Interface) on NEObj2,address to connect properlyOR as a last resort (ensuring no other management connections)Obj7, Connect on default address 4095
•“TOP” key, once connected to NE to access NE’sconfiguration menu
•Use the menu structure to show configuration.
•Menu differs between different types of card. •All service menus shown in the relevant Nokia manual
As you can see from above the DN2 NM gives you a shelf layout of the Data Cards.MSTE is essentially the mml tool you will use to switch on/off channels, change settings etc.
MSTE GUIDN2 Node Manager GUI
Node Managers
Nokia MSTE 4.3
•PC based Service Terminal Emulator.
•More flexible and user friendly interface
•Uses same menu structure as Service Terminal
•Connects Via PC Com Port(with appropriate cable)
•Utilises Q1 connection tool and GCS Database
MSTE (Macro STE) overview
Questions?
MSTE Saving card configurations
Saving the Dynacard set up data to file using MSTE
•Card data saved individually•Files saved as with .STD Extension•Files saved in C:\Program Files\Nokia\Mste\data
MSTE Restoring card configurations
Restoring the Dynacard set up data to file using MSTECard data saved individually•Files saved as with .STD Extension•Files saved in C:\Program Files\Nokia\Mste\data
DN 2 - DYNAMIC NODE EQUIPMENT
• Consists of a control unit (CU), a bus power unit (BPU) and interface units (IU2). The BPU- and the IU2-units can be duplicated
• Direct data or speech interfaces provided by DYNACARD units
• n x 8 kbit/s, n x 64 kbit/s, 2 Mbit/s switching
• 1...40 x 2 Mbit/s (G.703/G.704) capacity
2M, G.703V.11
2M, G.704
2M, G.7042M, G.703
ISDNV./RS/X
V.F.
CU BPU IU2 IU2 CH
PIAIU2IU2IU2IU2IU2IU2IU2IU2IU2IU2
BPU
CU
• DN2 - Dynamic Node• Three-in-one node
– cross-connect– drop-insert– voice/data multiplexer
• Maximum capacity 40 x 2M• Several efficient ways to protect equipment
and/or signal route• Direct data or speech interfaces provided
by DYNACARD units• n x 8 kbit/s, n x 64 kbit/s, 2 Mbit/s
granularity• Used in mobile and fixed networks
2M, G.703V.11
2M, G.704
2M, G.7042M, G.703
ISDNV./RS/X
V.F.
DN2
DN2
PABX
DB2
DB2
DB2
DM2
DM2
DM2
DM2
PABX
NMS
DN2
Nokia DN2 Multiplexer
Units
DN2 consists of the following units:
• a control unit (CU)
• Bus Power Units (BPU or EBPU)
• Interface units (IU2)
• DYNACARD channel units
• DN 2 Mechanics and Backplane
IU2
IU2
IU2
IU2
IU2
IU2
IU2
IU2
IU2
IU2
CH/VF
CH/DIU
CU
BPU
PIA
IU2
Control Unit (CU)
• Same HW as in DM2• Main functions:
• Alarm database
• Service interface
• Dynacard bus
• Synchronization interface
• Configuration management
DC/DC
Control
Service InterfaceAux. Data Channel I/F
2M Interface
Meas. Interface
Dyna-CardBusI/F
Sync. Interface
Alarm Interface
DN2 CU Jumpers
VN5 Connected
VP5 Dis-connected
VNM Connected
CU Voltage Settings
Interface Unit (IU2)
• Main functions:• MUX/DEMUX 2M signal
• Statistics and faults of 2M signals
• Cross-connection
• Synchronization
DC/DC
Control
Aux. dataChannel I/F
2M Interface
Meas. Interface
Cross-Connection
FieldDN 2BusI/F
2M Interface
DN2 IU2 Jumpers
Disconnect VP5
IU2 Voltage Settings
(Extended) Bus Power Unit ((E)BPU)
• Bus power functions:
• +2 V to DN 2 cross-connection busses
• +5 V and -5 V to Dynacard bus• Extension functions:
• DN 2 bus extension
• Some DYNACARD bus signals, required by IU2s, also connected to other sub rack
• Duplication
• Two (E)BPUs can exist in a sub rack, one feeds the upper DN 2 bus and the other the lower bus
DM2 Extension interface(Only in EBPU)
DN 2 Extension Interface(Only in EBPU)
ControlBlock
PowerSupplyBlock
DN2 BPU Jumpers
Assuming EBPU protection not used
Use Option A
Connected
Dis-connected
BPU (EBPU) Voltage Settings
Configuration rule and suggestions
• IU2 always in slot 1 and in slot 17• IU2s in sequential slots• BPU/EBPU in the rightmost slot, if PIA not used, otherwise PIA in the rightmost
and BPU/EBPU next to it.• One CU for one node next to BPU/EBPU• Channel units between IU2s and CU
IU2
IU2
IU2
IU2
IU2
IU2
IU2
IU2
IU2
IU2
IU2
CH/VF
CH/DIU
CU
BPU
PIA
Plug-In -Units IU2 Interface unit 2x2Mbit/s CU Control Unit (E)BPU Bus Power Unit
Optional VF units Data units
DN2BUS1
DN2BUS2
IU2
(E)BPU
IU2
CU
.
.
.
.
.
.
DYNACARDBUS
VF-UNIT
DATA-UNIT
2 Mbit/s
2 Mbit/s
2 Mbit/s
2 Mbit/s
DN 2 - BLOCK DIAGRAM
2 Mbit/s
2 Mbit/s coax physical front connection
Questions?
DN2 Branching
• The DN 2 uses Tables to set up communications. These tables consist of different branches to allow this. the following are common branching types used within connect:
• Ordinary through connections (B-type)• Digital common channels (C-type)• Loopback (L-type)• Protection switch (Y-type)• Mask (M-type)• Examples:-
1 2
B2 Branch
3
1
2
VF
Site A DN2
To Site B
To Site CY Branch
• Always Default unit Top 6,6,121 RET• Install All Units Top 6,2,0• Set Q1 Address & Baud Rate• Set up Synch Plan• Set up Ports for MF Use, CRC etc• Is Dynacard bus being used ? (If No the Dynacards can`t be used)• Clear alarms using local loopback`s where possible.• Set up Dynacards & Ports and activate channels• Add cross-connects in DN2 Tables• Check Dynacard circuits work locally (where possible) around a 2 Mg Loop before extending.• Backup up DN2 Tables after new circuit additions & removals• Perform routine SW backups of DN2`s.
DN2 Commissioning Tips
DN2 Manager
Connect Send
Connect to DN2 Node
1. Open DN2 Manager from the start menu or from a desktop shortcut.
2. Select the ‘Connect’ button to open the ‘Nokia connection tool’ window.
3. Select the type of connection and enter the address of the DN2 to connect to.
DN2 Manager connected
Once connected to the DN2 node, the manager should look similar to this.
Any installed cards will be shown.(BPU/EBPU or PIA are not shown)
Synchronization
To check/set synchronization select the synchronization button.
The synchronization window will open.
Here you can set the priority list for the timing sources.
Send to Node
Any changes made to settings within the DN2 Node Manager must be sent to the Node for the settings to come into effect.
This is done using the ‘Send to Node’ button.
Until this is done the settings are only be stored in the Node Manager.
Port Settings
To check/set IU2 Port setting select the ‘Ports view’ button or ‘Configure…Ports view’ via the menu bar.
The settings for all IU2 ports that are installed will be displayed.
Double click inside a ports column to change settings.
Changing Port settings
From this window the setting for the individual port can be set.The interface can be brought in/out of use and any TS0 settings for embedded management or Loop synchronization set.
Questions?
Select a Table to add cross connects
To add/view cross connects we need to select a Table to edit.
Open the ‘Connection Tables view’.
To make the cross connects part of the live network then the ‘Activated’ table must be edited. Double click on the table to edit
Cross connects ‘Connections View’
The cross connects for that table will be displayed in a list.
Cross connects ‘Graphical View’
A graphical view of the cross connects can be seen by selecting the ‘Graphical connections view’ button
Adding cross connects
A new cross connect is done by selecting the button for the type of cross connect you wish to set. B C D Y
B Type Cross Connect
The B type cross connect window.
The Connection Point window
Y2M Type Cross Connect
A Y2M connection is used when setting protected routes for circuits.
Conditions are set to decide on how the active link is decided
C Type Cross Connect
The C type cross connect window.
C0 = Point to multipointC2 = Multipoint to multipoint
Alarms
By selecting the ‘Alarms view’ button a list of any alarms on the DN2 will be displayed, including those of any Dynacards that are installed.
‘Save as’ function
The ‘Save as’ function is used to save cross-connect/port settings made on the DN2 and allows Off-line configuration with the node manager.
Open a saved configuration file
To open a previously saved configuration select the ‘Open’ button and select the ‘.dn2’ file for the saved node.
Off-line Configuration
‘File Connection’ displays in the manager window and the cursor displays ‘file’ to show that you are configuring from file.
Backup the DN2 Node
The backup facility allows us to save the complete configuration of the DN2 node (including Dynacard settings) and restore it to a new or repaired node in a catastrophic incident.
Restore the DN2 Node
The Restore facility allows us to restore the complete configuration of a DN2 node to a new or repaired node.
Questions?
DN2 Y Branching
Y-Branch-Order Of Events-DN2 A•Allocate A-End Port And Time Slot For VF Circuit (Site A)
•Choose Primary Route Port And Time Slot
•Choose Secondary Route Port And Time Slot
•Set Conditions on Primary Route (2 Conditions Must be Set)
•Set Masks (If Required…These give full control)
•Repeat All Of the above for DN2 B (Site B)
VF A End
DN2 A
VF B End
DN2 B
Port 1 TS=1
=Primary Route
=Secondary Route
Port 1 TS=1
Primary Route Port 2 TS=1
Condition 2 and 3
Secondary Route Port 3 TS=1Secondary Route Port 3 TS=1
Primary Route Port 2 TS=1
Condition 2 and 3
Topology
Xxxxxxxx-xx0x
Xxxxxxxx-xx0x
Mask
Mask
DN2 Site A
Conditions & Masks Conditions & Masks
Port & TS Port & TSPrimary Route
Protecting Route
DN2 Site A-Conditions
DN2 Site A
VF A-End
DN2 A
VF B End
DN2 B
Port 1 TS=1Port 1 TS=1
Primary Route Failure
•At DN2 A and DN2 B------Bit C = xx1x, Due to Loss of 2 Meg(Failure,Condition3)
•As the condition 3 has been Met, The circuit Is Switched to the Secondary Route !
xTraffic Flow
Port 2 TS=1
Port 3 TS=1
Port 2 TS=1
Port 3 TS=1
VF A-End
DN2 A
VF B-End
DN2 A
Port 1 TS=1Port 1 TS=1
Revert to Normal Operation
•Once Primary Port Comes Back into Normal Operation, Bit c will once again be 1000 (abcd)
•This will satisfy condition 2 and therefore circuit will switch back to the Primary Route.
Traffic Flow
Port 2 TS=1
Port 3 TS=1
Port 2 TS=1
Port 3 TS=1
Questions?