1 DataLink Technologies Gateways, Inc. www.datalink-gateways.com (360) 306-5878 / (866) 709-6390 DL-GW1000-DH485-ABEIP CompactLogix/ControlLogix/MicroLogix Ethernet/IP to DH485 Setup This application note provides an example of setting up of a MSG block from CompactLogix Ethernet/IP to DH485 using node 5 (PLC5/20) through DL-GW1000-DH485-ABEIP at 192.168.1.222 The DL-GW1000 is our latest platform combining the DL3500, DL4500, and DL7000 functionality with our enhanced Ethernet technology. Additional information is available in the DL-GW1000 User Manual at www.datalink-gateways.com or contact our Technical Support at (360) 306-5878 / (866) 709-6390. As explained in the product manual, setup is accomplished through a webscreen interface. Visit the default IP address for the GW1000 at 192.168.1.111. Login is “root”, password is “Netsilicon”.
6

DL-GW1000-DH485-ABEIP … fileFollowing are screens showing RSLINX through DH485 link through the GW1000-DH485-ABEIP. Please note you must force the network type to DH485. Also, ...

May 09, 2019

Download

Documents

vuongbao
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: DL-GW1000-DH485-ABEIP … fileFollowing are screens showing RSLINX through DH485 link through the GW1000-DH485-ABEIP. Please note you must force the network type to DH485. Also, ...

1 DataLink Technologies Gateways, Inc. www.datalink-gateways.com (360) 306-5878 / (866) 709-6390

DL-GW1000-DH485-ABEIP CompactLogix/ControlLogix/MicroLogix Ethernet/IP to DH485 Setup This application note provides an example of setting up of a MSG block from CompactLogix Ethernet/IP to DH485 using node 5 (PLC5/20) through DL-GW1000-DH485-ABEIP at 192.168.1.222

The DL-GW1000 is our latest platform combining the DL3500, DL4500, and DL7000 functionality with our enhanced Ethernet technology.

Additional information is available in the DL-GW1000 User Manual at www.datalink-gateways.com or contact our Technical Support at (360) 306-5878 / (866) 709-6390.

As explained in the product manual, setup is accomplished through a webscreen interface. Visit the default IP address for the GW1000 at 192.168.1.111. Login is “root”, password is “Netsilicon”.

Page 2: DL-GW1000-DH485-ABEIP … fileFollowing are screens showing RSLINX through DH485 link through the GW1000-DH485-ABEIP. Please note you must force the network type to DH485. Also, ...

2 DataLink Technologies Gateways, Inc. www.datalink-gateways.com (360) 306-5878 / (866) 709-6390

This example shows setup with a Compactlogix communicating through the GW1000-ABEIP-DH485 to a SLC 5/05 channel 0. The following screen shows the CompactLogix tags present and the SLC5/05 DH-485 configuration.

Page 3: DL-GW1000-DH485-ABEIP … fileFollowing are screens showing RSLINX through DH485 link through the GW1000-DH485-ABEIP. Please note you must force the network type to DH485. Also, ...

3 DataLink Technologies Gateways, Inc. www.datalink-gateways.com (360) 306-5878 / (866) 709-6390

The next screen shows the configuration of the Message instruction in the Compactlogix for the tag L55_to_PLC5 tag. In our example, the GW1000 is at IP address 192.168.1.222.

Page 4: DL-GW1000-DH485-ABEIP … fileFollowing are screens showing RSLINX through DH485 link through the GW1000-DH485-ABEIP. Please note you must force the network type to DH485. Also, ...

4 DataLink Technologies Gateways, Inc. www.datalink-gateways.com (360) 306-5878 / (866) 709-6390

Page 5: DL-GW1000-DH485-ABEIP … fileFollowing are screens showing RSLINX through DH485 link through the GW1000-DH485-ABEIP. Please note you must force the network type to DH485. Also, ...

5 DataLink Technologies Gateways, Inc. www.datalink-gateways.com (360) 306-5878 / (866) 709-6390

Following are screens showing RSLINX through DH485 link through the GW1000-DH485-ABEIP. Please note you must force the network type to DH485. Also, the station mapping table shows node addresses in DECIMAL, not OCTAL. The word “Driver” should be beside the node address of the GW1000. Other nodes should have the IP address of the GW1000.

Page 6: DL-GW1000-DH485-ABEIP … fileFollowing are screens showing RSLINX through DH485 link through the GW1000-DH485-ABEIP. Please note you must force the network type to DH485. Also, ...

6 DataLink Technologies Gateways, Inc. www.datalink-gateways.com (360) 306-5878 / (866) 709-6390