www.avea.cc RFID RS232 / RS485 Computer Based Access Control System DIY Computer based cost effective solutions for access control with Time Recorder KS232DU KS485DU KS485DF KS232DF Quick Start: 1. For KS232D series products - connect the RS232 cable (straight through) from the computer to the terminal block of RS232 port. (See Terminal Layout) For KS485D series products - plug the TINY485 (buy separately) into the serial port of the computer. Connect the TINY485 to the RS485 data bus of the reader. (See Terminal Layout) 2. Connect a 9 to 12VDC supply to the terminal block of 9-12V 300mA. 3. Turn on the computer. 4. Download and install the Time Recorder software from . http://avea.cc/sw/TR.zip 5. Save and unzip the file. 6. Execute the setup.exe program. 7. Follow the installation instruction to finish the installation. 8.The detailed installation manual for the Time Recorder will be automatically installed into your computer when you install the application software. Follow the installation instruction to finish the installation and follow the Installation Manual of Time Recorder User manual : http://avea.cc/spec/ks232dfu.pdf http://avea.cc/sw/TR.zip Download Time Recorder software : *** Always remember to before plugging or unplugging wires POWER OFF Re: KS232DFU/20150930/MADE IN CHINA www.avea.cc Link for SETUP: KS232DU : http://avea.cc/ks232du-setup/ KS232DF : http://avea.cc/ks232df-setup/ KS485DF : http://avea.cc/ks232df-setup/
4
Embed
DIYComputer Based Access Control System RFID RS232 / RS485 · RFID RS232 / RS485 DIY Computer Based Access Control System Computer based cost effective solutions for access control
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
www.avea.cc
RFID RS232 / RS485Computer Based Access Control SystemDIY
Computer based cost effective solutions for access control
with Time Recorder
KS232DU KS485DU KS485DFKS232DF
Quick Start:
1. For KS232D series products - connect the RS232 cable (straight through) from the computer to the terminal block of RS232 port. (See Terminal Layout)
For KS485D series products - plug the TINY485 (buy separately) into the serial port of the computer. Connect the TINY485 to the RS485 data bus of the reader. (See Terminal Layout)
2. Connect a 9 to 12VDC supply to the terminal block of 9-12V 300mA.3. Turn on the computer.4. Download and install the Time Recorder software from .http://avea.cc/sw/TR.zip5. Save and unzip the file.6. Execute the setup.exe program.7. Follow the installation instruction to finish the installation.8.The detailed installation manual for the Time Recorder will be automatically installed
into your computer when you install the application software. Follow the installation instruction to finish the installation and follow the Installation Manual of Time Recorder
User manual : http://avea.cc/spec/ks232dfu.pdf http://avea.cc/sw/TR.zipDownload Time Recorder software :
*** Always remember to before plugging or unplugging wiresPOWER OFF
Re: KS232DFU/20150930/MADE IN CHINA Page 1www.avea.cc
Link for SETUP:KS232DU : http://avea.cc/ks232du-setup/KS232DF : http://avea.cc/ks232df-setup/
KS485DF : http://avea.cc/ks232df-setup/
Time Recorder Quick Start
PHOTO(Card Information)
LIVE VIDEO(from PC Camera)
PICTURE(Captured by PC Camera
while user presentingthe ID card to the reader)
1. Setup the RFID Readers2. Setup the EMAIL Settings3. Webcam Setup
4. Present the ID cards to the reader.5. Double click the record to enter Card Information. Or, Edit Card Information in Setup6. Start and enjoy the Time Recorder.
For details, please check the Installation Manual oremail us at [email protected] for support.
INDICATION RED LED GREEN LED BUZZER LOCK
Stand by mode – waiting for instruction Blink
Action: Present a card to the reader
The reader is not connected to the computer ON
ID card with NO Card Information ON ON
ID card with Card Information ON ON ON
ID card with Card Information and access allowed ON ON ON RELEASE
LED and Buzzer Indication
Re: KS232DFU/20150930/MADE IN CHINA Page 1www.avea.cc
KS232DU / KS485DU / KS232DF / KS485DFRFID Computer Access Controller and Time Recorder
INTRODUCTION
The KS232DU / KS485DU / KS232DF and KS485DF proximity readers are cost effective solutions for access control and time recording solutions. While connecting them to the computer and running the Time Recorder software (in Windows), the program will stamp the date, time and card ID into the computer database, show up the associated picture with the specific ID on the computer screen, capture the photo if a PC camera is connected to the computer and release the electric lock if allow access.
A 9 to 12V DC supply is required to power the reader, which has a current consumption of less than 300mA.
TERMINAL LAYOUT
MODEL KS485DU
OPEN SW
GND(BYPASS SWITCH)
DC OUT
GND
DC IN
GND
(TO ELECTRIC LOCK)
(9-12V 300mA)
(RELAY)(RELAY)
KS
48
5D
U
RS485 DATA BUS
ENABLE TERMINATOR
NORMAL OPENCOMMON
NORMAL CLOSE
MODEL KS232DF
NORMAL CLOSE
NORMAL OPENCOMMON
OPEN SWGND
(TO ELECTRIC LOCK)
(9-12V 300mA)
(BYPASS SWITCH)
(RELAY)
DC OUTGND
DC INGND
RS232 PORT
DATA TO PC - DB9 PIN 2DATA FROM PC - DB9 PIN 3
GND - DB9 PIN 5
(TO COMPUTER)
ACTIVE WHEN TRANSMITNOT USED
NO
T U
SE
D
NOT USED
Power supply
negative terminalPower supply
positive terminal
OPEN SW
GND(BYPASS SWITCH)
NORMAL OPENCOMMON
DC OUT
GND
DC IN (positive)GND (negative)
(TO ELECTRIC LOCK)
NORMAL CLOSE(RELAY)
DATA TO PC - DB9 PIN 2
DATA FROM PC - DB9 PIN 3GDN - DB9 PIN 5
ACTIVE WHEN TRANSMITNOT USED
***Jumper setupfor RS232 mode
NOT USED
RS232 PORT
(TO POWER:9-12V 300mA)
MODEL KS232DU
NOT USED
NO
T U
SE
D
NORMAL CLOSE
NORMAL OPEN
COMMON
OPEN SW
GND
(TO ELECTRIC LOCK)
(9-12V 300mA)
(BYPASS SWITCH)
(RELAY)
DC OUT
GND
DC IN
D-D+
(RS485 DATA BUS)
ENABLE TERMINATOR
Power supply
negative terminal
Power supply
positive terminal
GND
NO
T U
SE
D
MODEL KS485DF
NOT USED
NO
T U
SE
D
Re: KS232DFU/20150930/MADE IN CHINA Page 1www.avea.cc
Six mounting holes of diameter 4mm
KS232DF and KS485DF Dimensions:
116.5mm 21mm
23mm
Front View Rear ViewSide View
Lock power
Lock power
Bypassswitch
Electro-magneticlock
N.O.(NORMAL OPEN)
Lock power
Lock power
Bypassswitch
C(COMMON)
C(COMMON)
N.C.(NORMAL CLOSE)
ElectricStrike
LOCK CONNECTION:
One mounting holes of diameter 5mm
60
mm
Three mounting holes of diameter 4mm86mm
Front View Rear ViewSide View
10mm 30mm
86
mm
KS232DU and KS485DU Dimensions:
Re: KS232DFU/20150930/MADE IN CHINA Page 1www.avea.cc