30. DIVERTER
30.1 FUNCTION
- Description
The Diverter is installed on the conductor pipe before drilling of first phase of the well and isdesigned to keep
personnel and Rig safe.It consist of an annular type blow out preventer and is designed to divert shallow gas away
fromthe well area while drilling surface hole.In doing so, the well remains open but diverting the pressure avoids
fracturing a formation.
- Manufacture specifications
Diverter system are manufactured according to API 16A and RP 64.The relevant ISO standard is the 13533 Spec.EN
requirements are defined by "Well control policy" and an internal specification.
30.2 TYPICAL CONFIGURATION
- Off-shore application (APIRP 64) Schematic arrangement foran off-shore application, asper API RP 64
recommendations.
- Hydril's suggested configurations
8/13/2019 Diverter
2/9
11/25/13 DIVERTER
apirigroup.com/diverter.html
- Hydril example with SXVspool arrangement
This integral type spoolwith diverter has theadvantage of remotecontrols, eliminating theuse of lateral valves.
8/13/2019 Diverter
3/9
11/25/13 DIVERTER
apirigroup.com/diverter.html
- SXV MSP Engineering Data
8/13/2019 Diverter
4/9
11/25/13 DIVERTER
apirigroup.com/diverter.html
-Typical configurationon Saipem's Rigs
Typical configurationon Saipem's mediumand high power Rigs
8/13/2019 Diverter
5/9
11/25/13 DIVERTER
apirigroup.com/diverter.html
- Diverter Installations
- Diverter valve
8/13/2019 Diverter
6/9
11/25/13 DIVERTER
apirigroup.com/diverter.html
30.3 TYPES AND CHARACTERISTICS
- Hydril MSP
The 29 " Diverter is the most commonlyused.It allows the running of 27" bit.For fast moving type Rigs, uses the
20"annular BOPThe MSP 29-1/2"-500 requires onlyclosing pressure. Seal off is effected by hydraulicpressureapplied to the closing chamber whichraises the piston, moving the packing unit radially inward into a sealing
engagement. Any normal closing unit having aseparate regulator valve for the annular BOP and sufficient accumulator
volumecan be used to operate the MSP.
8/13/2019 Diverter
7/9
11/25/13 DIVERTER
apirigroup.com/diverter.html
- Table Data
8/13/2019 Diverter
8/9
11/25/13 DIVERTER
apirigroup.com/diverter.html
- Table Initial Closing Pressure (psi)
Required for MSP 29-1/2-500 BOP / DIVERTER
Closing Pressure 500 PSI Wellbore
12" ipe 5" Pipe CSO
959 psi 1350 psi 1500 psi
30.4 INSPECTIONS
The Diverter System shall be inspected (modally and frequency) according to the manufacturer'srecommendations
and as per API RP 53.ENI requirements are defined by an internal specification.