Page 1: District Cooling   Jenny Dahlberg, Fortum

1

Sustainable energy to rely on

Jenny Dahlberg Fortum

Page 2: District Cooling   Jenny Dahlberg, Fortum

2

Fortum- your energy partner

Fortum is a leading energy company with 14 000 employees focusing on the Nordic countries, Russia and the Baltic Rim area.

Position in the nordic market

# 1 Distribution# 1 District heating# 1 District cooling# 1 Electricity sales# 2 Power generation

Page 3: District Cooling   Jenny Dahlberg, Fortum

3

Fortum has one of the lowest CO2 emissons in Europe

Källa: PWC och Enerpresse 2005

Els

am

0

200

400

600

800

1,000

1,200D

EI

Dra

x

RW

E

Ene

rgi E

2

ED

P

Uni

on F

eno

sa

CE

Z

Edi

son

End

esa

Sco

ttis

h&

Sou

the

rnE

ssen

t

EN

EL

E.O

N

Vat

tenf

all

Ele

ctra

bel

PV

O

Iber

dro

la

Ver

bun

d

Fo

rtu

m

Brit

ish

Ene

rgy

ED

F

Sta

tkra

ft

CO2 emissions – European companies

g/kWh

Page 4: District Cooling   Jenny Dahlberg, Fortum

4

Electricity distribution

The power supply in the Stockholm area consists of a 220 kV ring structure, owned by Fortum

Five primary substations Fortum is capable of delivering 220-33 kV system voltage all

around StockholmFortum can supply the electricity with redundancy from local

elctricity production

Page 5: District Cooling   Jenny Dahlberg, Fortum

Procurement of electricity

• Physical delivery of electricity – used in your daily operation

–Price risk

–Volume risk (operational)

–Political risk

• Financial hedging of purchase price – to secure your business result

–Customise purchasing and portfolio strategy

–Customise risk manual according to risk policy

–Trade with physical and financial contracts

Page 6: District Cooling   Jenny Dahlberg, Fortum

Guaranties of origin from renewable energy sources

Certificate system

RES Supply RES Demand

Issuingbody Issuing Registration Redeeming

Electricity Market (NordPool)

Certificate market

Auditor

Page 7: District Cooling   Jenny Dahlberg, Fortum

7

District heating - an environmental success story

Fortum's reduced emissions in Stockholm since 1980:

-60 % of CO2 >95 % of SO2 >80 % of NOx

70 % renewable fuels

Page 8: District Cooling   Jenny Dahlberg, Fortum

88

District heating

For Data centers the need for heating is minimal and Fortum can, instead, buy surplus heat from the centers

Page 9: District Cooling   Jenny Dahlberg, Fortum

9

District cooling in Stockholm - largest in Europe

570 points of deliveries350 MW capacity400 GWh production/year170 GWh sept-april deliveries from 8 kW to 11 MW

Page 10: District Cooling   Jenny Dahlberg, Fortum

10

District cooling- This is how it works

1

2 3

4

1. Cold water from the bottom of the sea is used to cool down the DC (district cooling) water that circulates in a closed loop. The sea water is then returned to the sea.

2. The heat in the warmer water in the DC return pipe can be recovered to the DH system via heat pumps. By this simultaneous heating and cooling all energy in the cooling system will be recovered.

3. During the nights when there is excess capacity from free or waste cooling production the storage is used. 4. The low temperature in the DC system is transferred to the internal system in the connected buildings.

The internal systems are then distributing the cooling capacity within the buildings.

Page 11: District Cooling   Jenny Dahlberg, Fortum

11

Why District cooling?

Low intitial investment cost ( -75 %)Minimal operation and maintenance costs ( -90 %) Reduces the electricity consumtion (- 95%)Reduces the need of cooling water (-100 %)Reduces the space needed for installationsRealiable delivery - availibility of 99,7% Low financial risk- up to ten year individual contractDistrict cooling is climate neutral - increases the environmental

profile of the facility

Page 12: District Cooling   Jenny Dahlberg, Fortum

12

Clients with critical cooling needs

In Kista, the "Silicon Valley of Sweden" - approx. 60 % of all district

cooling energy is used for server halls.

Approx. 50 % of all district cooling clients in Stockholm also use

district cooling for local server halls in office buildings.

Other examples of clients:DNEX - printing plantStockholm Globe Arenas - concert arenas for up to 44 000 visitorsTV4 - television production & broadcasting companyStockholm International Fair - 70 000 sq.m of exhibition areaKarolinska Institutet - medical lab

Page 13: District Cooling   Jenny Dahlberg, Fortum

13

District cooling - Still growing

• Expansion driven by client demands. The distribution net expands with growing need för capacity. The production is increased with minimum affect on the environment.

• Fortum Värme has the knowledge and technique to build new production sites and distribution system if there is a increased demand in the market.

• The choice of method of production depends on local conditions

Page 14: District Cooling   Jenny Dahlberg, Fortum

14

Current project - cold water storage in Hornsberg

To increase the capacity in Stockholm, a 40 000 m3

cold water storage is being built. It will be taken in operation in november 2009 and used as a day and night storage.

Page 15: District Cooling   Jenny Dahlberg, Fortum

15

IBM and Fortum, a fruitful collaboration

IBM and Fortum has a long relationship.

In Kista, IBM has sold surplus heat, from their data center, to Fortum since 1997. Together we can make use of energy that would otherwise be wasted.

In 2008, district cooling was installed at the IBM data center

Page 16: District Cooling   Jenny Dahlberg, Fortum

16

IBM - thinking green

Since 1967, IBM has had a corporate policy of protecting the environment and conserving energy

1997, IBM became the world's first major multinational to have earned a single worldwide registration to the ISO 14001 Environmental Management System (EMS) standard.

Page 17: District Cooling   Jenny Dahlberg, Fortum

17

IBM Chosing district cooling- questions

A choice of technique not previously known to the owners- IBM in Sweden, together with Fortum informed about the simplicity and reliability of the technique

How would the maintenance time be affected?-The maintenance time will be reduced due to less complicated technique

How reliable is district cooling?- Fortum guarantees full delivery of district cooling 99,7% of the year. If a shut down is necessary, Fortum have a dialog with the client.Back up systems are needed though, as with all types of cooling.

Page 18: District Cooling   Jenny Dahlberg, Fortum

18

IBM Chosing district cooling

The main reasons for IBM to chose district cooling were:

environmental issues less maintenancebetter economy

Page 19: District Cooling   Jenny Dahlberg, Fortum

19

Cooling and heating - make it climate neutral today

District cooling from Fortum is climate neutral todayFortum´s vision is to also have a climate neutral production of

district heating in 2020 In the mean time - customers can purchase climate neutralisation

of their use of district heatingFor the percentage of production that is not climate neutral today,

we compensate with CDM-projects.CDM - Clean Delevopment Mechanism is CO2 - reducing projects

defined by the Kyoto Protocol and the Framework Convention on Climate Change

CDM - projects are made in countries that lack a sustainable energy solution.

Page 20: District Cooling   Jenny Dahlberg, Fortum

20

Conclusion

Fortum - your energy partner for data centers

Electricity distribution Procurement of electricity Procurement of certificates for renewable electricity District heating District cooling Purchasing of surplus heat

Making your data center climate neutral