Railway Electrification AC/DC SWITCHES MV/HV Equipment DISCONNECTOR SWITCHES EARTHING SWITCHES LOAD BREAK SWITCHES OPERATING MECHANISMS CONTROL & MONITORING
Jun 16, 2020
Railway ElectrificationAC/DC SWITCHESMV/HV Equipment
DISCONNECTOR SWITCHES
EARTHING SWITCHES
LOAD BREAK SWITCHES
OPERATING MECHANISMS
CONTROL & MONITORING
SDCEM PRESENTATION
RAILWAY ELECTRIFICATION SOLUTIONS
SDCEM KEY PROJECTS
SDCEM SERVICES
SELECTION GUIDE
PRODUCT PORTFOLIO
DISCONNECTOR SWITCHES
EARTHING SWITCHES
LOAD BREAK SWITCHES
OPERATING DRIVES / FLEXBALL
CONTROL & MONITORING
TABLE OF CONTENTS
A
B
C
D
E
F
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
SR16200 OUTDOOR CENTER BREAK SR16201H OUTDOOR DOUBLE BREAK SBE OUTDOOR VERTICAL BREAK SBI INDOOR VERTICAL BREAKSBR OUTDOOR ROCKING SR16203N OUTDOOR SIDE BREAKSST25 INDOOR DOUBLE BREAK OVB OUTDOOR CHANGE-OVER SWITCHCC21155 OUTDOOR FUSE HOLDER
ST36001 OUTDOOR EARTHING SWITCHSTE OUTDOOR EARTHING SWITCH
IT3000 OUTDOOR AIR BREAKING SWITCHIT3600 OUTDOOR AIR BREAKING SWITCHITC4000 OUTDOOR AIR BREAKING SWITCHIT25 OUTDOOR VACUUM BREAKING SWITCHITR OUTDOOR VACUUM BREAKING SWITCH
MR41E UNIVERSAL SMART DRIVEMR164E UNIVERSAL SMART DRIVER77E MANUAL OPERATING DRIVET70 MANUAL OPERATING DRIVEFLEXBALL FLEXIBLE TRANSMISSION
S-COM REMOTE CONTROL BOARDS-TORQUE TORQUE & POSITION MONITORINGS-VOLT VOLTAGE DETECTOR FOR RAILWAY DS / LBSS-OFT PORTABLE DIAGNOSTIC TOOLS-LUX LIGHT ALARM / INFORMATION STATUS
More than
68 000product references VHV & HV & MV from 12.5 kV to 550 kV in 140 countries.
Products and services approved by major customers and key utilities worldwide:EDF, Infrabel, Network Rail, National Grid of Saudi Arabia, ONCF, RTE, SNCF, State Grid Corporation of China…
TRUE COMPREHENSIVE SOLUTIONSFOR SWITCHING & DISCONNECTING
SDCEM is a historical and worldwide recognized brand for performance and high value. Since 1947, SDCEM has developed a renowned know-how in designing and manufacturing of switching solutions, offering the widest range of Medium Voltage (MV), High Voltage (HV) & Very High Voltage (VHV) disconnectors & switches, and associated services to fit end users’ needs.
Strongly focused on excellence, we are aiming to be the reference partner for all stakeholders on 3 main activities: Railway electrification, Transmission & Distribution and Power Generation market.
Our challenge is to design and manufacture switching solutions for tomorrow: more safety, more reliability, more flexibility, longer lifecycle (up to 50 years), and lower operation and maintenance costs.
Our goal is to introduce more intelligence for installation, operation and maintenance, and more communication to increase electrical network performance, thanks to our equipment designed and manufactured at the cutting edge of technology.
Our expertise is the true assurance of high performance equipment.
This is the key for the future electrical networks: get the best from each component.It will be also the key of our future joint successes.
QUALITY INNOVATION & DESIGN CUSTOMER PROXIMITY
SD
CEM
PR
ESEN
TATI
ON
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com A
RA
ILW
AY
ELE
CTR
IFIC
ATI
ON
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com B
RAILWAY AT A GLANCEFIELD OF APPLICATION
DC Electrification Urban (metro, tramways) & suburban trains750 VDC / 1500 VDC France, China, Brasil, Mexico, Egypt, Algeria, Australia, …3000 VDC Belgium, Morocco, Spain, …
AC Electrification High speed line, conventional (long distance)15 kVAC Germany, Austria, …25 kVAC France (V160, V200 or V350) , UK (Series 2), China, Spain, Turkey, Italy, …
TRACTION SUBSTATION From 52 to 245 kVAC, SDCEM provides all type of disconnectors and earting switches.
CATENARY / FEEDER / TUNNELSDCEM manufactures disconnectors, load break switches, earthing switches, fuses holders for the following applications:
We propose the largest range of switches for railways electrification: more than 20 types of switches in 5 products categories (off-load / on-load / earthing / fuse holders).
SDCEM products are qualified by the most renowned railways network operators (France, Spain, China, Germany, UK, …)
With references in railway in more than 35 countries of 4 continents, SDCEM installed 22 000 products since 70 years.
We have a deep knowledge and understanding of project challenges for all type of catenary (SNCF - France V350 high speed lines, Network Rail - UK Series 2, ADIF, TCDD, …) and traction substation layouts (AC and DC).
We bring comprehensive solutions to our customers, bringing our experience in HV switches, operating mechanisms and transmissions.
SDCEM switches are SMART GRID READY: we add monitoring and communication to switching devices, increasing electrified network safety and reliability, and enabling a cost effective operation & maintenance.
WHERE WE ARE
OUR EXPERTISESDCEM is a world specialist for disconnector design and manufacturing for AC and DC railways networks.
RA
ILW
AY
ELE
CTR
IFIC
ATI
ON
RAILWAY AT A GLANCEPRODUCT RANGE
B
RA
ILW
AY
ELE
CTR
IFIC
ATI
ON
UNIVERSAL SMART DRIVES
SUBSTATIONHV DISCONNECTORS
DISCONNECTORS FOR FEEDER /
CATENARY
HV DISCONNECTORS LOAD BREAK SWITCHES
RA
ILW
AY
ELE
CTR
IFIC
ATI
ON
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com B
RAILWAY AT A GLANCEINSTALLATION OPTIONS
HV SWITCHDisconnector Switches, Load Break Switches or Earthing SwitchesArrangement in horizontal or vertical position, or back-to-back position, single-pole or group operated. Used for catenaries, feeders, substations and tunnels.
TRANSMISSIONRigid or FlexibleTransmission system carry the movement of the operating drive. The flexible transmission (Flexball) perfectly suits tunnel wall and complex installations.
OPERATING MECHANISMUniversal Smart Drives or Manual DrivesOperating drives operates MV/HV disconnectors and switches. Either manual or electric with emergency operating, drives must be chosen according to the specific constrains linked with each application: type of use, site conditions, etc.
CONTROL & MONITORINGHard Copper Wires, Fiber Optic, Analogic or Digital Control (MODBUS, IEC 61850), Torque Monitoring, Voltage DetectorControl & Monitoring solutions are IED equipped, plug and play and universal. Compatible with all equipment, they only need a Universal Smart Drive (MR41E or MR164E).
SCADA
RA
ILW
AY
ELE
CTR
IFIC
ATI
ON
Responding to the highest technical requirements worldwide, SDCEM products are reliable and robust products. SDCEM adapt standard products to numerous configurations and options for various and harsh environment:
• Cold climate: up to -40° C as for Kazakhstan, north of China (Harbin - Dalian railway) • Hot climate: more than 50° C as in Algeria or in Saudi Arabia (more than 100 substations and SVC equipped with SDCEM products). • Humid atmosphere: Brasil, Myanmar, India,.. • Seashore environement: France, UK,...
With in house design, manufacturing and testing facilities, we continuously improved with our worldwide experience, high quality of HV components manufacturing and equipment performances.
SDCEM is a partner of major worldwide projects:
SD
CEM
KEY
PR
OJE
CTS
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
SDCEM KEY PROJECTSEXPERIENCES AND REFERENCES
SDCEM is renowned by end-users for its equipment quality and robust design, and full compliance to international IEC and EN standards (IEC 62505, IEC 61992, IEC 624971-1/-102, EN 50123, IEC 61850). SDCEM solutions are approved by many railway companies around the world with several homologations:
LVG Est HSRWORLD FATEST TRAIN
574 km/h
Guiyang–Guangzhou HSRWORLD LONGEST LINE
856 km
Tanger - Casablanca HSRFIRST AFRICAN HIGH-SPEED LINE
2018
Haramain HSRFIRST MIDDLE-EAST HIGH-SPEED LINE
2018
Channel TunnelCONNECTING UK - FRANCE
50.5 km
Marmaray TunnelCONNECTING EUROPE - ASIA
13.6 km
C
SD
CEM
KEY
PR
OJE
CTS
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com C
SDCEM KEY PROJECTSHIGH SPEED, CONVENTIONAL AND SUBURBAN LINES
Since 1947, SDCEM has successfully contributed to the development of high speed lines, conventional lines and suburban lines worldwide by having supplied disconnectors and switches.
Haramain High-Speed LineCATENARIES & SUBSTATIONSThe 450 km long railway network is Saudi Arabia’s first high-speed inter-city line connecting Makkah to Madinah in 2h 52min with its train achieving speed of more than 300km/h.
SDCEM equipment is design to suit to the environmental constraints such as Saudi Arabia’s extremely sandy and hot environment (more than 50°C). SDCEM provided disconnec-tor switches for the line’s catenaries and substations and electrical universal smart drives to operate disconnectors.
Substations• 3 Single Pole Side Break DS SR16203N • 108 Double Poles Side Break DS SR16203N• 111 Universal Smart Drives MR41E
Catenaries (Overhead lines)• 10 Single pole vertical break DS SBE • 338 Rocking DS SBR • 348 Electrical Universal Smart Drives MR41E
São Paulo Metro Line 5 Extension URBAN & TUNNELThe line expansion improves the mobility of public transport users in the Capão Redondo-Largo Treze Chácara Klabin cor-ridor. It involves the construction of 11 km of twin tunnels.
SDCEM provided indoor disconnectors for tunnels with smart grid solutions to control and monitor SDCEM disconnectors: S-VOLT. It allows completely safe maintenance to be proceeded, including safety fuses & earth fault relay. With the flexible rod, our products are designed to fit tunnels and urban installations‘ requirements.
Disconnectors Switches• 8 Vertical Break DS SBE• 17 Vertical Break DS SBI• 2 Disconnectors Cubicles
Control & Monitoring• 25 Electrical Universal Smart Drives MR41E• 13 Flexible rod for tunnel• 25 S-VOLT + S-LUX
SD
CEM
KEY
PR
OJE
CTS
SD
CEM
KEY
PR
OJE
CTS
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com C
SDCEM KEY PROJECTSHIGH SPEED, CONVENTIONAL AND SUBURBAN LINES
Marmaray Railway Engineering ProjectTRACTION SUBSTATIONSThe Marmaray Project represents the first physicalrail link between Europe and Asia. It connectsIstanbul’s Asian and European sides through a 76.3 km subway-type railway tunnel under the Bosphorus strait.
The project includes upgrading the 63 km lines of commuter train and the 13.6 km submarine rail tunnel with two tracks under the Bosphorus.
SDCEM provided disconnector switches, load break switches and control & monitoring solutions to EYM Instalaciones for the substation traction project.
Disconnectors Switches• 98 Outdoor Rocking DS SBR 52kV 2500A • 14 Vertical Break DS SBE 52kV 1250A in cubicles
Load Break Switches• 8 IT25 52kV 2000A (Earthing Switches)
Double-Track High-Speed Railway Line Tithorea-DomokosURBAN & TUNNELThe Tithorea-Domokos Line is a 106 km long line located in central Greece aiming to replace the mountainous section of the existing single-track line. The new alignment is designed for train speeds of 160-200 km/h and is expected to reduce travel time between Athens and Thessaloniki line down to 3.5 hours.
SDCEM provided load break switches designed to be installed in substations alongside the double rail line in 2017.
Load Break Switches• 67 Vacuum Breaking Switches IT25
Control & Monitoring• 67 Electrical Universal Smart Drives MR41E
Control & Monitoring• 40 Manual Operating Drives T70• 81 Universal Smart Drives MR41E with S-COM Modbus RTU protocol and optic fiber connection
SDCEM SERVICESA DEDICATED TEAM TO PROVIDE THE HIGHEST CARE
SD
CEM
SER
VIC
ES
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com D
Disconnectors and switches are essential security equipment which requires the highest care.
From project design through disconnectors installation to after sales services, SDCEM SERVICES provide worldwide sustainable services for maintenance of HV/MV equipment to maintain installations reliable and efficient throughout equipment’s service life:
MATERIAL• Set & spare parts for repairing disconnector• Rehabilitation and replacement of equipment• Retrofit and upgrade equipment• Interchangeability or disconnect remotorization• Adaptation kits for “old brand” equipment (Soulé, Merlin Gerin..)• Switch disconnectors additional equipment
SERVICES• Technical assistance services• Onsite expertise from assembly to maintenance• Training and supervision• Preconization of spare parts, equipment retrofit• On-site measurement and recommendation of most adapted solution• Monitoring and diagnostics of disconnectors
INSTALLAssembly, installation, adjustement, commisionning, supervision
TRAIN & MAINTAINStandard & advanced maintenance,repair service, training on site or in factory, equipment troubleshooting
REMOTORIZATIONMotorization or re-motorization, additional
equipment, damaged disconnectors repairing
MONITOR & OPTIMIZEDiagnostic & recommendations, condition-based main-tenance, real-time condition monitoring, self-diagnosis equipment supply
UPGRADE & RETROFITTechnical consulting, risk manage-ment recommendations, upgrade
performances & retrofit of equipment
RAILWAY ELECTRIFICATION - SELECTION GUIDE
FP129c - 2017 SDCEM - 10 allée des Plantées, 38450 VIF, FRANCE - [email protected] - + 33 (0)4 76 72 76 72 - www.sdcem.com This document is subject to change without notice.
SHORT-CIRCUIT
EARTHING DEVICES
Max
imum
sho
rt-
circ
uit
withs
tand
Rat
ed s
hort
circu
it
mak
ing
curr
ent
(Pea
k va
lue)
Rat
ed n
omin
al
mak
ing
& b
reak
ing
curr
ent
Mak
ing
- br
eaki
ng
Cap
acitiv
e /
Indu
ctiv
e cu
rren
t (A
)
Eart
hing
sw
itch
/Rai
l ear
thin
g sw
itch
/Aut
omat
ic
PRODUCT Ik (kA) Ima (kA) I1 (A) OPTION OPTION
■ ■ ■ ■ ■ ■ 80 ES*
■ ■ ■ ■ ■ ■ ■ ■ 80 10 / 6,315 / 12,5
AUTO***
■ ■ ■ ■ ■ 50 RES**
■ ■ ■ ■ 12,5 RES**
■ ■ ■ ■ 40 10 (standard) RES**
■ ■ 31,5
■ ■ ■ ■ ■ ■ ■ 63 ES*
■ ■ ■ ■ ■ ■ 50 10 / 6,3 15 / 12,5
ES*
■ ■ ■ 20
■ ■ ■ ■ 31,5 ES*
Pantograph PE ■ ■ ■ ■ ■ 63 ES*
■ ■ ■
■ ■ 31,5
■ ■ 63
IT3000 ■ ■ 50 4 000
IT3600 ■ ■ 50 4 000
ITC4000 ■ ■ 50 4 000
L 31,5 20 1 250 / 2 000
N 31,5 31,5 1 250 / 2 000
H 31,5 40 1 250 / 2 000
L 31,5 20 1 250 / 2 000
N 31,5 31,5 1 250 / 2 000
H 31,5 40 1 250 / 2 000
Vertical break
■
Vacuum breaking
ES
■
CC21155
■
■
■
■
■ ES*
RES**
TECHNOLOGY
Center break
Rocking
Side break
Semi-Pantograph
Vertical break
Selector switch / Change-over switch
Double break
MAKING / BREAKING CURRENTAPPLICATION NETWORK VOLTAGE RATED CURRENT (Ir / In)
TUN
NEL
OVER
HEA
DLI
NES
& F
EED
ERS
SU
BSTA
TIO
NS
3kVDC
600 V 750 V 1500 V 1800 V3000 V
4000
A
15kV AC25kV AC
12 kV12,5 kV15 kV20 kV25 kV
52kV to
550kVAC
1250
A
2000
A
2500
A
3150
A
■■
■
LBS
LOA
D B
REA
K S
WIT
CH
ES(L
BS
)
ST36001
STE
DS
IT25
Rocking
■ ■ ■
ITR
EARTHING SWITCHES
(ES)Earthing Switches
DIS
CO
NN
ECTO
R S
WIT
CH
ES
(DS
)
Fuse holder
SP16700
SBI
SBE
OVB3000 / CS3000
OVB25 / CS25
SR16201H
SST25
SR16200
SBR
■
■
■
Air breaking
SR16203N
■
■
■
■
■
■
CAPTION
*ES : Earthing switch**RES : Rail earthing switch***AUTO : Automatic earthing switch (1 common operating mechanism for disconnector and earthing switch)
Double breakSST25
RockingITR
Vertical breakIT25
Vertical breakITC4000
Vertical breakIT3600
Vertical breakIT3000
Selector switchOVB
Change over switch
CS3000/CS25
Vertical breakSBE / SBI
RockingSBR
Side breakSR16203N
Center breakSR16200
Double breakSR16201H
Semi-PantographSP16700
PantographPE
Earthing switchST36001 / STE
Fuse HolderCC21155
E
SR16200OUTDOOR CENTER BREAK DISCONNECTOR SWITCH UP TO 245kV
MAIN FEATURES
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Used for power transmission and distribution (MV/HV substations, industries) and for railway electrification of catenaries, feeders and substations. • Arrangement in horizontal, vertical position or reversed position, single-pole or group operated. Options: earthing switch, quick breaking device, grease free version for low maintenance. Exists in RTE or SNCF homologated versions.• Standards references: IEC 62271-1/102.
TECHNICAL FEATURES
Condition of use Outdoor/IndoorOperating temperature range -25°C / +40°C (option : special service conditions)Seismic withstand ≤ 0,2 g (option : special service conditions)Ice operation up to 10 mm (option : special service conditions)
SERVICE CONDITIONS
FP053c 2018-08
Rated voltage Ur kV 52 72,5 100 123 145 170 245Rated lightning impulse withstand voltage (BIL) Up kV 250 325 450 550 650 750 1050
Rated frequency Fr Hz 16.7 - 50/60Rated current Ir A 1250 40
31.5kA - 80kAUp to 40/100Up to 50/125
Short time current (Ik max) kA
2000 31.5/40 403150 404000 40
Breaking capacity Optional
ELECTRICAL
Mechanical endurance / lifetime 2 000 operations 10 000 operationsCreepage distance Cl3 (d) Cl4 (e)Insulator type Porcelain (brown) Composite (grey)Primary terminals Aluminium pads Cylindrical / copper / silvered
MECHANICAL standard option
OPTIONAL DEVICES
Configurations Grease free, homologated versions RTE or SNCFOperating mechanisms Electrical drive or manual drive
Quick beaking device (RB) 52kV : «RB» - inductive (6,3A) / capacitive (10A) 72,5kV and 100kV : «MC802» - inductive (6A) / capacitive (15A)
Earthing switch position 1 side or both sides, axial or perpendicular (depending on voltage)Earthing switch operation type Independant or automaticIk earthing switch (kA/1s) Disconnector values with tk:1s (3s values option)Interlocking device MechanicalBus-transfer current switching IEC 62271-102Induced current switching IEC 62271-102
For other values, please contact us.
DIS
CO
NN
ECTO
R S
WIT
CH
SR16200OUTLINE DRAWING
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, i
nfor
mat
ion
is s
ubje
ct t
o ev
olut
ions
and
val
id o
nly
afte
r co
nfirm
atio
n
RELATED EQUIPMENT
SR16201H DOUBLE BREAK DISCONNECTOR
SBE VERTICAL BREAK DISCONNECTOR
PE PANTOGRAPH
DISCONNECTOR
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-OFTPORTABLE
DIAGNOSTIC TOOL
S-COM REMOTE CONTROL
BOARD
* V = Vertical. Above are mentionned maximum dimensions, tolerance +10%. For other values, please consult us.
52kV 4000A V* 970 800 700 500 723 435 126
72,5kV 4000A V* 1150 1000 900 500 900 580 156
100kV 4000A V* 1400 1350 1200 500 1220 680 186
123kV 4000A V* 1730 2166 1650 600 1420 950 282
145kV 4000A V* 1970 2166 1650 600 1620 - 342
170kV 4000A V* 2200 2416 1900 600 1880 - 426
245kV 4000A V* 2870 3016 2500 600 2480 - 582
Ur Ir max
Term
inal
s A B C D E F Weight/pole(approx.)
mm mm mm mm mm mm kg
The drawing above is given for information only. Detailed layout and digital drawing available on request.
D
C
A
B
90°TO CLOSE
POUR FERMER
N° 105053-FR-EN
F
E
SR16201HDOUBLE BREAK DISCONNECTOR SWITCH UP TO 550kV
MAIN FEATURES
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Used for power transmission and distribution (MV/HV and VHV substations, industries), for railway electrification (traction substations, catenaries and feeders.).• Arrangement in horizontal position, single-pole or group operated. Options : earthing switch, enclosed/cubicle, grease free version.• Reference of standards: IEC 62271-1/102, EN 50152-2.
TECHNICAL FEATURES
Condition of use OutdoorOperating temperature range -25°C / +40°C (option : special service conditions)Seismic withstand ≤ 0,2 g (option : special service conditions)Ice operation 1 mm (option: higher service conditions)
SERVICE CONDITIONS
FP077i 2018-08
Rated voltage Ur kV 52 72,5 100 123 145 170 245 300 362 420 550Rated lightning impulse withstand voltage (BIL) Up kV 250 325 450 550 650 750 1050 1175 1300 1425 1550
Rated frequency Fr Hz 16.7 - 50/60Rated current Ir A 1250 31,5 31,5 31,5 31,5 31,5 31,5 31,5 31,5 31,5 31, 31,5
Short time current (Ik max) kA/3s
2000 40 40 40 40 40 40 40 40 40 40 403150 63 63 63 63 63 63 63 50 50 50 504000 63 63 63 63 63 63 63 63 63 63 63
Breaking capacity 0,5A
ELECTRICAL
Mechanical endurance / lifetime 2 000 operations 10 000 operations
Creepage distance Cl3 (d) Cl4 (e)
Insulator type Porcelain (brown) Silicone (grey)
Primary terminals Aluminium pads Cylindrical bare copper terminals
MECHANICAL standard option
OPTIONS
Configurations Gang operated ≤ 245kV, enclosed, grease free version
Operating mechanisms Electrical drive or manual drive
Earthing switch position 1 side or both sides, axial or perpendicular (depending on voltage)
Earthing switch operation type Independant
Ik earthing switch (kA/1s) Disconnector values with tk:1s (contact us for 3s values)
Interlocking device Mechanical
Bus-transfer current switching IEC 62271-102
Induced current switching IEC 62271-102
DISCONNECTOR (DS) AND ASSOCIATED EARTHING SWITCH (ES)
For other values, please contact us.
peak values (Ip peak) for short time currents: 31.5kA:82, 40kA:104, 50kA:130 , 63kA:164, 80kA:208.
DIS
CO
NN
ECTO
R S
WIT
CH
SR16201HOUTLINE DRAWING
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, t
he in
form
atio
n in
thi
s do
cum
ent
is s
ubje
ct t
o ch
ange
with
out
notic
e.
RELATED EQUIPMENT
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-COM REMOTE CONTROL
BOARD
PE PANTOGRAPH
DISCONNECTOR
S-OFTPORTABLE
DIAGNOSTIC TOOL
SR16200CENTER BREAKDISCONNECTOR
STEEARTHING SWITCH
* V= Vertical, H= Horizontal, A= Axial, P= Perpendicular. Above are mentionned maximum dimensions. For other values, please consult us.
52kV 4000A H* 965 1150 780 560 890 1890 130
72,5kV 4000A H* 1175 1350 990 770 1105 2305 160
100kV 4000A H* 1425 1600 1240 1020 1305 2820 220
123kV 4000A H* 1590 2120 1390 1200 1525 3485 270
145kV 4000A H* 1890 2120 1690 1500 1815 3775 300
170kV 4000A H* 2100 2320 1900 1700 2005 4165 440
245kV 4000A H* 2700 3120 2500 2300 2615 5575 700
300kV 4000A H* 3160 3820 2850 1650 3030 6690 750
362kV 4000A H* 3410 4420 3100 2900 3280 7540 950
420kV 4000A H* 4035 5200 3730 3350 3925 8875 1330
550kV 4000A H* 4685 6000 4380 4000 4575 10325 1650
Ur Ir max
Term
inal
s A B C D E F Weight/pole(approx.)
mm mm mm mm mm mm kg
The drawing above is given for information only. Detailed layout and digital drawing available upon request.
G
70°TO CLOSE
POUR FERMER
D
C
B
A
90°
TO C
LOSE
POUR
FERM
ER
E
90°
===>
F
DIS
CO
NN
ECTO
R S
WIT
CH
Rated voltage Ur kV 24 36 38 52 72,5
Rated lightning impulse withstand voltage (BIL) Up kV 95 - 125 170 200 250 325
Rated frequency Fr Hz 16.7 - 50/60 Rated current Ir A 1250 31,5 31,5 31,5 31,5 31,5
Short time current(Ik max) kA
2000 31,5 31,5 31,5 31,5 31,53150 63 63 63 63 -4000 63 63 63 - -6300 63 63 63 - -8000 80 80 80 - -
SBEOUTDOOR VERTICAL BREAK DISCONNECTOR SWITCH UP TO 72.5kV
MAIN FEATURES
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Used for power transmission and distribution (MV/HV substations, industries, SVC & Statcom, mobile substations), for railway electrification (traction and containerized substations, catenaries, feeders, urban networks).• Arrangement in horizontal, vertical, reversed, back to back position, single-pole or group operated. Options: earthing switch, enclosure/cubicle, common frame up to 38kV, grease free version for low maintenance, flexible drive rod for tunnel arrangement.• Standards references : IEC 62271-1/2/102/200, EN 50152-2.
Condition of use OutdoorOperating temperature range -25°C / +40°C (option: special service conditions)Seismic withstand ≤ 0,2 g (option: higher service conditions)Ice operation 1 mm (option: higher service conditions)
FP039g 2018-08
ELECTRICAL
MECHANICAL standard option
OPTIONAL DEVICES
TECHNICAL FEATURES
SERVICE CONDITIONS
Mechanical endurance / lifetime 2 000 operations 10 000 operationsCreepage distance Cl3 (d) Cl4 (e)Insulator type Porcelain (brown) Silicone
Primary terminals Bare copper pads Tinned copper,
silver plated copper or aluminium pads
Configurations Common frame (< BIL 200kV), enclosed, grease free, flexible rodOperating mechanisms Electrical drive or manual drive
Quick beaking device (RB) ≤ 52kV : RB - inductive (6,3A) / capacitive (10A) ≥ 52kV : MC802 - inductive (6A) / capacitive (15A)
Small current breaking and making device (arcing horns) 0.5
Earthing switch position 1 side or both sidesEarthing switch operation type Independent or automatic *Ik earthing switch (kA/1s) Same as disconnector values with tk:1s (contact us for 3s values)
* When disconnector opens, earthing switch closes and conversely. For other values, please contact us.
peak values (Ip peak) in kA for short time current: 31.5kA: 82 - 63kA: 164 - 80kA: 208.
DIS
CO
NN
ECTO
R S
WIT
CH
SBEOUTLINE DRAWING
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, i
nfor
mat
ion
is s
ubje
ct t
o ev
olut
ions
and
val
id o
nly
afte
r co
nfirm
atio
n
RELATED EQUIPMENT
ST90 EARTHING SWITCH
MR41E UNIVERSAL SMART
DRIVE
SBI VERTICAL BREAK DISCONNECTOR
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-VOLT VOLTAGE DETECTOR
S-COM REMOTE CONTROL
BOARD
* V = Vertical. H = Horizontal. Above are mentionned maximum dimensions, tolerance +10%. For other values, please contact us.
3-24kV 8000A 1000 850 575 630 525
From 30 to 80
36kV 8000A 1293 1000 745 630 517
38kV 8000A 1280 1000 727 630 482
52kV 3150A 1585 1160 843 630 600
72,5kV 2000A 1815 1435 1000 630 810
Ur Ir max A B C D E Weight/pole(approx.)
mm mm mm mm mm kg
Detailed layout and digital drawing available on request.
Terminal pads Ir Nb pads Position Ir Nb pads Position Ir Nb pads Position Ir Nb pads Position
1250A/2000A 1 H* 3150A/4000A 1 V* 6300A 2 V* 8000A 3 V*
C
D
A
90°
90°BE
SBIINDOOR VERTICAL BREAK DISCONNECTOR SWITCH UP TO 38kV
MAIN FEATURES
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
DIS
CO
NN
ECTO
R S
WIT
CH
• Used for power transmission and distribution (MV/HV substations, industries), for railway electrification (substations, urban networks and tunnel application) and for power production. • Arrangement in horizontal, vertical, reversed position, single-pole or group operated. Options : earthing switch, enclosure/cubicle, common frame up to 38kV, grease free version for low maintenance, flexible drive rod for tunnel arrangement.• Standards references: IEC 62271-1/102/200.
TECHNICAL FEATURES
Condition of use IndoorOperating temperature range -25°C / +40°C (option : special service conditions)Seismic withstand ≤ 0,2 g (option : higher service conditions)Ice operation NA
SERVICE CONDITIONS
FP043e 2018-08
Rated voltage Ur kV 3,6 7,2 24 36-38Rated lightning impulse withstand voltage (BIL) Up kV 40 60 125 170
Rated frequency Fr Hz DC / 16.7 / 50 / 60Rated current Ir A 1250 31,5 31,5 31,5 31,5
Short time current (Ik max) kA
2000 31,5 31,5 31,5 31,53150 63 63 63 634000 - - 63 636300 - - 63 638000 - - 80 80
Breaking capacity 0,5A
ELECTRICAL
Mechanical endurance / lifetime 2 000 operations 10 000 operationsCreepage distance Cl3 (d) or Cl4 (e) -
Insulator type Epoxy (red) Silicone (grey) or porcelain (brown)
Primary terminals Bare copper pads Tinned copper,
silver plated copper or aluminium pads
MECHANICAL standard option
OPTIONAL DEVICES
Configurations Common frame (< BIL 200kV), enclosed, grease free, flexible rodOperating mechanisms Electrical drive or manual drive Quick making device (FB) 24 kV (7000A under 3kV / 0,4s)Small current breaking and making device (arcing horns) Available
Earthing switch position 1 side or both sidesEarthing switch operation type Independant, automatic *Ik earthing switch (kA/1s) Disconnector values with tk:1s (contact us for 3s values)Interlocking device Mechanical (key lock)
- Not available. * When disconnector opens, earthing switch closes and conversely.For other values, please consult us.
peak values (Ip peak) in kA for short time currents: 31.5kA: 82 - 63kA: 164 - 80kA: 208.
SBIOUTLINE DRAWING
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
Detailed layout and digital drawing available on request.
Due
to
prod
uct
evol
utio
ns, i
nfor
mat
ion
is s
ubje
ct t
o ev
olut
ions
and
val
id o
nly
afte
r co
nfirm
atio
n
3,6kV 3150A 570 790 415 500 -
from 30 to 108 7,2kV 3150A 910 850 495 510 285
24kV 8000A 950 850 495 630 255
36-38kV 8000A 1125 1000 580 630 340
* V = Vertical. H = Horizontal. Above are mentionned maximum dimensions, tolerance +10% . For other values, please consult us.
A
90°
90°
D
E
C
B
Ur Ir max A B C D E Weight/pole(approx.)
mm mm mm mm mm kg
Terminal pads Ir Nb pads Position Ir Nb pads Position Ir Nb pads Position Ir Nb pads Position
1250A/2000A 1 H* 3150A/4000A 1 V* 6300A 2 V* 8000A 3 V*
RELATED EQUIPMENT
SBE VERTICAL BREAK DISCONNECTOR
MR41E UNIVERSAL SMART
DRIVE
SB250 VERTICAL BREAK DISCONNECTOR
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-POSITIONPOSITION INDICATOR
S-COM REMOTE CONTROL
BOARD
Rated voltage Ur kV 3 25
Rated lightning impulse withstand voltage (BIL) Up kV 95 250
Rated frequency Fr Hz 0 / 16.7 - 50/60Rated current (max) Ir A 1250 31,5 31,5Short time current(Ik) kA 2500 40 40
Breaking capacity 0,5A
SBROUTDOOR ROCKING DISCONNECTOR SWITCH UP TO 52 kV
MAIN FEATURES
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Used for railway electrification of catenaries and feeders for 3kV or 25kV or 2x25kV networks.• Arrangement in horizontal or vertical position, single-pole or group operated. Options: to rail switch, common frame, grease free version for low maintenance.• Standards references : IEC 62271-1/102, EN 50152-2,
Condition of use OutdoorOperating temperature range -25°C / +40°C (option: special service conditions)Seismic withstand ≤ 0,2 g (option: higher service conditions)Ice operation 1 mm (option : special service conditions)
FP059j 2018-08
ELECTRICAL
MECHANICAL standard option
OPTIONAL DEVICES
TECHNICAL FEATURES
SERVICE CONDITIONS
Mechanical endurance / lifetime 2 000 operations 10 000 operationsCreepage distance Cl3 (d) Cl4 (e)Insulator type Porcelain (brown) Silicone (grey)
Primary terminals Copper pads Tinned copper, silver plated copper
Configurations Common frame (< BIL 200kV), grease free versionOperating mechanisms Electrical drive or manual drive Small current breaking and making device (arcing horns) I4a: 10A
To rail switch position 1 sideTo rail switch operation type Automatic*Ik earthing switch To rail switch
* When disconnector opens, earthing switch closes and conversely. For other values, please contact us.
peak values (Ip) in kA for short time currents: 31.5kA: 82 - 40kA: 104.
DIS
CO
NN
ECTO
R S
WIT
CH
SBROUTLINE DRAWING
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, i
nfor
mat
ion
is s
ubje
ct t
o ev
olut
ions
and
val
id o
nly
afte
r co
nfirm
atio
n
RELATED EQUIPMENT
ITRROCKING VACUUM
BREAK SWITCH
SBEVERTICAL BREAK DISCONNECTOR
IT25NVACUUM
BREAK SWITCH
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-VOLTVOLTAGE DETECTOR
S-COM REMOTE CONTROL
BOARD
* V = Vertical. Above are mentionned maximum dimensions, tolerance +10%. For other values, please contact us.
52kV 2500A V* 1300 1250 1122 760 160 360
Ur Ir max
Term
inal
s A B B’ C D E
mm mm mm mm mm mm
Detailed layout and digital drawing available on request.
B
E
A
B’
D
C
SR16203NOUTDOOR SIDE BREAK DISCONNECTOR SWITCH UP TO 52kV
MAIN FEATURES
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Used for railway electrification of MV/HV substations, 25kV or 2x25kV networks.• Arrangement in horizontal, vertical or back-to-back position, single-pole or group operated. Options: opening on left or right side.• Standards references: IEC 62271-1/-2/-102, EN 50152-2.
TECHNICAL FEATURES
Condition of use OutdoorOperating temperature range -25°C / +40°C (option : special service conditions)Seismic withstand ≤ 0,2 g (option : special service conditions)Ice operation 10 mm (option : special service conditions)
SERVICE CONDITIONS
FP098b 2018-08
Rated voltage Ur kV 25Rated lightning impulse withstand voltage (BIL) Up kV 250
Rated frequency Fr Hz 16.7 - 50/60Rated current Ir A 1250, 2500Short time current Ik max kA 25
ELECTRICAL
Mechanical endurance / lifetime 2 000 operations 10 000 operationsCreepage distance Cl3 (d) Cl4 (e)Insulator type Porcelain (brown) -Primary terminals Aluminium pads Tinned copper pads
MECHANICAL standard option
OPTIONAL DEVICES
Configurations Opening left or right, SNCF homologated versionOperating mechanisms Electrical drive or manual drive Earthing switch position 1 side
For other values, please contact us.
peak values (Ip peak) in kA for short time current: 25kA: 63.
DIS
CO
NN
ECTO
R S
WIT
CH
SR16203NOUTLINE DRAWING
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, i
nfor
mat
ion
is s
ubje
ct t
o ev
olut
ions
and
val
id o
nly
afte
r co
nfirm
atio
n
RELATED EQUIPMENT
OVBSELECTOR SWITCH
SBEVERTICAL BREAK DISCONNECTOR
IT25NVACUUM
BREAK SWITCH
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-VOLTVOLTAGE DETECTOR
S-COM REMOTE CONTROL
BOARD
* V = Vertical. H = Horizontal. Above are mentionned maximum dimensions, tolerance +10%. For other values, please consult us.
25kV 1250A V and H* 975 1000 656 310 805 60
52kV 2500A V and H* 900 1000 687 310 805 85
Ur Ir max Terminals A B C D E Weight/pole(approx.)
mm mm mm mm mm kg
Detailed layout and digital drawing available on request.
C
B
132
R860 ±10 90°
TO CLOSE
D
E
A
EARTH CONNECTION13
SST25TUNNEL DOUBLE BREAK DISCONNECTOR SWITCH UP TO 25kV
MAIN FEATURES
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Used in railway electrification for supply of tunnel catenaries.• Arrangement in horizontal upside-down position, single-pole operated. Options: flexible drive rod for tunnel arrangement.• Standards references: IEC 62271-1 -2 -102, EN 50152-2.
TECHNICAL FEATURES
Condition of use Indoor (in tunnel)Operating temperature range -25°C / +40°C (option : special service conditions)Seismic withstand ≤ 0,2 g (option : special service conditions)Ice operation NA
SERVICE CONDITIONS
FP048b 2018-08
Rated voltage Ur kV 25Rated lightning impulse withstand voltage (BIL) Up kV 170
Rated frequency Fr Hz 16.7 - 50/60Rated current Ir A 2500/4000Short time current Ik max kA 31.5Breaking capacity 0,5A
ELECTRICAL
Mechanical endurance / lifetime 2 000 operations 10 000 operationsCreepage distance Cl3 (d) Cl4 (e)Insulator type Silicone (grey) -Primary terminals Silver plated copper pads -
MECHANICAL standard option
OPTIONAL DEVICES
Configurations Flexible drive rod for tunnel arrangementOperating mechanisms Electrical drive or manual drive
- Not available. For other values, please contact us.
peak values (Ip peak) in kA for short time current: 31.5kA: 82
DIS
CO
NN
ECTO
R S
WIT
CH
SST25OUTLINE DRAWING
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, i
nfor
mat
ion
is s
ubje
ct t
o ev
olut
ions
and
val
id o
nly
afte
r co
nfirm
atio
n
RELATED EQUIPMENT
SBIVERTICAL BREAK DISCONNECTOR
SR16201H DOUBLE BREAK DISCONNECTOR
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-VOLTVOLTAGE DETECTOR
S-COM REMOTE CONTROL
BOARD
MR41E UNIVERSAL SMART
DRIVE
* V = Vertical. H = Horizontal. Above are mentionned maximum dimensions, tolerance +10%. For other values, please consult us.
25kV 2500A H* 490 760 1000 590 200 40
Ur Ir max Terminals A B C D E Weight/pole(approx.)
mm mm mm mm mm kg
90°
A
B
C
D
E
TO OPEN DISCONNECTOR
CLOSED DISCONNECTOR OPENED DISCONNECTOR
Detailed layout and digital drawing available on request.
Rated voltage Ur kV 1,5 3 25
Rated lightning impulse withstand voltage (BIL) Up kV 95 250
Rated frequency Fr Hz 0 / 16.7 / 50/60 Rated current Ir A 1000 50 -
Short time current(Ik max) kA
1250 - 202000 50 -4000 50 -
Breaking capacity 0,5A
OVBOUTDOOR SELECTOR SWITCH UP TO 25kV
MAIN FEATURES
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Used for railway electrification (tunnel, catenaries and feeders).• Arrangement in reversed position, single-pole or group operated. • Options: to-rail switch, selector switch or change-over switch version. • Standards references : IEC 62271-1/102, EN 50152-2, EN 50153-3/4.
Condition of use OutdoorOperating temperature range -25°C / +40°C (option: special service conditions)Seismic withstand ≤ 0,2 g (option: higher service conditions)Ice operation 10 mm (option: higher service conditions)
FP050d 2018-08
ELECTRICAL
MECHANICAL standard option
OPTIONAL DEVICES
TECHNICAL FEATURES
SERVICE CONDITIONS
Mechanical endurance / lifetime 2 000 operations 10 000 operationCreepage distance Cl3 (d) Cl4 (e)Insulator type Porcelain (brown) -Primary terminals Nickel plated copper pads Siver
Operating mechanisms Electrical drive or manual drive Change-over switch Available for 2000A
For other values, please contact us.
peak values (Ip peak) in kA for short time currents: 12.5kA: 32 - 20kA: 52 - 31.5kA: 82 - 50kA: 130.
DIS
CO
NN
ECTO
R S
WIT
CH
OVBOUTLINE DRAWING
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, i
nfor
mat
ion
is s
ubje
ct t
o ev
olut
ions
and
val
id o
nly
afte
r co
nfirm
atio
n
RELATED EQUIPMENT
IT3000 AIR BREAKING
SWITCH
SBRROCKING
DISCONNECTOR
SBEVERTICAL BREAK DISCONNECTOR
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-VOLT VOLTAGE DETECTOR
S-COM REMOTE CONTROL
BOARD
* V = Vertical. H = Horizontal. Above are mentionned maximum dimensions, tolerance +10%. For other values, please contact us.
1.5kV 4000A 592 650 507 20065
3kV 4000A 572 900 485 200
Ur Ir max A B C D Weight/pole(approx.)
mm mm mm mm kg
Detailed layout and digital drawing available on request.
60°
A
B
CD
CC21155OUTDOOR FUSE HOLDER
MAIN FEATURES
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Used for railway electrification for catenaries and feeders.• Arrangement in horizontal position, vertical position, single pole. • Reference of standards: IEC 62271-1/102.
TECHNICAL FEATURES
Condition of use Outdoor/IndoorOperating temperature range -25°C / +40°C (option : special service conditions)Seismic withstand ≤ 0,2 g (option : special service conditions)Ice operation up to 10 mm (option : special service conditions)
SERVICE CONDITIONS
FP0000 2018-08
Rated voltage Ur kV 24 36 52Rated lightning impulse withstand voltage (BIL) Up kV 125 170 250
Rated frequency Fr Hz 16.7 - 50/60Rated current Ir A 2 to 100 A
ELECTRICAL
Insulator type Porcelain (brown) -Primary terminals Copper pads Other
MECHANICAL standard option
For other values, please contact us.
DIS
CO
NN
ECTO
R S
WIT
CH
CC21155OUTLINE DRAWING
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, i
nfor
mat
ion
is s
ubje
ct t
o ev
olut
ions
and
val
id o
nly
afte
r co
nfirm
atio
n
RELATED EQUIPMENT
SR16200CENTER BREAK DISCONNECTOR
SBE VERTICAL BREAK DISCONNECTOR
SR16203NSIDE BREAK
DISCONNECTOR
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-VOLTVOLTAGE DETECTOR
FOR RAILWAY DS/LBS
S-COM REMOTE CONTROL
BOARD
* V = Vertical. Above are mentionned maximum dimensions, tolerance +10%. For other values, please consult us.
36kV V* 860 660 770 160 200
Ur
Term
inal
s A B C D D’
mm mm mm mm mm
The drawing above is given for information only. Detailed layout and digital drawing available on request.
A
C
B
A
D’D
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com FP056d 2018-08
EAR
THIN
G S
WIT
CH
OUTDOOR EARTHING SWITCH UP TO 100kV
ST36001MAIN FEATURES• Used for power transmission and distribution (MV/HV substations, industries, SVC & Statcom substations), and for railway electrification (MV/HV substations).• Arrangement in horizontal position, single-pole or group operated. Option: induced current switching device. Exists in RTE homologated version. • Standards references : IEC 62271-1/102
Rated voltage Ur kV 72,5 100Rated lightning impulse withstand voltage (BIL) Up kV 325 450
Rated frequency f Hz 16.7 - 50/60Short time current Ik max kA 31,5Breaking capacity 0,5A
Condition of use OutdoorOperating temperature range -25°C / +40°C (option: special service conditions)Seismic withstand ≤ 0,2 g (option: higher service conditions)Ice operation 10 mm (option: higher service conditions)
ELECTRICAL
MECHANICAL standard option
OPTIONAL DEVICES
TECHNICAL FEATURES
SERVICE CONDITIONS
Mechanical endurance / lifetime 4 000 operations -Creepage distance Cl3 (d) Cl4 (e)Insulator type Porcelain (brown) -
Primary terminals Aluminium pads -
Interlocking device Mechanical (key lock) -
Configurations Single-pole or group operated. homologated version RTEOperating mechanisms Electrical drive or manual drive Induced current switching IEC 62271-102 Annexe B and §5.104
- Not available. For other values, please contact us.
peak values (Ip peak) in kA for short time current: 31.5kA: 82.
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, i
nfor
mat
ion
is s
ubje
ct t
o ev
olut
ions
and
val
id o
nly
afte
r co
nfirm
atio
n
Detailed layout and digital drawing available on request.
A
B
D
C
E
ST36001OUTLINE DRAWING
* V = Vertical. H = Horizontal. Above are mentionned maximum dimensions, tolerance +10%. For other values, please contact us.
72,5 kV V 1190 250 160 460 1120 60
100 kV V 1440 250 160 460 1370 80
Ur
Term
inal
s A B C D E Weight/pole (approx.)
mm mm mm mm mm kg
RELATED EQUIPMENT
SR16200CENTER BREAK DISCONNECTOR
SBEVERTICAL BREAK DISCONNECTOR
SR16201HDOUBLE BREAK DISCONNECTOR
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-OFTPORTABLE
DIAGNOSTIC TOOL
S-COM REMOTE CONTROL
BOARD
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com FP094e 2018-08
EAR
THIN
G S
WIT
CH
OUTDOOR EARTHING SWITCH UP TO 550kV
STEMAIN FEATURES• Used for power transmission and distribution VHV substations and railway substations.• Arrangement in horizontal position, single-pole or group operated. • Standards references : IEC 62271-1/102.
Rated voltage Ur kV 123 145 170 245 300 362 420 550Rated lightning impulse withstand voltage (BIL) Up kV 550 650 750 1175 1300 1425 1550 1800
Rated frequency f Hz 50/60 / 16 2/3 HzShort time current Ik max kA 63Breaking capacity 0,5 A
Condition of use OutdoorOperating temperature range -25°C / +40°C (option: special service conditions)Seismic withstand ≤ 0,2 g (option: higher service conditions)Ice operation 10 mm (option: higher service conditions)
ELECTRICAL
MECHANICAL standard option
OPTIONAL DEVICES
TECHNICAL FEATURES
SERVICE CONDITIONS
Mechanical endurance / lifetime 1 000 operations 2 000 operationsCreepage distance Cl3 (d) Cl4 (e)Insulator type porcelain (brown) -Primary terminals aluminium pads cylindrical copper terminalsInterlocking device mechanical (key lock) -
Configurations single-pole or group operated. Short time currents in 3s values.Operating mechanisms electrical drive or manual drive Induced current switching IEC 62271-102 Annexe B and § 5.104
For other values, please contact us.
peak values (Ip peak) in kA for short time current: 63kA: 164.
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, i
nfor
mat
ion
is s
ubje
ct t
o ev
olut
ions
and
val
id o
nly
afte
r co
nfirm
atio
n
Detailed layout and digital drawing available on request.
B
E
C
STEOUTLINE DRAWING
* H = Horizontal. Above are mentionned maximum dimensions, tolerance +10%. For other values, please contact us.
123 kV H* 1410 360 1410 490 1285 80
145 kV H* 1690 360 1690 490 1575 100
170 kV H* 1900 360 1900 490 1780 140
245 kV H* 2500 360 2500 490 2375 190
300 kV H* 3095 360 2905 490 2790 220
362 kV H* 3345 360 3155 490 3040 250
420 kV H* 3920 500 3730 720 3585 340
550 kV H* 4570 500 4380 720 4235 385
Ur
Term
inal
s A B C D E Weight/pole (approx.)
mm mm mm mm mm kg
RELATED EQUIPMENT
PEPANTOGRAPH
DISCONNECTOR
MR41EUNIVERSAL SMART
DRIVE
SR16201HDOUBLE BREAK DISCONNECTOR
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-OFTPORTABLE
DIAGNOSTIC TOOL
S-COM REMOTE CONTROL
BOARD
IT3000OUTDOOR AIR BREAKING SWITCH UP TO 3kV
MAIN FEATURES
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Used for railway electrification of catenaries and feeders.• Arrangement in horizontal position, single-pole or group operated. • Standards references : IEC 62271-1/102, EN 50152-2, EN 50123-4.
TECHNICAL FEATURES
Condition of use OutdoorOperating temperature range -25°C / +40°C (option : special service conditions)Seismic withstand ≤ 0,2 g (option : special service conditions)Ice operation 1 mm (option : special service conditions)
SERVICE CONDITIONS
FP037c 2018-08
Rated voltage Ur kV 750V 1,5 3Rated lightning impulse withstand voltage (BIL) Up kV 95
Rated frequency Fr Hz 50/60Rated current Ir A 2 000 - 3000 - 4000Short time current Ik max kA 50Breaking capacity of small currents A 0,5Rated making short circuit current Ima kA -
ELECTRICAL
Mechanical endurance / lifetime 2 000 operations 10 000 operationsCreepage distance Cl3 (d) Cl4 (e)Insulator type porcelain (brown) -Primary terminals nickel plated copper pads other
MECHANICAL standard option
OPTIONAL DEVICES
Configurations single pole or group operated
Operating mechanisms electrical drive or manual drive
For other values, please contact us.
peak values (Ip peak) in kA for short time currents: 50kA: 130.
LOA
D B
REA
K S
WIT
CH
IT3000OUTLINE DRAWING
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, i
nfor
mat
ion
is s
ubje
ct t
o ev
olut
ions
and
val
id o
nly
afte
r co
nfirm
atio
n
RELATED EQUIPMENT
OVBSELECTOR SWITCH
SBEVERTICAL BREAK DISCONNECTOR
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-VOLTVOLTAGE DETECTOR
S-COM REMOTE CONTROL
BOARD
MR41EUNIVERSAL SMART
DRIVE
* H = Horizontal. Above are mentionned maximum dimensions, tolerance +10%. For other values, please consult us.
3kV 4000 H* 1195 870 639 290 480 130
Ur Ir max
Term
inal
s A B C D E Weight/pole(approx.)
mm mm mm mm mm kg
A
B
C
D E
Detailed layout and digital drawing available on request.
IT3600OUTDOOR AIR BREAKING SWITCH UP TO 3kV
MAIN FEATURES
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Used for railway electrification of catenaries and feeders.• Arrangement in horizontal position, single-pole or group operated. • Standards references: IEC 62271-1, IEC 62271-103, EN 50152-2, EN 50123-1.
TECHNICAL FEATURES
Condition of use OutdoorOperating temperature range -25°C / +40°C (option : special service conditions)Seismic withstand ≤ 0,2 g (option : special service conditions)Ice operation 10 mm (option : special service conditions)
SERVICE CONDITIONS
FP034d 2018-08
Rated voltage Ur kV 750V 1,5 3Rated lightning impulse withstand voltage (BIL) Up kV 95
Rated frequency Fr Hz DCRated current Ir A 4000Short time current Ik max kA 50/1sRated making short circuit current Ima kA 60kA peak
ELECTRICAL
Mechanical endurance / lifetime 10 000 operations -Creepage distance Cl3 (d) Cl4 (e)Insulator type Porcelain (brown) -Primary terminals Copper pads Other
MECHANICAL standard option
OPTIONAL DEVICES
Configurations Single pole or group operated
Operating mechanisms Electrical drive or manual drive
For other values, please contact us.
peak values (Ip peak) in kA for short time current: 50kA: 130.
LOA
D B
REA
K S
WIT
CH
IT3600OUTLINE DRAWING
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, i
nfor
mat
ion
is s
ubje
ct t
o ev
olut
ions
and
val
id o
nly
afte
r co
nfirm
atio
nRELATED EQUIPMENT
OVBSELECTOR SWITCH
SBEVERTICAL BREAK DISCONNECTOR
SBRROCKING
DISCONNECTOR
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-VOLTVOLTAGE DETECTOR
S-COM REMOTE CONTROL
BOARD
* H = Horizontal. Above are mentionned maximum dimensions, tolerance +10%. For other values, please consult us.
3kV 4000A H* 1424 630 454 859 110 1102 60
Ur Ir max
Term
inal
s A B C C’ D E Weight/pole(approx.)
mm mm mm mm mm mm kg
Detailed layout and digital drawing available on request.
E
A
C’
CLOSED
D
C
110°
OPENED
E
CLOSED
B
ITC4000OUTDOOR AIR BREAKING SWITCH UP TO 3kV
MAIN FEATURES
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Used for railway electrification of catenaries and feeders.• Arrangement in horizontal position, single-pole or group operated. • Standards references: IEC 62271-1, EN 50152-2, EN 50123-1, EN 50123-4
TECHNICAL FEATURES
Condition of use OutdoorOperating temperature range -25°C / +40°C (option : special service conditions)Seismic withstand ≤ 0,2 g (option : special service conditions)Ice operation 1 mm (option : special service conditions)
SERVICE CONDITIONS
FP033d 2018-08
Rated voltage Ur kV 750V 1,5 3Rated lightning impulse withstand voltage (BIL) Up kV 40kV (SIL 95kV)
Rated frequency Fr Hz DCRated current Ir A 4000Short time current Ik max kA 50kA/3sec
ELECTRICAL
Mechanical endurance / lifetime 2 000 operations 10 000 operationsCreepage distance Cl3 (d) Cl4 (e)Insulator type Silicone (grey) OtherPrimary terminals Copper pads Other
MECHANICAL standard option
OPTIONAL DEVICES
Configurations Single pole or group operated, SNCF homologated version
Operating mechanisms Electrical drive or manual drive Small current breaking and making device Available
For other values, please contact us.
peak values (Ip peak) in kA for short time currents: 50kA: 130.
LOA
D B
REA
K S
WIT
CH
ITC4000OUTLINE DRAWING
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, i
nfor
mat
ion
is s
ubje
ct t
o ev
olut
ions
and
val
id o
nly
afte
r co
nfirm
atio
n
RELATED EQUIPMENT
OVBSELECTOR SWITCH
SBEVERTICAL BREAK DISCONNECTOR
SBRROCKING
DISCONNECTOR
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-VOLTVOLTAGE DETECTOR
S-COM REMOTE CONTROL
BOARD
* H = Horizontal. Above are mentionned maximum dimensions, tolerance +10%. For other values, please consult us.
3kV 4000A H* 855 530 455 950 80
Ur Ir max
Term
inal
s A B C D Weight/pole(approx.)
mm mm mm mm kg
Detailed layout and digital drawing available on request.
OPEN POSITION
A
B
C
D
IT25OUTDOOR VACUUM BREAKING SWITCH UP TO 52kV
MAIN FEATURES
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Used for railway electrification of catenaries, feeders, substations and containerized substations.• Arrangement in horizontal or vertical position, or back-to-back position, single-pole or group operated. Options: earthing switch, enclosure/cubicle, grease free version for low maintenance. • Standards references : IEC 62271-1/103, EN 50152-2
TECHNICAL FEATURES
Condition of use Outdoor or cubicleOperating temperature range -25°C / +40°C (option : special service conditions)Seismic withstand ≤ 0,2 g (option : special service conditions)Ice operation 10 mm (option : special service conditions)
SERVICE CONDITIONS
FP063f 2018-08
Rated voltage Ur kV 25Rated lightning impulse withstand voltage (BIL) Up kV 250
Rated frequency Fr Hz 50/60Rated current Ir A 2 000Short time current Ik kA 31,5Rated making short circuit current Ima kA 20 (IT25L) 31,5 (IT25N) 50 (IT25H)
ELECTRICAL
Mechanical endurance / lifetime 10 000 operations -Creepage distance Cl3 (d) Cl4 (e)Insulator type Porcelain (brown) Composite
Primary terminals Copper padsTinned copper
or silver plated copper
MECHANICAL standard option
OPTIONAL DEVICES
Configurations Enclosed, grease free versionOperating mechanisms Electrical drive or manual drive Earthing switch position 1 side or both sidesEarthing switch operation type Independant or automatic *Ik earthing switch (kA/1s) Disconnector values contact us for 3s values)Interlocking device Mechanical
* When disconnector opens, earthing switch closes and conversely. For other values, please contact us.
peak values (Ip) in kA for short time currents: 31,5kA: 82.
LOA
D B
REA
K S
WIT
CH
IT25OUTLINE DRAWING
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, i
nfor
mat
ion
is s
ubje
ct t
o ev
olut
ions
and
val
id o
nly
afte
r co
nfirm
atio
n
RELATED EQUIPMENT
ITRROCKING VACUUM
BREAK SWITCH
SBEVERTICAL BREAK DISCONNECTOR
MR41EUNIVERSAL SMART
DRIVE
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-VOLTVOLTAGE DETECTOR
S-COM REMOTE CONTROL
BOARD
* H = Horizontal. Above are mentionned maximum dimensions, tolerance +10%. For other values, please consult us.
52kV 2000A H* 1651 1225 1160 855 630 1430 657 107
Ur Ir max
Term
inal
s A A’ B C D E F Weight/pole(approx.)
mm mm mm mm mm mm mm kg
Detailed layout and digital drawing available on request.
C
8
B
F
E
A'
D
A
ITROUTDOOR VACUUM BREAKING SWITCH UP TO 52kV
MAIN FEATURES
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Used for railway electrification of catenaries and feeders.• Arrangement in horizontal position, single-pole or group operated. Options: earthing switch, enclosed/cubicle, grease free version for low maintenance. • Standards references : IEC 62271-1 -2 -103 -200, EN 50152-2.
TECHNICAL FEATURES
Condition of use OutdoorOperating temperature range -25°C / +40°C (option : special service conditions)Seismic withstand ≤ 0,2 g (option : higher service conditions)Ice operation 1 mm (option: higher service conditions)
SERVICE CONDITIONS
FP107d 2018-01
Rated voltage Ur kV 25 52Rated lightning impulse withstand voltage (BIL) Up kV 250
Rated frequency f Hz 50Rated current Ir A 1 250 - 2 000Short time current Ik max kA 31,5Breaking capacity of small currents A 0,5Rated making short circuit current Ima kA 20 (ITR-L) 31,5 (ITR-N) 50 (ITR-H)
ELECTRICAL
Mechanical endurance / lifetime 20 000 operations -Creepage distance Cl3 (d) Cl4 (e)Insulator type porcelain (brown) silicone (grey)
Primary terminals copper padsbare copper,tinned copper
or silver plated copper
MECHANICAL standard option
OPTIONAL DEVICES
Configurations enclosed, grease free version
Operating mechanisms electrical drive or manual drive Earthing switch position 1 sideEarthing switch operation type automatic* to-rail switchIk earthing switch (kA/1s) disconnector values with tk:1s (contact us for 3s values)Interlocking device mechanical (key lock)
- Not available. * When disconnector opens, earthing switch closes and conversely. For other values, please contact us.
peak values (Ip peak) in kA for short time currents: 31,5kA: 82.
LOA
D B
REA
K S
WIT
CH
ITROUTLINE DRAWING
10, allée des plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, i
nfor
mat
ion
is s
ubje
ct t
o ev
olut
ions
and
val
id o
nly
afte
r co
nfirm
atio
n
RELATED EQUIPMENT
SBRROCKING
DISCONNECTOR
IT25NVACUUM
BREAK SWITCH
MR41EUNIVERSAL SMART
DRIVE
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-VOLTVOLTAGE DETECTOR
S-COM REMOTE CONTROL
BOARD
* H = Horizontal. Above are mentionned maximum dimensions, tolerance +10%. For other values, please consult us.
25kV 1250A H* 1320 1050 310 826 355
52kV 2000A H* 1380 1095 310 887 355
Ur Ir max
Term
inal
s A B B’ C D
mm mm mm mm mm
The drawing above is given for information only. Detailed layout and digital drawing available on request.
B’
C
85
D
A
B
open gap310 ±30
52° ±3°
to close
MR41EELECTRICAL OPERATING MECHANISM / UNIVERSAL SMART DRIVE
MAIN FEATURES
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Reliable, powerful and cost effective• 6000 units operating worlwide• Robust design, suitable for harsh environmental conditions (humidy, heat, cold, corrosive atmosphere, ..)• Easy to install: compact, lightweight, reduced installation time• Real time condition monitoring (native IED, embedded sensors, Plug&Play options)• Perfect for existing switches motorization or remotorization.
FP014m 2018-08
CONTROL & MONITORING
CUSTOMER BENEFITS• Universal smart dive: flexible configuration• Plug and play, easy wiring• Increased grid safety: early detection of mechanical or electrical failures• Condition based maintenance (CBM) / predictive maintenance of HV switches and operating mechanism• Smart grid ready, fully IEC61850 compliant• On site condition assesment / self diagnosis
COMMUNICATION
BASE OPTIONInterfaces Copper wires RS232 / RS485 / fiber optics
Protocol Analog Digital : S-COM (Modbus RTU, Modbus TCP, IEC61850, ..)
Priority mode Analog Dual mode: analog digital automatic switch
CONDITION MONITORING
BASE OPTION
Torque monitoring of the HV switch -
S-TORQUE: low / mean / max torque, alert on output relay / through IT network
Light display on the box - S-LUXInside humidity - S-WET hygrometerInformation record Last operation parameters S-MEMORY: data recorder10 leds display for operational informations status -
3-digits display with informations code and 10 parameters menu
S-DIGIT -
Operating mechanism automatic self diagnosis
More than 90 real-time monitored operational parameters: Operation counter ü real time monitored alert on output relay / through IT network Motor overload ü real time monitored alert on output relay / through IT network Inside temperature ü real time monitored alert on output relay / through IT network
Low / Mean / Max motor voltage supply ü real time monitored alert on output relay / through IT network
Low / Mean / Max operating current ü real time monitored alert on output relay / through IT network
Presence of auxiliary supply ü real time monitored alert on output relay / through IT network
Anticondensation heater health ü real time monitored alert on output relay / through IT network
Anticondensation heater power supply ü real time monitored alert on output relay / through IT network
Operating time ü real time monitored alert on output relay / through IT network Interlock ü real time monitored alert on output relay / through IT network Selector position (local/ remote/out of use/manual) ü real time monitored alert on output relay / through IT network
Operation in progress (opening / closing) ü real time monitored alert on output relay / through IT network
…Ask for your specific need
OP
ERA
TIN
G D
RIV
ES
MR41E
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, t
he in
form
atio
n in
thi
s do
cum
ent
is s
ubje
ct t
o ch
ange
with
out
notic
e.
TECHNICAL FEATURESMECHANICAL
BASE OPTION
Drive / Transmission mecha-nism
Electrical motor, non-reversible mechanism -
Operating angle 90° -Operating time <10 s other value upon requestOutput shaft position left / right / vertical -Output torque 1 000 N.m 2 000 N.mMechanical endurance 2000 cycles 10000 cycles, other value upon requestOperating temperature - 25°C / + 40°C On requestDimensions 360 x 500 x 340 mm -Weight 25 kg -Protection degree IP56 -
ELECTRICAL
BASE OPTIONMotor Power supply voltage 48 to 220 VDC / 60 to 400 VAC On request Frequency range DC / 16 Hz 2/3 / 50 Hz /60 Hz Nominal power 300 WAuxiliary supply voltage 48 to 220 VDC / 110 to 230 VAC On requestAuxiliary Contacts O/C NO/NC 8O / 8C xO / xC / xNO / xNC upon requestAnticondensation heater Supply voltage 230VAC 110 VDC Nominal power 25W 100WAdditionnal output relays 2 up to 5EMC IEC61000 On request
OUTLINE DRAWING
RELATED EQUIPMENT
SR16200 CENTER BREAK DISCONNECTOR
SBEVERTICAL BREAK DISCONNECTOR
MR164EUNIVERSAL SMART
DRIVE
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-OFTPORTABLE
DIAGNOSTIC TOOL
S-COM REMOTE CONTROL
BOARD
The drawing above is given for information only. Detailed layout and digital drawing available on request.
354±10
202±5 42±10
MANIVELLE DE SECOURSCRANK EMERGENCY
- PLAQUE EN ALUMINIUM EP.2 PRESSE ETOUPE FOURNIE NON PERCEE- CABLE GLAND PLATE IN ALUMINIUM SUPPLIED WITHOUT HOLES- PRESSE ETOUPE NON FOURNI PAR SDCEM- CABLE GLAND NOT SUPPLIED BY SDCEM- COFFRET EN INOX - STAINLESS STEEL CUBICLE - COURSE DE LA MANOEUVRE 90°- ANGULAR STROKE 90°- VERROUILLAGE DU COFFRET PAR CADENAS EN STANDARD- LOCK BOX WITH LOCK IN STANDARD- IP 56- POIDS / WEIGHT: 30kg
BOUTON POUSSOIR LOCALLOCAL PUSH BUTTON
115
140
±1
224
±1
198±1 103±1
4 ECROUS M124 NUT M12
460±10
66±5
500
±10
245±5
56±5 240
91
173
±5 2
74±5
334
MISE A LA TERREEARTHING CONNECTIONM10
PLAQUE PRESSE ETOUPECABLE GLAND PLATE
AXE SORTIE A GAUCHEOUTPUT SHAFT LEFT
AXE VERTICALVERTICAL SHAFT AXE SORTIE A DROITE
OUTPUT SHAFT RIGHT
BORNIER DERACCORDEMENTTERMINAL CONNECTION
MR41E
A3 1:5 1/2 N°
REVISION
05DATE MODIFICATION DESSINE / BY
09/06/2015 118480 GDX GDXSB
VIF - FRANCE
Statut :
APPROUVE / APPROVEDVERIFIE / CHECKED
Libellés / Titles :
SEULS LES DOCUMENTS REMIS ENCONFIRMATION DE COMMANDE NOUSENGAGENT POUR EXECUTION CONFORMEONLY DOCUMENTS SUBMITTED ASORDER MAY BE CONSIDERED AS BINDING FOR MANUFACTURIND PURPOSE
PLAN ENCOMBREMENTDIMENSION DRAWING
MR41EVA
Non
Non
57708SDCEMPAGE /SHEETEch. / Scale:
CE DOCUMENT, PROPRIETE DE SDCEMNE PEUT ETRE NI COMMUNIQUENI UTILISE SANS SON AUTORISATION THIS DRAWING IS THE SOLE PROPERTY OF SDCEM ANY REPRODUCTION OR USE IS PROHIBITED WITHOUT WRITTEN PERMISSION
OP
ERA
TIN
G D
RIV
ES
MR164EELECTRICAL OPERATING MECHANISM / UNIVERSAL SMART DRIVE
MAIN FEATURES
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Reliable, powerful and cost effective• 6000 units operating worlwide• Robust design, suitable for harsh environmental conditions (humidy, heat, cold, corrosive atmosphere, ..)• Easy to install: compact, lightweight, reduced installation time• Real time condition monitoring (native IED, embedded sensors, Plug&Play options)• Perfect for existing swicthes motorization or remotorization.
FP096d 2018-08
CUSTOMER BENEFITS• Universal smart dive: flexible configuration• Plug and play, easy wiring• Increased grid safety: early detection of mechanical or electrical failures• Condition based maintenance (CBM) / predictive maintenance of HV switches and operating mechanism• Smart grid ready, fully IEC61850 compliant• On site condition assesment / self diagnosis
CONTROL & MONITORING
COMMUNICATION
BASE OPTIONInterfaces Copper wires RS232 / RS485 / fiber optics
Protocol Analog Digital : S-COM (Modbus RTU, Modbus TCP, IEC61850, ..)
Priority mode Analog Dual mode: analog digital automatic switch
CONDITION MONITORING
Torque monitoring of the HV switch
S-TORQUE: low / mean / max torque, alert on output relay / through IT network
Light display on the box S-LUXInside humidity S-WET hygrometerInformation record Last operation parameters S-MEMORY: data recorder10 leds display for operational informations status
3-digits display with informations code and 10 parameters menuV S
S-DIGIT
Operating mechanism automatic self diagnosis
More than 90 real-time monitored operational parameters: Operation counter ü real time monitored alert on output relay / through IT network Motor overload ü real time monitored alert on output relay / through IT network Inside temperature ü real time monitored alert on output relay / through IT network
Low / Mean / Max motor voltage supply ü real time monitored alert on output relay / through IT network
Low / Mean / Max operating current ü real time monitored alert on output relay / through IT network
Presence of auxiliary supply ü real time monitored alert on output relay / through IT network
Anticondensation heater health ü real time monitored alert on output relay / through IT network
Anticondensation heater power supply ü real time monitored alert on output relay / through IT network
Operating time ü real time monitored alert on output relay / through IT network Interlock ü real time monitored alert on output relay / through IT network Selector position (local/ remote/out of use/manual) ü real time monitored alert on output relay / through IT network
Operation in progress (opening / closing) ü real time monitored alert on output relay / through IT network
OTHERS: Electrical / Mechanical interlock, Internal light, Padlockable door / selector, door switch …
OP
ERA
TIN
G D
RIV
ES
MR164E
OUTLINE DRAWING
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, t
he in
form
atio
n in
thi
s do
cum
ent
is s
ubje
ct t
o ch
ange
with
out
notic
e.
TECHNICAL FEATURESMECHANICAL
BASE OPTION
Drive / Transmission mecha-nism
Electrical motor, non-reversible mechanism -
Operating angle 90° -Operating time <10 s Other value upon requestOutput shaft position left / right / vertical -Output torque 1 000 N.m 2 000 N.mMechanical endurance 2000 cycles 20000 cycles, other value upon requestOperating temperature - 25°C / + 40°C On requestDimensions 350 x 340 x 670 mm -Weight -Protection degree IP56 -
ELECTRICAL
BASE OPTIONMotor Power supply voltage 48 to 220 VDC / 60 to 400 VAC On request Frequency range DC / 16 Hz 2/3 / 50 Hz /60 Hz - Nominal power 300 W -Auxiliary supply voltage 48 to 220 VDC / 110 to 230 VAC On requestAuxiliary contacts O/C NO/NC 8O / 8C xO / xC / xNO / xNC upon requestAnticondensation heater Supply voltage 230 VAC 110 VDC Nominal power 25 W 100 WOutput relays 2 Up to 5EMC IEC61000 On request
RELATED EQUIPMENT
SR16200 CENTER BREAK DISCONNECTOR
SBEVERTICAL BREAK DISCONNECTOR
MR164EUNIVERSAL SMART
DRIVE
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-OFTPORTABLE
DIAGNOSTIC TOOL
S-COM REMOTE CONTROL
BOARD
The drawing above is given for information only. Detailed layout and digital drawing available on request.
OR
GA
NES
DE
MA
NEO
UV
RES
R77EMAIN FEATURES
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Manual operating mechanism with local operation, for outdoor disconnectors with connected or not connected poles.• For disconnector : Center break, double break, earthing switch.
TECHNICAL FEATURES
FP009d 2018-09
Based and operating lever made with hot dip galvanized steel
Operating lever
Length of lever 1000 mm
Maximum force 450 NMechanical locking in «open» and «closed» position With padlock (padlock not supplied)
Rotating angle 90°Weight 10 kg
MECHANICAL
OPTIONAL DEVICES
Auxiliary contacts
4NO + 4NC6NO + 6NC/8NO + 8NCInsulation level: 2 kVRated current: 10 ABreaking capacity: 110 Vdc/1ABreaking capacity: 220Vdc/0,3ABreaking capacity: 220 Vac/2A
Heating resistance 230 Vac - 50/60 Hz with or without thermostat
Terminal block, marking off upon request
Electro-magnetic lock with or without push-button and with or without signalling lamp
Locking with keylocks (keylocks not supplied)Box protection degree IP43 (with options above), with cable gland plates (to drill on site).
MANUAL OPERATING MECHANISM
OP
ERA
TIN
G D
RIV
ES
R77EOUTLINE DRAWING
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, t
he in
form
atio
n in
thi
s do
cum
ent
is s
ubje
ct t
o ch
ange
with
out
notic
e.
RELATED EQUIPMENT
SR16200 CENTER BREAK DISCONNECTOR
SBEVERTICAL BREAK DISCONNECTOR
MR41EELECTRICAL
OPERATING DRIVE
ST36001EARTHING SWITCH
MR41RELECTRICAL
OPERATING DRIVE
SBR ROCKING
DISCONNECTOR
345
739
R=86
0
LAMP
PUSH BUTTON
90° TO OPEN
WALL THICKNESS OF SUPPORT
SIGNALLING BOX
PADLOCKING DEVICE
147
REMOVABLE CABLEGLAND PLATE. BOTTOM VIEW
The drawing above is given for information only. Detailed layout and digital drawing available on request.
OP
ERA
TIN
G D
RIV
ES
T70MAIN FEATURES
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Manual operating mechanism with local operation, for outdoor disconnectors with gang operated or one pole operated.• For disconnector : Center break, double break, earthing switch.
TECHNICAL FEATURES
Based and operating lever made with hot dip galvanized steel operating lever
Operating lever with two horizontal handles
Length of lever 500 mm Maximum force 450 NMechanical locking in «open» and «closed» posi-tion With padlock (padlock not supplied)
Rotating angle 180°Output shaft stroke 190 mmWeight 14 kg
MECHANICAL
FP006c 2018-09
OPTIONAL DEVICES
Auxiliary contacts
4NO + 4NC6NO + 6NC/8NO + 8NCInsulation level: 2 kVRated current: 10 ABreaking capacity: 110 Vdc/1ABreaking capacity: 220Vdc/0,3ABreaking capacity: 220 Vac/2A
Heating resistance 230 Vac - 50/60 HzElectro-magnetic lock with or without push-button and with or without signalling lampLocking with keylocks (keylocks not supplied)Box protection degree IP43 (with options above), with cable gland plates (to drill on site)
MANUAL OPERATING MECHANISM
OP
ERA
TIN
G D
RIV
ES
T70OUTLINE DRAWING
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, t
he in
form
atio
n in
thi
s do
cum
ent
is s
ubje
ct t
o ch
ange
with
out
notic
e.RELATED EQUIPMENT
SR16200 CENTER BREAK DISCONNECTOR
SBEVERTICAL BREAK DISCONNECTOR
MR41EELECTRICAL
OPERATING DRIVE
ST36001EARTHING SWITCH
MR41RELECTRICAL
OPERATING DRIVE
SBR ROCKING
DISCONNECTOR
The drawing above is given for information only. Detailed layout and digital drawing available on request.
OP
ERA
TIN
G D
RIV
ES
OPTIONNAL
OPTIONNAL
OPTIONNAL
OPTIONNAL
OPTIONNAL
FLEXBALLFLEXIBLE TRANSMISSION FOR MV & HV SWITCHES
MAIN FEATURES
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Ideal for railways tunnel installation: flexible transmission system perfectly suits tunnel wall and complex installations, allowing safe circulation of rolling stock.• SDCEM is the world reference of switches with flexible transmission since 1990 (more than 12 millions hours without any failure).• It can be spatially laid on all the three dimensions (up to 180° in one loop).• It can operate in severe environmental conditions such as moisture, condensation or icing, without impact on performance.• Temperature variations have no effect on flexible transmission.
FP117b 2018-08
TECHNICAL FEATURES
CUSTOMER BENEFITS• Robust and reliable: stainless steel components.• Easy installation: ideal for tunnels or complex HV switch metallic structure (mast, portals).• High mechanical efficiency .• Maintenance free: no maintenance or lubrication is necessary.
COMMUNICATION
Mechanical efficiency up to 97%
Temperature range -50°C to +120°C
Minimum bending radius 200mm / 250mm
Push load up to 2 500 N
Pull load up to 15 000 N
Example of installation Flexball Tunnel Solution
Tunnel Solution
FLEXBALL
OUTLINE DRAWINGS
OP
ERA
TIN
G D
RIV
ES
FLEXBALL
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com Due
to
prod
uct
evol
utio
ns, t
he in
form
atio
n in
thi
s do
cum
ent
is s
ubje
ct t
o ch
ange
with
out
notic
e.
PRODUCT ON SITE
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-VOLTVOLTAGE DETECTOR
S-COM REMOTE CONTROL
BOARD
Flexball on sao Paulo Metro L5
RELATED EQUIPMENT
SBEVERTICAL BREAK DISCONNECTOR
MR164EUNIVERSAL SMART
DRIVE
MR41EUNIVERSAL SMART
DRIVE
OP
ERA
TIN
G D
RIV
ES
S-COMREMOTE CONTROL BOARD - OPTIMIZED CONTROL & MONITORING
S-COM is a control board fully integrated to smart operating drives MR41E / MR164E for remote control and monitoring of MV / HV switching units throughout their operational life.• Set in factory, S-COM allows secured operation of switching unit and quick information
sharing (through standard and secured protocols) and insures interoperability with existing equipments and smart grids, allowing future modernization and HV IED grid integration.
• Designed according to IEC 62271-1, IEC 62271-102, IEC 60870-3 and EN 50121-1-2-5.
BENEFITS
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
• Reduced integration costs of remote control unit with switches operating drive• Reduced integration costs within control network• Improved operation and maintenance of switches giving an access to many more
parameters than a classical remote control unit (see MONITORING)• Self-powered, no need for additional power supply• Plug & play• Network redundancy available• Easy upgrade of switch operating drive (MR41E/MR164E) in smart grid networks
INTEGRATION IN CONTROL & COMMAND NETWORK
IEC 61850 Server - MMS (IEC 61850-8-1),no goose nor simple values
Logical nodes & data objects (IEC 61850-7-4):XSWI (mandatories)Development upon request : optionals SSWI and/or SOPM
IEC 60870-5-101/104 According to customer profile Customization upon request
MODBUS TCPAccording to specific SDCEM registers (STB167) and more upon request
Operating time, Motor current, TemperatureHumidity, Operating torque…
MODBUS RTUAccording to specific SDCEM registers (STB167) and more upon request
PROTOCOLS
MONITORING
Information list is variable according to protocol and operating drive options.
Monitoring parameters(examples)
Auxiliary voltageMotor voltageMotor currentOperating drive temperatureOperating drive humidity levelOperating times (opening and closing)Operation counterSwitch in motionSwitch exact position
Operating torqueOver-torqueUnder-torquePower supply failureAnti-condensation heating resistance testMotor overloadAlarms / warningMaintenance reminder...
S-COM allows a remote monitoring of many more switch parameters than a classical remote control unit.
FP071c 2016-07
CO
NTR
OL
& M
ON
ITO
RIN
G
S-COMEXAMPLE OF INTEGRATION
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com FP071c 2016-07
TECHNICAL FEATURES
Operating conditions Adapted to all conditions including tropical, cold, humid environmentsRelative humidity 5% to 95%Operating temperature -25°C / +60°C
Power supply Self-powered by electrical drive MR41E / MR164E
Physical support 1 Ethernet port RJ45 CAT5 cable
Option: Fiber Optics connexion + media converter Option : RS485 serial
Network typology Point to point Option : star, ring (closed) or repeaterEMC Protection IEC 62271-1, IEC 62271-102, IEC 60870-3 and EN 50121-1-2-5
CO
NTR
OL
& M
ON
ITO
RIN
G
ASSOCIATED SOLUTIONSIMPROVED RELIABILITY - COST-EFFECTIVE OPERATION & MAINTENANCE
MR41EUniversal Smart Drive
S-OFTPortable Diagnostic Tool
S-TORQUEPrevention of mechanical failures
Due
to
prod
uct
evol
utio
ns, t
he in
form
atio
n in
thi
s do
cum
ent
is s
ubje
ct t
o ch
ange
with
out
notic
e.
S-COM Protocol MODBUS TCP, physical support RJ45
S-TORQUEPREVENTION OF MECHANICAL FAILURES - TORQUE & POSITION MONITORING
S-TORQUE included in MR41E or MR164E is recommended for condition monitoring of all disconnector and switch brands to guarantee safe opening and closing by real time torque & position monitoring of complete equipment (active parts, mechanism and auxiliaries).
• Early detection of torque variation and position issues• Detect and prevent failures of disconnectors, linkage• Improved safety: redundancy of position, torque and auxiliary switch indication
ensure to get the right information and avoid critical situations • Minimise unplanned outages, and avoid major repair costs or collateral damage• Condition based maintenance: optimize (anticipate / postpone) inspection and
maintenance period• Reliability-centered maintenance / Predictive maintenance lessons learn enabled
by S-Torque technical database• Increase equipment lifetime: easy upgrade of “old” equipment with operating
drive MR41E / MR164E with S-TORQUE option
BENEFITS
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
CO
NTR
OL
& M
ON
ITO
RIN
G
• Simple, no assembly on site required• Robust design• Cost effective• Increased equipment reliability and availability • Improved network safety: equipment stops automatically if critical issue appears,
reducing equipment risk and guaranteeing operation within safe limits • Reduced failure rates (estimated 70%) • Reduced maintenance costs (estimated 30%)• Quick and easy recording of the reference curves: 3 minutes operation on site
(using S-OFT software).
FEATURES
Detection and prevention
Disconnector failure Linkage failure Linkage destruction due to vandalismFailures in operating mechanism Misalignment
Torque monitoring
Detection of the mechanical assembly «signature» of each disconnector or load break switch during opening or closing operation of the equipment. Torque signature is repeated for each operation.Each mechanical variation is detected by torque variation.
Position monitoring
Precise indication of the position : 90 measurement points during opening or closingRedundancy with operating mechanism auxiliary contactsCombined real time analysis of equipment torque and position Ensure operation completion
Information outputReading dedicated torque curves on local solftware (S-OFT) : each disconnector assembly with its linkage and operating mechanism has its own torque opening and closing signature (no “standard” torque curve set in factory)
MONITORING
FP089c 2016-11
Network safetyAccording to customers needs, equipment can be automatically stopped when critical issue appears, reducing equipment risk and guaranteeing operation within safe limits
Local alarm On local 3-digit displayOption S-LUX : additional visual alarmwith continuous or fl ashing red light on the operating mechanism
Remote alarm Output relay Option S-COM : digital information via secured protocol (Modbus RTU/TCP, IEC61850….)
SECURITY / ALARMS
S-TORQUEOVERVIEW OF TORQUE MONITORING
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
TECHNICAL FEATURES
GENERAL FEATURES
CompatibilityEmbedded in MR41E / MR164E smart operating drives with possible upgrade of existing drivesSuitable for disconnectors and switches of any sizeUndertorque alarms available according to switch type and installation (contact us for more details).
Easy local access Access to torque curves of each disconnector installation with linkage and operating mechanismAcces to last operation curves, compared with reference curve (using S-OFT software)
Reliability Self-diagnostic to detect internal failure
Flexibility
Setting parameters can be fully customized : Torque detection sensitivityAlarm levels : +X% (overtorque) and -Y% (undertorque)Different alarm levels for opening and closingAcceptability zone : 10% to 200% of reference curveCustomizable settings confi guration
Operating life time up to 50 000 cycles
INSTALLATION FEATURES
Easy installation
Delivered with operating mechanism (factory installed)No assembly required on siteNo external sensorsNo wire connexionNo power supplyMaintenance free solution
Setting information
Torque reference curve 1st measure to be completed on site, after complete installation and adjustment of switching equipment.Quick and easy recording / reset of reference curves : 3 minutes operation on-site
Setting by SDCEM fi eld technician or by your maintenance team (using S-OFT software)
S-TORQUE : monitoring screen and example of security configurations
ASSOCIATED SOLUTIONSIMPROVED RELIABILITY - COST-EFFECTIVE OPERATION & MAINTENANCE
MR41EUniversal Smart Drive
S-COMRemote control board
CO
NTR
OL
& M
ON
ITO
RIN
GD
ue t
o pr
oduc
t ev
olut
ions
, the
info
rmat
ion
in t
his
docu
men
t is
sub
ject
to
chan
ge w
ithou
t no
tice.
S-OFTPortable Diagnostic Tool
EXAMPLE OF CUSTOMIZATION
overtorque level reached + operating time ≤ 10’’ Warning Switch can still
operate
Inspection should be done during the next planned maintenance
overtorque level reached + operating time > 10’’ Critical alarm Switch must not
be operated.Inspection must be done immediately
undertorque level reached Critical alarm Switch must not be operated.
Inspection must be done immediately
S-VOLTVOLTAGE PRESENCE DETECTOR FOR AC AND DC RAILWAY NETWORKS
• Voltage presence detector for indoor & outdoor application, for AC and DC networks• Secure your network and your maintenance operations with S-VOLT• Install S-VOLT next to HV switches for safe maintenance operations• Interlock voltage presence detection directly to HV switch operating mechanism for • safety increase • Provide visual alarm of voltage presence to maintenance teams• Intrinsic safety functioning: in case of internal failure or lack of power supply, contacts • are deenergized thus allowing to discriminate the device failure in both cases of voltage • presence or voltage absence
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
CO
NTR
OL
& M
ON
ITO
RIN
G
TECHNICAL FEATURES
PRODUCT NETWORK SENSOR
S-VOLT 1500 For 750 VDC & 1500 VDC systems Voltage presence relay
S-VOLT 3000 For 3000 VDC systems Voltage presence relay
S-VOLT 25 For 25kVAC systems Capacitive sensor
BUILD YOUR OWN SOLUTION
FP120b 2018-08
MAIN FEATURES
BASE OPTIONSVoltage presence sensor: 1 2
Casing
+ Protection fuses
+ Ground protective relay 64
+ Light indicator on casing (S-LUX) green/red/flashing red
+ Direct interlock to HV switch operating mechanism
+ Output on relays contacts
+ Connection to SCADA through Modbus protocol (using S-COM communication card in HV switch operating mechanism)
TECHNICAL DATA
Input scale Un 750VDC, 1500VDC, 3000 VDC, 25kVAC
Supply voltage From 48 to 230 VAC/DC
Installation Outdoor & indoor
Operating time <20 ms
Casing protection IP55
Accuracy ± 5% Un
Operating temperature -25 to +70 °C
Dielectric rigidity S-VOLT 1500 & 3000 10 kVAC 50 Hz 1 minS-VOLT 25 95 kV AC 50 Hz 1 min
Output contactsVoltage detection (per sensor): ON: 1NC / OFF: 1NCFuse status (diagnostic): 1NCGround protective relay 64: 1NC
Standards EN 50124
S-VOLTOUTLINE DRAWINGS
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
S-Volt (without S-Lux option)
CO
NTR
OL
& M
ON
ITO
RIN
GD
ue t
o pr
oduc
t ev
olut
ions
, the
info
rmat
ion
in t
his
docu
men
t is
sub
ject
to
chan
ge w
ithou
t no
tice.
101
±2
FIX
605
±1
25
695
±2
420 ±2
FIX 4 X 13
440 ±2
S-LUX 5
635
±2
70
339 ±2
14EARTHING
CATENARY
OPERATING MECHANISMMR41E
SDCEMDISCONNECTOR
S-VOLT
CAPACITIVE SENSOR BCAPACITIVE SENSOR A
RELATED EQUIPMENT
SBI/SBIFBVERTICAL BREAK DISCONNECTOR
SBEVERTICAL BREAK DISCONNECTOR
MR41EUNIVERSAL SMART
DRIVE
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-OFT - PORTABLE DIAGNOSTIC TOOL
S-COM REMOTE CONTROL
BOARD
For information only : Dimension can vary depending on the options
S-OFTPORTABLE DIAGNOSTIC TOOL FOR DISCONNECTORS AND SWITCHES
Plug & play software for diagnostics, condition monitoring and commissioning assistance for disconnectors and switches equipment with MR41E / MR164E. Ideal for condition-based maintenance.•Reduced inspection time •Quick diagnostics & trouble shooting
Increased grid availability with S-OFT diagnostic tool based on switches real-time condition monitoring :•Automated inspection tasks reducing maintenance time and costs•Asset aging management / life time increase•Condition-based maintenance / preventive maintenanceLocal access to installation advanced functions and administration of maintenance database. Values and performances are collected, stored in internal database and real time viewed on the local display screen.
BENEFITS
10, allée des Plantées • 38450 Vif • France •Tel : +33 (0)4 76 72 76 72 • [email protected] •www.sdcem.com
CO
NTR
OL
& M
ON
ITO
RIN
G
•Fully portable and economical• Immediate access to 90 operating parameters•Switches and operating drive condition monitoring •Complete operating mechanism and switch diagnostic report•Multiple curves display during switch operation for condition analysis•Commissioning assistance and options setting
FEATURES
Viewing operating data(over 90 operating & self-monitoring values)
Operating time (opening / closing)Disconnector / switch positionOperation CounterMotor voltageMotor currentMotor overloadMotor voltage frequenceAuxiliary voltageOperating drive temperatureOperating drive humidity levelHeating resistance voltageHeating resistance healthLimit switch positionSelector positionCurrent drift warning...
Information on last events
OperationsIssuesWarning / AlarmsParameter settingAlarm setting
Access to last maintenance comments
Inspection / Maintenance DateNomber of operating hours statedNumber of operating cyclesTechnical comments
Alarm configuration Configuratedinfactoryaccordingtocustomersneeds
Setting of options
S-TORQUE : over torque and under torque alarm levelsS-COM : remote control boardS-OUT : additionnal relaysS-WET : hygrostatS-LUX : light alarm indicator
Assistance Optional : On-site training
EASE OF USE
FP104b 2016-07
S-OFTSCREEN SHOTS
10, allée des Plantées • 38450 Vif • France •Tel : +33 (0)4 76 72 76 72 • [email protected] •www.sdcem.com FP104b 2016-07
TECHNICAL FEATURES
SOFTWARE DATA
Compatibility Adapted to any installation equipped with MR41E / MR164E operating drive (upgrade possible)For computer operating systems : Windows 2000 / XP / Vista / 7, 32-64 bits
Multilingual Interface in English or French
Data and report Extract in excel (CSV) or PDF formats
Licensing Userlicenceperoperatingdriveconfiguration,singleormultiple
SCOPE OF SUPPLY
USER KIT including
Diagnostic software+ USB cable (operating drive connexion)+ installation & user manual+ licence
USER KIT + OPTION
Pre-installed diagnostic software+ USB cable (connexion between operating drive and PC)+ installation & user manual+ licence+ Mobile computer & rugged case
S-OFT Diagnostic tool user interface
ASSOCIATED SOLUTIONSIMPROVED RELIABILITY - COST-EFFECTIVE OPERATION & MAINTENANCE
MR41EUniversal Smart Drive
S-COMRemote control board
S-TORQUEPrevention of mechanical failures
CO
NTR
OL
& M
ON
ITO
RIN
GD
ue t
o pr
oduc
t ev
olut
ions
, the
info
rmat
ion
in t
his
docu
men
t is
sub
ject
to
chan
ge w
ithou
t no
tice.
S-LUXLIGHT ALARM / INFORMATION STATUS
• S-LUX- Light Alarm / information status is a warning light device fixed on the top of the• EOM MR41E, which gives to the on-site operators a visual information on the status of the • EOM thanks to a color code.• This S-LUX module can detect and alert about any minor or major default before or when • the default arises, which makes the operation and maintenance much easier and more • reliable for the operators. For example, it can inform about a necessary maintenance to • be done on the EOM, according to the maintenance cycle the user configurates at its• convenience
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
CO
NTR
OL
& M
ON
ITO
RIN
G
TECHNICAL FEATURES
FP086c 2018-08
MAIN FEATURES
Customized to meet your needs or standard version
Visual field up to 50 meters
Life time 100 000 hours
Reported information Overload, maintenance, troubles… to be defined according to customer’s needs
IP65 box for light cabinet
Color no light, green, red, flashing red
S-LUX
PRODUCT ONSITE
10, allée des Plantées • 38450 Vif • France • Tel : +33 (0)4 76 72 76 72 • [email protected] • www.sdcem.com
S-LUX at Champagnier, France
CO
NTR
OL
& M
ON
ITO
RIN
GD
ue t
o pr
oduc
t ev
olut
ions
, the
info
rmat
ion
in t
his
docu
men
t is
sub
ject
to
chan
ge w
ithou
t no
tice.
RELATED EQUIPMENT
SR16201HDOUBLE BREAK DISCONNECTOR
SR16200CENTER BREAK DISCONNECTOR
SBEVERTICAL BREAK DISCONNECTOR
S-TORQUE MECHANICAL FAILURE
AND POSITION DETECTION
S-VOLTVOLTAGE DECTEOR
FOR RAILWAY DS/LBS
S-POSITION DISCONNECTOR
POSITION INDICATOR
SDCEM
WO
RLD
WID
E SDCEM WORLDWIDE
SDCEM FRANCE(HEAD OFFICE)
10, allée des Plantées38450 Vif
Tel: +33 476 72 76 72Mail: [email protected]
SDCEM SPAIN
Aurela Industrias Electricas C/ Cristóbal Bordiú 35 Planta 6, Oficina 605 28003 Madrid
Tel: +34 91 728 2040Mail: [email protected]
SDCEM CHINA
SidiximuBuilding 1 - Furunyuan, YihaihuayuanFengtai District Beijing 100070
Tel: +86 13 90 114 92 95Mail: [email protected]
WORLDWIDE PARTNERS & DISTRIBUTORS
Algeria - Australia - Belgium - Brazil - Bulgaria - Chili - Colombia India - Luxembourg - Morocco - Peru - Romania - Saudi Arabia - South Korea - United Arab Emirates - United Kingdom
Follow us: fr.linkedin.com/in/sdcemin
•