MAY 2014 PRICES SUBJECT TO CHANGE DIN Rail Power Supplies TRC ELECTRONICS, INC. Providing exceptional customer service since 1982 T 215.367.5124 F 215.367.5431 Toll Free 888.612.9514 www.trcelectronics.com AC/DC 12~960 Watts KHEA120F KHEA90F KHEA60F KHEA30F KHEA240F KHEA480F DR-30 DR-60 DR-15 DR-100
12
Embed
DIN Rail Power Supplies - Control Design€¦ · DIN Rail Power Supplies TRC ELECTRONICS, INC. Providing exceptional customer service since 1982 T 215.367.5124 F 215.367.5431 Toll
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
MAY 2014PRICES SUBJECT TO CHANGE
DIN Rail Power Supplies
TRC ELECTRONICS, INC.Providing exceptional customer service since 1982
T 215.367.5124 F 215.367.5431 Toll Free 888.612.9514 www.trcelectronics.com
AC/DC 12~960 Watts
KHEA120F
KHEA90FKHEA60FKHEA30F
KHEA240F KHEA480F
DR-30DR-60
DR-15
DR-100
T 215.367.5124 F 215.367.5431 Toll Free 888.612.9514 www.trcelectronics.com1
TRC Electronics History
1982 On April 16th, 1982, TRC Electronics is established in Lodi, New Jersey with the goal of providing OEMs: Troubleshooting, Repair and Calibration services for power supplies.
1984-1992 TRC Electronics becomes a leader in the power supply industry by evolving into one of the first electronic distributors to specialize exclusively in power supply solutions. 1998 TRC Electronics launches one of the very first websites dedicated to power supplies. TRC’s website becomes the leading destination for engineers and buyers to source their power supply needs.
2011 In June of 2011, TRC Electronics opens its west coast sales office in Campbell, CA. Our California office positions TRC to better serve the west coast market. During the month of December, that same year, TRC relocates its stocking headquarters to Montgomeryville, Pennsylvania. The new 17,000 square foot facility greatly increases our ability to meet our customers’ stocking demands.
2012 TRC celebrates its 30th year in business. We are proud to be partners with the more than 20,000 companies that TRC Electronics has served.
Company Profile
TRC Electronics, Inc. - a privately owned company - is the industry’s leading stocking distributor of power supply and power supply related products serving North America. Since 1982, TRC has been lending power supply expertise to the electronic manufacturing industry.
TRC Electronics Mission
A core principle at TRC is the belief that you deserve the finest personalized customer service and we aim to provide it. Our team of professionally trained experts is ready to assist design engineers and buyers on the latest power supply products. Imagine speaking to a customer service representative that can provide answers to all of your product/technical questions and enter your order efficiently. We save our customers time and money. We’ll provide the ideal power supply solution, in the timeliest manner at the highest customer service level possible. This has been our commitment for more than 30 years.
TRC Electronics, Inc. 101B Domorah Drive Montgomeryville, PA 18936 T 215.367.5124 F 215.367.5431.. . .West Coast Sales Office Northern California Toll Free 888.612.9514. .
TRC Electronics headquarters is located in Montgomeryville, Pennsylvania.
T 215.367.5124 F 215.367.5431 Toll Free 888.612.9514 www.trcelectronics.com 2
Features (DR-15 / -30 / -60 / -100) • UL60950-1 approved DIN rail power supply • AC input range: 85~264 VAC (DR-15 / -30) 88~264 VAC (DR-60 / -100) • Operating temperature range: -20~+60°C • Standard Protections: short circuit / overload / over voltage • Overload protection is constant current limiting • No load power consumption: <1W (DR-100) • No load power consumption: <0.5W (DR-15) • Isolation Class II power supply • LED indicator for power on • 3 year Mean Well warranty
TRC ELECTRONICS, INC.
Class II DIN Rail Power Supply, 12~100WMean Well DR Series
Since 1982, TRC Electronics has been providing our customers the finest customer service in the industry. Our friendly and knowledgeable sales team will provide the ideal power supply for your application.
TRC Electronics has been providing exceptional customer service for over 30 years !
T 215.367.5124 F 215.367.5431 Toll Free 888.612.9514 www.trcelectronics.com3
DIN Rail Power Supply, 25~480WMean Well DR/DRP Series
TRC ELECTRONICS, INC.
Features (DR-45 / -75 / -120, DRP-240 / -480S) • AC input range: 85~264 VAC (DR-45 / -75 / DRP-240) 90~132 VAC/180~264 VAC (DR-120, DRP-480S - selected by switch) • Operating temperature: -10~+50°C (DR-45); -10~+60°C (DR-75 / -120) -10~+70°C (DRP-240); -20~+70°C (DRP-480S) • UL 508 Listed • Protections: short circuit / overload / over voltage / over temperature • LED Indicator for Power On • Built-in active PFC function (DRP-240 only) • 3 year Mean Well warranty
T 215.367.5124 F 215.367.5431 Toll Free 888.612.9514 www.trcelectronics.com 4
AC/DC DIN Rail Power Supply, 25~480WCosel KHEA Series
TRC ELECTRONICS, INC.
Features • AC input range: 85~264 VAC • Operating temperature: -20~+70°C (KHEA30F / 60F / 90F); -25~+70°C (KHEA120F / 240F / 480F) • Safety approvals: UL508 (industrial control equipment), UL60950-1, EN50178, EN60950-1, CE, ANSI/ISA12.12.01 (Class 1 Div.2) • NEC Class 2 per UL1310 (KHEA30F / 60F) • Built-in active PFC (KHEA90F / 120F / 240F / 480F) • Output voltage trim on front of DIN rail power supply • Digital control for highest efficiency in market: up to 94% • LED indicators for DC OK (KHEA30F / 60F / 90F) • LED indicators for DC OK and ALARM (KHEA120F / 240F / 480F) • DC OK contact (KHEA120F / 240F / 480F) • Built-in remote ON/OFF (KHEA120F / 240F / 480F) • Standard Protections: overload / over voltage • Over temperature protection (KHEA120F / 240F / 480F) • 5 year Cosel warranty
Features • Three-phase AC 340~550 VAC wide range input • Operating temperature range: -30~+70°C • UL 508 (industrial control equipment) listed • Extremely high efficiency up to 94.5% • Built-in active PFC function • Protections: short circuit / overload / over voltage / over temperature • Current sharing up to 4 TDR-960, 3840W (3+1) • Cooling by free air convection • Built-in constant current limiting circuit • DC OK relay contact • 3 year Mean Well warranty
Wide Input Range DIN Rail Power Supply, 120~480WMean Well WDR Series
Features • AC input voltage: 180~550 VAC, single and two phase • Operating temperature: -25~+70°C (WDR-120); -30~+70°C (WDR-240 / -480) • Built-in active PFC (WDR-240 / -480) • Protections: short circuit / overload / over voltage / over temperature • Built-in constant current limiting circuit • UL508 Approved (industrial control equipment) • Built-in DC OK relay contact • 3 year Mean Well warranty
T 215.367.5124 F 215.367.5431 Toll Free 888.612.9514 www.trcelectronics.com7
Slim Type DIN Rail Power Supply, 10~96WMean Well MDR Series
Features • AC input range: 85~264 VAC • Operating temperature: -20~+70°C • Plastic case & recessed screw terminal connections • Over voltage protection • Over load protections: Hiccup mode: (MDR-10) Constant current limiting: (MDR-20 / -40 / -60 / -100) • Low no load power consumption < 0.75W (<1W for MDR-100) • Built-in active PFC (MDR-100 only) • UL 508 listed • LED Indicator for Power On • 3 year Mean Well warranty
T 215.367.5124 F 215.367.5431 Toll Free 888.612.9514 www.trcelectronics.com 8
High Efficiency DIN Rail Power Supply, 75~960WMean Well SDR Series
TRC ELECTRONICS, INC.
Features • AC input range: 88~264 VAC (SDR-75 / -120 / -240) 90~264 VAC (SDR-480) 180~264 VAC (SDR-960) • High efficiency up to 94% • Built-in active PFC function (SDR-120 / -240 / -480 / -960) • Protections: short circuit / overload / over voltage / over temperature • UL508 Approved (industrial control equipment) • Built-in DC OK relay contact (except SDR-75) • 150% peak load capacity (SDR-75 / -120 / -240 / -480) • 130% peak load capacity (SDR-960) • Compliance with SEMI F47 (SDR-75 / -120 / -240 / -480) • Compliance with GL (SDR-120 / -240 / -480) • Current Sharing up to 3840W (3+1) for SDR-960 • 3 year Mean Well warranty
T 215.367.5124 F 215.367.5431 Toll Free 888.612.9514 www.trcelectronics.com9
DC UPS Battery Controller ModuleMean Well DR-UPS40 Series
TRC ELECTRONICS, INC.
Suggested Applications:
Features • Module facilitates UPS connection between 24 VDC power supply & 24 Volt battery • Input: 24 Volt external battery and a separate 24 Volt DC power supply source • Operating temperature range: -20~+70°C • Suitable for 24 VDC system maximum rating 40A • Battery and power supply are not included with DR-UPS40 • Built-in battery test function • Battery polarity protection • Monitoring signals: LED indicator for DC bus OK, battery fail, battery discharge and battery test function to check the condition of external batteries • Customize a DC UPS system to back up critical loads and capture the status of the entire system • Installs on DIN rail TS35 /7.5 or 15 • 3 year Mean Well warranty
T 215.367.5124 F 215.367.5431 Toll Free 888.612.9514 www.trcelectronics.com 10
20A Power Supply Redundancy ModuleMean Well DR-RDN20 Series
TRC ELECTRONICS, INC.
Suggested Applications:
Features • 20A redundancy (decoupling) module for 24 VDC power system • Input voltage range: 21~28 VDC (two separate inputs) • Operating temperature range: -20~+70°C • Containing 2 sets of 20A ORing diodes with great heat dissipation, the DR-RDN20 offers a safe 1+1 redundant set-up • Decouples 24 Volt power sources from each other • Monitoring signals: LED indicator for each input and input voltage alarm • Installs on DIN rail TS35 /7.5 or 15 • 3 year Mean Well warranty
DR-RDN20 21~28 VDC 20A $25.70 $24.50
Specifications Call For Volume Pricing
Mean WellModel #
Input Voltage Range Standard Pricing1pc. 10pcs.
Output Current
1.) 1 + 1 Redundancy. Use 1 additional power supply as the redundant unit.
2.) 1 + N Redundancy. Use additional PSUs as the redundant units to increase reliability.
3.) Single Use: Connecting only one Power Supply to one DR-RDN20 to reduce the stress of the diodes and increase reliability.
SPECIFICATIONMODEL
MTBF
DIMENSION
NOTE
PACKING
1. All parameters NOT specially mentioned are measured at 24VDC input, rated load and 25 of ambient temperature.℃2. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
File Name:DR-RDN20-SPEC 2014-04-16
20A Power Supply Redundancy Module DR - RD N20
■ Features :
OUTPUT
INPUT
OTHERS
ENVIRONMENT
DR-RDN20
REVERSE VOLTAGE (max.)
OUTPUT CURRENT (max.)
VOLTAGE DROP
LED INDICATORS
INPUT VOLTAGE RANGE
NUMBER OF INPUTS
INPUT CURRENT (max.)
INPUT VOLTAGE ALARM
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
VIBRATION
RELAY CONTACT RATING (max.)
30V
20A
0.6V
Two green LEDs indicating each input is "OK or fail"
21 ~ 28V
Two
20A per input
When input is > 20V( 5%) or < 30V( 5%) relay contacts± ±
30VDC, 1A
-40 ~ +70℃
20 ~ 90% RH non condensing
-40 ~ +85 , 10 ~ 95% RH℃
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mouning: Compliance to IEC60068-2-6
FUNCTION
996.8Khrs min. MIL-HDBK-217F (25 )℃
55.5*125.2*100mm (W*H*D)
0.5Kg; 20pcs/11Kg/1.29CUFT
‧Suitable for redundant operation of 24V system
‧Installed on DIN Rail TS35 / 7.5 or 15
‧Relay contact signal output and LED indicator for input failure alarm
EMC(Note 2) Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, heavy industry level, criteria A
PSU
PSU PSU
PSU PSU PSUPSU PSU PSU PSU
LoadLoad
Load
Vout
DR-RDN20
DR-RDN20 DR-RDN20
DR-RDN20 DR-RDN20 DR-RDN20
Vout Vout Vout
Vout Vout
Vin A
Vin A Vin A
Vin A Vin AVin B
Vin B Vin B
Vin B..............
Vin B
1. 1+1 Redundancy
Using 1 more PSU as the redundant unit
3. Single Use: Connecting only one PSU to one DR-RDN20 to reduce the stress of the diodes and hence increase the reliability
2. 1+N Redundancy: Using more PSUs as the redundant units to increase the reliability
Typical Application Notes
EMC IMMUNITY
EMC EMISSION
SAFETY STANDARDS UL508 approved
SPECIFICATIONMODEL
MTBF
DIMENSION
NOTE
PACKING
1. All parameters NOT specially mentioned are measured at 24VDC input, rated load and 25 of ambient temperature.℃2. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
File Name:DR-RDN20-SPEC 2014-04-16
20A Power Supply Redundancy Module DR - RD N20
■ Features :
OUTPUT
INPUT
OTHERS
ENVIRONMENT
DR-RDN20
REVERSE VOLTAGE (max.)
OUTPUT CURRENT (max.)
VOLTAGE DROP
LED INDICATORS
INPUT VOLTAGE RANGE
NUMBER OF INPUTS
INPUT CURRENT (max.)
INPUT VOLTAGE ALARM
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
VIBRATION
RELAY CONTACT RATING (max.)
30V
20A
0.6V
Two green LEDs indicating each input is "OK or fail"
21 ~ 28V
Two
20A per input
When input is > 20V( 5%) or < 30V( 5%) relay contacts± ±
30VDC, 1A
-40 ~ +70℃
20 ~ 90% RH non condensing
-40 ~ +85 , 10 ~ 95% RH℃
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mouning: Compliance to IEC60068-2-6
FUNCTION
996.8Khrs min. MIL-HDBK-217F (25 )℃
55.5*125.2*100mm (W*H*D)
0.5Kg; 20pcs/11Kg/1.29CUFT
‧Suitable for redundant operation of 24V system
‧Installed on DIN Rail TS35 / 7.5 or 15
‧Relay contact signal output and LED indicator for input failure alarm
EMC(Note 2) Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, heavy industry level, criteria A
PSU
PSU PSU
PSU PSU PSUPSU PSU PSU PSU
LoadLoad
Load
Vout
DR-RDN20
DR-RDN20 DR-RDN20
DR-RDN20 DR-RDN20 DR-RDN20
Vout Vout Vout
Vout Vout
Vin A
Vin A Vin A
Vin A Vin AVin B
Vin B Vin B
Vin B..............
Vin B
1. 1+1 Redundancy
Using 1 more PSU as the redundant unit
3. Single Use: Connecting only one PSU to one DR-RDN20 to reduce the stress of the diodes and hence increase the reliability
2. 1+N Redundancy: Using more PSUs as the redundant units to increase the reliability
Typical Application Notes
EMC IMMUNITY
EMC EMISSION
SAFETY STANDARDS UL508 approved
SPECIFICATIONMODEL
MTBF
DIMENSION
NOTE
PACKING
1. All parameters NOT specially mentioned are measured at 24VDC input, rated load and 25 of ambient temperature.℃2. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
File Name:DR-RDN20-SPEC 2014-04-16
20A Power Supply Redundancy Module DR - RD N2 0
■ Features :
OUTPUT
INPUT
OTHERS
ENVIRONMENT
DR-RDN20
REVERSE VOLTAGE (max.)
OUTPUT CURRENT (max.)
VOLTAGE DROP
LED INDICATORS
INPUT VOLTAGE RANGE
NUMBER OF INPUTS
INPUT CURRENT (max.)
INPUT VOLTAGE ALARM
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
VIBRATION
RELAY CONTACT RATING (max.)
30V
20A
0.6V
Two green LEDs indicating each input is "OK or fail"
21 ~ 28V
Two
20A per input
When input is > 20V( 5%) or < 30V( 5%) relay contacts± ±
30VDC, 1A
-40 ~ +70℃
20 ~ 90% RH non condensing
-40 ~ +85 , 10 ~ 95% RH℃
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mouning: Compliance to IEC60068-2-6
FUNCTION
996.8Khrs min. MIL-HDBK-217F (25 )℃
55.5*125.2*100mm (W*H*D)
0.5Kg; 20pcs/11Kg/1.29CUFT
‧Suitable for redundant operation of 24V system
‧Installed on DIN Rail TS35 / 7.5 or 15
‧Relay contact signal output and LED indicator for input failure alarm
T 215.367.5124 F 215.367.5431 Toll Free 888.612.9514 www.trcelectronics.com 05/2014
www.trcelectronics.com/cosel
Cosel KH Series DIN Rail Power Supply
See page 4 for more information on the Cosel KH Series
KHEA90FKHEA60FKHEA30F
KHEA120F KHEA240F KHEA480F
TRC ELECTRONICS, INC.Providing exceptional customer service since 1982
Features • AC input range: 85~264 VAC • Operating temperature: -20~+70°C (KHEA30F / 60F / 90F) -25~+70°C (KHEA120F / 240F / 480F) • Safety approvals: UL508 (industrial control equipment), UL60950-1, EN50178, EN60950-1, CE, ANSI/ISA12.12.01 (Class 1 Div.2) • NEC Class 2 per UL1310 (KHEA30F / 60F) • Built-in active PFC (KHEA90F / 120F / 240F / 480F) • Output voltage trim on front of DIN rail power supply • Digital control for highest efficiency in market: up to 94% • LED indicators for DC OK (KHEA30F / 60F / 90F) • LED indicators for DC OK and ALARM (KHEA120F / 240F / 480F) • DC OK contact (KHEA120F / 240F / 480F) • Built-in remote ON/OFF (KHEA120F / 240F / 480F) • Standard Protections: overload / over voltage • Over temperature protection (KHEA120F / 240F / 480F) • 5 year Cosel warranty
TRC Electronics, Inc. 101B Domorah Drive Montgomeryville, PA 18936 T 215.367.5124 F 215.367.5431.. . .West Coast Sales Office Northern California Toll Free 888.612.9514. .TRC Electronics, Inc. 101B Domorah Drive Montgomeryville, PA 18936 T 215.367.5124 F 215.367.5431.. . .West Coast Sales Office Northern California Toll Free 888.612.9514. .