M A N U A L 1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.) Failure to follow this instruction may result in personal injury, fire, or economic loss. 2. Do not disassemble or modify the unit. Please contact us if necessary. Failure to follow this instruction may result in electric shock or fire. Specifications Operation Mode Caution During Use Ordering Information Control Output Circuit Diagram Warning Caution Dimensions PHOTOMICRO SENSOR BUILT AMPLIFIER BS5 SERIES 1. Check the polarity of the power before wiring the unit. Failure to follow this instruction may result in product damage. Check the cable position and power voltage range. Cut off the power for wiring cables. 2. Do not use the unit where flammable or explosive gas may be present. Failure to follow this instruction may result in fire or explosion. 3. Do not use water or oil-based detergent when cleaning the unit. Failure to follow this instruction may result in electric shock or fire. ●NPN open collector output ●PNP open collector output Model NPN open collector output BS5-K1M BS5-T1M BS5-L1M BS5-Y1M BS5-V1M BS5-K2M BS5-T2M BS5-L2M BS5-Y2M BS5-V2M PNP open collector output BS5- K1M-P BS5- T1M-P BS5- L1M-P BS5- Y1M-P BS5- V1M-P BS5- K2M-P BS5- T2M-P BS5- L2M-P BS5- Y2M-P BS5- V2M-P Sensing type Through-beam (not modulated) Sensing distance 5mm fixed Sensing target 0.8 ×2mm Opaque materials Hysteresis 0.05mm Response time Light ON: Max. 20㎲, Dark ON: Max. 100㎲ Response frequency ※1 2kHz Power supply 5-24VDC ±10% (ripple P-P: Max. 10%) Power supply Max. 30mA (at 26.4VDC) Light source Infrared LED (940nm) Operation mode Light ON, Dark ON selectable by control wire Light ON, Dark ON selectable by control terminal Control output NPN or PNP open collector output • Load voltage: Max. 30VDC • Load current: Max.100mA • Residual voltage: Max. 1.2V Protection circuit Reverse power polarity protection, Overcurrent protection Indicator Operation Indicator: red LED Connection Cable type Connector type Insulation resistance Min. 20MΩ (at 250VDC megger) Noise resistance ±240V the square wave noise (pulse width: 1㎲) by the noise simulator Dielectric strength 1,000VAC 50/60Hz for 1 minute Vibration 1.5mm amplitude at frequency of 10 to 55Hz (for 1 min.) in each X, Y, Z direction for 2 hours Shock 500m/s² (approx. 50G) in X, Y, Z directions for 3 times Environment Ambient illumination Fluorescent lamp: Max. 1,000 (receiver illumination) Ambient temperature -20 to 55℃, Storage: -25 to 85℃ Ambient humidity 35 to 85%RH, Storage: 35 to 85%RH Protection IP50 (IEC standard) Material PBT Cable Ø3mm, 4-wire, 1m (AWG28, Core diameter: 0.08mm, Number of cores: 19, Insulator out diameter: Ø0.88mm) - Approval Weight ※2 Approx. 50g (approx. 30g) 1.6mm 1.8mm Circle panel 1.6mm t=0.2mm ※1: Response frequency is the value getting from revolving the circle panel below. ※2: The weight includes packaging. The weight in parentheses is for unit only. ※The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment. 1. There is no protection of external light source in this unit which is for built-in, please intercept external light source from the receiver. 2. When wiring the photoelectric sensor with high voltage line, power line in a same conduit, it may cause malfunction or mechanical problem, please do wire separately or use different conduit. 3. If there are machines generating noise at surrounding photomicro sensor (Switching regulator, inverter motor etc.), be sure to earth F.G. terminals of machines. 4. For soldering on the connector type terminals, keep the temperature max. 260℃ and do not heat for more than 3 sec. Solder 1.5mm away from terminal source part. 5. Use M3 screws and tighten with max. 0.49N . m (5.0kgf . cm) torque. When screwing, use a flat washer (Ø6). Be sure that sensing part is not to be touched by any objects. If the sensing part is damaged, it may cause malfunction. 6. If the sensor is installed at place where there are a lot of dust and humidity, clear the receiver and the emitter with dry cloth. Pollution of the receiver and the emitter can occur malfunction of the sensor. 7. Do not install the unit at the below environment to prevent from product malfunction or damage. ①Place where heavy steam, or dust may be present. ②Place where water, oil, or chemicals (oil-based detergent, acid alkali, aromatic hydrocarbon, etc.) is directly contacted. ③Outdoor or place where the ray of the sun is directly contacted. 8. This unit may be used in the following environments. ①Indoors ②Altitude: under 2,000m ③Pollution degree 2 ④Installation category II Connection ●Hole cut-out when inputting socket on PCB ●Socket: CT-01 (sold separately) ●Socket: CT-02 (sold separately) Operation mode Light ON Dark ON Receiver operation Operation indicator (red LED) Transistor output Received light Interrupted light ON OFF ON OFF Received light Interrupted light ON OFF ON OFF Major Products No mark NPN open collector output P PNP open collector output M Middle 1 Cable Type 2 Connector Type K K-Type T T-Type L L-Type Y Y-Type V V-Type 5 Unit: mm (fixed) BS Photoelectric sensor series P M 1 K 5 BS Control output Size Connection Appearance Sensing distance Item ※1: Operation mode selection: Connect (White)Control cable (terminal) into terminal (Brown)+V to operate Light ON mode. Dark ON mode is available with disconnection status. Internal circuit External connection (Brown)+V (Black) Output Load Dark ON Over current protection Main circuit Light ON 5-24VDC ±10% Max. 100mA (Blue)0V (White) Control ※1 Internal circuit External connection (Brown)+V (Black) Output Load Dark ON Over current protection Main circuit Light ON 5-24VDC ±10% Max. 100mA (Blue)0V (White) Control ※1 Cable Type Connector Type ※Connect the unit using socket(CT-01, CT-02). If it is soldered on terminal pin directly without socket, it may cause product damage. ①Load connection for NPN output ②Load connection for PNP output Control +V ① ② 0V Output 5-24VDC ±10% + - Light ON Dark ON Load Load (White) Control (Brown) +V ① ② (Blue) 0V (Black) Output 5-24VDC ±10% + - Light ON Dark ON Load Load ●BS5-K1M / BS5-K1M-P ●BS5-T1M / BS5-T1M-P ●BS5-V1M / BS5-V1M-P ●BS5-L1M / BS5-L1M-P ●BS5-Y1M / BS5-Y1M-P ●BS5-K2M / BS5-K2M-P ●BS5-Y2M / BS5-Y2M-P ●BS5-V2M / BS5-V2M-P ●BS5-T2M / BS5-T2M-P ●BS5-L2M / BS5-L2M-P [T-type] [L-type] [K-type] [Y-type] [V-type] ※The above specifications are subject to change and some models may be discontinued without notice. Photoelectric Sensors Temperature Controllers Fiber Optic Sensors Temperature/Humidity Transducers Door Sensors SSRs/Power Controllers Door Side Sensors Counters Area Sensors Timers Proximity Sensors Panel Meters Pressure Sensors Tachometers/Pulse (Rate) Meters Rotary Encoders Display Units Connector/Sockets Sensor Controllers Switching Mode Power Supplies Control Switches/Lamps/Buzzers I/O Terminal Blocks & Cables Stepper Motors/Drivers/Motion Controllers Graphic/Logic Panels Field Network Devices Laser Marking System (Fiber, Co₂, Nd:yag) Laser Welding/Cutting System Thank you for choosing our Autonics product. Please read the following safety considerations before use. Safety Considerations ※Please observe all safety considerations for safe and proper product operation to avoid hazards. ※Safety considerations are categorized as follows. Warning Failure to follow these instructions may result in serious injury or death. Caution Failure to follow these instructions may result in personal injury or product damage. ※The symbols used on the product and instruction manual represent the following symbol represents caution due to special circumstances in which hazards may occur. ※Failure to follow these instructions may result in product damage. Operation indicator (red) 3.8 7.3 14.05 Operation indicator (red) 19 6.6 25 Optical axis M3 Bolt 13.5 5 13.2 11 19 5.4 5.5 22.2 13.9 Ø3, 1m Optical axis 6.4 12.6 7.2 15.4 6.2 Operation indicator (red) 26.5 19 13.5 5 9.7 16.3 13.1 M3 Bolt Ø3, 1m Optical axis Ø3, 1m 5 13.5 6.2 5.4 13.2 22.2 Optical axis 6.4 12.6 6.2 5 13.5 Operation indicator (red) 7 7 5.4 13 16.5 20 M3 Bolt Ø3, 1m Operation indicator (red) M3 Bolt 6 7 9.5 13 Optical axis Ø3, 1m 5 13.5 6.2 5.4 13.2 22.2 6 0.9 2 2 13.1 6.3 M3 Bolt 6 0.9 19 6 0.9 2 2.8 0.9 2 6 0.9 2 14.4 Optical axis 13.5 5 19 2.54 22.2 9.1 11 13.9 5.5 5.4 M3 Bolt 7.5 5.2 13 14 4.5 5.4 2.54 7.62 1.6 3.81 3.81 2.54 Operation indicator (red) 6 9.5 13 7 M3 Bolt 2.54 5 13.5 22.2 5.4 Optical axis 9 6.4 7.2 9 3.6 15.4 13.5 5 19 M3 Bolt Operation indicator (red) M3 Bolt 6.6 13.3 5.4 2.54 13.5 19 26.6 6 0.9 2 2 0.9 6 12.6 Operation indicator (red) M3 Bolt 6.6 19 25 Optical axis 19 25 0.9 6 2 6.3 13.1 M3 Bolt 3.2 Operation indicator (red) 7.3 3.8 14.05 6 Optical axis 6.4 12.6 15.4 13.5 5 Operation indicator (red) 7 13 16.5 20 2.54 7 M3 Bolt 6 0.9 2.8 2 27.6 22.2 5.4 19.4 13.2 13.5 2.54 5 2.8 2 6 0.9 5 Optical axis 2.54 7.62 12 5.3 0.65 12.7 Ø4, 1m (unit: mm) http://www.autonics.com Satisfiable Partner For Factory Automation HEADQUARTERS: 18, Bansong-ro 513beon-gil, Haeundae-gu, Busan, South Korea, 48002 OVERSEAS SALES: #402-404, Bucheon Techno Park, 655, Pyeongcheon-ro, Wonmi-gu, Bucheon, Gyeonggi-do, South Korea, 14502 TEL: 82-32-610-2730 / FAX: 82-32-329-0728 E-mail: [email protected] EP-KE-08-0320G