ON/OFF / //// DC/AC500V ( AUTO ) AUTO / M 10M 11M 10M 0.7%rdg+3dgt) %rdg+3dgt) 10 120 0.4V 1.5V 2 %rdg+10dgt) %rdg+5dgt) 2.0%rdg+5dgt) 5.0%rdg+5dgt) 10%rdg+5dgt) DCV +,- AC500V DC500V,AC500V Peak Max.700V DC[mV] 100.0[mV] 400mV 0.7%rdg dgt) 100.0mV 0.7% )= .0[mV] 100[mV] 100.0mV 0.7%rdg dgt) 99.0[mV] 101.0[mV] 400.0[mV] [dgt] 0.3[mV] DC/AC 500V V PS8a 101-0021 This warranty is valid only within Japan. OL DIGITAL MULTIMETER PS8a -2- -1- -3- -5- -4- -6- -7- -8- -9- -10- -11- -12- -14- -13- SANWA ELECTRIC INSTRUMENT CO., LTD. Dempa Bldg, 4-4 Sotokanda 2-Chome Chiyoda-ku, Tokyo, Japan + - DC/AC 450V T 10cm *:
2
Embed
DIGITAL MULTIMETER - sanwa-meter.co.jp · SANWA ELECTRIC INSTRUMENT CO., LTD. Dempa Bldg, Sotokanda 2-Chome Chiyoda-ku, Tokyo, Japan DIGITAL MULTIMETER PS8a-1--2- -3--4- -5- -6- -7--8-
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
If a finger touches a test pin during measurement, the
reading will be influenced by the resistance in the human
body.
5-4 Checking Continuity ( )
Open voltage is approx. DC 0.4V.
Buzzer sounds at less than 10 ohm to 120 ohm.
5-5 Testing Diode ( )
Diodes is good when following readings appear.
Open voltage is approx. DC 1.5V.
OL indication appears.OL indication appears.
Reading is Forwarding voltage drop
[6] MAINTENANCE
6-1 Maintenance and inspection
6-2 Calibration
6-3 Storage
1.Appearance: Is the appearance not damaged by falling?2.Test leads: Is the cord of the test leads not damaged? Or isthe core wire not exposed at any place of the test leads?If your meter falls in any of the above items, do not use itand have it repaired or replace it with a new one.
The manufacturer may conduct the calibration andinspection. For more information, please contact the dealers.
1.The meter are not resistant to volatile solvent andmust not be cleaned with thinner or alcohol. Forcleaning, use dry, soft cloth and wipe it lightly.
2.The meter are not resistant to heat. Do not place theinstrument near heat-generating devices (such as asoldering iron).
3.Do not store the instrument, in a place where it maybe subjected to vibration or from where it may fall.
4.For storing the instrument, avoid hot, cold or humidplaces or places under direct sunlight or wherecondensation is anticipated.
CAUTION
[7] AFTER-SALES SERVICE
7-1 Repair
Is the test lead broken?
Is the battery exhausted? Please recharge the battery.
7-2 For information or Enquiries
7-3 SANWA web site
If the meter fails during use, check the following items before
sending it for repair.
We repair defective product(s) at cost. When sending it to us
for repair, please use appropriate packing material.
If you need information regarding purchase of repair parts or if
you have any other sales related questions, please contact the