ACCURATE OR COMPLETE. DRAWING TITLE: PROJECT No: SCALE SHEET No. REV. QUALITY RECORD : APPROVED NBNCO APPROVAL RECORD: DD AB WD REV DATE DESCRIPTION SIGNATURE DATE IT SHOULD NOT BE SCALED TO LOCATE NBNCO ASSETS. USE OF NBNCO LIMITED (ABN 86 136 533 741) THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR THE NBNCO DISCLAIMER NO WARRANTY IS GIVEN THAT THE INFORMATION IS FOR USE IN MAINTAINING NBNCO FACILITIES. IT HAS NOT BEEN CREATED FOR ANY OTHER USE. CADREF No: N KEY PLAN OF FSA: STATE: REGION: FSAM: DRAFTER FDA: MAP1 MAP3 MAP4 MAP2 SHEET1 CONTRACTOR LOGO 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 A B C D E F G H A B C D E F G H NBN Co. PIT & PIPE INFRASTRUCTURE TO PROPOSED SUBDIVISION 7001 BERRIGAN STREET STAGES 2 & 3 REDBANK PLAINS QLD AYCA-3QAOUI E16-D15914N N/A 1 3 B APPLY TO OTHER TYPE OF METERING POINT ( any service) BANDSTAND / ROTUNDA / SPORTS FIELD STANDS / OTHER PARK BUILDING Fibre Distribution Hub-FDH Cabinet with Cabinet ID shown Splice Joint on a Transit Cable (TJL) Splice Joint on a Local Cable (LJL) Network Access Point (NAP) Multiport (MPT) n is the number of ports (eg 4,6,8,12) Traffic Lights / Traffic Light Controller / Variable Speed Sign / Traffic Signal Public Transport (bus stop, tram stop, railway station, taxi rank, ferry wharf) Transformer / Kiosk / Pad Mount Sub-station / Pole Mount Transformer Links / Link Pole / MV / HV Links / ABC Links / Dynamic Switch / Airbrake Switch / Isolator Water Infrastructure (storage, pumps, valves water supply, waste water, sewerage stations) Natural Gas Infrastructure Camera (security / traffic) Bridge control, swing bridge, traffic control gates, railway boom gates) Mobile Phone Tower / radio antenna Street Lighting Pole / street light controller Unmanned (council) car park POINT OF SALE DEVICE (vending machine, ticket machine) Zone Terminal / Splice Joint (AJL) Symbol to be used when replacing/removing existing network Splice Joint on a Distribution Cable (DJL) ATM ATM Multiport (MPT) FAN DEPTH ALIGN FSA Boundary FSAM Boundary FDA Boundary CABLE CONFIGURATION CABLE TYPE: CABLES DIVIDE INTO FOLLOWING CATEGORIES AND ARE COLOUR CODED: TRANSIT CABLES DISTRIBUTION CABLES LOCAL CABLES TETHER CABLES LEAD IN (DROP) CABLES CABLE SIZE: CABLE SIZE IS THE TOTAL NUMBER OF OPTIC FIBRES IN THE CABLE AND IS DETERMINED BY A NUMBER FOLLOWED BY F (FIBRE) OR R (RIBBON) IN THE MIDDLE OF THE LINE TYPE CABLE LOCATION: CABLE LOCATIONS DETERMINES WHERE THE CABLE IS USED AS PER BELOW: IN-CONDUIT AERIAL BURIED EXAMPLE: 144 FIBRE AERIAL LOCAL CABLE 1 FIBRE BURIED DROP CABLE 432 FIBRE IN-CONDUIT TRANSIT CABLE LINE TYPES ARE CATEGORIZED INTO 3 TYPES: 1- IN-CONDUIT: (XXXF) 312F , ... 2- AERIAL: (XXXF_A) 144_A , ... 3- BURIED: (XXXF_B) 12_B , ... COLOUR NO: 1 COLOUR NO: 190 COLOUR NO: 4 COLOUR NO: 3 COLOUR NO: 5 312F 288F 144F 12F 1F 288F 144F 96F 144F 1F 1F 48F 576F LASER BEAM DANGER CONDUITS AND DUCTS ARE IN LAYER : < L460 NBN Support - Underground > AND TERMINOLOGY CATEGORIZED INTO TWO GROUPS IN THE DRAWING AS PER BELOW: 1- DUCT USED WITH LOCAL NETWORK 2-CONDUIT USED WITH LEAD-IN DROPS ATTRIBUTES ATTACHED ARE AS SHOWN CONDUIT SIZE CONDUIT LENGTH CONDUIT CONFIGURATION Multi Dwelling Unit (MDU) Fan Access Node site (FAN) Pole (showing pole identity) Premise Connection Device (PCD) Example of descriptor box that will show the type of work and the quantity involved Existing Telstra manhole Existing Telstra Pit ( 2,3,4,5,6,7,8,9 ) Example of Telstra Major Conduit Layout with Proposed duct marked to be used by NBN Telstra exchange NBN MARKER POST MARKER POST TO BE NUMBERED R C X X 138A DEPTH OVER ALIGNMENT SYMBOL TO BE USED WITH EVERY MARKER POST Splice Joint on a Tether Cable (MJL) ASSISTANCE TELEPHONES (EG ELEVATOR AND ROADSIDE PHONES) PRIVATELY OPERATED PAYPHONES POP FDH-ID APS MJL-ID 26.5 P100 - - < _> MPT-ID N NAP-ID DES QTY 5 AAAA POLE-ID PIT-ID 9 PIT-ID 5 PIT-ID 2 AJL-ID LJL-ID DJL-ID TJL-ID CAR LIT MOB CTL CAM GAS WAT SWT PBT TRF PSD PRK ATM MET N Service Drop Access Pit Network Boundary/Local Network Pit (Single Lid) Fibre Distribution Hub (FDH) Pit Distribution/Local Network Connection Pit PIT-ID 8 CABLE TRAY: (650mmX280mmX565mm) (700mmX450mmX650mm) (1360mmX555mmX860mm) (2000mmX555mmX900mm) PIT-ID 9 PIT-ID 5 - 05-10-16 B.HEMPHILL ORIGINAL ISSUE Steve Harte COLANE ST APARA ST BERRIGAN ST KEIDGES RD PURSER RD DIAMOND WY SAPPHIRE CR BERRIGAN ST SAPPHIRE CR SAPPHIRE CR DIAMOND WY DIAMOND WY A 20-01-17 S.H./B.H. ISSUED FOR CONSTRUCTION B 18-04-17 P.H./I.T.J. AS CONSTRUCTED
3
Embed
DIAMOND WY DIAMOND WY DIAMOND WY AYCA-3QAOUI … · wd revdate description signature date it should not be scaled to locate nbnco assets. ... (mdu) fan access node site (fan) pole
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
ACCURATE OR COMPLETE.
DRAWING TITLE:
PROJECT No:
SCALE SHEET No. REV.
QUALITY RECORD :
APPROVED
NBNCO APPROVAL RECORD:
DD
AB
WD
REV DATE DESCRIPTION
SIGNATURE DATE
IT SHOULD NOT BE SCALED TO LOCATE NBNCO ASSETS.
USE OF NBNCO LIMITED (ABN 86 136 533 741)THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR THE
NBNCO DISCLAIMER
NO WARRANTY IS GIVEN THAT THE INFORMATION IS
FOR USE IN MAINTAINING NBNCO FACILITIES.IT HAS NOT BEEN CREATED FOR ANY OTHER USE.
Public Transport (bus stop, tram stop, railway station, taxi rank, ferry wharf)
Transformer / Kiosk / Pad Mount Sub-station / Pole Mount Transformer
Links / Link Pole / MV / HV Links / ABC Links / Dynamic Switch / Airbrake Switch / Isolator
Water Infrastructure (storage, pumps, valves water supply, waste water, sewerage stations)
Natural Gas Infrastructure
Camera (security / traffic)
Bridge control, swing bridge, traffic control gates, railway boom gates)
Mobile Phone Tower / radio antenna
Street Lighting Pole / street light controller
Unmanned (council) car park
POINT OF SALE DEVICE (vending machine, ticket machine)
Zone Terminal / Splice Joint (AJL)
Symbol to be used when replacing/removing existing network
Splice Joint on a Distribution Cable (DJL)
ATMATM
Multiport (MPT)
FAN
DEPTHALIGN
FSA Boundary
FSAM Boundary
FDA Boundary
CABLE CONFIGURATIONCABLE TYPE:
CABLES DIVIDE INTO FOLLOWING CATEGORIES AND ARECOLOUR CODED:TRANSIT CABLESDISTRIBUTION CABLESLOCAL CABLESTETHER CABLESLEAD IN (DROP) CABLES
CABLE SIZE:
CABLE SIZE IS THE TOTAL NUMBER OF OPTICFIBRES IN THE CABLE AND IS DETERMINED BY ANUMBER FOLLOWED BY F (FIBRE) OR R (RIBBON) IN THE MIDDLEOF THE LINE TYPE
CABLE LOCATION:CABLE LOCATIONS DETERMINES WHERE THECABLE IS USED AS PER BELOW:
IN-CONDUITAERIALBURIED
EXAMPLE:
144 FIBRE AERIAL LOCAL CABLE1 FIBRE BURIED DROP CABLE432 FIBRE IN-CONDUIT TRANSIT CABLE
CONDUITS AND DUCTS ARE IN LAYER :< L460 NBN Support - Underground >AND TERMINOLOGY CATEGORIZED INTO TWO GROUPS INTHE DRAWING AS PER BELOW:1- DUCT USED WITH LOCAL NETWORK
2-CONDUIT USED WITH LEAD-IN DROPSATTRIBUTES ATTACHED ARE AS SHOWN
CONDUIT SIZE CONDUIT LENGTH
CONDUIT CONFIGURATION
Multi Dwelling Unit (MDU)
Fan Access Node site (FAN)
Pole (showing pole identity)
Premise Connection Device (PCD)
Example of descriptor box that will show thetype of work and the quantity involved
Existing Telstra manhole
Existing Telstra Pit ( 2,3,4,5,6,7,8,9 )
Example of Telstra Major Conduit Layout withProposed duct marked to be used by NBN
Telstra exchange
NBN MARKER POSTMARKER POST TO BE NUMBERED
RCXX138A
DEPTH OVER ALIGNMENT SYMBOL TO BE USED WITH EVERY MARKER POST
Splice Joint on a Tether Cable (MJL)
ASSISTANCE TELEPHONES (EG ELEVATOR AND ROADSIDE PHONES)
PRIVATELY OPERATED PAYPHONESPOP
FDH-ID
APS
MJL-ID
26.5P100
--
< _>
MPT-IDN
NAP-ID
DESQTY
5
AAAA
POLE-ID
PIT-ID9
PIT-ID5
PIT-ID2
AJL-ID
LJL-ID
DJL-ID
TJL-ID
CAR
LIT
MOB
CTL
CAM
GAS
WAT
SWT
PBT
TRF
PSD
PRK
ATM
MET
N
Service Drop Access Pit
Network Boundary/Local Network Pit (Single Lid)
Fibre Distribution Hub (FDH) Pit
Distribution/Local Network Connection PitPIT-ID8
CABLE TRAY:
(650mmX280mmX565mm)
(700mmX450mmX650mm)
(1360mmX555mmX860mm)
(2000mmX555mmX900mm)
PIT-ID9
PIT-ID5
- 05-10-16 B.HEMPHILL ORIGINAL ISSUE
Steve Harte
COLANE ST
APAR
A ST
BERR
IGAN
ST
KEIDGE
S RD
PURSER RD
DIAMOND WY
SAPPHIRE CR
BERRIG
AN ST
SAPP
HIRE
CR
SAPP
HIRE
CR
DIAMOND WYDIAMO
ND WY
A 20-01-17 S.H./B.H. ISSUED FOR CONSTRUCTION
B 18-04-17 P.H./I.T.J. AS CONSTRUCTED
AutoCAD SHX Text
Limited
AutoCAD SHX Text
**ATTENTION** CONSTRUCTORS DO NOT change or alter job specifications unless first checking with designer.
AutoCAD SHX Text
T
AutoCAD SHX Text
NBN.CO
AutoCAD SHX Text
STAFF WORKING ON THIS ESTIMATE PLEASE NOTE: The location of other authorities services which may affect this work have not been obtained by the estimator. Constructor to obtain service information before commencing.