Thank you for your purchase of a Fowler Dial Caliper. Please carefully review this instruction manual to insure proper and accurate use of your new instrument. Precautions • Maintenance & Cleaning Before use, thoroughly remove oil, dust and dirt from the entire surface of the dial caliper. Be sure not to damage the measuring and reference faces. • Zero Point Confirmation Before taking a measurement, clean and close the jaws and check that the dial needle points to "0" on the dial face. • During Use Properly close the caliper on the workpiece. Do not allow dirt, chips, etc., to enter the rack. Otherwise, the rack and pinion could be seriously damaged, resulting in reduced accuracy and improper zero adjustment. Setting Zero • Clean both measuring faces of jaw (D) and close caliper to see if the needle points to "0" on the dial face. • If caliper does not zero, loosen the bezel clamp screw (B) and rotate the bezel to the "0" position. • Tighten the bezel clamp screw (B) to fix the "0" position. Readings • Inches (1") and tenth inch (.1") measurements can be read on the main scale. • Thousandths (.001") may be read on the dial gage. • One revolution equals .100" Example: Main Scale .800" Dial Indicator .037" Total Value .837" A: Thumbroll B: Bezel Clamp Screw C: Carriage Lock Screw D: Outside Jaws E: Internal Jaws F: Depth Rod G: Step Measurement H: Bezel
1
Embed
Dial Caliper Instructionmedia.hiscoinc.com/Volume2/d110001/medias/docus/201...dial caliper. Be sure not to damage the measuring and reference faces. • Zero Point Confirmation Before
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Th
ank yo
u fo
r you
r pu
rchase o
f a Fo
wler D
ial Calip
er. P
lease carefully review
this in
structio
n m
anu
al to in
sure
pro
per an
d accu
rate use o
f you
r new
instru
men
t.
Pre
ca
utio
ns
• M
ainten
ance &
Clean
ing
Before use, thoroughly rem
ove oil, dust and dirt from the entire surface of the
dial caliper. Be sure not to dam
age the measuring and reference faces.
• Z
ero P
oin
t Co
nfi
rmatio
n B
efore taking a measurem
ent, clean and close the jaws and check that the dial
needle points to "0" on the dial face.
• D
urin
g U
se P
roperly close the caliper on the workpiece. D
o not allow dirt, chips, etc., to
enter the rack. Otherw
ise, the rack and pinion could be seriously damaged,
resulting in reduced accuracy and improper zero adjustm
ent.
Se
tting
Ze
ro •
Clean both m
easuring faces of jaw (D
) and close caliper to see if the needle points to "0" on the dial face. • If caliper does not zero, loosen the bezel clam
p screw (B
) and rotate the bezel to the "0" position. • T
ighten the bezel clamp screw
(B) to fix the "0" position.
Re
ad
ing
s •
Inches (1") and tenth inch (.1") measurem
ents can be read on the main scale.
• Thousandths (.001") m
ay be read on the dial gage. • O
ne revolution equals .100"
Exam
ple:
Main S
cale .800"
Dial Indicator
.037"Total V
alue .837"
A: T
humbroll
B: B
ezel Clam
p Screw
C: C
arriage Lock Screw
D: O
utside Jaws
E: Internal Jaw
sF
: Depth R
odG
: Step M
easurement
H: B
ezel
Th
ank yo
u fo
r you
r pu
rchase o
f a Fo
wler D
ial Calip
er. P
lease carefully review
this in
structio
n m
anu
al to in
sure
pro
per an
d accu
rate use o
f you
r new
instru
men
t.
Pre
ca
utio
ns
• M
ainten
ance &
Clean
ing
Before use, thoroughly rem
ove oil, dust and dirt from the entire surface of the
dial caliper. Be sure not to dam
age the measuring and reference faces.
• Z
ero P
oin
t Co
nfi
rmatio
n B
efore taking a measurem
ent, clean and close the jaws and check that the dial
needle points to "0" on the dial face.
• D
urin
g U
se P
roperly close the caliper on the workpiece. D
o not allow dirt, chips, etc., to
enter the rack. Otherw
ise, the rack and pinion could be seriously damaged,
resulting in reduced accuracy and improper zero adjustm
ent.
Se
tting
Ze
ro •
Clean both m
easuring faces of jaw (D
) and close caliper to see if the needle points to "0" on the dial face. • If caliper does not zero, loosen the bezel clam