Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.
44

Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

Mar 27, 2015

Download

Documents

Bryan Bennett
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

Devices & Networks

SITRAIN

© Siemens AG 2009. All rights reserved.

Page 2: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

Devices & Networks

SITRAIN

© Siemens AG 2009. All rights reserved.

Page 3: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 3 Siemens AG © 2009

Learning targets

The participant should ...

... be able to create and parameterize a required configuration

... be able to read out and parameterize an actual configuration

... become familiar with addressing the input and output modulesof an S7-1200

... be able to adapt an existing hardware configuration to available hardware

Page 4: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 4 Siemens AG © 2009

Assign an IP addressfor the programming device / PC

Network Connections

Control Panel

Local Area Connection

Page 5: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 5 Siemens AG © 2009

Accessible devices in the portal view

Page 6: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 6 Siemens AG © 2009

Accessible devices in the project view

Page 7: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 7 Siemens AG © 2009

Upload actual configuration into programming device (1): Add unspecific CPU

Select unspecific CPU

Page 8: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 8 Siemens AG © 2009

Accessible devices in target subnet:

Device Device type Type Address

PLC_1 CPU1214C DC/DC/DC TCP/IP 192.168.111.1HMI_1 SIMATIC-HMI TCP/IP 192.168.111.2

Load

Upload actual configuration into programming device (2): Detect accessible devices

The device is unspecified

-> Please use the hardware catalog to specify the CPU

-> or detect the configuration for the connected device

Select an accessible device

Detect accessible devices

Add

Page 9: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 9 Siemens AG © 2009

Upload actual configuration into programming device (3): Read out actual configuration

Page 10: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 10 Siemens AG © 2009

Required configuration

Page 11: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 11 Siemens AG © 2009

Open device and network editor

Page 12: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 12 Siemens AG © 2009

Layout of the device and network editor

Page 13: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 13 Siemens AG © 2009

Hardware catalog

Information

Enter the searched term

Filter function

Page 14: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 14 Siemens AG © 2009

Depot for unplugged modules

Open / close depot

Page 15: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 15 Siemens AG © 2009

PLC properties: PROFINET interface

192.168.111.001 192.168.111.050

Select existing subnet

Set up a new subnet

Page 16: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 16 Siemens AG © 2009

PLC properties: Digital inputs

Process interrupt(event)

Assignment of event to interrupt

Pulse catch:Pulses that are shorter than the cycle time can

be detected

Page 17: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 17 Siemens AG © 2009

PLC properties: Digital outputs

Page 18: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 18 Siemens AG © 2009

PLC properties: Analog inputs

Conversion time

Fixed measuring range 0 to 10 V

Enable diagnostic interrupt (OB82)

Page 19: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 19 Siemens AG © 2009

PLC properties: High-speed counters (HSC)

Activate counter

Counting modes:- Counting- Frequency

Operating phase:- Single phase- Two phase- A/B Quadrature 1X- A/B Quadrature 4X

Page 20: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 20 Siemens AG © 2009

PLC properties: Startup mode

Warm restart: Non-retentive memory areas are erased or reset to the start values

Page 21: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 21 Siemens AG © 2009

PLC properties: Time

Time zone

Changeover between standard and daylight

saving time

Page 22: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 22 Siemens AG © 2009

PLC properties: Protection

Page 23: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 23 Siemens AG © 2009

PLC properties: System and clock memory

Page 24: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 24 Siemens AG © 2009

Insert / delete / change modules

You can use drag-and-drop to also insert modules between modules that have already been plugged.

Page 25: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 25 Siemens AG © 2009

Signal board

Signal boards can be used to increase the number of CPU-specific inputs and outputs.

Page 26: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 26 Siemens AG © 2009

Interconnect devices in the network view

Select interface

Page 27: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 27 Siemens AG © 2009

Connect and disconnect

Lock symbol

Connection symbol

Select interface

Page 28: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 28 Siemens AG © 2009

Compile hardware configuration

Select PLC

Warnings and errors in info area

Page 29: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 29 Siemens AG © 2009

Download hardware configuration into device (1)

Short-cut menu

of the station

Accessible nodes

Page 30: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 30 Siemens AG © 2009

Download hardware configuration into device (2)

Before the download

After the download

Page 31: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 31 Siemens AG © 2009

Exercise 1-1: Delete old projects

Right mouse button

Page 32: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 32 Siemens AG © 2009

Exercise 1-2: Assign an IP address for the programming device

Network Connections

Control Panel

Local Area Connection

Page 33: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 33 Siemens AG © 2009

Exercise 1-3: Delete entries for non-existent projects

Page 34: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 34 Siemens AG © 2009

Exercise 1-4: Reset CPU to factory settings

Page 35: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 35 Siemens AG © 2009

Exercise 1-5: Assign an IP address to a CPU

Rightmouse button

Page 36: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 36 Siemens AG © 2009

Exercise 1-6: Create new project

Page 37: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 37 Siemens AG © 2009

Exercise 1-7: Add new device

Page 38: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 38 Siemens AG © 2009

Exercise 1-8: Read out actual configuration

Page 39: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 39 Siemens AG © 2009

Exercise 1-9: CPU properties:Addressing the integrated inputs and outputs

Page 40: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 40 Siemens AG © 2009

Exercise 1-10: CPU properties:Parameterize clock memory byte

Page 41: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 41 Siemens AG © 2009

Exercise 1-11: Parameterize analog module: Measurement type, voltage range, smoothing

Page 42: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 42 Siemens AG © 2009

Exercise 1-12: Analog module: Parameterize I/O addresses

Page 43: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 43 Siemens AG © 2009

Exercise 1-13: Mixed DI/DO module: Parameterize I/O addresses

Page 44: Devices & Networks SITRAIN © Siemens AG 2009. All rights reserved.

SITRAINST-MICRO1 / Geräte und Netze Page 44 Siemens AG © 2009

If you want to know more ...