Top Banner
UK Supplement to Operating Manual Device Information Hydraulic Module HMD 1/(R)SE Accessories for Dual Air / Water Heat Pumps 83062600eUK – Translation into English of the original German operating manual
12

Device Information - OMNIE...-X7 1L2 1L3 2 1-Q5 /2.8 1N1-X7 4 3 5 31 6 42-E22 ZW1 1N2 6 1N3 5 PE L1-X7 N PE L N PE 1-X0 2 1 2 3 PE 3 4 E22 Operating materials X7 UK817383c Control

Apr 20, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Device Information - OMNIE...-X7 1L2 1L3 2 1-Q5 /2.8 1N1-X7 4 3 5 31 6 42-E22 ZW1 1N2 6 1N3 5 PE L1-X7 N PE L N PE 1-X0 2 1 2 3 PE 3 4 E22 Operating materials X7 UK817383c Control

UK

Supplement to Operating Manual

Device InformationHydraulic Module HMD 1/(R)SE

Accessories forDual Air / Water Heat Pumps

83062600eUK – Translation into English of the original German operating manual

Page 2: Device Information - OMNIE...-X7 1L2 1L3 2 1-Q5 /2.8 1N1-X7 4 3 5 31 6 42-E22 ZW1 1N2 6 1N3 5 PE L1-X7 N PE L N PE 1-X0 2 1 2 3 PE 3 4 E22 Operating materials X7 UK817383c Control

2 Subject to change without notice | 83062600eUK – Translation into English of the original German operating manual | ait-deutschland GmbH

Please read firstThe “Model Device Information” is an integral part of the product. It supplements the operating manual “HMD 1/E Air/Water Heat Pump, Outdoor Installation”. In ad-dition to this “Model Device Information”, the operating manual “HMD 1/E” must also be available to you.

Since this “Model Device Information” was written for several different models of the unit, always comply with the parameters for the respective model.

The “Model Device Information” is intended only for persons assigned to work on or operate the unit. Treat all constituent parts confidentially. The information con-tained herein is protected by copyright. No part of this information may be reproduced, transmitted, copied, stored in electronic data systems or translated into an-other language, either wholly or in part, without the ex-press written permission of the manufacturer.

Page 3: Device Information - OMNIE...-X7 1L2 1L3 2 1-Q5 /2.8 1N1-X7 4 3 5 31 6 42-E22 ZW1 1N2 6 1N3 5 PE L1-X7 N PE L N PE 1-X0 2 1 2 3 PE 3 4 E22 Operating materials X7 UK817383c Control

3Subject to change without notice | 83062600eUK – Translation into English of the original German operating manual | ait-deutschland GmbH

Contents

INFORMATION FOR OPERATORS AND QUALIFIED SPECIALISTS

PLEASE READ FIRST ..................................................................2

INFORMATIONS FOR QUALIFIED TECHNICIANS

TECHNICAL DATA/SCOPE OF DELIVERYHMD 1/(R)SE ..........................................................................4

PERFORMANCE CURVESFree compression .................................................................6

TERMINAL DIAGRAM ...............................................................7

CIRCUIT DIAGRAMS ................................................................8

Page 4: Device Information - OMNIE...-X7 1L2 1L3 2 1-Q5 /2.8 1N1-X7 4 3 5 31 6 42-E22 ZW1 1N2 6 1N3 5 PE L1-X7 N PE L N PE 1-X0 2 1 2 3 PE 3 4 E22 Operating materials X7 UK817383c Control

4 Subject to change without notice | 83062600eUK – Translation into English of the original German operating manual | ait-deutschland GmbH

Unit designation HMD 1/SE HMD 1/RSEAccessory for heat pump model LWD 50ASX - LWD 70ASX ı LWD 50ARSX - LWD 70ARSX • applicable ı — not applicable • ı — — ı •

Functionally necessary • applicable ı — not applicable • •Installation location Indoors ı Outdoors • applicable ı — not applicable • ı — • ı —

Maximum indoor temperature °C — 35Maximum relative humidity % — 60

Conformity CE • •Heating circuit Heating circuit efficiency pump integrated: • yes — no — —

Heating circuit free compression ∆p (factory setting) ı Maximum free compression ∆pmax ı Volume flow bar ı bar ı l/h 0,46 ı 0,54 ı 1600 0,46 ı 0,54 ı 1600

Volume flow: minimum flow rate ı maximum flow rate l/h 900 ı 2000 900 ı 2000max. permissible operating pressure bar 3 3Integrated expansion vessel ı Volume ı Initial pressure • yes — no ı l ı bar • ı 12 ı 1,5 • ı 12 ı 1,5Buffer tank integrated: • yes — no — —Heat metering and/or flow rate display integrated: • yes — no • •

General unit data Housing dimensions (Height ı Width ı Depth) mm ı mm ı mm 695 ı 550 ı 330 695 ı 550 ı 330Total weight kg 25 25Connections Heating water inlet (forward flow) ... R 1" Innen R 1" Innen

Hot water outflow (forward flow) ... R 1" Innen R 1" InnenElectrics Voltage code ı three-phase circuit breaker heat pump 5 kW**) ... ı A 1~/N/PE/230V/50Hz ı C16 1~/N/PE/230V/50Hz ı C16

Voltage code ı three-phase circuit breaker heat pump 7 kW**) ... ı A 1~/N/PE/230V/50Hz ı C20 1~/N/PE/230V/50Hz ı C20Voltage code ı circuit breaker control voltage **) ... ı A 1~/N/PE/230V/50Hz ı B16 1~/N/PE/230V/50Hz ı B16Voltage code ı circuit breaker electric heating element 1~230V**) ... ı A 1~/N/PE/230V/50Hz ı B32 1~/N/PE/230V/50Hz ı B32Voltage code ı circuit breaker electric heating element 3~230V**) ... ı A 3~/PE/230V/50Hz ı B16A 3~/PE/230V/50Hz ı B16AProtection type IP 20 20Output electric heating element 3 ı 2 ı 1 phase kW ı kW ı kW 6 ı 4 ı 2 6 ı 4 ı 2Heating circuit pump: maximum power consumption ı current consumption kW ı A 0,07 ı 0,31 0,07 ı 0,31

Safety equipment Safety assembly heating circuit ı Safety assembly heat source in scope of delivery: • yes — no • ı — • ı —Heating and heat pump regulator Incl. in scope of delivery: • yes — no • •Overflow valve integrated: • yes — no — —

** comply with local regulations 813312b 813313b

Technical data / scope of delivery

Page 5: Device Information - OMNIE...-X7 1L2 1L3 2 1-Q5 /2.8 1N1-X7 4 3 5 31 6 42-E22 ZW1 1N2 6 1N3 5 PE L1-X7 N PE L N PE 1-X0 2 1 2 3 PE 3 4 E22 Operating materials X7 UK817383c Control

5Subject to change without notice | 83062600eUK – Translation into English of the original German operating manual | ait-deutschland GmbH

Unit designation HMD 1/SE HMD 1/RSEAccessory for heat pump model LWD 50ASX - LWD 70ASX ı LWD 50ARSX - LWD 70ARSX • applicable ı — not applicable • ı — — ı •

Functionally necessary • applicable ı — not applicable • •Installation location Indoors ı Outdoors • applicable ı — not applicable • ı — • ı —

Maximum indoor temperature °C — 35Maximum relative humidity % — 60

Conformity CE • •Heating circuit Heating circuit efficiency pump integrated: • yes — no — —

Heating circuit free compression ∆p (factory setting) ı Maximum free compression ∆pmax ı Volume flow bar ı bar ı l/h 0,46 ı 0,54 ı 1600 0,46 ı 0,54 ı 1600

Volume flow: minimum flow rate ı maximum flow rate l/h 900 ı 2000 900 ı 2000max. permissible operating pressure bar 3 3Integrated expansion vessel ı Volume ı Initial pressure • yes — no ı l ı bar • ı 12 ı 1,5 • ı 12 ı 1,5Buffer tank integrated: • yes — no — —Heat metering and/or flow rate display integrated: • yes — no • •

General unit data Housing dimensions (Height ı Width ı Depth) mm ı mm ı mm 695 ı 550 ı 330 695 ı 550 ı 330Total weight kg 25 25Connections Heating water inlet (forward flow) ... R 1" Innen R 1" Innen

Hot water outflow (forward flow) ... R 1" Innen R 1" InnenElectrics Voltage code ı three-phase circuit breaker heat pump 5 kW**) ... ı A 1~/N/PE/230V/50Hz ı C16 1~/N/PE/230V/50Hz ı C16

Voltage code ı three-phase circuit breaker heat pump 7 kW**) ... ı A 1~/N/PE/230V/50Hz ı C20 1~/N/PE/230V/50Hz ı C20Voltage code ı circuit breaker control voltage **) ... ı A 1~/N/PE/230V/50Hz ı B16 1~/N/PE/230V/50Hz ı B16Voltage code ı circuit breaker electric heating element 1~230V**) ... ı A 1~/N/PE/230V/50Hz ı B32 1~/N/PE/230V/50Hz ı B32Voltage code ı circuit breaker electric heating element 3~230V**) ... ı A 3~/PE/230V/50Hz ı B16A 3~/PE/230V/50Hz ı B16AProtection type IP 20 20Output electric heating element 3 ı 2 ı 1 phase kW ı kW ı kW 6 ı 4 ı 2 6 ı 4 ı 2Heating circuit pump: maximum power consumption ı current consumption kW ı A 0,07 ı 0,31 0,07 ı 0,31

Safety equipment Safety assembly heating circuit ı Safety assembly heat source in scope of delivery: • yes — no • ı — • ı —Heating and heat pump regulator Incl. in scope of delivery: • yes — no • •Overflow valve integrated: • yes — no — —

** comply with local regulations 813312b 813313b

Page 6: Device Information - OMNIE...-X7 1L2 1L3 2 1-Q5 /2.8 1N1-X7 4 3 5 31 6 42-E22 ZW1 1N2 6 1N3 5 PE L1-X7 N PE L N PE 1-X0 2 1 2 3 PE 3 4 E22 Operating materials X7 UK817383c Control

6 Subject to change without notice | 83062600eUK – Translation into English of the original German operating manual | ait-deutschland GmbH

Free compression HMD 1/(R)SE

Bezeichnung:

Datei: 812035 Freie Pressung HMD 1/( RS )E

812035

Seite: 1/1Zeichnungsnummer:

Legende:“ ” Volumenstrom Heizwasser in m3/h∆p freie Pressung (Werkseinstellung)

Freie Pressung HMD 1/( RS )E

812035

∆pmax freie Pressung maximal

Änd./ÄM/Ersteller/Datum

- /PEP 011-2012 / Liska / 07.11.2012

0,0

0,1

0,2

0,3

0,4

0,5

0,6

0,7

0,8

0,0 0,5 1,0 1,5 2,0 2,5 3,0

∆p

(bar

)

∆pmax

∆p

“ ” (m3/h)812027

Legend: “ ” Heating water volume flow in m³/h ∆p Free compression (factory setting) ∆pmax Free compression maximum

Page 7: Device Information - OMNIE...-X7 1L2 1L3 2 1-Q5 /2.8 1N1-X7 4 3 5 31 6 42-E22 ZW1 1N2 6 1N3 5 PE L1-X7 N PE L N PE 1-X0 2 1 2 3 PE 3 4 E22 Operating materials X7 UK817383c Control

7Subject to change without notice | 83062600eUK – Translation into English of the original German operating manual | ait-deutschland GmbH

-F1

0-F

11

-F12

A1

A2

-Q14-F

13

A1

A2

1N2

PE

2

1L2

3

Pum

p for mixing circuit 1

1

TB1

bl

No function

Sensor m

ixing circuit 1

1

BU

P

MZ

1/MIS

br

X7:1L1,1N

1,PE

Control signal of add

itional heat generator 1; internally w

ired

Charge/discharge/cooling m

ixer 1 close

d

Hot w

ater circulating pum

p/switching valve

External sensor

EV

U

MO

T

FP

1

ZW

1

X0-X

4

Motor protection

Heating circuit circulating pum

p

Cut out com

pressor

3

TR

L

Term

inal in hydraulic m

odule; p

ower supply additional heating

RFV

PE

X

Term

inals

TB

1

External return sensor

HU

P

L1

MA

1/MIS

Term

inal strips on controller board (see sticker)

-X4

circulation pump

ZW

2/SS

T

Accessories: R

emote control

TB

W

A4

Term

inal in hydraulic m

odule fo

r compressor output

Energy supplier contact; close

d on release; bridge if no blocking inte

rval

TAX10

A2

ZU

P

Term

inal strip in hydraulic m

odule switch box; N

/PE

distribution for external 230V devices

Auxiliary circulation pum

p

RF

V

X7:L1,N

,PE

Control signal of add

itional heat generator 2

N

ZU

P

External unit

HU

P

Control e

lement

TB1

3

MOT

LIN

Hot w

ater gauge/therm

ostat

L1

X7

A3

PE

ZIP

M

-X

A4

L1

TA

GND

L1

X10

Charge/discharge/cooling m

ixer 1 open

TBW

N

EVU

Hot w

ater or buffer storage tank

BU

P

HUP

N

1~N/PE/230V/50Hz

2

Nam

e

ZIP

1~N/PE/230V/50Hz

3

ZW2/SST

GND

X7

A1

TA GND

Du

al a

ir-wa

ter

Information

on fuses can be found in the technical data

3

ZW1

M

BUP

MZ1

MIS

EV

U

4

L

1

1L3

1N3

PE

ZW

2

2

PE

F13

Function

1L1

FP

1

LINcon

nection con

trol unit --> external unit

TBW

ZIP

X7

1~N/PE/230V/50Hz

3A

5

-X0

Cut out a

uxiliary heating 2

UK

83

1176b

ZW

2

MA1

Cut out a

uxiliary heating 1

Q14

Leg

en

d:

Cut out controller unit

Contactor ele

ctric heating ele

ment hot w

ater or buffer tank

PE

L

F11

F10

Sub-distribution unit intern

al installation

A2

GND

RFV

PE

Controller board; A

ttention: I-max =

6A

/230VA

C

F12

2

GND

X10

A5

-X3

A1

1N1

-X1

0

ZUP

-X7

-X2

A3

VBO

TRL

PEX

GND

ASD

FP1

1~N/PE/230V/50Hz

Term

inal diagram LW

D 230V

831176

Achim

Pfleg

er2

5.05.2

011

M 045/2013

12

34

56

78

910

1112

1314

1516

12

34

56

78

910

1112

1314

1516 1

/1

1

23.0

7.2

013

ÄM

034/2011

10X

607 - 10X

608

;

aA

chim P

fleger

10X603 - 1

0X6

04;

Blatt-N

r.

Zusta

ndÄ

nde

rung

Bea

rb.

Datu

mN

ame

Bl vo

n An

z

Datu

m

HMD 1/(R)SE Terminal diagram

Page 8: Device Information - OMNIE...-X7 1L2 1L3 2 1-Q5 /2.8 1N1-X7 4 3 5 31 6 42-E22 ZW1 1N2 6 1N3 5 PE L1-X7 N PE L N PE 1-X0 2 1 2 3 PE 3 4 E22 Operating materials X7 UK817383c Control

8 Subject to change without notice | 83062600eUK – Translation into English of the original German operating manual | ait-deutschland GmbH

1L1

-X7

1L2

1L3

21

-Q5

/2.8

1N1

-X7

43

53

1

64

2

-E22

ZW

1

1N265

1N3

PE

L1

-X7

NP

E

LN

PE

1-X

02

12

3P

E

34

E22

Operating m

aterials

X7

UK

81

7383c

Control e

lement

1L1,1L2,1L3,1N

1,1N

2,1N3,P

E; P

ower supply A

ux. heating

1~N

/PE

/230V/50H

z

Contactor for auxiliary heating

K11

ZW

1X

7

Q5

Auxiliary heating

Leg

en

d:

1~N

/PE

/230V/50H

z

Function

-K11

Unit co

nnection

1

X7

Cable

PE

2

LIN

12V/LIN

/GN

DX

7

1~N

/PE

/230V/50H

zL1,N

,PE

; Pow

er supply com

pressor;

LIN

1~N

/PE

/230V/50H

z

Pow

er supply, compressor output -->

exte

rnal unitLIN

bus

Hydraulic m

odule HM

D 230V

817383

Achim

Pfleg

er2

5.08.2

011

M 045/2013

12

34

56

78

910

1112

1314

1516

12

34

56

78

910

1112

1314

1516 1

/2

1

24.0

7.2

013

PE

P 011/2012

150

712;

bA

chim P

fleger

150708;

Blatt-N

r.

Zusta

ndÄ

nde

rung

Bea

rb.

Datu

mN

ame

Bl vo

n An

z

Datu

m

Circuit diagram 1/2 HMD 1/(R)SE

Page 9: Device Information - OMNIE...-X7 1L2 1L3 2 1-Q5 /2.8 1N1-X7 4 3 5 31 6 42-E22 ZW1 1N2 6 1N3 5 PE L1-X7 N PE L N PE 1-X0 2 1 2 3 PE 3 4 E22 Operating materials X7 UK817383c Control

9Subject to change without notice | 83062600eUK – Translation into English of the original German operating manual | ait-deutschland GmbH

PE

NL

L-X

0

L

-X1

0

NN

PE

PE

L-X

0L

L

MOT

-X2

EVU

-X2

ASD

-X2

12

-F6

HUP

-X3

M1

LN

PE

-M4

HU

P

M1

brbl

PE

brblbk

-M5

HU

P

ZW1

-X3

ϑ

-ST

B

A1

A2

-Q5

ZW

1

0-10V12

GN

D12

ϑ

TVL

-X5

-R5

TV

L

GND

ϑ

TRL

-X5

-R4

TR

L

GND

0-1

0V8

GN

D8

AO2

-X6

GND

21

/1.34

3/1.4

65

/1.4

X10

X10

AS

D

ZW

1

-K12

Leg

en

d:

1~N

/PE

/230V/50H

z

EV

U

Return sensor

Supply term

inals in switchbox of hydraulic m

odule; N

/PE

distribution for external 230V units

R4

ST

B

Contactor for auxiliary heating

M4

2

K10

Flow

sensor;

Function

Safety tem

perature limiter, ad

ditional heating

F6

TR

L

Energy supplier contact; close

d on release; bridge if no blocking inte

rval

HU

P

br

C

bl1~N

/PE

/230V/50H

z

EV

U

1

HU

PH

eating pump energy efficiency; installed in E

nergy E

fficiency option

M5

K12

Com

fort plate; installed in Energy E

fficiency option

Flow

sensor

Operating m

aterials

Q5

1

Controller supply

R5

-K10

Heating pum

p; not required in the En

ergy Efficiency option

TV

L

23

0V

AC

UK

81

7383c

Controller board; A

ttention: I-max =

6A

/230VA

C

Hydraulic m

odule HM

D 230V

817383

Achim

Pfleg

er2

5.08.2

011

M 045/2013

12

34

56

78

910

1112

1314

1516

12

34

56

78

910

1112

1314

1516 2

/2

2

24.0

7.2

013

PE

P 011/2012

150

712;

bA

chim P

fleger

150708;

Blatt-N

r.

Zusta

ndÄ

nde

rung

Bea

rb.

Datu

mN

ame

Bl vo

n An

z

Datu

m

HMD 1/(R)SE Circuit diagram 2/2

Page 10: Device Information - OMNIE...-X7 1L2 1L3 2 1-Q5 /2.8 1N1-X7 4 3 5 31 6 42-E22 ZW1 1N2 6 1N3 5 PE L1-X7 N PE L N PE 1-X0 2 1 2 3 PE 3 4 E22 Operating materials X7 UK817383c Control

10 Subject to change without notice | 83062600eUK – Translation into English of the original German operating manual | ait-deutschland GmbH

Page 11: Device Information - OMNIE...-X7 1L2 1L3 2 1-Q5 /2.8 1N1-X7 4 3 5 31 6 42-E22 ZW1 1N2 6 1N3 5 PE L1-X7 N PE L N PE 1-X0 2 1 2 3 PE 3 4 E22 Operating materials X7 UK817383c Control

11Subject to change without notice | 83062600eUK – Translation into English of the original German operating manual | ait-deutschland GmbH

Page 12: Device Information - OMNIE...-X7 1L2 1L3 2 1-Q5 /2.8 1N1-X7 4 3 5 31 6 42-E22 ZW1 1N2 6 1N3 5 PE L1-X7 N PE L N PE 1-X0 2 1 2 3 PE 3 4 E22 Operating materials X7 UK817383c Control

ait-deutschland GmbHIndustriestraße 3D-95359 Kasendorf

E [email protected] www.alpha-innotec.de

alpha innotec – an ait-deutschland GmbH brand

UK