DEVELOPING AND CONDUCTING RESCUE PLANS LJB University ™ has been approved as an Authorized Provider by the International Association for Continuing Education and Training (IACET), 1760 Old Meadow Road, Suite 500, McLean, VA 22102. . Moderator: Speaker: KIM MESSER THOMAS E. KRAMER, P.E., C.S.P. [email protected][email protected]
46
Embed
Developing and Maintaining Fall Protection Rescue Plans
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
DEVELOPING AND CONDUCTING RESCUE PLANS
LJB University™ has been approved as an Authorized Provider by the International Association forContinuing Education and Training (IACET), 1760 Old Meadow Road, Suite 500, McLean, VA 22102. .
Moderator: Speaker:KIM MESSER THOMAS E. KRAMER, P.E., C.S.P.
“The employer must provide for prompt rescue of employees in the event of a fall.”
20
ADDITIONAL OSHA REFERENCES
Safety and Health Information Bulletin (2004)> Prolonged suspension … can result in serious physical injury, or potentially,
death.
> Research indicates that suspension … can result in unconsciousness, followed by death, in less than 30 minutes.
Letters of Interpretations> August 14, 2000
• “While an employee may be safely suspended in a body harness for a longer period than from a body belt, the word “prompt” requires that rescue be performed quickly -- in time to prevent serious injury to the worker.”
21
OSHRC vs. East Texas Coating
> Compliance officer sequenced the events subsequent to a confined space incident to determine whether the employer had acted appropriately
ADDITIONAL OSHA REFERENCES
22
ANSI Z359
Prompt rescue (Z359.2 §6.1)
Written rescue procedures (Z359.2 §6.2)
Summoning rescue services
> Professional (Z359.2 §6.3.1)
> In-house (Z359.2 §6.3.2)
ANSI Z359.4
> Components and systems
23
ANSI A10.32
6.2.1 Employees shall be trained in self-rescue or alternate means shall be provided for prompt rescue in the event of a fall.
6.2.2 A project-specific rescue plan shall be developed which will provide for a form of rescue for employees.
6.2.3 All rescuers shall be provided with adequate training, equipment and personal protective equipment where needed.
24
ADDITIONAL INFORMATION
USAF> 1987 research at Wright-Patterson AFB, OH
NIOSH> International fall protection symposium, 2008> Research report> FACE reports
HSE> Contract research report 451/2002> HSL/2003/09
Articles
25
AGENDA
Regulatory requirements
Prompt rescue
Preparing for a prompt rescue
Closing
26
PROMPT RESCUE
Factors to consider in planning for response
> Hanging vertically in a harness can cause loss of consciousness even in the absence of trauma or blood loss
> The body’s tolerance to suspension trauma varies from person to person
> Rescuing a worker quickly post fall is at least as critical as protecting the worker from a fall
From “Does 911 Work for Rescue?” by Robert N. Aguiluz (September 2003)
27
POST-FALL SUSPENSION
Wright-Patterson AFB study
AP Photo by Janet B. CampbellErie Times-News, 5/25/2004
28
HARNESS SUSPENSION – MOTIONLESS
1987 Study - Wright Patterson Air Force Base > Phase 1 - Body belt, chest harness and full body harness
> Phase 2 - Four types of full body harnesses
29
Phase 1, termination time (in minutes)
> Body belt: 0.35 – 4.76
> Chest harness: 0.62 – 13.13
> Full body harness: 5.08 – 30.12
> Mean averages: 1.63, 6.08, 14.38
HARNESS SUSPENSION – MOTIONLESS
30
The primary causes of termination of the tests were:
Body belt: difficulty in breathing and pressure
Chest harness: cardiovascular symptoms and pressure
Full body harness: cardiovascular symptoms and nausea
HARNESS SUSPENSION – MOTIONLESS
31
Phase 2