Top Banner
DESUPERHEATER & PRESSURE REDUCING DESUPERHEATER c
41

Desuperheater catalog of DAEJU CONTROL CO., LTD.

Nov 08, 2014

Download

Documents

Ki Ho Chung

Desuperheater catalog of DAEJU CONTROL CO., LTD.
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Desuperheater catalog of DAEJU CONTROL CO., LTD.

DESUPERHEATER &PRESSURE REDUCING DESUPERHEATER

c

Page 2: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

The Functioni and Classfication of the Desuperheater and Pressure Reducing DesuperheaterThe series of desuperheater and pressure reducing desuperheater can reduce the inlet steam pressure P1 and temperatureT1 into outlet steam pressure P2 and temperature T2.This process will make superheated steam into saturated steam for more efficiency of heat transfer.

Superheated Steam is better for anti- cavitation and efficiency conservation of energy but not good for sChart heat transfer. Desuperheater will be applied for this process to change superheated steam into saturated steam.Lot of industries need desuperheater like the power station, industrial boiler, thermal power plant,According to the inlet steam pressure P1 and temperature T1, the desuperheater and pressure reducing desuperheater can be classified as high pressure and high temperature desuperheater and pressure reducing desuperheater, Intermediated pressure and pressure reducing desuperheater, desuperheater system and pressure reducing system. And based on the difference of structure, the desuperheater and pressure reducing desuperheater can be also classfied as the first genera- tion (old generation), second generation, third generation, forth generaton and fifth generation.

The code shows as bellowWY - / - - / /

Water Temperature Value Tb,Unit (℃ )

Water Pressure Value Pb,Unit (MPa)

Set Outlet Steam Temperature T2,Unit (℃ )

Set Outlet Steam Pressure P2,Unit (MPa)

Inlet Steam Temperature T1,Unit (℃ )

Intlet Steam Pressure P1,Unit (MPa)

Outlet Steam Folw Rate Q,Unit (t/h)

Desuperheater and Pressure Reducing Desuperheater Code, Presented by Chinese Letter

Note: 1. As for the desuperheater system and pressure reducing system, the code for both system are indicated by"W "and "Y" respectively.

2.The Pressure Value shall be keep one digit after the decimal point.

Example: As for the desuperheater and pressure reducing desuperheater ,if its Code is WY80-3.82/450-0.98/260-8.0/104, which means the inlet steam folw rate is 80t/h; Inlet steam pressure is 3.82MPa, temperature is 450℃ ;Outlet steam pressure is 0.98MPa, temperature is 260℃ ; Water pressure is 8.0 MPa, temperature is 104℃ .

Order InstructionBellow inforamtion shall be informed when place an order:1.Outlet Steam Flow (Q);2.Inlet Steam Pressure P1, Temperature T1;3.Outlet Steam Pressure P2, Temperature T2;4.Water Pressure Pb, Temperature Tb;5.Notify the generation of the desuperheater and pressure reducing desuperheater (First generation is old series,

pneumatic actuator);6.Notify the control signal ( Ⅱ Ⅲ , or others).7.If there is the original drawing, please notify the drawing code, such as WY01-011MX.

If the desuperheater and pressure reducing desuperheater with pneumatic actuator control valve is needed, please also notify the bellow information:1)Air-closing or air-opening;2)Air pressure;3)The positioner signal type, Ⅱ or Ⅲ ;4)Other accessories.

Page 3: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Basic Informations for Order

Outlet Steam Flow Q (t/h)

Inlet Steam Pressure P1 (MPa)

Inlet Steam Temperature T1 (℃ )

Set Outlet Steam Pressure P2 (MPa)

Set Outlet Steam Temperature T2 (℃ )

Water Pressure Pb (MPa)

Water Temperature Tb (℃ )

Noisy Level (dBA)

Inlet Size

Control way

Documents

Necessary Service for Installation

StructureThe third generation desuperheater and pressure reducing desuperheater consist of pressure-reduce system (pressure and temperature reducing valve, throttle panel ), temperature-reducing system (high differential pressure feed-water control valve, throttle valve) and safety system(safety valve, check valve) and so on.

The main features are as bellow:

1.Apply with the pressure and temperature reducing valve

2.There is throttle mesh enclosure in the pressure and temperature reducing valve, which will help to strengthen the nebulization of the water, protect the valve body and seat, prolong the working life, and at the same time reduce the noise.

3.The temperature-reducing system apply with the high differential pressure feed-water control valve, this can not only reduce the leakage of the valve,but also get rid of the back-water branch in the traditional valve structure, help to be lay out easily.

4. For the high differential pressure feed-water control valve with the same diameter, different flow rate CV can be selected, which improves greatly the accuracy and sensitivity of the control.

5. Pressure and temperature reducing valve and high differential pressure feed-water control valve both apply with the linear actuator, and get rid of the traditional lever system, which improve the accuracy and sensitivity in advance.

6. Both Pressure and temperature reducing valve and high differential pressure water- supply control valve will be applied with the linear pneumatic diaphragm actuator, which meet customer’s special requirements.

Page 4: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Performance Information

1. Inlet steam pressure and temperature:P1≤3.82MPa, T1≤450℃。:The Variation Range for oultlet folw Q shall be 30%Q~100%Q, and this range is best.

3. Outlet steam pressure P2:The control accuracy for outlet steam pressure P2 shall not less than 2.5 level.

4. Outlet steam Temperature T2:The control accuracy for outlet steam temperature T2 shall not less than 2.5 level.

5. Noise: when the equipment is in normal working condition, test the noise on the place 1m far from the pressure and temperature reducing valve, and the noise shall not higher than 80 dbA.

The Document for Designing and Manufacturing

1. WY-01 series Linear Electric Actuator Type (Pic 1)

WY-01 linear electric actuator type desuperheater and pressure reducing desuperheater is made up of pressure and temperature reducing valve,

high differential pressure feed-water control valve and main safety valve, impulse safety valve and so on. There are totally 91 types, the

The structure of this series is list in (Table2 ).

2. WY-02 series Linear Electric Actuator Type (Pic 2)

WY-02 linear electric actuator type desuperheater and pressure reducing desuperheater has one more main safety valve , impulse safety valve

The structure of this series is list in (Table 3 ).

3. WY-05, WY-06 series Linear Electric Actuator Type (Pic 3)

WY-05,WY-06 linear electric actuator type desuperheater and pressure reducing desuperheater is made up of pressure andtemperature reducing valve,

high differential pressure feed-water control valve and spring safety valve and so on. As for the WY-05, it applys the A48Y-16C series safety

valve, while the WY-06 applys the A48Y-40 series safety valve.These two series have 27 types respectively, the outlet DN size is 50-150mm, outlet

WY-05 series is list in (Table 4), and the WY-06 series is list in (Table 5).

4. WY-09, WY-10 series and WY-209, WY-210 series Linear Electric Actuator Type (Pic 4, Pic 8)

WY-09,WY-10 and WY-209, WY210 linear electric actuator type desuperheater and pressure reducing desuperheater is made up of pressure and

temperature reducing valve,feed-water control valve and spring safety valve and so on. As for the WY-09, WY-209, both series apply the A48Y-16C

series safety valve, while the WY-10, WY-210 apply the A48Y-40 series safety valve.These two series has 11 types respectively, the outlet DN

≤ 3t/h. The structure of WY-09, WY-209 series are list in (Table 6), and the WY-10, WY210 series are list in

(Table 7).

Page 5: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

The Document for Designing and Manufacturing

5. WY-201 Series Linear Pneumatic Diaphragm Actuator Type (Pic 5)

WY-201 linear pneumatic diaphragm actuator type desuperheater and pressure reducing desuperheater is made up of pressure and temperature

reducing valve, pneumatic diaphragm water-supply control valve and main safety valve, impulse safety valve and so on. There are totally

The structure of this series is list in (Table8 ).

6. WY-202 Series Linear Pneumatic Diaphragm Actuator Type (Pic 6)

WY-202 linear pneumatic diaphragm actuator type desuperheater and pressure reducing desuperheater has one more main safety valve, impulse

is 25t/h-120t/h. The structure of this series is list in (Table 9 ).

7. WY-205, WY-206 Series Linear Pneumatic Diaphragm Actuator Type (Pic 7)

WY-205, WY-206 linear pneumatic diaphragm actuator type desuperheater and pressure reducing desuperheater is made up of pressure and

temperature reducing valve, pneumatic diaphragm actuator feed-water control valve and spring safety valve and so on. As for the WY-205, it

applys with the A48Y-16C series safety valve, while the WY-206 applys with the A48Y-40 series safety valve.These two series has 11

types

WY-205 series is list in (Table 10), and the WY-206

series is list in (Table 11).

8. Desuperheater and Pressure Reducing Desuperheater Type Code Table (Table 1)

Based on normal inlet steam value P1, T1 of the low, middle pressure boiler, this Chart lists the code of corresponding desuperheater and pressure reducing desuperheater value with the scope from P2=1.4-0.1MPa, T2=400-130℃ ,Q=2-120t/h.Note:① This Chart lists the normal value, if there is special value which can not be found in this Chart, please contact our technical department.

② In this Chart,the water value Pb=0.6+1.0MPa, and theT=104℃ .

9. Desuperheater and Pressure Reducing Desuperheater Type Structure Size Table (Table 2-Table11)

As for the desuperheater and pessure reducing desuperheater type structure, pic1-pic8 and Chart2-Char1t1 list the main structure size of

the desuperheater and pessure reducing desuperheater.

10. Find the Correct Desuperheater and Pressure Reducing Desuperheater Code.Desuperheater and Pressure Reducing Desuperheater choosing steps are as bellow:① ②

T1=300℃ , and the outlet pressure P2=0.6MPa, temperature T2=190℃ , then we can get its code WY05-007MX from the Chart1, and once we

know it belongs to WY-05 series, then we can check this drawing in pic3, and check out the structure size in Chart4.

Page 6: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Supply Scope

Desuperheater and Pressure Reducing Desuperheater supply scope is presented by the symbol " ", list as bellow:

1. Pressure-reducing system: pressure and temperaturereducing valve, throttle panel and so on.2. Temperature-reducing system: feed-water control valve, throttle valve and so on.

3. Safety system: safety valve, check valve and so on.

screw bolt and so on.

Page 7: Desuperheater catalog of DAEJU CONTROL CO., LTD.

No Name

1 Pressure & Temperature

2 Steam Pipeline

3 Main Safety Valve

4 Impulse Safety Valve

5 Pressure Gauge

6 Bimetal Themometer

7 Check Valve

8 Feed Water Control Valve9 Throttle Valve

10 Globe Valve

No Name

1 Pressure & Temperature

2 Steam Pipeline

3 Main Safety Valve

4 Impulse Safety Valve

5 Pressure Gauge

6 Bimetal Themometer

7 Check Valve

8 Feed Water Control Valve9 Throttle Valve

10 Globe Valve

No. Item Name

1 PressureReducing Valve

2 Steam Pipeline

3 Spring Safety Valve

4 Pressure Gauge

5 Bimetal Themometer

6 Check Valve

7 Feed Water Control Valve

8 Throttle Valve

9 Globe Valve

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

WY-01 type straight travel desuperheater and pressure reducing desuperheater with electric actuator(one impulse safety valve)

Picture 1

WY-02 type straight travel desuperheater and pressure reducing desuperheater with electric actuator(two impulse safety valves)

Picture 2

WY-05/06 type straight travel desuperheater and pressure reducing desuperheater with electric actuator(one spring safety valve PN16, PN40)

Picture 3

Page 8: Desuperheater catalog of DAEJU CONTROL CO., LTD.

No. Item Name

1 PressureReducing Valve

2 Steam Pipeline

3 Check Valve

4 Spring Safety Valve

5 Pressure Gauge

6 Bimetal Themometer

7 Feed Water Control Valve

8 Throttle Valve

9 Globe Valve

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

WY-09/10 type small flow desuperheater and pressure reducing desuperheater (One spring safety valve PN16, PN40)

Page 9: Desuperheater catalog of DAEJU CONTROL CO., LTD.

No Name

1 Pressure & Temperature

2 Steam Pipeline

3 Main Safety Valve

4 Impulse Safety Valve

5 Pressure Gauge

6 Bimetal Themometer

7 Check Valve

8 Feed Water Control Valve9 Throttle Valve

10 Globe Valve

No Name

1 Pressure & Temperature

2 Steam Pipeline

3 Main Safety Valve

4 Impulse Safety Valve

5 Pressure Gauge

6 Bimetal Themometer

7 Check Valve

8 Feed Water Control Valve9 Throttle Valve

10 Globe Valve

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

WY-201 type desuperheater and pressure reducing desuperheater with pneumatic diaphragm actuator(one impulse safety valve)

Picture 5

WY-202 type desuperheater and pressure reducing desuperheater with pneumatic diaphragm actuator(two impulse safety valves)

Picture 6

WY-202/206 type desuperheater and pressure reducing desuperheater with pneumatic diaphragm actuator(one spring safety valve PN16, PN40)

No.

1

2

3

4

5

6

7

8

9

Picture 7

Page 10: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

WY-209/210 type small flow desuperheater and pressure reducing desuperheater with pneumatic diaphragm actuator(One spring safety valve PN16, PN40)

No. Item Name

1 PressureReducing Valve

2 Steam Pipeline

3 Check Valve

4 Spring Safety Valve

5 Pressure Gauge

6 Bimetal Themometer

7 Feed Water Control Valve

8 Throttle Valve

9 Globe Valve

Page 11: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Desuperheater Type Selectoin Chart

Chart 1

Flow(t/h)

Outlet Steam

P2 T2

0.05 130

Inlet Steam P1(MPa) and T1(℃ )P1 T1 P1 T1 P1 T1 P1 T1 P1 T1 P1 T11.3 300 1.3 350 2.5 375 2.5 400 3.5 435 3.9 450

0.1 140 WY09-011MX WY09-011MX

0.2 150WY05-005MX WY05-005MX WY05-005MX WY05-005MX

WY09-007MX WY09-007MX

0.3 160 WY09-006MX WY09-006MX

2 0.4 170

0.6 190

0.8 220

1.0 250

1.3 300

WY05-001MX WY05-001MXWY05-001MX WY05-001MX

WY09-006MX WY09-006MX

WY05-001MX WY05-001MX

0.05 130 WY01-014MX WY01-014MX

0.1 140WY01-002MX WY01-002MX

0.2 150 WY01-002MX WY01-002MX

0.3 160

5 0.4 170WY05-017MX WY05-017MX WY05-017MX WY05-017MX

0.6 190 WY05-007MX WY05-007MX WY05-007MX WY05-007MX WY05-006MX WY05-006MX

0.8 220

1.0 250

1.3 300

0.05 130

WY05-004MX WY05-004MXWY05-004MX WY05-004MX WY05-005MX WY05-005MX

0.1 140 WY01-033MX WY01-033MX

0.2 150 WY01-015MX WY01-015MX WY01-015MX WY01-015MX

0.3 160

0.4 170

0.5 18010

0.6 190

0.7 220

WY01-003MX WY01-003MX WY01-003MX WY01-003MXWY01-002MX WY01-002MX

0.8 220WY05-018MX WY05-018MX WY05-018MX WY05-018MX WY05-017MX WY05-017MX

1.0 250 WY05-018MX WY05-018MX WY05-017MX WY05-017MX

1.3 300

1.4 350

0.05 130

0.1 140

0.2 150 WY01-034MX WY01-034MX WY01-033MX WY01-033MX

0.3 160 WY01-016MX WY01-016MX WY01-015MX WY01-015MX

WY05-007MX WY05-007MX

15 0.4 170 WY01-011MX WY01-011MX WY01-012MX WY01-012MX WY01-012MX WY01-012MX

0.7 190

1.0 250

1.3 300

1.4 350

WY01-004MX WY01-004MX WY01-003MX WY01-003MX WY01-003MX WY01-003MX

WY05-018MX WY05-018MX WY05-018MX WY05-018MX

Page 12: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Desuperheater Type Selectoin Chart Chart 1

Flow(t/h)

Outlet Steam

P2 T2

0.05 130

0.1 140

Inlet Steam P1(MPa) and T1(℃ )P1 T1 P1 T1 P1 T1 P1 T1 P1 T1 P1 T11.3 300 1.3 350 2.5 375 2.5 400 3.5 435 3.9 450

0.2 150 WY01-050MX WY01-050MX WY01-049MX WY01-054MX

0.3 160 WY01-034MX WY01-034MXWY01-034MX WY01-024MX

0.4 170 WY01-035MX WY01-035MX WY01-023MX WY01-023MX

0.5 180WY01-017MX WY01-017MX

WY01-016MX WY01-016MX WY01-023MX WY01-023MX

20 0.6 190 WY01-011MX WY01-011MX WY01-009MX WY01-009MX

0.7 200 WY01-017MX WY01-017MX WY01-011MX WY01-011MX WY01-009MX WY01-009MX

0.8 220

1.0 250

1.1 300

1.2 250

1.3 300

1.4 350

WY01-004MX

WY01-004MX WY01-004MX WY01-003MX WY01-003MX

0.05 130 WY02-027MX

0.1 140 WY02-017MX

0.2 150 WY01-059MX WY01-064MX WY01-065MX WY01-065MX

0.3 160 WY01-050MX WY01-053MX WY01-054MX WY01-054MX

0.4 17025 WY01-035MX WY01-025MX WY01-024MX WY01-024MX WY01-023MX WY01-023MX

0.5 180

0.7 200WY01-017MX WY01-017MX

WY01-016MX WY01-019MX WY01-023MX WY01-023MX

1.0 250 WY01-011MX WY01-011MX WY01-009MX WY01-009MX

1.2 250 WY01-004MX WY01-004MX WY01-009MX WY01-009MX

1.3 300 WY01-004MX WY01-004MX WY01-004MX WY01-003MX

0.05 130 WY02-027MX WY02-027MX

0.1 140 WY02-017MX WY02-017MX

0.2 150 WY01-064MX WY01-064MX WY01-065MX WY01-065MX

0.3 160 WY01-059MX WY01-064MX WY01-065MX WY01-065MX

0.4 170 WY01-050MX WY01-053MX WY01-054MX WY01-054MX WY01-054MX WY01-054MX30

0.5 180

0.6 190

0.7 200

1.0 250

WY01-035MX WY01-025MX WY01-024MX WY01-024MX WY01-024MX WY01-024MX

WY01-019MX WY01-011MX WY01-011MX WY01-011MX

1.3 300 WY01-011MX

Page 13: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Desuperheater Type Selectoin Chart

Chart 1

Flow(t/h)

Outlet Steam

P2 T2

0.05 130

0.1 140

0.2 150

0.3 160

Inlet Steam P1(MPa) and T1(℃ )P1 T1 P1 T1 P1 T1 P1 T1 P1 T1 P1 T11.3 300 1.3 350 2.5 375 2.5 400 3.5 435 3.9 450

WY02-026MX WY02-026MX

WY01-065MX WY01-065MX WY01-063MX WY01-063MX

35 0.4 170 WY01-054MX WY01-054MX WY01-054MX WY01-065MX

0.5 180 WY01-063MX WY01-063MX WY01-054MX WY01-054MX WY01-054MX WY01-065MX

0.7 200 WY02-026MX WY01-024MX WY01-024MX WY01-024MX WY01-024MX

1.0 250 WY01-017MX

1.3 300 WY01-017MX

0.05 130

0.1 140 WY02-026MX WY02-026MX

0.2 150 WY02-016MX WY02-016MX WY02-017MX WY02-017MX

0.3 160

WY01-019MX WY01-019MX

0.4 170

0.5 180

WY01-063MX WY01-063MX WY01-064MX WY01-064MXWY01-065MX WY01-065MX

0.6 190 WY01-053MX WY01-053MX40

0.7 200

0.8 220 WY02-026MX

1.0 250

WY01-025MX WY01-025MXWY01-024MX WY01-024MX

1.1 300 WY01-035MX WY01-035MX WY01-024MX WY01-024MX

1.2 250 WY01-019MX WY01-019MX

1.3 300WY01-017MX WY01-017MX

WY01-019MX WY01-019MX

1.4 350 WY01-016MX WY01-016MX

0.05 130

0.1 140

0.2 150 WY02-025MX WY02-025MX WY02-026MX WY02-026MX

0.3 160 WY02-017MX WY02-017MX WY02-017MX WY02-017MX

0.4 170 WY02-017MX WY02-017MX WY02-016MX WY02-016MX WY02-017MX WY02-017MX

60 0.5 180

0.6 190

0.7 200WY01-063MX WY01-063MX WY01-064MX WY01-064MX

0.8 220 WY01-062MX WY01-063MX WY01-063MX WY01-063MX WY01-064MX WY01-064MX

1.0 250

1.2 250WY01-053MX WY01-053MX

Page 14: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Desuperheater Type Selectoin Chart

Chart 1

Outlet Steam Inlet Steam P1(MPa) and T1(℃ )Flow(t/h) P2 T2 P1 T1 P1 T1 P1 T1 P1 T1 P1 T1 P1 T1

1.3 300 1.3 350 2.5 375 2.5 400 3.5 435 3.9 450

1.3 300 WY01-040MX WY01-040MX60

1.4 400 WY01-039MX WY01-039MX

0.05 130

0.1 140

0.2 150

0.3 160 WY02-025MX WY02-025MX WY02-026MX WY02-026MX

0.4 170

0.5 180

80 0.6 190

0.7 200

WY02-015MX WY02-015MX WY02-016MX WY02-016MX WY02-017MX WY02-017MX

0.8 220 WY01-062MX WY01-062MX

1.0 250

1.2 250

WY01-063MX WY01-063MXWY01-063MX WY01-063MX

120

1.3 300 WY01-063MX WY01-063MX

1.4 350 WY01-060MX WY01-060MX WY01-063MX WY01-063MX

0.3 160

0.4 170

0.5 180

0.6 190 WY02-024MX WY02-024MX WY02-025MX

0.7 200 WY02-024MX WY02-024MX WY02-025MX

0.8 220 WY02-014MXWY02-014MX

WY02-015MXWY02-015MX

1.0 250 WY02-014MX WY02-015MX WY02-015MX

1.2 250

1.3 300

1.4 350

Page 15: Desuperheater catalog of DAEJU CONTROL CO., LTD.

No

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Dimention Chart for Desuperheater① Type ② Pressure & Temperature Reducing Valve Diameter (DN1) ③ Steam Pipeline Diameter (Dw×S)④ Feed-Water Control Valve Diameter (D4) ⑤ Main Safety Valve Inlet and Outlet Diameter (DN2×DN3)⑥ Structure Size ⑦ Drawing Number ⑧ Total Weight (Kg) Chart 2

① ② (DN1) ③ (Dw×S) ④ (D4) ⑤ (DN2×DN3)⑥

⑦b H h1 h2 l Lmax

WY01-001MX 50

Φ219×9

20

150×200 220

260

528 236

222 3522

WY-01

WY01-002MX 80 305 280 3530

WY01-003MX 100 320 300 3240

WY01-004MX150 410 355 2950

WY01-005MX

32

WY01-006MX 100 320 300 3240

WY01-007MX80 305 280

3530

WY01-008MX

Φ273×11

553 263

3755

WY01-009MX 100 320 300 3735

WY01-010MX150 410 355 3405

WY01-011MX

20

WY01-012MX 100 320 300 3735

WY01-013MX80 305 280 3755

WY01-014MX

200×300 270

634 263

WY01-015MX 100 320 300 3735

WY01-016MX 150 410 355 3405

WY01-017MX200 420 395 3090

WY01-018MX

32

WY01-019MX 150 410 355 3405

WY01-020MX 100 320 300 3735

WY01-021MX80 305 280

3755

WY01-022MX

Φ325×10 684 289

3830

WY01-023MX 100 320 300 3920

WY01-024MX 150 410 355 3940

WY01-025MX 200 420 395 3585

WY01-026MX250 455 445 3210

WY01-027MX

50

WY01-028MX 200 420 395 3585

WY01-029MX 150 410 355 3940

WY01-030MX 100 320 300 3920

WY01-031MX80 305 280 3830

WY01-032MX

20WY01-033MX 100 320 300 3920

WY01-034MX 150 410 355 3940

Page 16: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Dimention Chart for Desuperheater① Type List ② Pressure & Temperature Reducing Valve Diameter (DN1) ③ Steam Pipeline Diameter (Dw×S)④ Feed-Water Control Valve Diameter (D4) ⑤ Main Safety Valve Inlet and Outlet Diameter (DN2×DN3)⑥ Structure Size ⑦ Drawing Number ⑧ Total Weight (Kg)

Chart 2

① ② (DN1) ③ (Dw×S) ④ (D4) ⑤ (DN2×DN3) ⑥ ⑦b H h1 h2 l Lmax

WY01-035MX 200Φ325×10

20

200×300 270

420684 289

395 3585

WY-01

WY01-036MX 250 455 445 3210

WY01-037MX 100

Φ377×10

320

709 315

300 4046

WY01-038MX 150 410 355 4066

WY01-039MX200 420 395 4061

WY01-040MX

32WY01-041MX 150 410 355 4066

WY01-042MX 100 320 300 4046

WY01-043MX80 305 280 3956

WY01-044MX20

WY01-045MX250 455 445 3686

WY01-046MX32

WY01-047MX100

250×350 300

320

778 315

300 4546WY01-048MX

20WY01-049MX 150 410 355 4566

WY01-050MX 200 420 395 4561

WY01-051MX250 455 445 4186

WY01-052MX

32WY01-053MX 200 420 395 4561

WY01-054MX150 410 355 4566

WY01-055MX

50WY01-056MX 200 420 395 4561

WY01-057MX 250 455 445 4186

WY01-058MX 150

Φ426×11

20

410

803 339

355 4606

WY01-059MX 200 420 395 4601

WY01-060MX 250 455 445 4226

WY01-061MX300 574 511 3942

WY01-062MX

32WY01-063MX 250 455 445 4226

WY01-064MX 200 420 395 4601

WY01-065MX150 410 355 4606

WY01-066MX

50WY01-067MX 200 420 395 4601

WY01-068MX 250 455 445 4226

Page 17: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Dimention Chart for Desuperheater① Type List ② Pressure & Temperature Reducing Valve Diameter (DN1) ③ Steam Pipeline Diameter (Dw×S)④ Feed-Water Control Valve Diameter (D4) ⑤ Main Safety Valve Inlet and Outlet Diameter (DN2×DN3)⑥ Structure Size ⑦ Drawing Number ⑧ Total Weight (Kg)

Chart 2

① ② (DN1) ③ (Dw×S) ④ (D4) ⑤ (DN2×DN3)⑥

⑦b H h1 h2 l Lmax

WY01-069MX 300 Φ426×11 50

250×350 300

574 803 339 511 3942

WY-01

WY01-070MX150

Φ530×12

20410

859 391

355 4980WY01-071MX

32

WY01-072MX 200 420 395 5075

WY01-073MX 250 455 445 5050

WY01-074MX 300 574 511 4766

WY01-075MX400 750 645 4320

WY01-076MX

50

WY01-077MX 300 574 511 4766

WY01-078MX 250 455 445 5050

WY01-079MX 200 420 395 5075

WY01-080MX 150 410 355 4980

WY01-081MX 200

Φ630×12

32

420

909 441

395 5225

WY01-082MX 250 455 445 5200

WY01-083MX 300 574 511 4916

WY01-084MX400 750 645 4470

WY01-085MX

50

WY01-086MX 300 574 511 4916

WY01-087MX 250 455 445 5200

WY01-088MX 200 420 395 5225

WY01-089MX

150 410 355 5130WY01-090MX 32

WY01-091MX 20

Page 18: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Dimention Chart for Desuperheater① Type List ② Pressure & Temperature Reducing Valve Diameter (DN1) ③ Steam Pipeline Diameter (Dw×S)④ Feed-Water Control Valve Diameter (D4) ⑤ First Main Safety Valve Inlet and Outlet Diameter (DN2×DN3)

Chart 3

⑥ Second Main Safety Valve Inlet and Outlet Diameter (DN2'×DN3') ⑦ Structure Size ⑧ Drawing Number ⑨ Total Weight (Kg)

① ② ③ ④(D4)

⑤(DN2×DN3)

⑥(DN2'×DN3')

⑦⑧

H b b' h1 h2 h1' h2' l Lmax

WY02-001MX 150

Φ426×11

20

150×200

250×350

410

220

300

670 340 822 340

355 5570

WY-02

WY02-002MX 200 420 395 5565

WY02-003MX 250 455 445 5190

WY02-004MX300 574 491 4906

WY02-005MX

32WY02-006MX 250 455 445 5190

WY02-007MX 200 420 395 5565

WY02-008MX150 410 355

5570

WY02-009MX

Φ530×12

20

250×350 300

877 392 877 392

5790

WY02-010MX 200 420 395 5885

WY02-011MX 250 455 445 5860

WY02-012MX 300 574 491 5576

WY02-013MX400

750570 5140

WY02-014MX

32

750

WY02-015MX 300 574 491 5576

WY02-016MX 250 455 445 5860

WY02-017MX 200 420 395 5885

WY02-018MX150

410355 5790

WY02-019MX

Φ630×12

20

410

909 441 909 441

WY02-020MX 200 420 395 5885

WY02-021MX 250 455 445 5860

WY02-022MX 300 574 491 5576

WY02-023MX400

750570 5140

WY02-024MX

32

750

WY02-025MX 300 574 491 5576

WY02-026MX 250 455 445 5860

WY02-027MX 200 420 395 5885

WY02-028MX150

410 355 5790

WY02-029MX

Φ426×11

50

150×200

410

220 670 340 822 340

355 5570

WY-02A

WY02-030MX 200 420 395 5565

WY02-031MX 250 455 445 5190

WY02-032MX 300 574 491 4906

WY02-033MX 150Φ530×12 250×350

410300 877 392 877 392

355 5790

WY02-034MX 200 420 395 5885

Page 19: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Dimention Chart for Desuperheater① Type List ② Pressure & Temperature Reducing Valve Diameter (DN1) ③ Steam Pipeline Diameter (Dw×S)④ Feed-Water Control Valve Diameter (D4) ⑤ First Main Safety Valve Inlet and Outlet Diameter (DN2×DN3)

Chart 3

⑥ Second Main Safety Valve Inlet and Outlet Diameter (DN2'×DN3') ⑦ Structure Size ⑧ Drawing Number ⑨ Total Weight (Kg)

① ②(DN1)

③(Dw×S)

④(D4)

⑤(DN2×DN3)

⑥(DN2'×DN3')

⑦⑧ ⑨ (Kg)

H b b' h1 h2 h1' h2' l Lmax

WY02-035MX 250

Φ530×12

50

250×350 250×350

455

300 300

877 392 877 392

445 5860

WY-02A

3321

WY02-036MX 300 574 491 5576 3275

WY02-037MX 400 750 570 5140 3576

WY02-038MX 150

Φ630×12

410

909 441 909 441

355 5790 3092

WY02-039MX 200 420 395 5885 3342

WY02-040MX 250 455 445 5860 3456

WY02-041MX 300 574 491 5576 3410

WY02-042MX 400 750 570 5140 37

WY02-043MX 200

Φ720×12

420

965 492 965 492

395 6417 3635

WY02-044MX 250 455 445 6654 3882

WY02-045MX 300 574 491 6820 4054

WY02-046MX 400750 570 6384

4355

WY02-047MX 400

32

4264

WY02-048MX 300 574 491 6820 3963

WY02-049MX 250 455 445 6654 3791

WY02-050MX 200 420 395 6417 3544

WY02-051MX 400 20 750 570 6384 4198

Page 20: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Dimention Chart for Desuperheater① Type List ② Pressure & Temperature Reducing Valve Diameter (DN1) ③ Steam Pipeline Diameter (Dw×S)④ Feed-Water Control Valve Diameter (D3) ⑤ Spring Safety Diameter (DN, PN16)⑥ Structure Size ⑦ Drawing Number ⑧ Total Weight (Kg)

Chart 4

① ② (DN1) ③(Dw×S) ④ (D3) ⑤ DN(PN16)⑥

⑦ ⑧ b DN2 h l Lmax

WY05-001MX50

Φ89×4.5

20

50 135 65

283222

2146

WY-05

347

WY05-002MX

Φ108×4.5

2932422 372

WY05-003MX80 280 2030

390

WY05-004MX

80 170 100

308429

WY05-005MX50 222 2422

408

WY05-006MX

Φ133×6

319418

WY05-007MX80 280 2030

438

WY05-008MX

50 135 65

304403

WY05-009MX50 222

2422 382

WY05-010MX

Φ159×7

316

2672 419

WY05-011MX 80 280 2410 455

WY05-012MX100 300 2120

474

WY05-013MX

80 170 100 331

509

WY05-014MX 80 280 2410 489

WY05-015MX50 222 2672

454

WY05-016MX

100 205 125 356

480

WY05-017MX 80 280 2410 516

WY05-018MX100 300 2120

535

WY05-019MX

32

601

WY05-020MX 80 280 2410 582

WY05-021MX50 222 2672

546

WY05-022MX

80 170 100 331

520

WY05-023MX 80 280 2410 556

WY05-024MX50 300 2120

575

WY05-025MX

50 135 65 316

540

WY05-026MX 80 280 2410 521

WY05-027MX 50 222 2672 485

Page 21: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Dimention Chart for Desuperheater① Type List ② Pressure & Temperature Reducing Valve Diameter (DN1) ③ Steam Pipeline Diameter (Dw×S)④ Feed-Water Control Valve Diameter (D3) ⑤ Spring Safety Diameter (DN, PN40)⑥ Structure Size ⑦ Drawing Number ⑧ Total Weight (Kg) Chart 5

① ② (DN1) ③(Dw×S) ④ (D3) ⑤ DN(PN40)⑥

⑦ ⑧ b DN2 h l Lmax

WY06-001MX50

Φ89×4.5

20

50 135 65

326222

2146

WY-06

339

WY06-002MX

Φ108×4.5

3362422 363

WY06-003MX80 280 2030

384

WY06-004MX

80 170 100

361427

WY06-005MX50 222 2422

406

WY06-006MX

Φ133×6

372416

WY06-007MX80 280 2030

436

WY06-008MX

50 135 65

347395

WY06-009MX50 222

2422 374

WY06-010MX

Φ159×7

359

2672 410

WY06-011MX 80 280 2410 446

WY06-012MX100 300 2120

465

WY06-013MX

80 170 100 384

507

WY06-014MX 80 280 2410 488

WY06-015MX50 222 2672

452

WY06-016MX

100 200 125 419

477

WY06-017MX 80 280 2410 513

WY06-018MX100 300 2120

532

WY06-019MX

32

598

WY06-020MX 80 280 2410 579

WY06-021MX50 222 2672

543

WY06-022MX

80 170 100 384

518

WY06-023MX 80 280 2410 556

WY06-024MX100 300 2120

573

WY06-025MX

50 135 65 359

531

WY06-026MX 80 280 2410 512

WY06-027MX 50 222 2672 476

Page 22: Desuperheater catalog of DAEJU CONTROL CO., LTD.

① ②(DN1)

③(Dw×S)

④阀 (D3)

⑤DN(PN16)

⑥ ⑦ ⑧(Kg)b DN2 h l L1 Lmax

WY09/209-001MX25

Φ57×4

20

32 115 40 220158

2663 3180

WY-09/209

275

WY09/209-002MX Φ89×4.5 50 135 65 283 3000 3738 339.3

WY09/209-003MX

40

Φ57×4 32 115 40 220

200

2663 3243 291

WY09/209-004MX Φ89×4.550 135 65

283

3000

3800 356.3

WY09/209-005MXΦ108×4.5

293

3940

377.3

WY09/209-006MX80 170 100

308 412

WY09/209-007MXΦ133×6

319 439

WY09/209-008MX50 135 65

304 404

WY09/209-009MX

Φ159×7

316

3700 4620

480

WY09/209-010MX 80 170 100 331 514.2

WY09/209-011MX 100 205 125 356 540.4

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Dimention Chart for Desuperheater① Type List ② Pressure Reducing Valve Diameter (DN1) ③ Hybird Steam Pipeline Diameter (Dw×S)④ Feed-Water Control Valve Diameter (D3) ⑤ Spring Safety Diameter (DN, PN16)⑥ Structure Size ⑦ Drawing Number ⑧ Total Weight (Kg)

① Type List ② Pressure Reducing Valve Diameter (DN1) ③ Hybird Steam Pipeline Diameter (Dw×S)④ Feed-Water Control Valve Diameter (D3) ⑤ Spring Safety Diameter (DN, PN40)⑥ Structure Size ⑦ Drawing Number ⑧ Total Weight (Kg)

Chart 6

Chart 7

① ②(DN1) ③ (Dw×S) ④ (D3) ⑤ DN(PN40)⑥

⑦ ⑧ b DN2 h l L1 Lmax

WY10/210-001MX25

Φ57×4

20

32 115 40 260158

2663 3180

WY-10/210

276

WY10/210-002MX Φ89×4.5 50 135 65 326 3000 3738 329

WY10/210-003MX

40

Φ57×4 32 115 40 260

200

2663 3243 292

WY10/210-004MX Φ89×4.550 135 65

326

3000

3800 347

WY10/210-005MXΦ108×4.5

336

3940

368

WY10/210-006MX80 170 100

361 409

WY10/210-007MXΦ133×6

372 436

WY10/210-008MX50 135 65

347 395

WY10/210-009MX

Φ159×7

359

3700 4620

474

WY10/210-010MX 80 170 100 384 5

WY10/210-011MX 100 205 125 419 533

Page 23: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Dimention Chart for Desuperheater① Type List ② Pressure & Temperature Reducing Valve Diameter (DN1) ③ Steam Pipeline Diameter (Dw×S)④ Feed-Water Control Valve Diameter (D4) ⑤ Main Safety Valve Inlet and Outlet Diameter (DN2×DN3)⑥ Structure Size ⑦ Drawing Number ⑧ Total Weight (Kg) Chart 8

① ② (DN1) ③(Dw×S) ④(D4) ⑤ (DN2×DN3)⑥

⑦ ⑧b H h1 h2 l Lmax

WY201-001MX 50

Φ219×9

20

150×200 220

260

528 236

222 3572

WY-201

WY201-002MX 80 305 280 3580

WY201-003MX 100 320 300 3290

WY201-004MX150 410 355 3000

WY201-005MX

32

WY201-006MX 100 320 300 3290

WY201-007MX80 305 280

3580

WY201-008MX

Φ273×11

553 263

3805

WY201-009MX 100 320 300 3785

WY201-010MX150 410 355 3455

WY201-011MX

20

WY201-012MX 100 320 300 3785

WY201-013MX80 305 280 3805

WY201-014MX

200×300 270

634 263

WY201-015MX 100 320 300 3785

WY201-016MX 150 410 355 3455

WY201-017MX200 420 395 3140

WY201-018MX

32

WY201-019MX 150 410 355 3455

WY201-020MX 100 320 300 3785

WY201-021MX80 305 280

3805

WY201-022MX

Φ325×10 684 289

3880

WY201-023MX 100 320 300 3970

WY201-024MX 150 410 355 3990

WY201-025MX 200 420 395 3635

WY201-026MX250 455 445 3260

WY201-027MX

50

WY201-028MX 200 420 395 3635

WY201-029MX 150 410 355 3990

WY201-030MX 100 320 300 3970

WY201-031MX80 305 280 3880

WY201-032MX

20WY201-033MX 100 320 300 3970

WY201-034MX 150 410 355 3990

Page 24: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Dimention Chart for Desuperheater① Type List ② Pressure & Temperature Reducing Valve Diameter (DN1) ③ Steam Pipeline Diameter (Dw×S)④ Feed-Water Control Valve Diameter (D4) ⑤ Main Safety Valve Inlet and Outlet Diameter (DN2×DN3)⑥ Structure Size ⑦ Drawing Number ⑧ Total Weight (Kg)

Chart 8

① ② (DN1) ③(Dw×S) ④(D4) ⑤ (DN2×DN3)⑥

⑦ ⑧b H h1 h2 l Lmax

WY201-035MX 200Φ325×10

20

200×300 270

420684 289

395 3635

WY-201

WY201-036MX 250 455 445 3260

WY201-037MX 100

Φ377×10

320

709 315

300 4096

WY201-038MX 150 410 355 4116

WY201-039MX200 420 395 4111

WY201-040MX

32WY201-041MX 150 410 355 4116

WY201-042MX 100 320 300 4096

WY201-043MX80 305 280 4006

WY201-044MX20

WY201-045MX250 455 445 3736

WY201-046MX32

WY201-047MX100

250×350 300

320

778 315

300 4546WY201-048MX

20WY201-049MX 150 410 355 4566

WY201-050MX 200 420 395 4561

WY201-051MX250 455 445 4186

WY201-052MX

32WY201-053MX 200 420 395 4561

WY201-054MX150 410 355 4566

WY201-055MX

50WY201-056MX 200 420 395 4561

WY201-057MX 250 455 445 4186

WY201-058MX 150

Φ426×11

20

410

803 339

355 4606

WY201-059MX 200 420 395 4601

WY201-060MX250

455445 4226

WY201-061MX

32

455

WY201-062MX 200 420 395 4601

WY201-063MX150

410355 4606

WY201-064MX

50

410

WY201-065MX 200 420 395 4601

WY201-066MX250

455445

4226

WY201-067MXΦ530×12 20

455859 391

5050

WY201-068MX 200 420 395 5075

Page 25: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Dimention Chart for Desuperheater① Type List ② Pressure & Temperature Reducing Valve Diameter (DN1) ③ Steam Pipeline Diameter (Dw×S)④ Feed-Water Control Valve Diameter (D4) ⑤ Main Safety Valve Inlet and Outlet Diameter (DN2×DN3)⑥ Structure Size ⑦ Drawing Number ⑧ Total Weight (Kg)

Chart 8

① ② (DN1) ③(Dw×S) ④ (D4) ⑤ (DN2×DN3) b H ⑥h1 h2 l Lmax ⑦ ⑧ (Kg)

WY201-069MX150

WY201-070MX 20

410 355 498021502158

WY201-071MX 200 32 420 395 5075 2478WY201-072MX Φ530×12 250×350 300 859 391

WY-2592

WY201-073MX250 455 445 5050 201

2681WY201-074MX 200 50 420 395 5075 2571WY201-075MX 150 410 355 4980 2321

① Type List ② Pressure & Temperature Reducing Valve Diameter (DN1) ③ Steam Pipeline Diameter (Dw×S)④ Feed-Water Control Valve Diameter (D4) ⑤ First Main Safety Valve Inlet and Outlet Diameter (DN2×DN3)

Chart 9

⑥ Second Main Safety Valve Inlet and Outlet Diameter (DN2'×DN3') ⑦ Structure Size ⑧ Drawing Number ⑨ Total Weight (Kg)

⑦① ②

(DN1)③(Dw×S)

④(D4)

⑤(DN2×DN3)

⑥(DN2'×DN3') H b b' h1 h2 h1' h2' l Lmax

⑧ ⑨(Kg)

WY202-001MX 150 410 355 5570 2108WY202-002MX 200 20

WY202-003MX420 395 5565 2332

2225WY202-004MX

250 455 445 51902332

WY202-005MX 200

WY202-006MXΦ426×11 32 150×200 420 220 670 340 822 340 395 5565 2411

2188WY202-007MX

150 410 355 55702278

WY202-008MX 200 50

WY202-009MX420 395 5565 2502

5190 2423WY202-010MX

250 455 4455860 3141

WY202-011MX 200 20

WY202-012MX420 395 5885 3026

2778WY202-013MX

150 410 355 57902858

WY202-014MX 200

WY202-015MXΦ530×12 32 250×350 420 300 877 392 877 392 395 5885

WY-202

3106

3221WY202-016MX

250 455 445 58603312

WY202-017MX 200 50

WY202-018MX420 395 5885 3197

2948WY202-019MX

150 250×350 410 300 355 57902665

WY202-020MX 200 20

WY202-021MX420 395 5885 3162

3276WY202-022MX

250 455 445 58603356

WY202-023MX 200

WY202-024MXΦ630×12 32 420 909 441 909 441 395 5885 3241

2993WY202-025MX

150 410 355 57903083

Page 26: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing DesuperheaterWY202-026MX 200 50 420 395 5885 3332

WY202-027MX 250 455 445 5860 3447

Page 27: Desuperheater catalog of DAEJU CONTROL CO., LTD.

Chart

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Dimention Chart for Desuperheater① Type List ② Pressure & Temperature Reducing Valve Diameter (DN1) ③ Steam Pipeline Diameter (Dw×S)④ Feed-Water Control Valve Diameter (D3) ⑤ Spring Safety Diameter (DN, PN16)⑥ Structure Size ⑦ Drawing Number ⑧ Total Weight (Kg)

① ② (DN1) ③(Dw×S) ④ (D3) ⑤DN(PN16)⑥

⑦ ⑧b DN2 h l Lmax

WY205-001MX50

Φ89×4.5

20

50 135 65

283222

2146

WY-205

WY205-002MX

Φ108×4.5

2932422

WY205-003MX80 280 2030

WY205-004MX

80 170 100

308WY205-005MX

50 222 2422WY205-006MX

Φ133×6

319WY205-007MX

80 280 2030WY205-008MX

50 135 65

304WY205-009MX

50 2222422

WY205-010MX

Φ159×7

316

2672

WY205-011MX 80 280 2410

WY205-012MX100 300 2120

WY205-013MX

80 170 100 331WY205-014MX 80 280 2410

WY205-015MX50 222 2672

WY205-016MX

100 205 125 356

WY205-017MX 80 280 2410

WY205-018MX100 300 2120

WY205-019MX

32

WY205-020MX 80 280 2410

WY205-021MX50 222 2672

WY205-022MX

80 170 100 331WY205-023MX 80 280 2410

WY205-024MX50 300 2120

WY205-025MX

50 135 65 316WY205-026MX 80 280 2410

WY205-027MX 50 222 2672

Page 28: Desuperheater catalog of DAEJU CONTROL CO., LTD.

cDesuperheater & Pressure Reducing Desuperheater DAEJU CONTROL CO., LTD

Middle Pressure and Middle Temperature Desuperheater and Pressure Reducing Desuperheater

Dimention Chart for Desuperheater① Type List ② Pressure & Temperature Reducing Valve Diameter (DN1) ③ Steam Pipeline Diameter (Dw×S)④ Feed-Water Control Valve Diameter (D3) ⑤ Spring Safety Diameter (DN, PN40)⑥ Structure Size ⑦ Drawing Number ⑧ Total Weight (Kg) Chart 11

① ② (DN1) ③(Dw×S) ④ (D3) ⑤ DN(PN40)⑥

⑦ ⑧ b DN2 h l Lmax

WY206-001MX50

Φ89×4.5

20

50 135 65

326222

2146

WY-206

303

WY206-002MX

Φ108×4.5

3362422 327

WY206-003MX80 280 2030

339.5

WY206-004MX

80 170 100

361382.5

WY206-005MX50 222 2422

370

WY206-006MX

Φ133×6

372380

WY206-007MX80 280 2030

391.5

WY206-008MX

50 135 65

347350.5

WY206-009MX50 222

2422 388

WY206-010MX

Φ159×7

359

2672 374

WY206-011MX 80 280 2410 401.5

WY206-012MX100 300 2120

429

WY206-013MX

80 170 100 384

471

WY206-014MX 80 280 2410 443.5

WY206-015MX50 222 2672

416

WY206-016MX

100 200 125 419

441

WY206-017MX 80 280 2410 468.5

WY206-018MX100 300 2120

496

WY206-019MX

32

576

WY206-020MX 80 280 2410 548.5

WY206-021MX50 222 2672

521

WY206-022MX

80 170 100 384

496

WY206-023MX 80 280 2410 526

WY206-024MX100 300 2120

551

WY206-025MX

50 135 65 359

509

WY206-026MX 80 280 2410 482

WY206-027MX 50 222 2672 452

Page 29: Desuperheater catalog of DAEJU CONTROL CO., LTD.

c DAEJU CONTROL CO., LTDADDRESSRM 905, New T castle, 429-1, Gasan-Dong,Geumcheon-Gu, Seoul, South Korea

TEL. +82-2-2626-9791 FAX . +82-2-2626-9792Email : [email protected] Site : www.aov.kr