1. LTS DRAFTING & ENGINEERING WILL ASSUME NO RESPONSIBILITY FOR ERRORS RESULTING FROM THE USE OF THESE DRAWINGS BY OTHER TRADES. 2. THESE DRAWINGS HAVE BEEN PREPARED IN ACCORDANCE WITH LTS'S QUOTATION OR PER AN ACCEPTED CHANGE ORDER AND OTHER APPLICABLE CONTRACT DOCUMENTS. 3. FINAL APPROVAL BY THE GENERAL CONTRACTOR CONSTITUTES ACCEPTANCE OF ALL DEVIATIONS TO THE CONTRACT DOCUMENTS MADE BY LTS DRAFTING & ENGINEERING IN THESE DRAWINGS. 4. THESE DRAWINGS REPRESENT LTS'S INTERPRETATION OF THE APPLICATION OF PRODUCTS TO THIS PROJECT IN FUNCTIONAL COMPLIANCE WITH THE ARCHITECTS DRAWINGS AND SPECIFICATIONS. IT IS IMPORTANT THAT THIS INTERPRETATION BE REVIEWED DIMENSIONALLY AND FUNCTIONALLY WITH RESPECT TO ACTUAL ARCHITECT INTENT, INTERFACING CONDITIONS, MATERIALS AND JOB SITE CONDITIONS. 5. ALL DIMENSIONS SHALL BE FIELD VERIFIED AND/OR APPROVED BY THE GLAZING SUBCONTRACTOR PRIOR TO GLASS ORDERING AND FABRICATION. LTS DRAFTING & ENGINEERING WILL ASSUME NO RESPONSIBILITY FOR DIMENSIONAL ERRORS OR CHANGES RESULTING FROM FIELD CONDITIONS. 6. PROJECT MATERIALS MUST BE PROTECTED IMMEDIATELY FROM STAINING BY WET CARDBOARD PAPER AND FROM THE ACTION OF HARSH ALKALIS AND SAND IN CONCRETE, STUCCO, MORTAR OR PLASTER. THE SETTING OF THE PROJECT MATERIALS REQUIRES GENERAL CONTRACTOR TO CLOSELY SUPERVISE OTHER TRADES SO AS TO PREVENT MARRING OR DISCOLORATION FROM ANY CAUSE. 7. ALL SEALANT JOINTS SHOULD BE SEALED WATERTIGHT FOLLOWING THE SEALANT MANUFACTURERS RECOMMENDATIONS AS TO SIZE, METHOD OF APPLICATION AND COMPATIBILITY WITH ADJOINING MATERIALS. 8. ALL FRAMING SYSTEMS SHALL BE FABRICATED & INSTALLED PER THE MANUFACTURERS INSTRUCTIONS. SYSTEM PART NUMBERS MUST BE VERIFIED BY THE GLAZING SUBCONTRACTOR PRIOR TO ORDERING MATERIAL. LTS WILL NOT BE HELD LIABLE FOR INACCURATE SYSTEM PART NUMBERS. 9. ALL GLASS AND FINISHED MATERIAL MUST BE PROTECTED DURING WELDING OPERATIONS, FIREPROOFING OR ANY OTHER PROCESS THAT MAY BE HARMFUL TO THE APPEARANCE OR PERFORMANCE OF THE PROJECT MATERIALS. 10. THE ROUGH OPENINGS PROVIDED MUST BE SQUARE AND WITHIN SPECIFIED BUILDING TOLERANCES. 11. PERIMETER SUBSTRATE MUST BE CAPABLE OF WITHSTANDING REACTION FORCES IMPOSED BY DESIGN LOADS. 12. LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZING ENTRANCE, WINDOW AND CURTAIN WALL PRODUCTS VARY WIDELY. LTS DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE OR GLAZING MATERIALS AND ASSUMES NO RESPONSIBILITY. A PRELIMINARY STRUCTURAL REVIEW HAS BEEN PERFORMED ON THESE SHOP DRAWINGS. THIS REVIEW INCLUDED A MATERIAL CHECK OF THE EXTERIOR FRAMES TO MEET THE DESIGN CRITERIA SHOWN ON THIS SHEET. THE PERIMETER ANCHORAGE, AS SHOWN, HAS NOT BEEN REVIEWED. LTS WILL NOT BE LIABLE FOR INSUFFICIENT ANCHORING AND/OR SUBSTRATE. A PRELIMINARY STRUCTURAL REVIEW HAS BEEN PERFORMED ON THESE SHOP DRAWINGS. THIS REVIEW INCLUDED MATERIAL AND PERIMETER ANCHORAGE CHECKS OF THE EXTERIOR FRAMES TO MEET THE DESIGN CRITERIA SHOWN ON THIS SHEET. LTS WILL NOT BE LIABLE FOR INSUFFICIENT SUBSTRATE AND/OR ANCHORING WHICH DEVIATES FROM THAT SHOWN. FORMAL CALCULATIONS WILL NOT BE SUBMITTED FORMAL CALCULATIONS (EXTERIOR ELEVATIONS ONLY), SEALED BY A PROFESSIONAL ENGINEER, WILL BE SUBMITTED AFTER SHOP DRAWING APPROVAL FIRST SUBMITTAL DRAWINGS ARE PRELIMINARY AND ARE NOT SUITABLE FOR ORDERING MATERIALS A STRUCTURAL REVIEW HAS NOT BEEN PERFORMED ON THE INTERIOR FRAMING SHOWN IN THESE SHOP DRAWINGS. THE PERIMETER ANCHORAGE, AS SHOWN, HAS NOT BEEN REVIEWED. LTS WILL NOT BE LIABLE FOR THE STRUCTURAL DESIGN OF THE FRAMING OR ANCHORAGE TO THE SURROUNDING SUBSTRATES SHEET INDEX 101 COVER SHEET 102 HARDWARE SCHEDULE 201 FLOOR PLAN 301 ELEVATIONS 701-705 INTERIOR ELEVATIONS 801-803 STOREFRONT AND DOOR DETAILS 1101-1103 ALL GLASS ENTRY DETAILS 1201-1203 INTERIOR DETAILS ASD WIND SPEED (MPH): RISK CATEGORY: EXPOSURE CATEGORY: MEAN ROOF HEIGHT: ASD DESIGN PRESSURE (PSF) TYPICAL WALL: CORNER ZONES: SNOW LOAD (PSF): WINDLOADS ALLOWABLE DEFLECTION PER AAMA TIR A11 PERPENDICULAR TO FRAMING: L < 13'-6": L/175 L > 13'-6": L/240 + 1/4" MAXIMUM: 3/4" PER LITE IN-PLANE (DEADLOAD DEFLECTION): 1/8" TYPICAL 1/16" ABOVE OPERABLE PRODUCTS NOTES: 120 II C 25FT 34.7 42.7 N/A _ JAGUAR / LAND ROVER FLATIRONS ALUMINUM ENTRANCE & STOREFRONT SHOP DRAWINGS FIELD VERIFY ALL DIMENSIONS GLASS SIZE CALCULATION KAWNEER 451T 3/4" 3/8" GLASS BITE KAWNEER 190 DOORS BY KAWNEER CRL ALL GLASS DOORS BY KEN CARYL FINISH SCHEDULE PRODUCT FINISH NOTES ALL MATERIAL #14 CLEAR ANODIZED NOTES FOR BLOCKS AT NONSTANDARD LOCATIONS MEASURED FROM C BLOCK TO GLASS EDGE 8" 12" PTS. 1/8 L ROUGH OPENING VERIFY IN FIELD OVERALL FRAME DIMENSION TOP OF HORIZONTAL UNLESS NOTED OTHERWISE WIND LOAD (ANCHOR) WINDOW DIMENSION = = = W.P. WL W.D. WORKING POINT = = = = = = = = = UNO W.C. VIF T.O.STL. T.O.S. R.O. T.O.H. O.F.D. REF WEB CENTER TOP OF STEEL TOP OF SLAB REFERENCE DAYLIGHT OPENING MASONRY OPENING NOT BY KEN CARYL GLASS MULLION LENGTH GLASS SIZE DEAD LOAD (ANCHOR) ELEVATION EL. = = = = = = = = M.L. NTS N.B.K. G.S. M.O. F.F. F.S. NOT TO SCALE FRAME SIZE FINISHED FLOOR = = = = D.O. DL D.L.O. DIM DIMENSION DOOR OPENING PRODUCT DESCRIPTION PRODUCT WIDTH DEPTH KAWNEER 451T SF 2" 4 1/2" KAWNEER 190 NARROW STILE DOORS VARIES 1 3/4" CRL ALL GLASS DOORS 2" INFILL SCHEDULE GLAZING CONTRACTOR TO VERIFY CORRECT INSULATED GLASS MAKE UP AND CORRECT LOCATIONS ON ALL ELEVATIONS PRIOR TO ORDERING SYMBOL DESCRIPTION 1.00" INSULATED UNIT EXTERIOR: SOLARBAN 60 ON 1/4" CLEAR AIR SPACE: 1/2" INTERIOR: 1/4" CLEAR 1.00" INSULATED UNIT EXTERIOR: SOLARBAN 60 ON 1/4" CLEAR TEMPERED AIR SPACE: 1/2" INTERIOR: 1/4" CLEAR TEMPERED 1/2" CLEAR TEMPERED GLASS 1/2" WHITE BACK PAINTED TEMPERED GLASS = E.O.G. EDGE OF GLASS SETTING BLOCKS HARDWARE: STRUCTURAL ENGINEER OF RECORD = SEOR STOREFRONT = SF A S BS A 2 901 1 301 ELEVATION TITLE SCALE HDWR SET: 01 1 SEALANT AND BACKER ROD MULTISPAN ANCHOR LOCATION FASTENER LOCATION ANCHOR CHANNEL LOCATION WORK POINT SEALANT (BY GLAZING SUB CONTRACTOR) BRAKE METAL SPLICE INFILL KEY DOOR NUMBER REVISION DELTA FLOOR PLAN KEY DETAIL KEY ELEVATION + SECTION LABEL DETAIL LABEL MATERIALS AVAILABLE WHEN DRAWN YES NO MATERIAL LATEST ISSUE X ARCHITECTURAL DRAWINGS 7/11/17 X STRUCTURAL DRAWINGS X ADDENDUMS 10/25/17 X SPECIFICATIONS NOTES: ALUMINUM CONCRETE CONCRETE BLOCK DIMENSIONAL LUMBER FINISHED WOOD GROUT PLYWOOD SHIM PACK STEEL RIGID INSULATION BRICK CAULKING BACKER ROD = F.O. FRAME OPENING DESIGN CRITERIA GENERAL NOTES CALCULATIONS PRODUCTS USED ABBREVIATIONS HATCH SYMBOLS SERIES: ARCH REF: STRUC REF: 1 DETAIL TITLE N/A N/A N/A SCALE = CW CURTAIN WALL = CL CENTERLINE = B.O.H. BOTTOM OF HORIZONTAL = ARCH ARCHITECT STRUCTURE = STRUC CORNER ZONE WIDTH (a): 10FT AT BT CT 8670 CONCORD CENTER DRIVE ENGLEWOOD, CO 80112 PHONE: 303.858.9858 FAX: 303.858.8373 WWW.LTSDRAFTING.COM SHOP DRAWINGS FOR: ARCHITECT: GLAZING SUBCONTRACTOR: REVISIONS LTS PROJECT SCALE LTS PM LTS ENGINEER DATE 17-0148 DG BK 12-6-17 JAGUAR / LAND ROVER FLATIRONS 101 COVER SHEET FULL
18
Embed
DESIGN CRITERIAGENERAL NOTES PRODUCTS USED · elevation2/301, 3/301 qty per opening part no. & description mfg.finish 4 std top/bottom pivots crl 2 std bottom rail locks crlb/ss 2
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
1. LTS DRAFTING & ENGINEERING WILL ASSUME NO RESPONSIBILITY FOR ERRORS RESULTING FROM THE USE OF THESEDRAWINGS BY OTHER TRADES.
2. THESE DRAWINGS HAVE BEEN PREPARED IN ACCORDANCE WITH LTS'S QUOTATION OR PER AN ACCEPTED CHANGEORDER AND OTHER APPLICABLE CONTRACT DOCUMENTS.
3. FINAL APPROVAL BY THE GENERAL CONTRACTOR CONSTITUTES ACCEPTANCE OF ALL DEVIATIONS TO THE CONTRACTDOCUMENTS MADE BY LTS DRAFTING & ENGINEERING IN THESE DRAWINGS.
4. THESE DRAWINGS REPRESENT LTS'S INTERPRETATION OF THE APPLICATION OF PRODUCTS TO THIS PROJECT INFUNCTIONAL COMPLIANCE WITH THE ARCHITECTS DRAWINGS AND SPECIFICATIONS. IT IS IMPORTANT THAT THISINTERPRETATION BE REVIEWED DIMENSIONALLY AND FUNCTIONALLY WITH RESPECT TO ACTUAL ARCHITECT INTENT,INTERFACING CONDITIONS, MATERIALS AND JOB SITE CONDITIONS.
5. ALL DIMENSIONS SHALL BE FIELD VERIFIED AND/OR APPROVED BY THE GLAZING SUBCONTRACTOR PRIOR TO GLASSORDERING AND FABRICATION. LTS DRAFTING & ENGINEERING WILL ASSUME NO RESPONSIBILITY FOR DIMENSIONALERRORS OR CHANGES RESULTING FROM FIELD CONDITIONS.
6. PROJECT MATERIALS MUST BE PROTECTED IMMEDIATELY FROM STAINING BY WET CARDBOARD PAPER AND FROM THEACTION OF HARSH ALKALIS AND SAND IN CONCRETE, STUCCO, MORTAR OR PLASTER. THE SETTING OF THE PROJECTMATERIALS REQUIRES GENERAL CONTRACTOR TO CLOSELY SUPERVISE OTHER TRADES SO AS TO PREVENT MARRING ORDISCOLORATION FROM ANY CAUSE.
7. ALL SEALANT JOINTS SHOULD BE SEALED WATERTIGHT FOLLOWING THE SEALANT MANUFACTURERS RECOMMENDATIONSAS TO SIZE, METHOD OF APPLICATION AND COMPATIBILITY WITH ADJOINING MATERIALS.
8. ALL FRAMING SYSTEMS SHALL BE FABRICATED & INSTALLED PER THE MANUFACTURERS INSTRUCTIONS. SYSTEM PARTNUMBERS MUST BE VERIFIED BY THE GLAZING SUBCONTRACTOR PRIOR TO ORDERING MATERIAL. LTS WILL NOT BE HELDLIABLE FOR INACCURATE SYSTEM PART NUMBERS.
9. ALL GLASS AND FINISHED MATERIAL MUST BE PROTECTED DURING WELDING OPERATIONS, FIREPROOFING OR ANY OTHERPROCESS THAT MAY BE HARMFUL TO THE APPEARANCE OR PERFORMANCE OF THE PROJECT MATERIALS.
10. THE ROUGH OPENINGS PROVIDED MUST BE SQUARE AND WITHIN SPECIFIED BUILDING TOLERANCES.
11. PERIMETER SUBSTRATE MUST BE CAPABLE OF WITHSTANDING REACTION FORCES IMPOSED BY DESIGN LOADS.
12. LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZING ENTRANCE, WINDOW ANDCURTAIN WALL PRODUCTS VARY WIDELY. LTS DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS,OPERATING HARDWARE OR GLAZING MATERIALS AND ASSUMES NO RESPONSIBILITY.
A PRELIMINARY STRUCTURAL REVIEW HAS BEEN PERFORMED ON THESE SHOP DRAWINGS. THIS REVIEW INCLUDED AMATERIAL CHECK OF THE EXTERIOR FRAMES TO MEET THE DESIGN CRITERIA SHOWN ON THIS SHEET. THE PERIMETERANCHORAGE, AS SHOWN, HAS NOT BEEN REVIEWED. LTS WILL NOT BE LIABLE FOR INSUFFICIENT ANCHORING AND/ORSUBSTRATE.
A PRELIMINARY STRUCTURAL REVIEW HAS BEEN PERFORMED ON THESE SHOP DRAWINGS. THIS REVIEW INCLUDEDMATERIAL AND PERIMETER ANCHORAGE CHECKS OF THE EXTERIOR FRAMES TO MEET THE DESIGN CRITERIA SHOWN ON THISSHEET. LTS WILL NOT BE LIABLE FOR INSUFFICIENT SUBSTRATE AND/OR ANCHORING WHICH DEVIATES FROM THAT SHOWN.
FORMAL CALCULATIONS WILL NOT BE SUBMITTED
FORMAL CALCULATIONS (EXTERIOR ELEVATIONS ONLY), SEALED BY A PROFESSIONAL ENGINEER, WILL BESUBMITTED AFTER SHOP DRAWING APPROVAL
FIRST SUBMITTAL DRAWINGS ARE PRELIMINARY AND ARE NOT SUITABLE FOR ORDERING MATERIALS
A STRUCTURAL REVIEW HAS NOT BEEN PERFORMED ON THE INTERIOR FRAMING SHOWN IN THESE SHOP DRAWINGS. THEPERIMETER ANCHORAGE, AS SHOWN, HAS NOT BEEN REVIEWED. LTS WILL NOT BE LIABLE FOR THE STRUCTURAL DESIGN OFTHE FRAMING OR ANCHORAGE TO THE SURROUNDING SUBSTRATES
SHEET INDEX
101 COVER SHEET102 HARDWARE SCHEDULE
201 FLOOR PLAN
301 ELEVATIONS701-705 INTERIOR ELEVATIONS801-803 STOREFRONT AND DOOR DETAILS
DOOR HARDWARE - SET #3ADOOR SWING SINGLE - INSWING
DOOR NO. 135a,136a
ELEVATION I13/704,
QTY PEROPENING PART NO. & DESCRIPTION MFG. FINISH
1 STD TOP/BOTTOM PIVOTS CRL
1 CONCEALED OVERHEAD CLOSERS CRL
1 24" LADDER PULL CRL BR/SS
NOTE:
8670 CONCORD CENTER DRIVE
ENGLEWOOD, CO 80112
PHONE: 303.858.9858
FAX: 303.858.8373
WWW.LTSDRAFTING.COM
SHOP DRAWINGS FOR:
ARCHITECT:
GLAZING SUBCONTRACTOR:
RE
VIS
IO
NS
LTS PROJECT
SCALE
LTS PM
LTS ENGINEER
DATE
17-0148
DG
BK
12-6-17
JAGUAR / LAND ROVER
FLATIRONS
102
HARDWARE
SHEET
FULL
CORNER ZONE:R = 10'-0" TYP
2
2.8
A
1
ARCH. REF.: 1/A1.1
4
E
5
301
B
1
301
3
H
F
1201
FLOOR PLAN
5
301
4
301
5
301
1
301
OPP
ELEVATION RECAP
1/301: 1 THUS WEST1/301 OPP: 1 THUS EAST2/301: 1 THUS WEST (EXT)3/301: 1 THUS WEST (INT)4/301: 1 THUS NORTH4/301 OPP: 1 THUS SOUTH5/301: 3 THUS NORTH
2
301
100B
100A
3
301
137A
4
301OPP106A
137F
107A
4.2
126a116a
I1
701
I1A
702
112a
I4
701
I5
701
I6
701
111a
108a 109a 110aI7
702
I8
702
I9
702
I10
702127a 128a 129a
I10
702
OPP.
I11
703
I10
702I12
703
I13
704
135a
136a
I14
704
133a
134a
I15
705
I16
705
I17
705
INTERIOR ELEVATION RECAP
I1/701: 1 THUS DISPATCH OFFICE 116I1A/702: 1 THUS PARTS MANAGER 126I2/701: REMOVEDI3/701: 1 THUS SERVICE MANAGER 124I4/701: 1 THUS SERVICE DRIVE 137I5/701: 1 THUS SERVICE DRIVE 137I6/701: 1 THUS INVENTORY MANAGER 112I6/701: 1 THUS MARKETING MANAGER 111I7/702: 1 THUS OFFICE 108I8/702: 1 THUS OFFICE 108I9/702: 1 THUS BUSINESS MANAGER 109/CENTER MANAGER 110I10/702: 2 THUS CENTER MANAGER 110/NEW CAR MANAGER 129I10/702: 1 OPP INTERNET MANAGER 127I11/703: 1 THUS IM 127, UCM 128, NCM 129I12/703: 1 THUS NEW CAR SERVICE 135I13/704: 1 THUS NEW CAR DELIVERY 135,136I14/704: 1 THUS NEW CAR DELIVERY 135I14/704: 1 THUS NEW CAR DELIVERY 136I15/705: 1 THUS F&I OFFICE 133I16/705: 1 THUS F&I OFFICE 133I17/705: 1 THUS F&I OFFICE 134I18/705: 1 THUS BUSINESS MANAGER OFFICE 109I19/703: 1 THUS BUSINESS MANAGER 109/CENTER MANAGER 110I19/703: 1 THUS INTERNET MANAGER 127/USED CAR MANAGER 128I19/703: 1 THUS USED CAR MANAGER 128/NEW CAR MANAGER 129
109b
I18
705
124
MANAGERSERVICE
126
MANAGERPARTS
137
DRIVESERVICE
112
MANAGERINVENTORY
111
OFFICEMARKETING
108
OFFICE
109
MANAGERBUSINESS
114
OFFICEBUSINESS
110
MANAGERCENTER
127
MANAGERINTERNET
128
MANAGERUSED CAR
129
MANAGERNEW CAR
133
OFFICEF&I
134
OFFICEF&I
136
DELIVERNEW CAR
135
DELIVERNEW CAR
I19
703
I19
703
I19
703
I14
704
1
8670 CONCORD CENTER DRIVE
ENGLEWOOD, CO 80112
PHONE: 303.858.9858
FAX: 303.858.8373
WWW.LTSDRAFTING.COM
SHOP DRAWINGS FOR:
ARCHITECT:
GLAZING SUBCONTRACTOR:
RE
VIS
IO
NS
LTS PROJECT
SCALE
LTS PM
LTS ENGINEER
DATE
17-0148
DG
BK
12-6-17
JAGUAR / LAND ROVER
FLATIRONS
PLANNORTH
201
FLOOR PLAN
SHEET
1/8"=1'-0"
PLAN FOR LOCATION PURPOSES ONLY,DO NOT SCALE. ELEVATION DRAWNFROM EXTERIOR OF BUILDING, TYPICAL
FIELD VERIFY ALL DIMENSIONS
[2] REQ'D THUS TOTAL (1) FIRST FLOOR, WEST (1) FIRST FLOOR, EAST (OPP)KAWNEER 451T SF (2" X 4 1/2") OUTSIDE GLAZED, SCREW SPLINE/SHEAR BLOCKKAWNEER 190 NARROW STILE DOOR (OUTSWING)
1301
DOOR ELEVATION1/2' = 1'
[1] REQ'D THUS TOTAL (1) FIRST FLOOR, SOUTHCRL 4" ALL GLASS ENTRY DOORS
2301
EXTERIOR ENTRY ELEVATION1/2' = 1'
3301
INTERIOR ENTRY ELEVATION1/2' = 1'[1] REQ'D THUS TOTAL
(1) FIRST FLOOR, VESTIBULE 100CRL 4" ALL GLASS ENTRY DOORS
[2] REQ'D THUS TOTAL (1) FIRST FLOOR, NORTH (1) FIRST FLOOR, SOUTH (OPP)KAWNEER 451T SF (2" X 4 1/2") OUTSIDE GLAZED, SCREW SPLINE/SHEAR BLOCKKAWNEER 190 NARROW STILE DOOR (OUTSWING)
4301
DOOR ELEVATION1/2' = 1'
[3] REQ'D THUS TOTAL (3) FIRST FLOOR, NORTHKAWNEER 451T SF (2" X 4 1/2") OUTSIDE GLAZED, SCREW SPLINE
GLASS NOT IN THIS SUBMITTALNOTE:ADJECENT GLASS WALL NOT IN CURRENT SCOPE.DOOR JAMB HAS BEEN DESIGNED TO CARRY 2.5' OFTRIBUTARY WIDTH WIND LOAD FROM THIS GLASSWALL.
(1) THUS BUSINESS MANAGER 109/CENTER MANAGER 110 (1) THUS INTERNET MANAGER 127/USED CAR MANAGER 128 (1) THUS USED CAR MANAGER 128/NEW CAR MANAGER 129CRL PRODUCTS
22 1/16" R.O. TO W.P. [1'-10116"]
V.I.F.
1/4"
21 9/16"F.S./U-CHANNEL LENGTH V.I.F.
21 13/16"
G.S.
108"
R.O
. [9'-0
"]V.
I.F.
4"99
1/2"
D.L.O
.
4"
1/4"
1/4"
BT
1
1102
OPP.
3
1101
4
1202
OPP.
4
1101
I19/703
I9/70
2
I19/703
I11/70
3
1
1203
WHERE OCCURS
D.O. D.O. D.O. D.O. D.O. D.O.
107 1
/2" F
.S.
1/4"
107 1
/2" F
.S.
1/4"1/4"
107 1
/2" F
.S.
I11/703
I19/70
3
I11/703
I19/70
3
8670 CONCORD CENTER DRIVE
ENGLEWOOD, CO 80112
PHONE: 303.858.9858
FAX: 303.858.8373
WWW.LTSDRAFTING.COM
SHOP DRAWINGS FOR:
ARCHITECT:
GLAZING SUBCONTRACTOR:
RE
VIS
IO
NS
LTS PROJECT
SCALE
LTS PM
LTS ENGINEER
DATE
17-0148
DG
BK
12-6-17
JAGUAR / LAND ROVER
FLATIRONS
703
INT. ELEVATION
SHEET
1/2"=1'-0"
FIELD VERIFY ALL DIMENSIONS
I13704
INTERIOR ELEVATION1/2' = 1'
I14704
INTERIOR ELEVATION1/2' = 1'
[1] REQ'D THUS TOTAL (1) THUS NEW CAR DELIVERY 136, NEW CAR DELIVERY 135CRL PRODUCTS
[2] REQ'D THUS TOTAL (1) THUS NEW CAR DELIVERY 135 (1) THUS NEW CAR DELIVERY 136CRL PRODUCTS