Top Banner
Design and Performance Of A Thermal Neutron Beam for Boron Neutron Capture Therapy At The University Of Missouri Research Reactor J.D. Brockman J.C. McKibben
25

Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

Apr 28, 2018

Download

Documents

dodat
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

Design and Performance Of A Thermal Neutron

Beam for Boron Neutron Capture Therapy At The

University Of Missouri Research Reactor

J.D. Brockman

J.C. McKibben

Page 2: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

Neutron 5 mm

10 mm

Gamma (0.48 MeV)

a (+2) (1.49 MeV)

10 B

7Li(+3)

(0.85 MeV)

In situ activation reaction, 10B(n, a) 7Li; releases ionizing

energy within volume of single cancer cell:

Targets of traditional

and current interest:

•High-grade Glioma

•Primary and Metastatic

Melanoma

•Head and Neck Tumors

•Metastatic Liver Tumors

Current FDA

approved boron

delivery agents:

•BSH: Sodium

Borocaptate

•BPA: Borono-

phenylalanine

•GB-10:

Na2B10H10

Page 3: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

• Thermal neutron beam – Au cadmium ratio >100

– Th flux ~1X109 n/cm2/s

• Minimize gamma dose

• Irradiation facility accessible during reactor operation

• Irradiate small animals up to large dogs

Page 4: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

Silicon Bismuth

Key Design Feature: Single Crystal Silicon and Single

Crystal Bismuth Neutron Filters

Page 5: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

Si (Natural) 209Bi

Silicon and Bismuth Total Cross Sections

(Amorphous)

Source: OECD-NEA (Janis)

1 eV

1 eV

Page 6: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

Thermal Cross Sections for Silicon and Bismuth

Source: Kim et al. Phys. Med. Bio (2007)

Lee, Byung-Chul, 2007 KAERI, Private communication.

Freund (1983)

Page 7: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

ENDF/B

Nuclear

Data

COMBINE 7.1 (W.Yoon,

INL)

DORT 2D Sn

Angular Neutron Flux at

Silicon Filter Entrance

MCNP5 Monte Carlo

KAERI

Data for

S.C. Si

and Bi

59-Group ENDF/B–VII

Custom Library

Neutron Flux

at Irradiation

location

S. R. Slattery, D. W. Nigg, J. D. Brockman, M. F. Hawthrone, PHYSOR, May 9 2010, Pittsburg, Pa

ENDF/B

Nuclear Data

Page 8: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

59 group Source

from DORT

calculation

Page 9: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

Energy, MeV

1e-9 1e-8 1e-7 1e-6 1e-5 1e-4 1e-3 1e-2 1e-1 1e+0 1e+1 1e+2

Flu

x/leth

arg

y

1e+4

1e+5

1e+6

1e+7

1e+8

1e+9

1e+10

Empty Beam Tube

50 cm Silicon Crystal

50 cm Si + 8 cm Bi

Page 10: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

1. Voided Beam

2. 50 cm Silicon crystal

3. 8 cm Bismuth Crystal

4. 50 cm Silicon + 8 cm Bismuth Crystal

Page 11: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

Voided

Beamline

8 cm Bi

Crystal

50 cm Si

Crystal

50 cm Si +

8 cm Bi

Measured

Thermal Flux

(n/cm2-s)

9.8 x 109

(11%)

3.4 x 109

(8%)

2.6 x 109

(8%)

9.4 x 108

(8%)

Calculated

Thermal Flux

DORT +

MCNP5

(n/cm2-s)

9.4 x 109

(10%)

3.8 x 109

(10%)

2.2 x 109

(10%)

9.6 x 108

(10%)

Cadmium

Ratio

3.18

(7%)

5.10

(7%)

65.3

(7%)

105.5

(7%)

Wire

saturation

activity ratio

(Au/Cu)

36.4 28.4 22.4 22.4

Page 12: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research
Page 13: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

Neutron

Interaction

Energy Range

of Primary

Response

Activation

Gamma

Energy

(keV)

6 –Group

spectrum

197Au (n, γ) Bare Foil 55Mn (n, γ) Bare Foil

Thermal

Thermal

411

847

1

115In (n, γ) Cd Cover 1 eV Resonance 1293 2

197Au (n, γ) Cd Cover 5 eV Resonance 411 3

186W (n, γ) Cd Cover 18 eV Resonance 686 4

55Mn (n, γ) Cd Cover 340 eV Resonance 847 5

63Cu (n, γ) Cd Cover 1 keV Resonance 511 (Positron) 5

115In (n,n') Boron

Sphere

300 keV Threshold 336 6

Page 14: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research
Page 15: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

1.E+05

1.E+06

1.E+07

1.E+08

1.E+09

1.E-04 1.E-02 1.E+00 1.E+02 1.E+04 1.E+06 1.E+08

Flu

x/L

eth

arg

y

Energy, eV

6 Group spectrum 2012

group 1

group 2

group 3

group 4

group 5

group 6

A-Priori

Bare Au, Mn

Cd In

Cd Au

Cd W

Cd Cu, Mn

B In

Nigg, et al, Med Phys. 27 359-367

Page 16: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

• Measured Φth 2012 = 7.65 x 108 n/cm2-s (±8.6%)

• Measured Φth 2009 = 8.85 x 108 n/cm2-s (±8.3%)

• Measured Φth 2008 = 8.18 x 108 n/cm2-s (±6.0%)

• Calculated Φ = 9.6 x 108 n/cm2-s (±5%)

• Cadmium Ratio (Au) = 108

• Calculated Dγ = 2.12 cGy/min

• Measured Dγ = 3.4 cGy/min (paired ion chamber technique)

Page 17: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

Energy Group

0 1 2 3 4 5 6

n/cm

2 /s

1e+5

1e+6

1e+7

1e+8

Gro

up 6

n/c

m2 /s

1e+8

1e+9

2008

2009

2012

Page 18: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

Mean Au activity: 9.73X1014 dps/n ± 4%

Mean Au/Cu ratio: 22.1 ± 1.7%

Cu/Au wires

Page 19: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

Profile

flux wire

Center, index

wire

Phantom A Phantom B

Phantom C

Phantom D

Profile

flux wire

Start of

Shielding

Page 20: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

0

20

40

60

80

100

120

140

160

180

-4.0 -3.0 -2.0 -1.0 0.0 1.0 2.0

Au A

ctiv

ity R

ela

tive to c

ente

r w

ire

Distance in cm from top edge of black cap

Phantom A

Phantom B

Inside Shielding

Phantom

inside beam

Start of Li Carbonate

neutron shielding Edge of animal holder

Center of

Beam

Page 21: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

0

50

100

150

200

250

0 2 4 6 8

Cu a

ctiv

ity, re

lative to c

ente

r w

ire

Length, cm

Phantom D

Front

Back

Li Shielding Start

Cap Start

Page 22: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research
Page 23: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

Tumor Flank

downstream thorax in

beam thorax down

stream

Thermal Flux,

n/cm^2/s 1.3X109 1.9X108 1.3X108 7.1EX107

Thermal Flux

Relative to

tumor 100% 14% 10% 5%

Tumor

Flank

Downstream

Thorax

upstream

Thorax

Down Stream

6Li shield

Page 24: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

• Neutron spectrum has not changed since 2008

• Radial profile measurements

• Phantom measurements and animal experiments are

underway

Acknowledgements Dr. David Nigg INL

Dr. Frederick Hawthorne IINMM

MURR Staff

Operations

Health Physics

Machine Shop

Electrical Shop

Page 25: Design and Performance Of A Thermal Neutron Beam for … · Design and Performance Of A ... Beam Line at the University of Missouri Research Reactor ... neutron beam for BNCT research

[1] J. D. Brockman, D. W. Nigg, M. F. Hawthorne, M.W. Lee, J. C. McKibben, “Characterization of a Boron Neutron Capture Therapy

Beam Line at the University of Missouri Research Reactor” J. Radioanal. Nucl. Ch. 282 157-160

[2] E.C.C. Pozzi, S. Thorp, J. D. Brockman, M. Miller, D. W. Nigg, F. M. Hawthorne, Intercalibration of Physical Neutron Dosimetry for

the RA-3 and MURR Thermal Neutron Sources for BNCT Small-Animal Research” Appl. Radiat. Isotopes. 69 1921-1923

[3] M. S. Kim, B. C. Lee, S. Y. Hwang, B. J. Jun, “Development and characteristics of the HANARO neutron irradiation facility for

applications in the boron neutron capture therapy field” Phys. Med. Biol. 52 2553-2566

[4] R. F. Barth, et. Al., “Current status of boron neutron capture therapy of high grade gliomas and recurrent head and neck cancer”

Radiat. Oncol. 2012, 7 146-167

[5] J. D. Brockman, D. W. Nigg, M. F. Hawthorne, J. C. McKibben, ”Spectral performance of a composite single-crystal filtered thermal

neutron beam for BNCT research at the University of Missouri” Appl. Radiat. Isotopes. 67 S222-S225

[6] B. C. Lee, Korean Atomic Energy Research Institute, Private communication (2007)

[7] A. K. Freund, “Cross Sections of Materials used as Neutron Monochromators and Filters”, Nucl. Instrum. & Methods, 243 495-501.

[8] W. A. Rhoades et al., :Tort-Dort: Two and Three-Dimensional Discrete-Ordinates Transport”, Radiation Shielding Information

Center, Oak Ridge National Laboratory, USA 1980.

[9] S. R. Slattery, D. W. Nigg, J. D. Brockman, M. F. Hawthrone, “Improved computational characterization of the thermal neutron source

for neutron capture therapy at the University of Missouri” PHYSOR, May 9 2010, Pittsburg, Pa

[10] D. W. Nigg et al., “Modification of the University of Washington Neutron Radiotherapy Facility for Optimization of Neutron

Capture Enhanced Fast Neutron Therapy” Med. Phys. 27 359-367