THE STATE OF CONNECTICUT DEPARTMENT OF HOUSING (DOH) COMMUNITY DEVELOPMENT BLOCK GRANT-DISASTER RECOVERY PROGRAM (CDBG-DR) OWNER-OCCUPIED REHABILITATION AND REBUILDING PROGRAM (OORR) STORM SANDY RELIEF GOVERNOR DANNEL P. MALLOY COMMISSIONER OF HOUSING EVONNE M. KLEIN APPLICATION NO. 1405 9 DERBY AVE MILFORD, CT 06460 APRIL 2016 COVER SHEET NOTES: REVISIONS CHECKED BY: DRAWN BY: SHEET: DATE: SCALE: DTC DRAWING FILE: DTC PROJECT NUMBER: AUGUST 2015 13-449-014 OORR APPLICATION NO. 1405 MACIAG RESIDENCE 9 DERBY AVE MILFORD, CT 2321 Whitney Avenue - Hamden Center II - Hamden CT 06518 Ph: 203 239 4200 Fax: 203 234 7376 www.teamdtc.com G-100 DRAWING INDEX G-100 C-100 D-101 A-101 A-201 A-301 MP-001 M-100 M-101 MP-300 E-001 E-100 COVER SHEET SITE PLAN GROUND, FIRST FLOOR & SECOND FLOOR DEMOLITION PLANS GROUND, FIRST FLOOR & SECOND FLOOR PLANS ELEVATIONS SECTIONS & DETAILS MECHANICAL & PLUMBING NOTES, LEGENDS, & ABBREVIATIONS MECHANICAL FLOOR PLANS GROUND AND FIRST FLOORS MECHANICAL FLOOR PLANS SECOND FLOORS MECHANICAL & PLUMBING SCHEDULES & DETAILS ELECTRICAL NOTES, LEGENDS, ABBREVIATIONS, & DETAILS ELECTRICAL FLOOR PLANS PROPERTY LOCATION
12
Embed
DEPARTMENT OF HOUSING (DOH) COMMUNITY ......N/F THOMAS R. WERNER & SUSAN E. WERNER VOL. 3614 PG. 304 N/F MARGARITA M. BARAB VOL. 2371 PG. 71 N/F ANTHONY BUONO VOL. 3279 PG. 18 N/F
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
THE STATE OF CONNECTICUT
DEPARTMENT OF HOUSING (DOH)
COMMUNITY DEVELOPMENT BLOCK GRANT-DISASTER RECOVERY PROGRAM
(CDBG-DR)
OWNER-OCCUPIED REHABILITATION AND REBUILDING PROGRAM (OORR)
STORM SANDY RELIEF
GOVERNORDANNEL P. MALLOY
COMMISSIONER OF HOUSING EVONNE M. KLEIN
APPLICATION NO. 14059 DERBY AVE
MILFORD, CT 06460 APRIL 2016
COVER SHEET
NOTES:
REVISIONS
CHECKED BY:
DRAWN BY:
SHEET:
DATE:
SCALE:
DTC DRAWING FILE:
DTC PROJECT NUMBER:
AUGUST 2015
13-449-014
OORRAPPLICATION NO. 1405
MACIAG RESIDENCE 9 DERBY AVEMILFORD, CT
2321 Whitney Avenue - Hamden Center II - Hamden CT 06518Ph: 203 239 4200 Fax: 203 234 7376
www.teamdtc.com
G-100
DRAWING INDEX
G-100
C-100
D-101A-101A-201A-301
MP-001 M-100 M-101 MP-300
E-001E-100
COVER SHEET
SITE PLAN
GROUND, FIRST FLOOR & SECOND FLOOR DEMOLITION PLANS GROUND, FIRST FLOOR & SECOND FLOOR PLANS ELEVATIONSSECTIONS & DETAILS
MECHANICAL & PLUMBING NOTES, LEGENDS, & ABBREVIATIONS MECHANICAL FLOOR PLANS GROUND AND FIRST FLOORS MECHANICAL FLOOR PLANS SECOND FLOORSMECHANICAL & PLUMBING SCHEDULES & DETAILS
2321 Whitney Avenue - Hamden Center II - Hamden CT 06518Ph: 203 239 4200 Fax: 203 234 7376
www.teamdtc.com
AS NOTED
SITE PLAN
C-100JAB
EPZ
xx x
GRAPHIC SCALE
( IN FEET )
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WG
AutoCAD SHX Text
WG
AutoCAD SHX Text
WG
AutoCAD SHX Text
C
AutoCAD SHX Text
A
AutoCAD SHX Text
SAN MH TF=5.38' INV.=(-3.5')
AutoCAD SHX Text
STOCKADE FENCE
AutoCAD SHX Text
STOCKADE FENCE
AutoCAD SHX Text
STOCKADE FENCE
AutoCAD SHX Text
GARAGE
AutoCAD SHX Text
2 STORY WOOD FRAME PEAK OF ROOF ELEV= 39.15'
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
UPPER LEVEL BALCONY
AutoCAD SHX Text
WOOD DECK
AutoCAD SHX Text
LOWER LEVEL ELEV= 6.34'
AutoCAD SHX Text
FF=14.28'
AutoCAD SHX Text
STONE PATIO
AutoCAD SHX Text
SHOWER AREA BELOW
AutoCAD SHX Text
BRICK PAVERS
AutoCAD SHX Text
STONE WALKWAY
AutoCAD SHX Text
CONC. PAD
AutoCAD SHX Text
5.4
AutoCAD SHX Text
5.3
AutoCAD SHX Text
5.8
AutoCAD SHX Text
5.8
AutoCAD SHX Text
5.4
AutoCAD SHX Text
5.3
AutoCAD SHX Text
5.7
AutoCAD SHX Text
5.9
AutoCAD SHX Text
5.2
AutoCAD SHX Text
5.2
AutoCAD SHX Text
5.2
AutoCAD SHX Text
4.7
AutoCAD SHX Text
4.8
AutoCAD SHX Text
4.9
AutoCAD SHX Text
5.0
AutoCAD SHX Text
4.4
AutoCAD SHX Text
4.5.
AutoCAD SHX Text
5.4
AutoCAD SHX Text
5.3
AutoCAD SHX Text
5.4
AutoCAD SHX Text
5.4
AutoCAD SHX Text
5.8
AutoCAD SHX Text
5.8
AutoCAD SHX Text
5.3
AutoCAD SHX Text
5.3
AutoCAD SHX Text
5.3
AutoCAD SHX Text
5.2
AutoCAD SHX Text
5.2
AutoCAD SHX Text
5.2
AutoCAD SHX Text
EM
AutoCAD SHX Text
6" CEDAR (TYP.)
AutoCAD SHX Text
10" CEDAR
AutoCAD SHX Text
10" CEDAR
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
SAN MH TF=5.36'
AutoCAD SHX Text
CL CB TF=4.94'
AutoCAD SHX Text
CONC. CURB
AutoCAD SHX Text
5' DIAM. SHRUB
AutoCAD SHX Text
BIT. PAVEMENT
AutoCAD SHX Text
5' EASEMENT AS DEPICTED ON MAP REFERENCE "B"
AutoCAD SHX Text
GM
AutoCAD SHX Text
WATER METER
AutoCAD SHX Text
SEE NOTE "6"
AutoCAD SHX Text
Street Line
AutoCAD SHX Text
Silt Fence
AutoCAD SHX Text
Chain Link Fence
AutoCAD SHX Text
Wooden Rail Fence
AutoCAD SHX Text
Item to be Demolished
AutoCAD SHX Text
NOTES 1.ALL DISTURBED AREAS NOT TO BE OTHERWISE PAVED OR COVERED SHALL BE LOAM & SEEDED. ALL DISTURBED AREAS NOT TO BE OTHERWISE PAVED OR COVERED SHALL BE LOAM & SEEDED. 2.CALL BEFORE YOU DIG - THE CONTRACTOR IS HEREBY REMINDED THAT THE CONNECTICUT GENERAL STATUES CALL BEFORE YOU DIG - THE CONTRACTOR IS HEREBY REMINDED THAT THE CONNECTICUT GENERAL STATUES REQUIRE NOTICE TO UTILITY COMPANIES PENDING EXCAVATION AT OR NEAR PUBLIC UTILITIES. THE CONTRACTOR SHALL CALL 1-800-922-4455 AT LEAST 72 HOURS PRIOR TO EXCAVATING AT ANY LOCATION. A COPY OF THE CALL BEFORE YOU DIG PROJECT REFERENCE NUMBERS SHALL BE GIVEN TO THE OWNER PRIOR TO EXCAVATION. 3.SOIL EROSION AND SEDIMENT CONTROL MEASURES SHALL CONFORM TO THE STATE OF CONNECTICUT 2002 SOIL EROSION AND SEDIMENT CONTROL MEASURES SHALL CONFORM TO THE STATE OF CONNECTICUT 2002 GUIDELINES FOR SOIL EROSION AND SEDIMENT CONTROL AS AMENDED THROUGH BID DATE OF THIS PROJECT 4.PROTECT EXISTING VEGETATION ON PROPERTY NOT WITHIN CONSTRUCTION AREA. COORDINATE WITH HOMEOWNER. PROTECT EXISTING VEGETATION ON PROPERTY NOT WITHIN CONSTRUCTION AREA. COORDINATE WITH HOMEOWNER. 5.CONTRACTOR SHALL NOT STORE EXCESS SOIL WITHIN PROPERTY LIMITS. CONTRACTOR SHALL NOT STORE EXCESS SOIL WITHIN PROPERTY LIMITS. 6.NO WORK OR STORING OF MATERIALS ALLOWED WITHIN COASTAL JURISDICTION AREA.NO WORK OR STORING OF MATERIALS ALLOWED WITHIN COASTAL JURISDICTION AREA.
AutoCAD SHX Text
Property Line
AutoCAD SHX Text
Building Setback Line
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
Proposed Spot Elevation
AutoCAD SHX Text
Test Boring Location
AutoCAD SHX Text
B-1
AutoCAD SHX Text
Iron Pin (Found)
AutoCAD SHX Text
Monument (Found)
AutoCAD SHX Text
Sign
AutoCAD SHX Text
Manhole
AutoCAD SHX Text
"C" Catch Basin
AutoCAD SHX Text
"C-L" Catch Basin
AutoCAD SHX Text
Utility Pole
AutoCAD SHX Text
Mail Box
AutoCAD SHX Text
Shrub/Bush
AutoCAD SHX Text
Deciduous Trees
AutoCAD SHX Text
Evergreen Trees
AutoCAD SHX Text
T
AutoCAD SHX Text
Light Pole
AutoCAD SHX Text
Metal Post
AutoCAD SHX Text
Guy Anchor
AutoCAD SHX Text
Water Gate
AutoCAD SHX Text
Gas Meter
AutoCAD SHX Text
Gas Valve
AutoCAD SHX Text
GV
AutoCAD SHX Text
WG
AutoCAD SHX Text
GM
AutoCAD SHX Text
E
AutoCAD SHX Text
W
AutoCAD SHX Text
\\
AutoCAD SHX Text
G
AutoCAD SHX Text
Underground
AutoCAD SHX Text
Piping (San.,Stm.)
AutoCAD SHX Text
U/G Elec. Line
AutoCAD SHX Text
Water Line
AutoCAD SHX Text
Overhead Utilities
AutoCAD SHX Text
U/G Tele. Line
AutoCAD SHX Text
Chain Link Fence
AutoCAD SHX Text
Tree Line
AutoCAD SHX Text
Stone Wall
AutoCAD SHX Text
U/G Gas Line
AutoCAD SHX Text
Rebar To Be Set
AutoCAD SHX Text
STANDARD
AutoCAD SHX Text
LOT AREA (S.F.) (MINIMUM)
AutoCAD SHX Text
LOT WIDTH (MINIMUM)
AutoCAD SHX Text
LOT DEPTH (MINIMUM)
AutoCAD SHX Text
HEIGHT (MAXIMUM)
AutoCAD SHX Text
SETBACK FROM STREET LINE
AutoCAD SHX Text
SETBACK FROM REAR LINE
AutoCAD SHX Text
SETBACK FROM SIDE LINE ONE SIDE
AutoCAD SHX Text
BUILDING AREA AS % LOT
AutoCAD SHX Text
REQUIRED
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
PROPOSED
AutoCAD SHX Text
5,000
AutoCAD SHX Text
50'
AutoCAD SHX Text
70'
AutoCAD SHX Text
35'
AutoCAD SHX Text
10'
AutoCAD SHX Text
20'
AutoCAD SHX Text
10'
AutoCAD SHX Text
5'
AutoCAD SHX Text
45%
AutoCAD SHX Text
2,974
AutoCAD SHX Text
40.42'
AutoCAD SHX Text
73.45'
AutoCAD SHX Text
30.22'
AutoCAD SHX Text
9.67'
AutoCAD SHX Text
17.00'
AutoCAD SHX Text
6.98'
AutoCAD SHX Text
6.10'
AutoCAD SHX Text
22.9%
AutoCAD SHX Text
EXIST. TO REMAIN
AutoCAD SHX Text
EXIST. TO REMAIN
AutoCAD SHX Text
EXIST. TO REMAIN
AutoCAD SHX Text
LOT COVERAGE (MAXIMUM)
AutoCAD SHX Text
65%
AutoCAD SHX Text
43.8%
AutoCAD SHX Text
STORIES (MAXIMUM)
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
SURVEY INFORMATION IS BASED ON A-2 SURVEY MAP PREPARED BY: MARTIN SURVEYING ASSOCIATES, LLC DATED: 4/4/2016 4/4/2016 SEALED BY: DEAN MARTIN L.S. 70147
AutoCAD SHX Text
EXIST. TO REMAIN
AutoCAD SHX Text
43.5%
AutoCAD SHX Text
AVERAGE GRADE AT BUILDING = (5.70'+5.68'+5.23'+5.25'+5.11'+5.37'+5.31'+5.44'+5.31'+5.40'+5.42')/11=5.38' EXISTING ELEVATION OF BUILDING ROOF AT MID-POINT = 35.60' EXISTING BUILDING HEIGHT = 35.60'-5.38'=30.22'
AutoCAD SHX Text
0
AutoCAD SHX Text
20
AutoCAD SHX Text
10
AutoCAD SHX Text
5
AutoCAD SHX Text
10
AutoCAD SHX Text
EXIST. TO REMAIN
AutoCAD SHX Text
EXIST. TO REMAIN
AutoCAD SHX Text
EXIST. TO REMAIN
AutoCAD SHX Text
EXIST. TO REMAIN
AutoCAD SHX Text
EXIST. TO REMAIN
AutoCAD SHX Text
EXIST. TO REMAIN
AutoCAD SHX Text
COASTAL JURISDICTION LINE EL.=5.1'
AutoCAD SHX Text
BUILDING SETBACK LINE
AutoCAD SHX Text
REMOVE AND DISPOSE OF AIR CONDITIONING COMPRESSOR AND PLATFORM. REFER TO ARCHITECTURAL DRAWINGS.
AutoCAD SHX Text
REMOVE AND DISPOSE OF CONCRETE SLAB UNDER MECHANICAL ROOM. REFER TO ARCHITECTURAL DRAWINGS.
MECH.ROOM
DRIVEWAYDRIVEWAY
EX'G VINYL FENCE
A/CDECK
A/C
LINE OFDECK
ABOVE
SEWER OUT
LINE OF DECK ABOVE
1
2
WATER IN
4
3
DECK
DECK
LIVING ROOM
KITCHEN
DINNINGROOM
LAUNDRY
BATH
CLOSET
UP
CLOSET
DN.
UP
LINE OF SECONDFLOOR ABOVE
LINE OF DECKABOVE
FIRE PLACE& CHIMNEY
A/C CHASE
CASEDOPENING
LINE OF OVERHANG ABOVE
CLOSET
FLOORREGISTER(TYP.)
REF.
CLOSET
CLOSET
CLOSET
BED ROOM
BED ROOM
KNEEWALL
BATH
OPEN AREABELOW
RIDGE ℄
DECK
RIDGE ℄
DN.
8'-0"
4'-0"
22'-0"
33'-0"
10'-0"
5'-0"
LINE OF ROOFOVERHANG ABOVE14" (TYP.)
A/C CHASE
CEILINGREGISTER
(TYP.)
KEY NOTES
DEMOLISH EXISTING MECHANICAL DUCT WORK, AND PIPING. COORDINATE WITH MECHANICAL, AND ELECTRICAL PLANS FOR SCOPE OF WORK.
1.
2. DEMOLISH EXISTING AIR CONDENSER, AND ITS PLATFORM.
3. DEMOLISH ALL GYPSUM BOARD, & INSULATION FROM UNDERSIDE OF HOUSE.
4. DEMOLISH EXISTING MECHANICAL CHASE, AND DUCT WORK.
NOTES:
REVISIONS
CHECKED BY:
DRAWN BY:
SHEET:
DATE:
SCALE:
DTC DRAWING FILE:
DTC PROJECT NUMBER:
FEBRUARY 2016
13-449-014
OORRAPPLICATION NO. 1405MACIAG RESIDENCE
9 DERBY AVE.MILFORD, CT
2321 Whitney Avenue - Hamden Center II - Hamden CT 06518Ph: 203 239 4200 Fax: 203 234 7376
www.teamdtc.com
1/4"=1'-0"
DEMOLITIONFLOOR PLANS
D-101RM
REM
SCALE: 1/4" = 1'-0"
GROUND FLOOR
1SCALE: 1/4" = 1'-0"
FIRST FLOOR
2
SCALE: 1/4" = 1'-0"
SECOND FLOOR
3
AutoCAD SHX Text
FOR DWG. REF.
AutoCAD SHX Text
N O R T H
DRIVEWAYDRIVEWAY
EX'G VINYLFENCE
LINE OFDECK
ABOVE
22'-0"
4'-0"
LINE OFDECK
ABOVE
1
3A-301
2
DECK
DECK
LIVING ROOM
KITCHEN
DINNINGROOM
LAUNDRY
BATH
CLOSET
UP
CLOSET
DN.
UP
LINE OF SECONDFLOOR ABOVE
LINE OF DECKABOVE
FIRE PLACE& CHIMNEY
A/C CHASE
EX'G CASEDOPENING
10" Ø COLUMN(TYP.)
LINE OF OVERHANG ABOVE
CLOSET
FLOORREGISTER(TYP.)
REF.
CLOSET
CLOSET
CLOSET
BED ROOM
BED ROOM
KNEEWALL
BATH
OPEN AREABELOW
RIDGE ℄
DECK
RIDGE ℄
DN.
33'-0"
LINE OF ROOFOVERHANG ABOVE14" (TYP.)
A/C CHASE
CEILINGREGISTER
(TYP.)
KEY NOTES
PROVIDE ENCLOSED INSULATED PIPE CHASE TO PREVENT FREEZING.COORDINATE WITH PLUMBING PLANS.
1.
2. PROVIDE NEW FOAM-IN-PLACE INSULATION, & GYPSUM WALLBOARD TOUNDERSIDE OF HOUSE.
NOTES:
REVISIONS
CHECKED BY:
DRAWN BY:
SHEET:
DATE:
SCALE:
DTC DRAWING FILE:
DTC PROJECT NUMBER:
FEBRUARY 2016
13-449-014
OORRAPPLICATION NO. 1405MACIAG RESIDENCE
9 DERBY AVE.MILFORD, CT
2321 Whitney Avenue - Hamden Center II - Hamden CT 06518Ph: 203 239 4200 Fax: 203 234 7376
www.teamdtc.com
1/4"=1'-0"
FLOOR PLANS
A-101RM
REM
SCALE: 1/4" = 1'-0"
GROUND FLOOR
1
SCALE: 1/4" = 1'-0"
FIRST FLOOR
2
SCALE: 1/4" = 1'-0"
SECOND FLOOR
3
LINE OF NEW DUCT CHASE ABOVE SEE 5/A301
AutoCAD SHX Text
FOR DWG. REF.
AutoCAD SHX Text
N O R T H
1
2
3
2
1
1 2
KEY NOTES
1. MECH. ROOM TO BE RETAINED. REPLACE DAMAGED SISING AND DOOR.
2. EXISTING A/C AND PLATFORM TO BE DEMOLISHED.
REPLACE PATCH OR REPAIR ANY DAMAGED OR DISPLACED SIDING FROMSTORM DAMAGE, TYP.
3.
NOTES:
REVISIONS
CHECKED BY:
DRAWN BY:
SHEET:
DATE:
SCALE:
DTC DRAWING FILE:
DTC PROJECT NUMBER:
FEBRUARY 2016
13-449-014
OORRAPPLICATION NO. 1405MACIAG RESIDENCE
9 DERBY AVE.MILFORD, CT
2321 Whitney Avenue - Hamden Center II - Hamden CT 06518Ph: 203 239 4200 Fax: 203 234 7376
1. THE CONTRACTOR SHALL BECOME THOROUGHLY FAMILIAR WITH THE PROJECT DOCUMENTS OF ALL TRADES.THE DRAWINGS ARE DIAGRAMMATIC AND SHOW THE GENERAL ARRANGEMENT OF EQUIPMENT AND PIPING.THE CONTRACTOR SHALL COORDINATE THE EXACT LOCATION OF EQUIPMENT AND PIPING INSTALLATION WITHALL TRADES BEFORE COMMENCING WORK.
2. THIS CONTRACT SHALL INCLUDE ALL THE NECESSARY PIPING, FITTINGS, TRANSITIONS ETC. AS NECESSARY TOINSTALL PLUMBING SYSTEM, AND TO AVOID ANY CONFLICTS WITH OTHER TRADES AND THE BUILDINGSTRUCTURE.
3. IT IS NOT THE INTENT OF THE DRAWINGS TO SHOW INDIVIDUAL BRANCH PIPING TO EACH PLUMBING FIXTURE;ONLY THE BRANCH PIPING TO GROUPS OF FIXTURES IS INDICATED. THE ENTIRE PLUMBING SYSTEM SHALL BEFULLY OPERATIONAL AND READY FOR BENEFICIAL USE BEFORE THE JOB IS CONSIDERED COMPLETE.
4. REFER TO LATEST ARCHITECTURAL PLANS FOR ELEVATIONS, SECTIONS, DETAILS, MOUNTING HEIGHTS,LOCATION OF PLUMBING FIXTURES.
5. DO NOT SCALE DRAWINGS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS & CONDITIONS IN THE FIELD ANDSHALL NOTIFY THE ENGINEER IMMEDIATELY OF ANY & ALL DISCREPANCIES.
6. IT IS NOT INTENDED THAT THE DRAWINGS SHOW EVERY PIPE, FITTING, RISE/DROP OR DETAIL. SYSTEM &COMPONENTS SHALL BE INSTALLED ACCORDING TO THE INTENT AND MEANING OF CONTRACT DOCUMENTSAND IN ACCORDANCE WITH GOOD PRACTICE.
7. CONTRACTOR IS RESPONSIBLE TO PROVIDE COMPLETE AND OPERATIONAL SYSTEMS WITH FACILITIES ANDSERVICES TO MEET REQUIREMENTS INDICATED AND IN ACCORDANCE WITH APPLICABLE CODES ANDORDINANCES.
8. EQUIPMENT AND COMPONENTS HAVING EQUAL PERFORMANCE CHARACTERISTICS BY OTHERMANUFACTURERS MAY BE CONSIDERED, PROVIDED DEVIATIONS IN DIMENSIONS, OPERATION AND OTHERCHARACTERISTICS DO NOT CHANGE DESIGN CONCEPT OR INTENDED PERFORMANCE AS JUDGED BY THEENGINEER. BURDEN OF PROOF OF EQUALITY OF PRODUCTS IS ON THE CONTRACTOR.
9. CONTRACTOR IS RESPONSIBLE FOR THE SAFEKEEPING OF HIS OWN PROPERTY ON THE JOB SITE. OWNERASSUMES NO RESPONSIBILITY FOR THE PROTECTION OF PROPERTIES AGAINST FIRE, THEFT ANDENVIRONMENTAL CONDITIONS.
10.CONTRACTOR IS RESPONSIBLE FOR PROPERLY PROTECTING OWNER'S PROPERTY AND EQUIPMENT FROMINJURY, AND DAMAGE TO SAME SHALL BE REPLACED BY CONTRACTOR.
11.CONTRACTOR IS TO CLEAN JOB SITE DAILY AND REMOVE FROM THE PREMISES ANY DIRT AND DEBRIS CAUSEDBY THE PERFORMANCE OF THE WORK INCLUDED IN THIS CONTRACT.
12.ALL WORK TO BE PERFORMED IN A CLEAN AND WORKMANLIKE MANNER, CARE SHALL BE EXERCISED TOMINIMIZE ANY INCONVENIENCE OR DISTURBANCE TO OTHER AREAS OF THE BUILDING WHICH ARE TO REMAININ OPERATION. ISOLATE CONSTRUCTION AREAS BY MEANS OF TEMPORARY PARTITIONS AND/OR TARPS TOKEEP DUST AND DIRT WITHIN WORK AREA.
13.CONTRACTOR IS RESPONSIBLE TO PROPERLY SECURE AREAS OF CONSTRUCTION AT THE END OF EACHWORKING DAY.
14.EQUIPMENT AND PIPING TO BE INSTALLED IN ACCORDANCE WITH SEISMIC REQUIREMENTS OF THEINTERNATIONAL BUILDING CODE.
15.CONTRACTOR IS RESPONSIBLE TO COORDINATE WITH ALL OTHER TRADES.16.ALL EQUIPMENT SUPPORTS AND PIPE HANGERS TO BE CONNECTED FROM THE BUILDING STRUCTURE.17.PROVIDE ACCESS PANELS/DOORS FOR ALL CONCEALED PLUMBING ITEMS REQUIRING ACCESS, COORDINATE
WITH DIVISION 8.18.PROVIDE SHUTOFF VALVES AT ALL BRANCH PIPING TAKEOFFS.19.ALL BRANCH WATER PIPES TO HAVE STOP VALVES AT EACH PLUMBING FIXTURE.20.INSULATE COLD WATER, HOT WATER AND RECIRCULATION PIPING, CONDENSATE DRAIN, STORM PIPING AND
ROOF DRAIN BODIES.21.EVERY FIXTURE SHALL BE PROPERLY PIPED TO WATER, SANITARY, WASTE, AND VENT SYSTEMS. REFER TO
THE PLUMBING SCHEDULES ON MEP DRAWINGS FOR INDIVIDUAL PIPE SIZES TO EACH FIXTURE.22.WHERE AN INACCESSIBLE CEILING IS INSTALLED (GYP BOARD OR EQUIVALENT), THE CONTRACTOR SHALL
COORDINATE THE LOCATIONS OF ACCESS PANELS FOR ALL VALVES, CLEANOUTS, ETC., REQUIRING ACCESS,WITH THE ARCHITECT, PRIOR TO INSTALLATION OF SUCH DEVICES AND OTHER APPURTENANCES.
23.NO PIPING SHALL BE INSTALLED WITHIN STAIRS, STAIR WALLS, OR OVER ELECTRICAL PANELS/EQUIPMENT.ONLY DEDICATED PLUMBING PIPING WILL BE ALLOWED WITHIN EACH OF THE SPACES INDICATED ABOVE.COORDINATE THE LOCATION OF ALL PIPING WITH ALL OTHER TRADES, AND ADJUST AS NECESSARY
24.ALL PIPING IS TO BE RUN CONCEALED IN CEILINGS OR WALLS. PIPING IS TO BE EXPOSED ONLY WHERE NOTEDON DRAWINGS. IF CONTRACTOR CANNOT RUN PIPING CONCEALED, NOTIFY ENGINEER IMMEDIATELY TORESOLVE CONFLICT.
25.PIPE ALL CONDENSATE DRAINS FROM MECHANICAL EQUIPMENT COOLING COILS, BY GRAVITY (INTERIOR AIRHANDLING UNITS, FAN COIL UNITS, ETC.) THROUGH AN AIR GAP. EACH CONDENSATE DRAIN SHALL BE TRAPPEDAT THE EQUIPMENT DRAIN OUTLET, REFER TO TRAP DETAILS ON DRAWINGS. COORDINATE EXACT LOCATIONWITH THE HVAC CONTRACTOR AND ADJUST AS NECESSARY.
26.COORDINATE EXACT LOCATION OF ALL UNDERGROUND UTILITIES (WATER, GAS, SANITARY, ETC.) EXITING ORENTERING THE BUILDING WITH CIVIL DRAWINGS.
27.DOMESTIC WATER DROPS OR RISERS INSTALLED IN EXTERIOR WALLS, SHALL BE INSTALLED ON THE WARMSIDE OF THE BUILDING INSULATION, AND THE LOCATION SHALL BE MADE INFILTRATION FREE.
28.COORDINATE ALL PLUMBING EQUIPMENT REQUIRING POWER, FOR EXACT LOCATION AND POWERREQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
29.ALL INDIRECT WASTE DRAINS SHALL BE PIPED TO FLOOR DRAINS, FUNNELS OR FIXED AIR GAP FITTINGS,THROUGH AIR GAP OR TO A SINK DRAIN TAILPIECE.
30.CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ELBOWS, TEES, DROPS, AND MISCELLANEOUS PIPING DUE TOELEVATION CHANGES, OBSTRUCTIONS, COORDINATION WITH OTHER TRADES, ETC. TO INSTALL A COMPLETE,FUNCTIONING, PLUMBING SYSTEM.
LEGEND
GAS PIPING G
V
PIPING DIRECTION OF FLOW
PIPING RISER UP
PIPING RISER DOWN
DRAIN
DESCRIPTION
SOIL OR WASTE ABOVE FLOOR OR GRADE
SOIL OR WASTE BELOW FLOOR OR GRADE
COLD WATER PIPING
VENT PIPING
CHECK VALVE
BALL VALVE
TRAP
UNION
CAP ON END OF PIPE
SAN
SAN
SYMBOL
POINT OF CONNECTION
POINT OF DISCONNECT
HT - HEAT TRACED & INSULATED PIPE
GAS COCK
GAS PRESSURE REGULATOR
GAS SOLENOID VALVES
1. NOTES BELOW ARE NOT INTENDED TO REPLACE SPECIFICATIONS. SEE SPECIFICATIONS FOR REQUIREMENTS IN ADDITION TOGENERAL NOTES.
2. CONTRACTOR SHALL VISIT THE SITE AND BECOME INFORMED AS TO THE NATURE AND SCOPE OF WORK REQUIRED BYCONTRACT DOCUMENTS PRIOR TO BIDDING PROJECT.
3. PROVIDE ALL REQUIRED MATERIALS, LABOR, EQUIPMENT, AND SERVICES NECESSARY FOR THE INSTALLATION OF THE WORK ASSHOWN ON THESE DRAWINGS OR SPECIFIED BY THE BASE BUILDING DRAWING AND SPECIFICATIONS.
4. REFER TO AND CAREFULLY CHECK ARCHITECTURAL, ELECTRICAL, AND PLUMBING DRAWINGS AND DETAILS, NOTES, LOCATIONSWHERE WALLS, PARTITIONS, CEILINGS, AND OTHER SURFACES ARE FURRED, LOCATIONS OF SHAFTS, SOFFITS, AND CONFLICTSWITH WORK OF OTHER TRADES, AND ARRANGE WORK ACCORDINGLY. FURNISH ALL OFFSETS, DAMPERS, CONNECTORS, ETC.,REQUIRED TO MEET SUCH CONDITIONS.
5. DUE TO SCALE OF DRAWINGS, ALL REQUIRED OFFSETS, DAMPERS, ETC., MAY NOT BE INDICATED.6. COORDINATE DIFFUSER AND REGISTER LOCATIONS AND DUCT WITH LIGHTING FIXTURES AND STRUCTURE. SEE
ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR DETAILS.7. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS AND ARRANGE FOR ALL REQUIRED INSPECTIONS IN
ACCORDANCE WITH STATE AND LOCAL GOVERNING CODES.8. THE TERM "PROVIDE" SHALL MEAN "TO FURNISH, INSTALL, AND CONNECT COMPLETELY".9. TURN OVER TO THE OWNER ALL MANUFACTURER'S WARRANTIES FOR EQUIPMENT AND MATERIALS PROVIDED.10. WHERE THE CONTRACTOR PROPOSES TO USE AN ITEM OF EQUIPMENT OTHER THAN THAT SPECIFIED OR DETAILED ON THE
DRAWINGS WHICH REQUIRES ANY REDESIGN OF THE STRUCTURE, PARTITIONS, FOUNDATIONS, PIPING, WIRING OR ANY OTHERPART OF THE MECHANICAL, ELECTRICAL OR ARCHITECTURAL LAYOUT, ALL SUCH REDESIGN AND ALL NEW DRAWINGS ANDDETAILING REQUIRED THEREFORE, SHALL BE PREPARED AT THE CONTRACTOR'S EXPENSE AND ARE SUBJECT TO THE REVIEWAND APPROVAL OF THE OWNER OR HIS AUTHORIZED REPRESENTATIVE. OWNER RESERVES THE RIGHT TO HAVE THEARCHITECT OR ENGINEER OF HIS CHOICE PREPARE ANY REDESIGN WORK.
11. CONTRACTOR SHALL COORDINATE ELECTRICAL REQUIREMENTS OF MECHANICAL EQUIPMENT WITH DIVISION 26.12. ALL WORK SHALL BE DONE WITH LICENSED WORKMEN IN ACCORDANCE WITH STATE AND LOCAL GOVERNING AUTHORITIES.13. BEFORE SELECTING MATERIAL AND EQUIPMENT, AND PROCESSING THE WORK, INSPECT AREAS WHERE MATERIAL AND
EQUIPMENT ARE TO BE INSTALLED TO INSURE SUITABILITY AND CHECK NEEDED SPACE FOR PLACEMENT AND CLEARANCES.14. BEFORE CUTTING AND DRILLING INTO BUILDING ELEMENTS, INSPECT AND LAYOUT WORK TO AVOID DAMAGING STRUCTURAL
ELEMENTS AND BUILDING UTILITIES.15. CONTRACTOR RESPONSIBLE FOR REPAIR AND PAYMENT FOR ALL UTILITIES DAMAGE DURING CONSTRUCTION.16. CONTRACTOR TO CONFIRM DUCTWORK LOCATIONS, ELEVATIONS AND SIZES BEFORE ANY WORK IS STARTED. IF ANY
DISCREPANCIES ARE FOUNDED, NOTIFY ENGINEER BEFORE PROCEEDING WITH WORK. FOLLOW MANUFACTURER'SRECOMMENDATIONS FOR INSTALLATION OF PROVIDED EQUIPMENT.
17. ALL SHOP DRAWINGS OF INDIVIDUAL COMPONENTS ARE TO BE SUBMITTED AS A COMPLETE PACKAGE.18. HVAC DRAWINGS DO NOT NECESSARY SHOW ALL CONDITIONS OF BUILDING. CONTRACTOR TO USE ALL DRAWINGS AND
SPECIFICATIONS OF CONTRACT DOCUMENTS AND INSPECTION OF FIELD CONDITIONS FOR DIVISION 23.19. HVAC PLANS, DETAILS AND ONE LINE DIAGRAMS SHOW THE GENERAL LOCATION AND ARRANGEMENT OF THE SYSTEM. THESE
ARE DIAGRAMMATIC AND DO NOT SHOW ALL OFFSETS, HANGERS, ACCESS DOORS, ETC. WHICH THE CONTRACTOR MUSTPROVIDE TO COMPLETE THE SYSTEM.
20. ALL WORK IN INTERIOR FINISHED SPACES EXCEPT INDICATED IS TO BE CONCEALED ABOVE CEILING. PROVIDE ALL NECESSARYCUTTING, PATCHING, REPAINTING AND/OR REPLACEMENT OF FINISHES AS REQUIRED TO PERFORM COORDINATE WITH OTHERDIVISIONS.
21. IF MANUFACTURER OF EQUIPMENT REQUIRES LARGER CAPACITY CIRCUITRY AND/OR EQUIPMENT THE CONTRACTOR SHALLPROVIDE SUCH CAPACITY AND/OR EQUIPMENT UNDER THIS CONTRACT AT NO COST TO THE OWNER.
22. SUPPORT DUCTWORK ABOVE CEILING FROM CONSTRUCTION ABOVE AS CLOSE AS POSSIBLE TO BOTTOM OF SLABS, BEAMS,MAINTAINING HEADROOM AT ALL TIMES.
23. DO NOT SCALE DRAWINGS. CHECK EXISTING SPACE CONDITIONS AT THE JOB SITE.24. GENERAL CONTRACTOR PROVIDE ALL CONTROL DEVICES, EQUIPMENT, ACCESSORIES, VFD DRIVES, OTHER APPARATUS,
CONTROL VALVES AND DAMPERS, ACTUATORS, SENSORS, ETC. AND ALL CONTROL WIRING.25. ALL DUCTWORK SHALL BE HUNG FROM STRUCTURE ABOVE.26. PROVIDE FLEXIBLE CONNECTIONS BETWEEN MECHANICAL EQUIPMENT AND DUCTWORK AND PIPING.27. PROVIDE MINIMUM OF 3' DUCT LINER ON SUPPLY AND RETURN BRANCH DUCT UNIT CONNECTION (SEE DETAILS).28. PROVIDE VOLUME DAMPERS ON ALL BRANCHES OF DUCTWORK (SUPPLY, RETURN, EXHAUST).29. ALL PENETRATIONS THRU WALLS, ROOF, AND FLOORS TO BE COORDINATED BEFORE SITE WORK EXECUTION WITH
STRUCTURAL ENGINEERS.30. THERMOSTAT AND TEMPERATURE SENSOR LOCATIONS TO BE COORDINATED WITH INTERIOR WALL LAYOUT.31. CONTRACTOR SHALL SELECT AND PROVIDE EXPANSION JOINTS OR EXPANSION LOOPS AND ANCHORS AS REQUIRED TO
PREVENT TEMPERATURE EXPANSION STRESSES OF HYDRONIC PIPES BASED ON ACTUAL INSTALLATION/CONDITIONS.32. ELECTRICAL CHARACTERISTICS FOR MECHANICAL EQUIPMENT: EQUIPMENT OF HIGHER ELECTRICAL CHARACTERISTICS MAY BE
FURNISHED PROVIDED SUCH PROPOSED EQUIPMENT IS APPROVED IN WRITING AND CONNECTING ELECTRICAL SERVICES,CIRCUIT BREAKERS, AND CONDUIT SIZES ARE APPROPRIATELY MODIFIED. IF MINIMUM ENERGY RATINGS OR EFFICIENCIES ARESPECIFIED, EQUIPMENT SHALL COMPLY WITH REQUIREMENTS.
33. SHOP DRAWINGS: DETAIL MAJOR ELEMENTS, COMPONENTS, AND MECHANICAL EQUIPMENT AND MATERIALS IN RELATIONSHIPSWITH OTHER SYSTEMS, INSTALLATIONS, AND BUILDING COMPONENTS. SHOW SPACE REQUIREMENTS FOR INSTALLATION ANDACCESS. INDICATE IF SEQUENCE AND COORDINATION ARE IMPORTANT TO EFFICIENT FLOW OF THE WORK. INCLUDE THEFOLLOWING.
A. PLANNED PIPING LAYOUT, INCLUDING VALVE AND SPECIALTY LOCATIONS AND VALVE-STEM MOVEMENT.B. CLEARANCES FOR INSTALLING AND MAINTAINING INSULATION.C. CLEARANCES FOR SERVING AND MAINTAINING EQUIPMENT, ACCESSORIES, AND SPECIALTIES, INCLUDING SPACE FOR
DISASSEMBLY REQUIRED BY PERIODIC MAINTENANCE.D. EQUIPMENT AND ACCESSORY SERVICE CONNECTIONS AND SUPPORT DETAILS.E. EXTERIOR WALL AND FOUNDATION PENETRATIONS.F. SIZES AND LOCATION OF REQUIRED CONCRETE PADS AND BASES.G. FLOOR PLANS, ELEVATIONS, AND DETAILS TO INDICATE PENETRATIONS, FLOORS, WALLS, AND CEILINGS AND THEIR
RELATIONSHIP TO OTHER PENETRATIONS AND INSTALLATIONS.H. SCALE: MINIMUM 1/4"=1'-0" FOR FLOOR PLAN, 3/8"=1'-0" FOR MECHANICAL ROOMS.
HVAC GENERAL NOTES
DOMESTIC HOT WATER PIPING
PRESSURE REDUCING VALVE
D
FUEL OIL PIPING O
THERMOSTATIC MIXING VALVE
CLEANOUT/ WALL CLEANOUT
ABBREVIATIONSAAV AIR ADMITTANCE VALVECO CLEANOUTCTE CONNECT TO EXISTINGCW COLD WATERE EXISTING TO REMAINER EXISTING TO BE REMOVEDERR EXISTING TO BE RELOCATEDHB HOSE BIBBHW HOT WATERHZ HERTZIN INCHIM ICE MAKERKS KITCHEN SINKG GASGPM GALLONS PER MINUTELAV LAVATORYMAX MAXIMUMMIN MINIMUMN NEWPH PHASEPRV PRESSURE REDUCING VALVESH SHOWERTEMP TEMPERATURETMV THERMOSTATIC MIXING VALVETYP TYPICALVTR VENT THROUGH ROOFW WASTEWC WATER CLOSETWCO WALL CLEANOUTWM WASHING MACHINE
HOSE BIBB
RCN
RWF1/4=1.0
MP-001
MECHANICAL &PLUMBING GENERAL
NOTES
NOTES:
REVISIONS
CHECKED BY:
DRAWN BY:
SHEET:
DATE:
SCALE:
DTC DRAWING FILE:
DTC PROJECT NUMBER:
04/22/2016
13-449-014
OORRAPPLICATION NO. 1405MACIAG RESIDENCE
9 DERBY AVE.MILFORD, CT
2321 Whitney Avenue - Hamden Center II - Hamden CT 06518Ph: 203 239 4200 Fax: 203 234 7376
www.teamdtc.com
GENERAL NOTE:INSULATE AND HEAT TRACE ALLWATER AND SANITARY LINESLOCATED BELOW FIRST FLOOR.
MAIN SAN DN
MAIN WATER DN
SWS-175 CFM
SWS-1200 CFM
SWS-1175 CFM
SWS-1175 CFM
SWS-1125 CFM
SWS-1125 CFM
12x12 SA UP
10x814x816x8
WALL CAP TERMINATIONINCLUDE BIRDSCREEN
AND BACK DRAFT DAMPER
6"Ø SA UP
EF-175 CFM
RLL/RSL UP
CU-1
6"Ø to 12x6 TRANSITION
10x10
6"Ø
12x10 SA
1/4"=1'-0"
MECHANICALFLOOR PLANS
M-100RCN
RWF
GROUND FLOOR PLANM-100
1
SCALE: 1/4" = 1"-0"
FIRST FLOOR PLANM-100
2
SCALE: 1/4" = 1"-0"
NOTES:
REVISIONS
CHECKED BY:
DRAWN BY:
SHEET:
DATE:
SCALE:
DTC DRAWING FILE:
DTC PROJECT NUMBER:
04/22/2016
13-449-014
OORRAPPLICATION NO. 1405MACIAG RESIDENCE
9 DERBY AVE.MILFORD, CT
2321 Whitney Avenue - Hamden Center II - Hamden CT 06518Ph: 203 239 4200 Fax: 203 234 7376
www.teamdtc.com
DUCT CHASE SEE 5/A301
AutoCAD SHX Text
FOR DWG. REF.
AutoCAD SHX Text
N O R T H
CDS-1175 CFM CDS-1
100 CFM
CDS-175 CFM
CDS-150 CFM
CDS-1125 CFM
12x12 SA UP & DN
6"Ø SA UP
CDR-11400 CFM
RLL/RSL UP & DN
WALL CAP TERMINATIONINCLUDE BIRDSCREEN
AND BACK DRAFT DAMPER
EF-175 CFM
6"Ø
12x12 SA DN
6"Ø SA DN
DX COIL
14x1
2
6"Ø
12x6
12x6
12x6
12x6
12x6
16x1
4
16x14
14x1
4
14x14 14x14
RLL/RSL DN
GENERAL NOTE:1. CONTRACTOR TO CONFIRM F-1 MODEL WITH
ENGINEER PRIOR TO PURCHASING ORINSTALLING CU-1 AND DX COIL.
2. FOLLOW MANUFACTURER'S GUIDELINES FORINSTALLING RLL/RSL LINES AND DO NOTEXCEED RECOMMENDED EQUIVALENT LENGTH
3. RECONNECT EXISTING THERMOSTAT TO F-1.REPLACE EXISTING THERMOSTAT IF REQUIREDFOR PROPER OPERATION.
12x6 DN (TYP)
2"Ø PVC VENT AND INTAKEWITH CONCENTRIC VENT
TERMINATION, REFERTO DETAILS
2"Ø
2"Ø
F-1
F-1 EXISTING FURNACE TO BERELOCATED FROM GROUNDLEVEL TO ATTIC WITH NEWDX COIL
1/4"=1'-0"
MECHANICALFLOOR PLANS
M-101JV
RWF
SECOND FLOOR PLANM-101
1
SCALE: 1/4" = 1"-0"
ATTIC FLOOR PLANM-101
2
SCALE: 1/4" = 1"-0"
NOTES:
REVISIONS
CHECKED BY:
DRAWN BY:
SHEET:
DATE:
SCALE:
DTC DRAWING FILE:
DTC PROJECT NUMBER:
04/22/2016
13-449-014
OORRAPPLICATION NO. 1405MACIAG RESIDENCE
9 DERBY AVE.MILFORD, CT
2321 Whitney Avenue - Hamden Center II - Hamden CT 06518Ph: 203 239 4200 Fax: 203 234 7376
www.teamdtc.com
AutoCAD SHX Text
FOR DWG. REF.
AutoCAD SHX Text
N O R T H
NOT TO SCALEMP3003
PROVIDE NON-CORROSIVE METALPIPE STRAPS TO FASTEN VERTICAL
PIPE RISER TO FOUNDATIONCOLUMNS. STRAPS SHALL BE
CAPABLE OF WITHSTANDINGHYDROSTATIC AND HYDRODYNAMIC
LOADS AND STRESSES.
MP3006
NOT TO SCALE
ESCUTCHEON PLATE ON ONE OR BOTH SIDES WHEREPIPING IS EXPOSED(TYPICAL)
WITH CONTINUOUS FLANGE ALLAROUND BOTH SIDES (TYPICAL)
PIPE
STUD WALL
NEW OR EXISTINGDRYWALLCONSTRUCTIONANCHOR SLEEVE TOWALL (TYPICAL)
X = WIDTH OF LARGER BRANCH DUCTY = WIDTH OF SMALLER BRANCH DUCTD = WIDTH MAIN DUCTD = DEPTH OF BRANCH DUCTS AND MAIN DUCT
Y x DX x D
W x D
Y
X
A x DA x D
.5W
.5W
W x D
A = WIDTH OF BRANCH DUCTSW = WIDTH MAIN DUCTD = DEPTH OF BRANCH DUCTS AND MAIN DUCT
LOW PRESSURE UNEQUAL SPLIT TEE
LOW PRESSURE EQUAL SPLIT TEE
MP3007
NOT TO SCALE
TURNING VANEVANED ELBOW
FRAMELOCKING LUG
3 1/
2"2
1/4"
412" R
214" R
NOTES:1. LOCKING LUGS INTEGRAL WITH VANE2. MAXIMUM UNSUPPORTED VANE LENGTH 48"3. FRAMES BOLTED OR RIVETED TO ELBOW4. VANES AND FRAMES, SAME GAUGE AS ELBOW5. PROVIDE TURNING VANES FOR SQUARE AND
RECTANGULAR ELBOWS.
MP3008
NOT TO SCALE
DUCT
DUCT HELD ONSUPPORT BY SELFTAPPING SCREWS
MINIMUM 1" USE 2"FOR DUCTS 48" WIDE
AND OVER
DUCT SUPPORT TO CONFORM TOAISC OR AISI DESIGN USE 1"x1
16"FLAT STEEL BAR FOR DUCT 2 SQ.FT. OR LESS. 1"x1
8" FLAT STEELBAR FOR DUCT OVER 2 SQ. FT.AREA.
DUCT 4 SQ. FT. OR LESS HUNG 8'-0" OCDUCT 4 SQ. FT. TO 100 HUNG 6'-0" OCDUCT OVER 10 SQ FT. HUNG 4'-0" OC
MP3009
NOT TO SCALE
INSULATION (WHEREREQUIRED)
OPPOSED BLADE DAMPER,INSTALL AS PER DIFFUSERMANUFACTURER'SRECOMMENDATIONS.
WALL
SUPPLY AIR DUCT
SHEET METAL SUPPLY AIR PLENUM.FULL SIZE OF DIFFUSER COLLAR.
DIFFUSER, GRILLE, AND REGISTER SCHEDULE REMARKS:NOTE 1. PROVIDE OPPOSED BLADE DAMPER
DIFFUSER, GRILLE, AND REGISTER SCHEDULE GENERAL COMMENTS:1. DIFFUSER, REGISTER, GRILLE, OPPOSE BLADE DAMPER AND ASSOCIATED FRAME SHALL BE SOLID ALUMINUM OR STEEL CONSTRUCTION.2. COLOR BY ARCHITECT3. REFER TO ARCHITECTURAL DRAWINGS FOR WALL/CEILING TYPE. PROVIDE MOUNTING ACCESSORIES AS REQUIRED FOR CEILING APPLICATION4. APPROXIMATE FACE SIZE NOTED. REFER TO SPECIFIC BORDER / FRAME TYPE FOR ACTUAL FACE SIZE
MARK MANUFACTURER MODEL CFM SP WATTS REMARKS
EF-1 BROAN XB-80L 80 .1" w.c. 6.0 INTERLOCK WITH BATHROOM LIGHT SWITCH, PROVIDE BACKDRAFT DAMPER ANDMANUFACTURER'S WALL CAP TERMINATION KIT
NOTES: CONSTANT 20 CFM SWITCH TO MAXIMUM CFM.
SIDEWALLGRILLE
INSULATION (WHEREREQUIRED)
OPPOSED BLADE DAMPER,INSTALL AS PER DIFFUSERMANUFACTURER'SRECOMMENDATIONS.
CEILING
SUPPLY AIR DUCT
DIFFUSER
SHEET METAL SUPPLY AIR PLENUM.FULL SIZE OF DIFFUSER COLLAR.
AMPERES ALTERNATING CURRENT (60 HZ) AUTHORITY HAVING JURISDICTION AMERICAN WIRE GAUGE CONDUIT COPPER DRAWING EXISTING TO REMAIN GROUND-FAULT CIRCUIT-INTERRUPTER KILOVOLT AMPERE NATIONAL ELECTRIC CODE NATIONAL ELECTRICAL CONTRACTORS ASSOC. NATIONAL ELECTRICAL MANUFACTURERS ASSOC. NONMETALLIC SHEATHED NOT TO SCALE POLE SMOKE UNDERWRITER'S LABORATORY UNLESS OTHERWISE NOTED VOLTS VOLT-AMPERES WAITS WEATHERPROOF NUMBER FEET INCHES
MEASUREMENTS SHOWN ARE TO THE CLOSEST EDGE OF THE DETECTOR
FINISHED FLOOR
i I � j -�-1-'----��������-----::,...�
ACCEPTED HERE � NEVER MOUNT HERE --:::::"'.:I
I WALL MOUNTED ====--------SMOKE DETECTOR
•
FINISHED-WALL
I
SIDE WALL
ELECTRICAL GENERAL NOTES 1. UNLESS OTHERWISE INDICATED, FURNISH AND INSTALL A COMPLETE AND OPERATIONAL
ELECTRICAL SYSTEM INCLUDING ALL NECESSARY MATERIAL, LABOR, AND EQUIPMENT.
2. ELECTRICAL PLANS AND DETAILS, AND ONE LINE DIAGRAMS SHOW THE GENERAL LOCATION ANDARRANGEMENT OF THE ELECTRICAL SYSTEM. THEY ARE DIAGRAMMATIC AND DO NOT SHOW ALLCONDUIT BODIES, CONNECTORS, BENDS, FITTINGS, HANGERS, AND ADDITIONAL PULL ANDJUNCTION BOXES WHICH THE CONTRACTOR MUST PROVIDE TO COMPLETE THE ELECTRICALSYSTEM.
3. FURNISH AND INSTALL A TEMPORARY ELECTRICAL SERVICE FOR ELECTRICAL POWER DURINGCONSTRUCTION.
4. ALL EQUIPMENT AND MATERIAL SHALL BE LABELED AND LISTED, AND INSTALLED IN ACCORDANCEWITH THEIR LISTING.
5. THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND ARRANGE FOR ALL REQUIREDINSPECTIONS IN ACCORDANCE WITH STATE GOVERNING AUTHORITIES.
6. ALL WORK SHALL BE DONE WITH LICENSED WORKMEN IN ACCORDANCE WITH STATE GOVERNINGAUTHORITIES.
7. THE DEFINITION OF ELECTRICAL TERMS USED SHALL BE AS DEFINED IN THE 2011 EDITION OF THENATIONAL ELECTRIC CODE (NEC).
8. THE TERM "INDICATED" SHALL MEAN "AS SHOWN ON CONTRACT DOCUMENTS (SPECIFICATIONS,DRAWINGS, AND RELATED ATTACHMENTS)".
9. THE TERM "SIZE" SHALL MEAN ONE OR MORE OF THE FOLLOWING: "LENGTH, CURRENT ANDVOLTAGE RATING, NUMBER OF POLES, NEMA SIZE, AND OTHER SIMILAR ELECTRICALCHARACTERISTICS".
10. ELECTRICAL PLANS AND DETAILS DO NOT SHOW ALL INTERFERENCE'S AND CONDITIONS, VISIBLEAND/OR HIDDEN, THAT MAY EXIST; THUS REQUIRING THE CONTRACTOR TO INSPECT AND SURVEYTHE SPACE BEFORE PERFORMING THE WORK.
11. COORDINATE ELECTRICAL WORK WITH OWNER.
12. COORDINATE ELECTRICAL WORK WITH OTHER DIVISIONS OF THIS PROJECT.
13. BEFORE SELECTING MATERIAL AND EQUIPMENT, AND PROCEEDING WITH WORK, INSPECT AREASWHERE MATERIAL AND EQUIPMENT ARE TO BE INSTALLED TO INSURE SUITABILITY, AND CHECKNEEDED SPACE FOR PLACEMENT, CLEARANCES AND INTERCONNECTIONS.
14. BEFORE CUTTING OR DRILLING INTO BUILDING ELEMENTS INSPECT AND LAYOUT WORK TO AVOIDDAMAGING STRUCTURAL ELEMENTS AND BUILDING UTILITIES.
15. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (NEC)ANSI/NFPA 70 2011 EDITION.
16. TYPICAL MOUNTING HEIGHTS OF DEVICES SHALL COMPLY NECA 1-2010.
17. PENETRATIONS THROUGH GROUND SLAB SHALL BE SEALED WITH POLYURETHANE SEALANTTYPICAL FOR ALL PENETRATIONS.
18. FURNISH AND INSTALL MEANS OF DISCONNECTION FOR ALL MOTORIZED EQUIPMENT ANDAPPLIANCES IN ACCORDANCE WITH NEC.