8/10/2019 Delixi Catalogue 2009
1/112
Low Voltage Electrical Appliance
Right Quality, Right Price
International Catalogue 2009
8/10/2019 Delixi Catalogue 2009
2/112
A global company at your service
Delixi was founded in 1984 in Zhejiang province with sales
over 1,5BM, employing more than 15000 people.
Delixi created an international Joint Venture in November
2007,named Delixi Electric LTD,in order to serve you
worldwide,with core LV products having the right qualityat the right price.
Our products are designed for Residential / Building /
Energy / infrastructure and Industrial markets . Delixi
Electric employs 5200 people world wide.
A reliable company serving you with
reliable product
Delixi Electric: Who are we
Dedicated R&D center
International quality control of suppliers
International quality control of plants
Fully automatized distribution center
Clear warranty policy
Network of recognized 600 distributors
world wide
8/10/2019 Delixi Catalogue 2009
3/112
Reliable quality
Delixi Electric Ltd provides up to 18 months warranty against any defects inconstruction arising from faulty designs, material or workmanship.
For more details, please contact your local Delixi Electric Company.
8/10/2019 Delixi Catalogue 2009
4/112
Delixi Electric Pakistan73 / B / 3 , Race View,Jail Road,Lahore, 54000,PakistanTel: 0092 - 42 - 7570412 / 7570443 ,
extension 100/103Fax: 0092 - 42 - 7570443 , extension 108Contact: Syed Sohail IDREESMobile: 0092 [email protected]
Delixi Elecric Southern AfricaCanon Crescan Drive , RoodekopGermiston, 1400PO Box 13151 , Elspark, 1418Mobile: +27 (0) 836438898www.delixi-electric.co.zaContact: Vicky [email protected]
Delixi Electric Middle-EastRAK Free trade zonePO BOX 10559Ras El KhaimaUnited Arab Emirates
Tel: +971 ( 7 ) 244 47 27Fax: + 971 ( 7 ) 244 27 [email protected]: Raja BHAUMIKMobile: +971 ( 50 ) 657 [email protected]
Delixi Electric Marocco213 Centre YousraRond-point dEuropeCasablanca, Maroctel: +212 (0) 22 268 161Fax: +212 (0) 22 491342Contact: Hicham MOUKIMobile: +212 (0) 61 100 [email protected]
Delixi Electric South East Europe20 Tsar Samuil str . , 1rst FloorTriaditsa MunicipalitySofiaBulgariaContact: Doychin ZAHARINOVMobile: +359 885 750 [email protected]
A company to serve you where you are
We set up companies in many countries in order to deliver best in classlocal availability and support .
Delixi Elecric ChinaDelixi Liushi Industrial Park,Yueqing,Zhejiang,P.R.ChinaPost Code:325604http://english.delixi-electric.com
Delixi Electric IsraelHamelacha 22 Rosh HaayinSibel Park, 48091IsraelCell: +972-546798718Tel: +972-3-9551316Fax: +972-3-9551317Contact: Hayim CohenEmail: [email protected]
Delixi Electric West Africa1 Tunde Gaffar CloseOff Adeniyi JonesIkejaLagos
NigeriaFax: + 234 2703941Contact: Chidiebere NWORGUMobile: +234 703 41 111 [email protected]
Delixi Electric South East AsiaP.O.Box 7567Pejabat Post Besar Shah Alam40720 Shah AlamSelangor Darul EhsanTel: 03-78809564Fax: 03-78809540Contact: Ellis LeeEmail: [email protected]
Delixi Electric ArgentinaContact: Damian CattainoMobile: +54111545658952
Delixi Electric EgyptContact: Mohamed NagyMobile 20(0) 100705454
Delixi Electric Saudi ArabiaContact: Mohkam SheikhMobile: +966050269801
8/10/2019 Delixi Catalogue 2009
5/112
Power Distribution
Industry Control
Product Panorama
8/10/2019 Delixi Catalogue 2009
6/112
Contents
MCB Miniature Circuit Breakers
CDB6a 18mm Miniature Circuit Breakers 1
CDB6L 18mm Miniature Circuit Breakers 3
CDB6N 18mm Miniature Circuit Breakers 5
CDB6&CDB6LE Electrical Auxiliaries 7
CDB17 Miniature Circuit Breakers 8
CDB3 Phase-neutral Circuit Breakers 10
CDB2 27mm Miniature Circuit Breakers 11
CDB5 Switch Disconnectors 13
RCBO Residual Current Operated Circuit Breakers With
Integral Overcurrent Protection
CDB6LE Electronic Type Residual Current Operated Circuit Breakers 15
CDB3LE Electronic Type Residual Current Operated Circuit Breakers 17
CDB2LE Electronic Type Residual Current Operated Circuit Breakers 18
CDB7LSP Electronic Type Residual Current Operated Circuit Breakers 20
RCCB Residual Current Operated Circuit Breakers
Without Overcurrent Protection
CDL7 Electromagnetic Type Residual Current Switches 21
Surge Protector
CDY1 Surge Protective Devices 22
MCB Distribution Board
CDPZ50 Distribution Box 25
Meter
DDS607 Single-phase Electronic Watt-hour Meters
MCCB Moulded Case Circuit Breakers
CDM1 Moulded Case Circuit Breakers 29
ELCB Earth-leakage Circuit Breakers
CDM1L Moulded Case Circuit Breakers With Electronic Type Residual Current
Operated Protection 36
27
8/10/2019 Delixi Catalogue 2009
7/112
ACB Air Circuit Breaker
CDW7 Air Circuit Breaker 42
Contactors
CDC17 AC Contactor 61
Relays
CDR17 Thermal overload relays 70
Current TransformerLMK Current Transformer 73
Fuse
RT16 Fuse 76
RT18 Fuse 78
Power Distribution Box
JXF Power Distribution Box 80
Control Signal
LD11 Series of indicator light 82
LAY3 Serie of pushbuttons 86
LAY7 Serie of pushbuttons 88
LAY8 Serie of pushbuttons 93
Pannel Meter72 Series Pannel Meter 96
96 Series Pannel Meter 98
Voltage Stabilizer
TND Voltage Stabilizer 100
Nylon Lock
Nylon Cable Ties Series 102
8/10/2019 Delixi Catalogue 2009
8/112
Delixi Electric 1
Function CDB6a miniature circuit breakers combine the following functions:
Protection of circuits against overload currentsProtection of circuits against short-circuit currents
Control
Isolation
Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63 A
Rated voltage: 230/400V AC
Breaking capacity
Tropicalization: treatment 2
Protection degree: 2
Connection:
up to 25mm2cables
Tripping curves:
B curve: the magnetic release operates between 3 and 5 In
C curve: the magnetic release operates between 5 and 10 In
D curve: the magnetic release operates between 10 and 14 In
35 mm standard DIN rail mounting
Description Technical data
CDB6a
Standard: IEC 60898-1 IEC 60947-2
Trip Curve: B, C and D curves
Breaking Capacity: 3000A
Overall dimensions
Unit:mm
Voltage
(V)
230
400
230
400
230
400
Rate
current
1-63A
Type
B
C
D
Poles
1P
2P, 3P, 4P
1P
2P, 3P, 4P
1P
2P, 3P, 4P
Breaking capacity
Icn (A)
3000
Standard and certification
IEC 60898-1 IEC 60947-2
KEMA, CB
8/10/2019 Delixi Catalogue 2009
9/112
Delixi Electric2
CDB6a
Standard: IEC 60898-1 IEC 60947-2
Trip Curve: B, C and D curves
Breaking Capacity: 3000A
Type Rating
(A)
Width
(in mod.of 9mm)1361016202532405063
22222222222
1P
13610
16202532405063
4444
4444444
2P
136101620253240
5063
666666666
66
3P
D curveCDB6a1D1CDB6a1D3CDB6a1D6CDB6a1D10CDB6a1D16CDB6a1D20CDB6a1D25CDB6a1D32CDB6a1D40CDB6a1D50CDB6a1D63
CDB6a2D1CDB6a2D3CDB6a2D6CDB6a2D10
CDB6a2D16CDB6a2D20CDB6a2D25CDB6a2D32CDB6a2D40CDB6a2D50CDB6a2D63
CDB6a3D1CDB6a3D3CDB6a3D6CDB6a3D10CDB6a3D16CDB6a3D20CDB6a3D25CDB6a3D32CDB6a3D40
CDB6a3D50CDB6a3D63
Reference
B curveCDB6a1B1CDB6a1B3CDB6a1B6CDB6a1B10CDB6a1B16CDB6a1B20CDB6a1B25CDB6a1B32CDB6a1B40CDB6a1B50CDB6a1B63
CDB6a2B1CDB6a2B3CDB6a2B6CDB6a2B10
CDB6a2B16CDB6a2B20CDB6a2B25CDB6a2B32CDB6a2B40CDB6a2B50CDB6a2B63
CDB6a3B1CDB6a3B3CDB6a3B6CDB6a3B10CDB6a3B16CDB6a3B20CDB6a3B25CDB6a3B32CDB6a3B40
CDB6a3B50CDB6a3B63
C curveCDB6a1C1CDB6a1C3CDB6a1C6CDB6a1C10CDB6a1C16CDB6a1C20CDB6a1C25CDB6a1C32CDB6a1C40CDB6a1C50CDB6a1C63
CDB6a2C1CDB6a2C3CDB6a2C6CDB6a2C10
CDB6a2C16CDB6a2C20CDB6a2C25CDB6a2C32CDB6a2C40CDB6a2C50CDB6a2C63
CDB6a3C1CDB6a3C3CDB6a3C6CDB6a3C10CDB6a3C16CDB6a3C20CDB6a3C25CDB6a3C32CDB6a3C40
CDB6a3C50CDB6a3C63
88888888888
4P CDB6a4D1CDB6a4D3CDB6a4D6CDB6a4D10CDB6a4D16CDB6a4D20CDB6a4D25CDB6a4D32CDB6a4D40CDB6a4D50CDB6a4D63
CDB6a4B1CDB6a4B3CDB6a4B6CDB6a4B10CDB6a4B16CDB6a4B20CDB6a4B25CDB6a4B32CDB6a4B40CDB6a4B50CDB6a4B63
CDB6a4C1CDB6a4C3CDB6a4C6CDB6a4C10CDB6a4C16CDB6a4C20CDB6a4C25CDB6a4C32CDB6a4C40CDB6a4C50CDB6a4C63
1361016202532405063
Tripping Curve
B C D
8/10/2019 Delixi Catalogue 2009
10/112
Delixi Electric 3
CDB6L
Standard: IEC 60947-2 IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 4500A
Function CDB6L miniature circuit breakers combine the following functions:
Protection of circuits against overload currentsProtection of circuits against short-circuit currents
Control
Isolation
Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63 A
Rated voltage: 230/400V AC
Breaking capacity:
Description Technical data
Tropicalization: treatment 2
Protection degree: 2
Connection:
up to 25mm2cables
Tripping curves:
B curve: the magnetic release operates between 3 and 5 In
C curve: the magnetic release operates between 5 and 10 In
D curve: the magnetic release operates between 10 and 14 In
35 mm standard DIN rail mounting
Standard and certification
IEC 60947-2 IEC 60898-1
KEMA, CB
Overall dimensionsUnit:mm
Voltage(V)
230400
230
400
230
400
230
400
230
400
230
400
1P
2P, 3P, 4P
1P
2P, 3P, 4P
1P
2P, 3P, 4P
Breaking capacityIcn (A)
45004500
4500
4500
4500
4500
4500
4500
4500
4500
4500
4500
Ratecurrent
1-40A50A, 63A
1-40A
50A, 63A
1-40A
50A, 63A
1-40A
50A, 63A
1-40A
50A, 63A
1-40A
50A, 63A
Type
B
C
D
Poles
8/10/2019 Delixi Catalogue 2009
11/112
Delixi Electric4
CDB6L
Standard: IEC 60947-2 IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 4500A
1P
2P
3P
1361016202532405063
22222222222
13610
16202532405063
4444
4444444
136101620253240
5063
666666666
66
D curve
CDB6L1D1CDB6L1D3CDB6L1D6CDB6L1D10CDB6L1D16CDB6L1D20CDB6L1D25CDB6L1D32CDB6L1D40CDB6L1D50CDB6L1D63
CDB6L2D1CDB6L2D3CDB6L2D6CDB6L2D10
CDB6L2D16CDB6L2D20CDB6L2D25CDB6L2D32CDB6L2D40CDB6L2D50CDB6L2D63
CDB6L3D1CDB6L3D3CDB6L3D6CDB6L3D10CDB6L3D16CDB6L3D20CDB6L3D25CDB6L3D32CDB6L3D40
CDB6L3D50CDB6L3D63
C curve
CDB6L1C1CDB6L1C3CDB6L1C6CDB6L1C10CDB6L1C16CDB6L1C20CDB6L1C25CDB6L1C32CDB6L1C40CDB6L1C50CDB6L1C63
CDB6L2C1CDB6L2C3CDB6L2C6CDB6L2C10
CDB6L2C16CDB6L2C20CDB6L2C25CDB6L2C32CDB6L2C40CDB6L2C50CDB6L2C63
CDB6L3C1CDB6L3C3CDB6L3C6CDB6L3C10CDB6L3C16CDB6L3C20CDB6L3C25CDB6L3C32CDB6L3C40
CDB6L3C50CDB6L3C63
Reference
B curve
CDB6L1B1CDB6L1B3CDB6L1B6CDB6L1B10CDB6L1B16CDB6L1B20CDB6L1B25CDB6L1B32CDB6L1B40CDB6L1B50CDB6L1B63
CDB6L2B1CDB6L2B3CDB6L2B6CDB6L2B10
CDB6L2B16CDB6L2B20CDB6L2B25CDB6L2B32CDB6L2B40CDB6L2B50CDB6L2B63
CDB6L3B1CDB6L3B3CDB6L3B6CDB6L3B10CDB6L3B16CDB6L3B20CDB6L3B25CDB6L3B32CDB6L3B40
CDB6L3B50CDB6L3B63
Type Rating
(A)
Width
(in mod.of 9mm)
4P 1361016202532405063
88888888888
CDB6L4D1CDB6L4D3CDB6L4D6CDB6L4D10CDB6L4D16CDB6L4D20CDB6L4D25CDB6L4D32CDB6L4D40CDB6L4D50CDB6L4D63
CDB6L4C1CDB6L4C3CDB6L4C6CDB6L4C10CDB6L4C16CDB6L4C20CDB6L4C25CDB6L4C32CDB6L4C40CDB6L4C50CDB6L4C63
CDB6L4B1CDB6L4B3CDB6L4B6CDB6L4B10CDB6L4B16CDB6L4B20CDB6L4B25CDB6L4B32CDB6L4B40CDB6L4B50CDB6L4B63
Tripping Curve
B C D
8/10/2019 Delixi Catalogue 2009
12/112
8/10/2019 Delixi Catalogue 2009
13/112
Delixi Electric6
Standard: IEC 60947-2 IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 6000A
Type
1P
CDB6N
2P
3P
4P
Rating
(A)
Width
(in mod.of 9mm)
13610162025324050*63*
22222222222
13610
162025324050*63*
4444
4444444
136101620253240
50*63*
666666666
66
13610162025324050*63*
88888888888
D curve
CDB6N1D1
CDB6N1D3
CDB6N1D6
CDB6N1D10
CDB6N1D16
CDB6N1D20
CDB6N1D25
CDB6N1D32
CDB6N1D40
CDB6N1D50
CDB6N1D63
CDB6N2D1
CDB6N2D3
CDB6N2D6
CDB6N2D10
CDB6N2D16
CDB6N2D20
CDB6N2D25
CDB6N2D32
CDB6N2D40
CDB6N2D50
CDB6N2D63
CDB6N3D1
CDB6N3D3
CDB6N3D6
CDB6N3D10
CDB6N3D16
CDB6N3D20
CDB6N3D25
CDB6N3D32
CDB6N3D40
CDB6N3D50CDB6N3D63
CDB6N4D1
CDB6N4D3
CDB6N4D6
CDB6N4D10
CDB6N4D16
CDB6N4D20
CDB6N4D25
CDB6N4D32
CDB6N4D40
CDB6N4D50
CDB6N4D63
C curve
CDB6N1C1
CDB6N1C3
CDB6N1C6
CDB6N1C10
CDB6N1C16
CDB6N1C20
CDB6N1C25
CDB6N1C32
CDB6N1C40
CDB6N1C50
CDB6N1C63
CDB6N2C1
CDB6N2C3
CDB6N2C6
CDB6N2C10
CDB6N2C16
CDB6N2C20
CDB6N2C25
CDB6N2C32
CDB6N2C40
CDB6N2C50
CDB6N2C63
CDB6N3C1
CDB6N3C3
CDB6N3C6
CDB6N3C10
CDB6N3C16
CDB6N3C20
CDB6N3C25
CDB6N3C32
CDB6N3C40
CDB6N3C50CDB6N3C63
CDB6N4C1
CDB6N4C3
CDB6N4C6
CDB6N4C10
CDB6N4C16
CDB6N4C20
CDB6N4C25
CDB6N4C32
CDB6N4C40
CDB6N4C50
CDB6N4C63
Reference
B curve
CDB6N1B1
CDB6N1B3
CDB6N1B6
CDB6N1B10
CDB6N1B16
CDB6N1B20
CDB6N1B25
CDB6N1B32
CDB6N1B40
CDB6N1B50
CDB6N1B63
CDB6N2B1
CDB6N2B3
CDB6N2B6
CDB6N2B10
CDB6N2B16
CDB6N2B20
CDB6N2B25
CDB6N2B32
CDB6N2B40
CDB6N2B50
CDB6N2B63
CDB6N3B1
CDB6N3B3
CDB6N3B6
CDB6N3B10
CDB6N3B16
CDB6N3B20
CDB6N3B25
CDB6N3B32
CDB6N3B40
CDB6N3B50CDB6N3B63
CDB6N4B1
CDB6N4B3
CDB6N4B6
CDB6N4B10
CDB6N4B16
CDB6N4B20
CDB6N4B25
CDB6N4B32
CDB6N4B40
CDB6N4B50
CDB6N4B63
Tripping Curve
B C D
8/10/2019 Delixi Catalogue 2009
14/112
Delixi Electric 7
CDB6&CDB6LE Electrical Auxiliaries
OF contact auxiliary
Reference
CDB6OF230AC
CDB6OF400AC
CDB6OF24DC
CDB6OF48DC
CDB6OF110DC
CDB6OF220DC
CDB6SD230AC
CDB6SD400AC
CDB6SD24DC
CDB6SD48DC
CDB6SD110DC
CDB6SD220DCCDB6MX230AC
CDB6MX24AC
Voltage
AC230
AC400
DC24
DC48
DC110
DC220
AC230
AC400
DC24
DC48
DC110
DC220AC230
DC24
Type
OF
SD
MX+OF*
SD fault-indicating switch
MX+OF shunt trip release
8/10/2019 Delixi Catalogue 2009
15/112
Delixi Electric8
CDB17
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 6000A
Function CDB17N miniature circuit breakers combine the following functions:
Protection of circuits against overload currentsProtection of circuits against short-circuit currents
Control
Isolation
Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63 A
Rated voltage: 230/400V AC
Breaking capacity
Tropicalization: treatment 2
Protection degree: 2
Connection:
up to 25mm2cables
Tripping curves:
B curve: the magnetic release operates between 3 and 5 In
C curve: the magnetic release operates between 5 and 10 InD curve: the magnetic release operates between 10 and 14 In
35 mm standard DIN rail mounting
Description Technical data
Standard and certification
IEC 60898-1
KEMA, CB, CE
Overall dimensionsUnit:mm
Voltage(V)
230400
230
400
230
400
6000
Poles
1P2P,3P,4P
1P
2P,3P,4P
1P
2P,3P,4P
Type
B
C
D
Ratecurrent
1-63A
Breaking capacityIcn (A)
8/10/2019 Delixi Catalogue 2009
16/112
Delixi Electric 9
1P
2P
3P
4P
1361016202532405063
22222222222
13610
16202532405063
4444
4444444
136101620253240
5063
666666666
66
1361016202532405063
88888888888
D curve
CDB17N1D1CDB17N1D3CDB17N1D6CDB17N1D10CDB17N1D16CDB17N1D20CDB17N1D25CDB17N1D32CDB17N1D40CDB17N1D50CDB17N1D63
CDB17N2D1CDB17N2D3CDB17N2D6CDB17N2D10
CDB17N2D16CDB17N2D20CDB17N2D25CDB17N2D32CDB17N2D40CDB17N2D50CDB17N2D63
CDB17N3D1CDB17N3D3CDB17N3D6CDB17N3D10CDB17N3D16CDB17N3D20CDB17N3D25CDB17N3D32CDB17N3D40
CDB17N3D50CDB17N3D63
CDB17N4D1CDB17N4D3CDB17N4D6CDB17N4D10CDB17N4D16CDB17N4D20CDB17N4D25CDB17N4D32CDB17N4D40CDB17N4D50CDB17N4D63
C curve
CDB17N1C1CDB17N1C3CDB17N1C6CDB17N1C10CDB17N1C16CDB17N1C20CDB17N1C25CDB17N1C32CDB17N1C40CDB17N1C50CDB17N1C63
CDB17N2C1CDB17N2C3CDB17N2C6CDB17N2C10
CDB17N2C16CDB17N2C20CDB17N2C25CDB17N2C32CDB17N2C40CDB17N2C50CDB17N2C63
CDB17N3C1CDB17N3C3CDB17N3C6CDB17N3C10CDB17N3C16CDB17N3C20CDB17N3C25CDB17N3C32CDB17N3C40
CDB17N3C50CDB17N3C63
CDB17N4C1CDB17N4C3CDB17N4C6CDB17N4C10CDB17N4C16CDB17N4C20CDB17N4C25CDB17N4C32CDB17N4C40CDB17N4C50CDB17N4C63
Reference
B curve
CDB17N1B1CDB17N1B3CDB17N1B6CDB17N1B10CDB17N1B16CDB17N1B20CDB17N1B25CDB17N1B32CDB17N1B40CDB17N1B50CDB17N1B63
CDB17N2B1CDB17N2B3CDB17N2B6CDB17N2B10
CDB17N2B16CDB17N2B20CDB17N2B25CDB17N2B32CDB17N2B40CDB17N2B50CDB17N2B63
CDB17N3B1CDB17N3B3CDB17N3B6CDB17N3B10CDB17N3B16CDB17N3B20CDB17N3B25CDB17N3B32CDB17N3B40
CDB17N3B50CDB17N3B63
CDB17N4B1CDB17N4B3CDB17N4B6CDB17N4B10CDB17N4B16CDB17N4B20CDB17N4B25CDB17N4B32CDB17N4B40CDB17N4B50CDB17N4B63
Type Rating
(A)
Width
(in mod.of 9mm)
CDB17
Standard: IEC 60898-1
Trip Curve: B, C and D curves
Breaking Capacity: 6000A
Tripping Curve
B C D
8/10/2019 Delixi Catalogue 2009
17/112
Delixi Electric10
Function CDB3 phase-neutral circuit breakers combine the following functions:Protection of circuits against overload currentsProtection of circuits against short-circuit currentsControlIsolation
Rated current: 6, 10, 16, 20, 25, 32A
Rated voltage: 230V AC
Breaking capacity: 3 kA
Tripping curves:
C curve: the magnetic release operates between 5 and 10 In
D curve: the magnetic release operates between 10 and 14 In
Tropicalization: treatment 2
Protection degree: 2
Connection
Up to 16mm
2
cables35mm standard DIN rail mounting
Description Technical data
Overall dimensions
Type Rating
(A)
Width
(in mod.of 9mm)
Reference
C curve D curve
6
10
16
20
25
32
2
2
2
2
2
2
CDB3a5C6
CDB3a5C10
CDB3a5C16
CDB3a5C20
CDB3a5C25
CDB3a5C32
CDB3a5D6
CDB3a5D10
CDB3a5D16
CDB3a5D20
CDB3a5D25
CDB3a5D32
1P+N
CDB3
Standard: IEC 60898-1
Trip Curve: C and D curves
Breaking Capacity: 3000A
Standard and certification
IEC 60898-1
C D
Tripping Curve
8/10/2019 Delixi Catalogue 2009
18/112
Delixi Electric 11
Function CDB2 miniature circuit breakers combine the following functions:
Protection of circuits against overload currentsProtection of circuits against short-circuit currents
Control
Isolation
Description Technical dataRated current: 63, 80, 100, 125 A
Rated voltage : 230/400V AC
Breaking capacity
CDB2
Standard: IEC 60947-2
Trip Curve: C and D curves
Breaking Capacity: 10000A
Standard and certification
IEC 60947-2
SEMKO, CE
Overall dimensions
Tripping curves:
C curve: the magnetic release operates between 5 and 10 In
D curve: the magnetic release operates between 10 and 14 In
Mechanical durability: 8,500 (In 100A) / 7,000 (In=125A)
Electrical durability: 1,500 (In 100A) / 1,000 (In=125A)
Tropicalization: treatment 2
Protection degree: 2
Connection
Up to 50 mm2
cables35mm standard DIN rail mounting
Closed position indication
TypeRating
(A)
Voltage
(V)
Breaking capacity
(kA)
63 ~125 230
400
10
10
1P
2/3/4P
Unit:mm
8/10/2019 Delixi Catalogue 2009
19/112
Delixi Electric12
CDB2
Standard: IEC 60947-2
Trip Curve: C and D curves
Breaking Capacity: 10000A
Type Rating
(A)
Width
(in mod.of 9mm)
Reference
C curve D curve
63
80
100
125
3
3
3
3
CDB2H1C63
CDB2H1C80
CDB2H1C100
CDB2H1C125
CDB2H1D63
CDB2H1D80
CDB2H1D100
CDB2H1D125
1P
63
80
100
125
6
6
6
6
2P
63
80
100
125
9
9
9
9
3P
63
80
100
125
12
12
12
12
4P
CDB2H2C63
CDB2H2C80
CDB2H2C100
CDB2H2C125
CDB2H2D63
CDB2H2D80
CDB2H2D100
CDB2H2D125
CDB2H3C63
CDB2H3C80
CDB2H3C100
CDB2H3C125
CDB2H3D63
CDB2H3D80
CDB2H3D100
CDB2H3D125
CDB2H4C63
CDB2H4C80
CDB2H4C100
CDB2H4C125
CDB2H4D63
CDB2H4D80
CDB2H4D100
CDB2H4D125
C D
Tripping Curve
8/10/2019 Delixi Catalogue 2009
20/112
8/10/2019 Delixi Catalogue 2009
21/112
Delixi Electric14
CDB5
Standard: IEC 60947-3
Type Rating
(A)
Voltage
(V AC)
Reference
1P
2P
3P
4P
Width
(in mod.of 9mm)20
32
63
100
230
230
230
230
2
2
2
2
400
400
400
400
4
4
4
4
20
32
63
100
400
400
400
400
6
6
6
6
20
32
63
100
400
400
400
400
8
8
8
8
CDB5120
CDB5132
CDB5163
CDB51100
CDB5220
CDB5232
CDB5263
CDB52100
CDB5320
CDB5332
CDB5363
CDB53100
CDB5420
CDB5432
CDB5463
CDB54100
20
32
63
100
8/10/2019 Delixi Catalogue 2009
22/112
Delixi Electric 15
Function CDB6LE electronic type residual current operated circuit breakers combine the follow-
ing functions:Overload protection
Protection against short-circuit current
Protection for users against indirect contact
Additional protection for users against direct contacts (30mA)
Protection for electrical installations against insulation faults (fire hazard, etc)
Isolation
Rated current: 6, 10, 16, 20, 25, 32, 40, 50, 60A
Rated voltage: 230V AC for 1P+N/2P, 400V AC for 3P/3P+N/4P
Sensitivity: 30 mA
Tropicalization: treatment 2
Protection degree: 2
Connection
Up to 16 mm2cables
Tripping curves:
C curve: the magnetic release operates between 5 and 10 In
D curve: the magnetic release operates between 10 and 14 In
Mechanical indication of the earth fault on the front face by a black mechanical
indicator
35 mm standard DIN rail mounting.
Description Technical data
CDB6LEStandard: IEC 61009
Trip Curve: C and D curves
Breaking Capacity: 3000A
Sensitivity: 30mA
Standard and certification
IEC 61009
Overall dimensions
CDB6LE-32
CDB6LE-63
8/10/2019 Delixi Catalogue 2009
23/112
Delixi Electric16
CDB6LEStandard: IEC 61009
Trip Curve: C and D curves
Breaking Capacity: 3000A
Sensitivity: 30mA
6101620
2532405060
4003P+N 30 11111111
1111141414
CDB6LEa4C6SCDB6LEa4C10SCDB6LEa4C16SCDB6LEa4C20S
CDB6LEa4C25SCDB6LEa4C32SCDB6LEa4C40SCDB6LEa4C50SCDB6LEa4C60S
CDB6LEa4D6SCDB6LEa4D10SCDB6LEa4D16SCDB6LEa4D20S
CDB6LEa4D25SCDB6LEa4D32SCDB6LEa4D40SCDB6LEa4D50SCDB6LEa4D60S
61016202532405060
4003P 30 101010101010121212
CDB6LEa3C6SCDB6LEa3C10SCDB6LEa3C16SCDB6LEa3C20SCDB6LEa3C25SCDB6LEa3C32SCDB6LEa3C40SCDB6LEa3C50SCDB6LEa3C60S
CDB6LEa3D6SCDB6LEa3D10SCDB6LEa3D16SCDB6LEa3D20SCDB6LEa3D25SCDB6LEa3D32SCDB6LEa3D40SCDB6LEa3D50SCDB6LEa3D60S
2P 777777
888
CDB6LEa2C6SCDB6LEa2C10SCDB6LEa2C16SCDB6LEa2C20SCDB6LEa2C25SCDB6LEa2C32S
CDB6LEa2C40SCDB6LEa2C50SCDB6LEa2C60S
CDB6LEa2D6SCDB6LEa2D10SCDB6LEa2D16SCDB6LEa2D20SCDB6LEa2D25SCDB6LEa2D32S
CDB6LEa2D40SCDB6LEa2D50SCDB6LEa2D60S
230 30 61016202532
405060
Type Width
(in mod.of 9mm)
Reference
C curve D curve
Voltage
(V)
Sensitivity
(mA)
2301P+N 30 555555666
CDB6LEa1C6SCDB6LLEa1C10SCDB6LEa1C16SCDB6LEa1C20SCDB6LEa1C25SCDB6LEa1C32SCDB6LEa1C40SCDB6LEa1C50SCDB6LEa1C60S
CDB6LEa1D6SCDB6LEa1D10SCDB6LEa1D16SCDB6LEa1D20SCDB6LEa1D25SCDB6LEa1D32SCDB6LEa1D40SCDB6LEa1D50SCDB6LEa1D60S
Rating
(A)
61016202532405060
61016202532405060
4004P 30 131313131313161616
CDB6LEa6C6SCDB6LEa6C10SCDB6LEa6C16SCDB6LEa6C20SCDB6LEa6C25SCDB6LEa6C32SCDB6LEa6C40SCDB6LEa6C50SCDB6LEa6C60S
CDB6LEa6D6SCDB6LEa6D10SCDB6LEa6D16SCDB6LEa6D20SCDB6LEa6D25SCDB6LEa6D32SCDB6LEa6D40SCDB6LEa6D50SCDB6LEa6D60S
Tripping Curve
B C D
8/10/2019 Delixi Catalogue 2009
24/112
Delixi Electric 17
Function CDB3LE electronic type residual current operated circuit breakers combine the fol-lowing functions:
Protection of circuits against overload currentsProtection of circuits against short-circuit currentsProtection of users against indirect contact
Additional protection for users against d irect contacts (30mA)Protection of electrical installations against insulation faults (fire hazard, etc)Isolation
Rated current: 6, 10, 16, 20, 25, 32, 40ARated voltage: 230V ACBreaking capacity: 3kASensitivity: 30mATripping curve:C curve: the magnetic release operates between 5 and 10 InTropicalization: treatment 2Protection degree: 2ConnectionUp to 6 mm2cablesMechanical indication of the earth fault on the front face by a red mechanical indicator35 mm standard DIN rail mounting
Description Technical data
Overall dimensions
Type Sensltivity(mA)
301P+N
Width (in mod.of 9mm)
4
Rating(A)
610162025
3240
CDB3LEa5C6SCDB3LEa5C10SCDB3LEa5C16SCDB3LEa5C20SCDB3LEa5C25S
CDB3LEa5C32SCDB3LEa5C40S
Standard and certification
IEC 61009
CDB3LEStandard: IEC 61009
Trip Curve: C curves
Breaking Capacity: 3000A
Sensitivity: 30mA
Reference C curve
Unit:mm
Tripping Curve
C
8/10/2019 Delixi Catalogue 2009
25/112
Delixi Electric18
Function CDB2LE electronic type residual current operated circuit breakers combine the follow-
ing functions:Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Protection of users against indirect contact
Protection of electrical installations against insulation faults (fire hazard, etc)
Isolation
Rated current: 63A, 80A,100A
Rated voltage: 230V for 1P+N; 400V for 2P/3P/3P+N/4P
Sensitivity: 100mA,300mA
Rated ultimate short-circuit breaking capacity (Icu): 10,000A
Rated service short-circuit breaking capacity (Ics): 7,500ATripping curves:
C curve: the magnetic release operates between 5 and 10 In
D curve: the magnetic release operates between 10 and 14 In
2 types of residual current tripping are available:
Instantaneous
Time-delay with a maximum delay time of 0.2 s
Tropicalization: treatment 2
Protection degree: 2
Connection
Up to 50 mm2cables
Mechanical indication of the earth fault on the front face by a black mechanical
indicator
Closed position indication
35 mm standard DIN rail mounting
Description Technical data
Overall dimensions
Standard and certification
IEC 60947-2
CDB2LEStandard: IEC 60947-2
Trip Curve: C and D curves
Breaking Capacity: 10000A
Sensitivity: 100mA, 300mA
Unit:mm
8/10/2019 Delixi Catalogue 2009
26/112
Delixi Electric 19
Type Width
(in mod.of 9mm)
1P+N
Reference
C curve
Rating
(A)
63
80
100
63
80
100
Sensitivity
(mA)
100
100
100
300
300
300
6
D curve
CDB2LEH1D63Y
CDB2LEH1D80Y
CDB2LEH1D100Y
CDB2LEH1D63T
CDB2LEH1D80T
CDB2LEH1D100T
CDB2LEH1C63Y
CDB2LEH1C80Y
CDB2LEH1C100Y
CDB2LEH1C63T
CDB2LEH1C80T
CDB2LEH1C100T
CDB2LEStandard: IEC 60947-2
Trip Curve: C and D curves
Breaking Capacity: 10000A
Sensitivity: 100mA, 300mA
2P 63
80
100
63
80
100
100
100
100
300
300
300
9 CDB2LEH2D63Y
CDB2LEH2D80Y
CDB2LEH2D100Y
CDB2LEH2D63T
CDB2LEH2D80T
CDB2LEH2D100T
CDB2LEH2C63Y
CDB2LEH2C80Y
CDB2LEH2C100Y
CDB2LEH2C63T
CDB2LEH2C80T
CDB2LEH2C100T
3P 63
80
100
63
80
100
100
100
100
300
300
300
12 CDB2LEH3D63Y
CDB2LEH3D80Y
CDB2LEH3D100Y
CDB2LEH3D63T
CDB2LEH3D80T
CDB2LEH3D100T
CDB2LEH3C63Y
CDB2LEH3C80Y
CDB2LEH3C100Y
CDB2LEH3C63T
CDB2LEH3C80T
CDB2LEH3C100T
3P+N 63
80
100
63
80
100
100
100
100
300
300
300
12 CDB2LEH6D63Y
CDB2LEH6D80Y
CDB2LEH6D100Y
CDB2LEH6D63T
CDB2LEH6D80T
CDB2LEH6D100T
CDB2LEH6C63Y
CDB2LEH6C80Y
CDB2LEH6C100Y
CDB2LEH6C63T
CDB2LEH6C80T
CDB2LEH6C100T
4P 63
80
100
63
80
100
100
100
100
300
300
300
15 CDB2LEH4D63Y
CDB2LEH4D80Y
CDB2LEH4D100Y
CDB2LEH4D63T
CDB2LEH4D80T
CDB2LEH4D100T
CDB2LEH4C63Y
CDB2LEH4C80Y
CDB2LEH4C100Y
CDB2LEH4C63T
CDB2LEH4C80T
CDB2LEH4C100T
C D
Tripping Curve
8/10/2019 Delixi Catalogue 2009
27/112
Delixi Electric20
Function CDB7LSP electronic type residual current operated circuit breakers combine the
following functions:Protection of circuits against overload currents
Protection of circuits against short-circuit currents
Protection of users against indirect contact
Additional protection for users against direct contacts (30mA)
Protection of electrical installations against insulation faults (fire hazard, etc)
Rated current: 6, 10, 16, 20, 25, 32, 40A
Rated voltage: 230V AC
Breaking capacity: 6kA
Sensitivity: 30mATripping curve:
B curve: the magnetic release operates between 3 and 5 In
C curve: the magnetic release operates between 5 and 10 In
D curve: the magnetic release operates between 10 and 14 In
Tropicalization: treatment 2
Protection degree: 2
Connection
Up to 10 mm2 cables
Mechanical indication of the earth fault on the front face by a red mechanical
indicator 35 mm standard DIN rail mounting
Description Technical data
Overall dimensions
Type Rating
(A)
Width
(mm)
Reference
B curve D curve
6
10
16
20
25
32
40
18
18
18
18
18
18
18
CDB7LSPN1B6S
CDB7LSPN1B10S
CDB7LSPN1B16S
CDB7LSPN1B20S
CDB7LSPN1B25S
CDB7LSPN1B32S
CDB7LSPN1B40S
CDB7LSPN1D6S
CDB7LSPN1D10S
CDB7LSPN1D16S
CDB7LSPN1D20S
CDB7LSPN1D25S
CDB7LSPN1D32S
CDB7LSPN1D40S
1P+N
CDB7LSPStandard: IEC 61009
Trip Curve: C and D curves
Breaking Capacity: 6000A
Sensitivity:30mA
Standard and certificationIEC 61009
Voltage
(V)
230
Sensitivity
(mA)
30
C curve
CDB7LSPN1C6S
CDB7LSPN1C10S
CDB7LSPN1C16S
CDB7LSPN1C20S
CDB7LSPN1C25S
CDB7LSPN1C32S
CDB7LSPN1C40S
8/10/2019 Delixi Catalogue 2009
28/112
Delixi Electric 21
Function CDL7 electromagnetic type residual current switch combine the following functions:
Protection for users against indirect contactAdditional protection for users against direct contacts (30mA)
Protection for electrical installations against insulation faults (fire hazard, etc)
Isolation
DescriptionRated current: 25, 40, 63, 80, 100A
Rated voltage: 230/400V AC
Sensitivity: 10mA, 30mA, 100mA, 300mA
Mechanical durability: 2000
Electrical durability: 1000
Tropicalization: treatment 2
Protection degree: 2
Connection
Tunnel terminals
Up to 16 mm2cables
Type A or type AC RCCB, without overload or short-circuit protection
Dont need any auxiliary supply source.
Instantaneous earth fault trip, unadjustable
Mechanical indication of the earth fault on the front face by a red mechanical
indicator35 mm standard DIN rail mounting
Technical data
CDL7
Standard:IEC 61008
Sensitivity: 10mA, 30mA, 100mA, 300mA
RCCB: Type A , Type AC
Overall dimensions
Standard and certification
IEC 61008
KEMA, CB
Unit:mm
8/10/2019 Delixi Catalogue 2009
29/112
Delixi Electric22
CDL7
Standard:IEC 61008
Sensitivity: 10mA, 30mA, 100mA, 300mA
RCCB: Type A , Type AC
Type Width
(in mod.of 9mm)
Sensitivity
(mA)
2P 10
30
30
30
30
30
100
100
100
100
100
300
300300
300
300
100
100
100
300
300
300
4
Rating
(A)
25
25
40
63
80
100
25
40
63
80
100
25
4063
80
100
63
80
100
63
80
100
4P 10
30
30
30
30
30
100
100
100
100
100
300
300300
300
300
100
100
100
300
300
300
8 25
25
40
63
80
100
25
40
63
80
100
25
4063
80
100
63
80
100
63
80
100
CDL7225LA
CDL7225SA
CDL7240SA
CDL7263SA
CDL7280SA
CDL72100SA
CDL7225YA
CDL7240YA
CDL7263YA
CDL7280YA
CDL72100YA
CDL7225TA
CDL7240TACDL7263TA
CDL7280TA
CDL72100TA
CDL7263YAS
CDL7280YAS
CDL72100YAS
CDL7263TAS
CDL7280TAS
CDL72100TAS
CDL7425LA
CDL7425SA
CDL7440SA
CDL7463SA
CDL7480SA
CDL74100SA
CDL7425YA
CDL7440YA
CDL7463YA
CDL7480YA
CDL74100YA
CDL7425TA
CDL7440TACDL7463TA
CDL7480TA
CDL74100TA
CDL7463YAS
CDL7480YAS
CDL74100YAS
CDL7463TAS
CDL7480TAS
CDL74100TAS
Reference
A type AC type
CDL7225LC
CDL7225SC
CDL7240SC
CDL7263SC
CDL7280SC
CDL72100SC
CDL7225YC
CDL7240YC
CDL7263YC
CDL7280YC
CDL72100YC
CDL7225TC
CDL7240TCCDL7263TC
CDL7280TC
CDL72100TC
CDL7263YCS
CDL7280YCS
CDL72100YCS
CDL7263TCS
CDL7280TCS
CDL72100TCS
CDL7425LC
CDL7425SC
CDL7440SC
CDL7463SC
CDL7480SC
CDL74100SC
CDL7425YC
CDL7440YC
CDL7463YC
CDL7480YC
CDL74100YC
CDL7425TC
CDL7440TCCDL7463TC
CDL7480TC
CDL74100TC
CDL7463YCS
CDL7480YCS
CDL74100YCS
CDL7463TCS
CDL7480TCS
CDL74100TCS
8/10/2019 Delixi Catalogue 2009
30/112
Delixi Electric 23
CDY1 Surge Protective Devices
Standard: IEC61643-1
Function
Description
CDY1 surge protective devices provide:
Applicable to household appliances and the like to offer protection When there is an over-voltage caused by either lightning strike or operation in the
circuit
Technical data
Type
Pole
Nominal discharge current
In(8/20us) kA
Maximum discharge
current Imax(8/20us) kA
Maximum continuous
operational voltage Uc V
Protection level Up kV
Leakage cur rent
(75%Uc 1mA) uA
Response time ns
CDY1-80 CDY1-100 CDY1-120CDY1-60CDY1-40
1P+N, 2P
5
10
275
1.3
20
25
CDY1-10 CDY1-20
1P, 1P+N, 2P, 3P, 3P+N, 4P
10
20
275
1.3
385
1.5
420
1.8
20
40
Standard and certification IEC61643-1
Overall dimensions
CDY1-10 CDY1-20 40 60
CDY1-80 100 120
30
60
40
80
50
100
60
120
320
1.3
275
1.5
385
1.8
420
2
275
2
420
2.5
385
2.2
275
2
420
2.2
385
2.2
275
2.2
420
2.5
385
2.5
275
2.2
420
2.5
385
2.5
8/10/2019 Delixi Catalogue 2009
31/112
Delixi Electric24
CDY1 Surge Protective Devices
Standard: IEC61643-1
Note:" " express Maximum continuous operational voltage (Uc) code
275V
275
320V
320
385V
385
420V
420
Imax ReferncePole
10KA
10KA
20KA
20KA
20KA
20KA
20KA
20KA
40KA
40KA
40KA
40KA
40KA
40KA
60KA
60KA
60KA
60KA
60KA
60KA
80KA
80KA
80KA
80KA
80KA
80KA
100KA
100KA
100KA
100KA
100KA
100KA
120KA
120KA
120KA
120KA
120KA
120KA
20KA
40KA
60KA
60KA
80KA
100KA
120KA
1P+N
2P
1P
2P
3P
4P
1P+N
3P+N
1P
2P
3P
4P
1P+N
3P+N
1P
2P
3P
4P
1P+N
3P+N
1P
2P
3P
4P
1P+N
3P+N
1P
2P
3P
4P
1P+N
3P+N
1P
2P
3P
4P
1P+N
3P+N
Phase modle
Phase modle
Phase modle
N-PE
N-PE
N-PE
N-PE
CDY1105
CDY1102
CDY1201
CDY1202
CDY1203
CDY1204
CDY1205
CDY1206
CDY1401
CDY1402
CDY1403
CDY1404
CDY1405
CDY1406
CDY1601
CDY1602
CDY1603
CDY1604
CDY1605
CDY1606
CDY1801
CDY1802
CDY1803
CDY1804
CDY1805
CDY1806
CDY11001
CDY11002
CDY11003
CDY11004
CDY11005
CDY11006
CDY11201
CDY11202
CDY11203
CDY11204
CDY11205
CDY11206
CDY120PM
CDY140PM
CDY160PM
CDY160NP
CDY180NP
CDY1100NP
CDY1120NP
Uc
8/10/2019 Delixi Catalogue 2009
32/112
Delixi Electric 25
Function CDPZ50 distribution box provides illumination devices, sockets and electrical appli-
ances with functions as follows: Protection against overload
Protection against over voltage
Protection against leakage
Description Technical data
Type
Surface installation
Flush installation
The amount of unit loop*
6
8
12
16
20
24
6
8
1216
20
24
CDPZ50
Standard: IEC60439-1 IEC60670
Reference
CDPZ50M6
CDPZ50M8
CDPZ50M12
CDPZ50M16
CDPZ50M20
CDPZ50M24
CDPZ50R6
CDPZ50R8
CDPZ50R12CDPZ50R16
CDPZ50R20
CDPZ50R24
*:18mm for one unit loop
Rated operational voltage
Maximum rated current
Rated insulation voltage
Rated frequency Degree of protection
Instantaneous withstand current
Construction feature
Holistic steel-plastic construction
Free assembly of components
Beautiful design
Flame retardant industrial plastic in panel
The whole panel can move vertically
Standard and certification
IEC60439-1 IEC60670
AC 400V or AC 230V
100A
500V
50Hz/60HzIP30
6KA
8/10/2019 Delixi Catalogue 2009
33/112
Delixi Electric26
Overall dimension
CDPZ50
Standard: IEC60439-1 IEC60670
Surface installation Flush installation
Unit:mm
Loop number
6
8
12
16
20
24*
Surface installation
A
171
207
279
351
423
364
*:two rows product
B
220
220
220
220
220
303
Flush installation
A
163
199
279
343
413
383
B
220
220
220
220
220
282
Thickness
C
90
90
90
90
90
90
8/10/2019 Delixi Catalogue 2009
34/112
Delixi Electric 27
Technical Data
Accuracy class: 1.0, 2.0
Reference voltage:220V
Current specification:1.5(6)A,3(6)A,2.5(10)A,5(20)A,5(30)A
10(40)A,15(60)A,20(80)A,30(100)A
Power: 2W/10VA (voltage circuit), 4VA(Current circuit)
Two-way measurement function:
Extended functions: Optional liquid crystal display, infrared communications and 485
communications
Normal work temperature:-10-~+45
Limit working temperature:-25-~+55
Normal work voltage:0.9~1.1 Reference voltage
Limit work voltage:0.7~1.2 Reference voltage
Relative Humidity: 85%
Installation conditions:Meter should be installed in indoor drying, ventilation, fire-resistant, solid
walls height of 1.8 m about the use of non-corrosive gases in the nvironment,
should be moisture-proof.
Lightning request:Thunderstorms in more places should be installed in the
installation of lightning equipment
Standard and Certification
IEC620531-21:2003
KEMA
Overall dimensions
DDS607 single-phase electronic watt-hour meter provide:
Measuring energy in household and commercial single-phase network services
Function
Description
Being able to accurately measure, antitwodirections of power and
the total electricityconsumption in one direction
Single-phase Type A,C Meter Single-phase LCD Meter
DDS607 Single-phase Electronic Watt-hour Meter
Standard:IEC 620531-21:2003
8/10/2019 Delixi Catalogue 2009
35/112
Delixi Electric28
Ordering informationn
Type A (Import chip)
Type A (Import chip)
Type A (Import chip)
Type A (Import chip)
Type A (Import chip)
Type A (Import chip)
Type A (Import chip)
Type A (Import chip)
Type C (Domestic chip)
Type C (Domestic chip)
Type C (Domestic chip)
Type C (Domestic chip)
Type C (Domestic chip)
Type C (Domestic chip)
Type C (Domestic chip)
Type C (Domestic chip)
LCD without 485 communications
LCD without 485 communications
LCD without 485 communications
LCD without 485 communications
LCD without 485 communicationsLCD without 485 communications
LCD without 485 communications
LCD with 485 communications
LCD with 485 communications
LCD with 485 communications
LCD with 485 communications
LCD with 485 communications and infrared communications
LCD with 485 communications and infrared communications
LCD with 485 communications and infrared communications
LCD with 485 communications and infrared communications
LCD with 485 communications and infrared communications
LCD with 485 communications and infrared communications
LCD with 485 communications and infrared communications
LCD with 485 communications and infrared communications
1.5(6)A
2.5(10)A
5(20)A
5(30)A
10(40)A
15(60)A
20(80)A
30(100)A
1.5(6)A
2.5(10)A
5(20)A
5(30)A
10(40)A
15(60)A
20(80)A
30(100)A
1.5(6)A
2.5(10)A
5(20)A
5(30)A
10(40)A15(60)A
20(80)A
1.5(6)A
5(20)A
10(40)A
15(60)A
1.5(6)A
2.5(10)A
5(20)A
5(30)A
10(40)A
15(60)A
20(80)A
30(100)A
DDS607N16M4A
DDS607N110M4A
DDS607N120M4A
DDS607N130M6A
DDS607N140M4A
DDS607N160M4A
DDS607N180M4A
DDS607N1100M3A
DDS607N26M4A
DDS607N210M4C
DDS607N220M4C
DDS607N230M6C
DDS607N240M4C
DDS607N260M4C
DDS607N280M4C
DDS607N2100M3C
DDS607N16M4CD
DDS607N110M4CD
DDS607N120M4CD
DDS607N130M6CD
DDS607N140M4CDDDS607N160M4CD
DDS607N180M4CD
DDS607N16M4CD485
DDS607N120M4CD485
DDS607N140M4CD485
DDS607N160M4CD485
DDS607N116M4CD485I
DDS607N110M4CD485I
DDS607N120M4CD485I
DDS607N130M6CD485I
DDS607N140M4CD485I
DDS607N160M4CD485I
DDS607N180M4CD485I
DDS607N1100M3CD485I
Function DescriptionCurrentspecification Reference
Note: Users need special specifications can be customized
DDS607 Single-phase Electronic Watt-hour Meter
Standard:IEC 620531-21:2003
8/10/2019 Delixi Catalogue 2009
36/112
Delixi Electric 29
Description Technical data
CDM1
Standard: IEC 60947-2
Function CDM1 molded case circuit breakers can be used to provide the following functions:
Main technical parameters are shown in the table below
Constructional features
Thermamagnetic release offers instantaneous trip against short-circuit and long
time delay trip against overcurrent
The circuit breaker can be of fixed type or plug-in type
For 4-pole circuit breakers:
N-pole without overcurrent release, it switches on and off with other poles ( N-
pole lead-make, lag-break)
Various accessories can be attached to the circuit breaker to extend its functions,
such as undervoltage release, shunt release, ON/OFF position indication contact,
and tripped position indication contact, for detail see the accessories part
Standard and certification
IEC 60947-2
KEMA, SEMKO, CB, CE
CDM1-63
63
3P,4P
50
10 16
20 25
32 40
50 63
690V
6000V
400V
50
25
30
18
50
120
4000
6000
25
30
Type
Frame size rated
current A
Number of poles
Rated frequency Hz
Rated current In A
Rated insulation
voltage Ui V
Rated impulse
withstand
voltage Uimp V
Rated operationalvoltage Ue V
Icu kA
(400V)
Ics kA
(400V)
Arcing distance mm
Durability
Power consu-
mpution W
CDM1-100
100
2P,3P,4P
16 20
25 30
32 40
50 63
80 100
800V
8000V
400V / 690V
50
35
30
26
120
3000
7000
40
50
CDM1-225
225
100 125
160 180
200 225
50
35
30
26
120
1500
6500
60
75
CDM1-400
400
200 350
250 315
400
400V
70
50
40
30
100
60
1000
4000
40
110
CDM1-630
630
3P,4P
400 500
630
400V690V
65
45
42
34
60
1000
4000
150
200
CDM1-800
800
400 500
630 700
800
400V
70
50
40
30
20
500
2500
135
190
CDM1-1250
1250
3P
700 800
1000
1250
85
-
45
-
20
500
2500
240
300
Type M
Type L
Type M
Type L
Cycles/h
Electrical
Mechanical
Fixed
Plug-in
To distribute electric power and protect circuits and equipment against overload,undervoltage, and short-circuit faults
To protect motors against overload, undervoltage and short-circuit faults (Inm400A)
To infrequently start and control AC motors
8/10/2019 Delixi Catalogue 2009
37/112
Delixi Electric30
CDM1
Standard: IEC 60947-2
Type Reference
CDM1-63 3P
4P
CDM1-100 2P
3P
4P
CDM1-225 2P
In A
10
16
20
25
32
40
50
63
10
16
20
25
32
40
50
63
16
20
25
32
40
50
63
80
100
16
20
25
32
40
50
63
80
100
16
20
2532
40
50
63
80
100
100
125
160
180
200
225
Type MCDM163M103
CDM163M163
CDM163M203
CDM163M253
CDM163M323
CDM163M403
CDM163M503
CDM163M633
CDM163M104
CDM163M164
CDM163M204
CDM163M254
CDM163M324
CDM163M404
CDM163M504
CDM163M634
CDM1100M162
CDM1100M202
CDM1100M252
CDM1100M322
CDM1100M402
CDM1100M502
CDM1100M632
CDM1100M802
CDM1100M1002
CDM1100M163
CDM1100M203
CDM1100M253
CDM1100M323
CDM1100M403
CDM1100M503
CDM1100M633
CDM1100M803
CDM1100M1003
CDM1100M164
CDM1100M204
CDM1100M254CDM1100M324
CDM1100M404
CDM1100M504
CDM1100M634
CDM1100M804
CDM1100M1004
CDM1225M1002
CDM1225M1252
CDM1225M1602
CDM1225M1802
CDM1225M2002
CDM1225M2252
Type LCDM163L103
CDM163L163
CDM163L203
CDM163L253
CDM163L323
CDM163L403
CDM163L503
CDM163L633
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
CDM1100L163
CDM1100L203
CDM1100L253
CDM1100L323
CDM1100L403
CDM1100L503
CDM1100L633
CDM1100L803
CDM1100L1003
--
--
----
--
--
--
--
--
--
--
--
--
--
--
8/10/2019 Delixi Catalogue 2009
38/112
Delixi Electric 31
CDM1
Standard: IEC 60947-2
Type ReferenceIn A
3P
4P
CDM1-400 3P
4P
CDM1-630 3P
4P
CDM1-800 3P
4P
CDM1-1250 3P
100
125
160
180
200
225
100
125
160
180
200
225200
225
250
315
350
400
200
215
250
315
350
400
400
500
630
400
500
630
400
500
630
700
800
400
500
630
700
800
700
800
1000
1250
Type M
CDM1225M1003
CDM1225M1253
CDM1225M1603
CDM1225M1803
CDM1225M2003
CDM1225M2253
CDM1225M1004
CDM1225M1254
CDM1225M1604
CDM1225M1804
CDM1225M2004
CDM1225M2254CDM1400M2003
CDM1400M2253
CDM1400M2503
CDM1400M3153
CDM1400M3503
CDM1400M4003
CDM1400M2004
CDM1400M2254
CDM1400M2504
CDM1400M3154
CDM1400M3504
CDM1400M4004
CDM1630M4003
CDM1630M5003
CDM1630M6303
CDM1630M4004
CDM1630M5004
CDM1630M6304
CDM1800M4003
CDM1800M5003
CDM1800M6303
CDM1800M7003
CDM1800M8003
CDM1800M4004
CDM1800M5004
CDM1800M6304
CDM1800M7004
CDM1800M8004
CDM11250M7003
CDM11250M8003
CDM11250M10003
CDM11250M12503
Type L
CDM1225L1003
CDM1225L1253
CDM1225L1603
CDM1225L1803
CDM1225L2003
CDM1225L2253
--
--
--
--
--
--CDM1400L2003
CDM1400L2253
CDM1400L2503
CDM1400L3153
CDM1400L3503
CDM1400L4003
--
--
--
--
--
--
CDM1630L4003
CDM1630L5003
CDM1630L6303
--
--
--
CDM1800L4003
CDM1800L5003
CDM1800L6303
CDM1800L7003
CDM1800L8003
--
--
--
--
--
--
--
--
--
Note: The connection mode for CDM1 is the fixed type front connection.
8/10/2019 Delixi Catalogue 2009
39/112
Delixi Electric32
CDM1
Standard: IEC 60947-2
Overall dimensions
Unit:mm
2P 3P 4P
Key to overall dimensions
Type
CDM1-63L
CDM1-63M
CDM1-63M
CDM1-100M
CDM1-100L
CDM1-100M
CDM1-100M
CDM1-225M
CDM1-225L
CDM1-225M
CDM1-225M
CDM1-400L,M
CDM1-400M
CDM1-630L,M
CDM1-630M
CDM1-800L,M
CDM1-800M
CDM1-1250M
Poles
3
3
4
2
3
3
4
2
3
3
4
3
4
3
4
3
4
3
Install dimensions
a
25
25
25
--
30
30
30
--
35
35
35
44
44
58
58
70
70
70
b
117
117
117
129
129
129
129
126
126
126
126
215
215
200
200
243
243
375
d
3.5
3.5
3.5
4.5
4.5
4.5
4.5
5.5
5.5
5.5
5.5
6.5
6.5
7
7
7
7
10
Overall dimensions
L
135
135
135
150
150
150
150
165
165
165
165
257
257
270
270
280
280
406
L1
21
21
21
51
51
51
51
64
64
64
64
105
105
118
118
102
102
104
W
76
76
103
65
92
92
122
75
107
107
142
140
184
182
240
210
280
210
H
89.5
99
99
103.5
87
103.5
103.5
124.5
108
124.5
124.5
146
146
160
160
146
146
190
H2
21
28
28
24
25
24
24
24.5
24.5
24
24.5
36.5
36.5
41
41
34.5
34.5
58.5
H1
74
82
82
87
68
87
87
104
87
104
104
100
100
108
108
103
103
140.5
8/10/2019 Delixi Catalogue 2009
40/112
Delixi Electric 33
CDM1
Standard: IEC 60947-2
A
117
129
126
215
200
243
B
25
30
35
44
58
70
H
49
54
54
76
83
76
Unit:mm
Unit:mm
A
35
35
6560
48
B
11.5
31
1515
15
H
46
48
6161
66
8/10/2019 Delixi Catalogue 2009
41/112
Delixi Electric34
CDM1
Standard: IEC 60947-2
The accessories are fixed into the circuit breaker.
MN (Undervoltage Release)
Accessories
Technical data
Rated operating voltage Us(V)
Drop-out voltage(V)
Pick-up voltage(V)
230V, 400V AC
(0.35~0.7) Us
(0.85~1.1) Us
MX (Shunt Release)
Technical data
Rated control voltage US(V)
Operating voltage(V)
230V, 400V AC
(0.7~1.1) US
OF (Auxiliary Contact)
Rated thermal current Ith 3A
Rated operating voltage US(V)
1NO+1NC (Change over)
2NO+2NC (Change over)
SD (Alarm Switch)
Rated thermal current Ith 3A
Rated operating voltage US(V)
1NO+1NC
Technical data
0.4A (400V AC)
Technical data
0.26A (400V AC)
0.4A (400V AC)
8/10/2019 Delixi Catalogue 2009
42/112
Delixi Electric 35
CDM1
Standard: IEC 60947-2
Ordering information
Type
CDM1-63
CDM1-100
CDM1-225
CDM1-400
CDM1-630
CDM1-800
CDM1-1250
Voltage (V)
230V AC
400V AC
Reference
MN*
CDM163MN230
CDM163MN400
CDM1100MN230
CDM1100MN400
CDM1225MN230
CDM1225MN400
CDM1400MN230
CDM1400MN400
CDM1630MN230
CDM1630MN400
CDM1800MN230
CDM1800MN400
CDM11250MN230
CDM11250MN400
MX*
CDM163MX230
CDM163MX400
CDM1100MX230
CDM1100MX400
CDM1225MX230
CDM1225MX400
CDM1400MX230
CDM1400MX400
CDM1630MX230
CDM1630MX400
CDM1800MX230
CDM1800MX400
CDM11250MX230
CDM11250MX400
OF
CDM163OF
CDM1100OF
CDM1225OF
CDM1400OF
CDM1630OF
CDM1800OF
CDM11250OF
SD
CDM163SD
CDM1100SD
CDM1225SD
CDM1400SD
CDM1630SD
CDM1800SD
TR(Round Handle)
CDM163TR
CDM1100TR
CDM1225TR
CDM1400TR
CDM1630TR
CDM1800TR
TS(Square Handle)
CDM163TS
CDM1100TS
CDM1225TS
CDM1400TS
CDM1630TS
CDM1800TS
8/10/2019 Delixi Catalogue 2009
43/112
Delixi Electric36
CDM1L
Standard: IEC 60947-2
Function CDM1L molded case circuit breakers with electronic type residual current operated
protection can be used to provide the following functions:To distribute electric power and protect circuits and equipment against overload,
undervoltage, and short-circuit faults
To infrequently start and control AC motors
To protect users against indirect contact
To protect electrical installations against insulation faults (fire hazard, etc)
Description Technical data
Main technical parameters are shown in the table below
Table for 4 pole CDM1LE (Neutral line)
Code
A
B
Note
N(direct connect)
N(direct connect N pole lead-make, lag-break)
Type
Frame size rated current A
Rated current In A
Rated frequency Hz
Rated insulation voltage Ui V
Rated operational voltage Ue V
Rated impulse withstand voltage Uimp V
Number of poles
Icu kA
(400V)
Ics kA
(400V)
Rated residual
operating
current I n mA
Rated residual non-operating
current I no mA
Durability
CDM1L-100
100
16 20 25 32 40
50 63 80 100
50
800
400
8000
3P, 4P
50
35
35
22
30/100/500
100/300/500
100/300/500
1/2 I n
1500
8500
10000
CDM1L-225
225
100 125 140 160
180 200 225
50
35
35
22
30/100/500
100/300/500
100/300/500
1/2 I n
1000
7000
8000
CDM1L-400
400
200 250 315
350 400
70
50
40
30
100/300/500
100/300/500
1/2 I n
1000
4000
5000
Type M
Type L
Type M
Type L
Without delay
With delay
Electrical
Mechanical
Total
Maximum break time for residual operating current protection
Number of poles
Max. break
time S
Without delay
With delay
I n
0.2
0.5/1.15/2.15
2 I n
0.1
0.35/1/2
5 I n
0.04
0.25/0.9/1.9
10 I n
0.04
0.25/0.9/1.9
8/10/2019 Delixi Catalogue 2009
44/112
Delixi Electric 37
CDM1L
Standard: IEC 60947-2
Constructional features
Thermamagnetic release offers instantaneous trip against short-circuit and long time delay trip against overcurrentThe residual operating current value can be fixed or adjustable
The residual operating current protection can be with time-delay or without time-delay
Various accessories can be attached to the circuit breaker to extend its functions, such as undervoltage release, shunt release, ON/OFF position
indication contact, and tripped position indication contact, for detail see the accessories part
Standard and certification
IEC 60947-2
CE
Ordering information
8/10/2019 Delixi Catalogue 2009
45/112
Delixi Electric38
CDM1L
Standard: IEC 60947-2
Reference
Type MCDM1LE100M163
CDM1LE100M203
CDM1LE100M253
CDM1LE100M323
CDM1LE100M403
CDM1LE100M503
CDM1LE100M633
CDM1LE100M803
CDM1LE100M1003
CDM1LE100M164 A
CDM1LE100M204 A
CDM1LE100M254 A
CDM1LE100M324 A
CDM1LE100M404 A
CDM1LE100M504 A
CDM1LE100M634 A
CDM1LE100M804 A
CDM1LE100M1004 A
CDM1LE100M164 B
CDM1LE100M204 B
CDM1LE100M254 B
CDM1LE100M324 B
CDM1LE100M404 B
CDM1LE100M504 B
CDM1LE100M634 B
CDM1LE100M804 B
CDM1LE100M1004 B
CDM1LE225M1003
CDM1LE225M1253
CDM1LE225M1403
CDM1LE225M1603
CDM1LE225M1803
CDM1LE225M2003
CDM1LE225M2253
CDM1LE225M1004 A
CDM1LE225M1254 A
CDM1LE225M1404 A
CDM1LE225M1604 A
CDM1LE225M1804 A
CDM1LE225M2004 A
CDM1LE225M2254 A
CDM1LE225M1004 B
CDM1LE225M1254 B
CDM1LE225M1404 B
CDM1LE225M1604 B
CDM1LE225M1804 B
CDM1LE225M2004 B
CDM1LE225M2254 B
CDM1LE400M2003
CDM1LE400M2503
CDM1LE400M3153CDM1LE400M3503
CDM1LE400M4003
Type
CDM1L-100 3P
4P A
4P B
CDM1L-225 3P
4P A
4P B
CDM1-400 3P
Rated current
In A16
20
25
32
40
50
63
80
100
16
20
25
32
40
50
63
80
100
16
20
25
32
40
50
63
80
100
100
125
140
160
180
200
225
100
125
140
160
180
200
225
100
125
140
160
180
200
225
200
250
315350
400
Type LCDM1LE100L163
CDM1LE100L203
CDM1LE100L253
CDM1LE100L323
CDM1LE100L403
CDM1LE100L503
CDM1LE100L633
CDM1LE100L803
CDM1LE100L1003
CDM1LE100L164 A
CDM1LE100L204 A
CDM1LE100L254 A
CDM1LE100L324 A
CDM1LE100L404 A
CDM1LE100L504 A
CDM1LE100L634 A
CDM1LE100L804 A
CDM1LE100L1004 A
CDM1LE100L164 B
CDM1LE100L204 B
CDM1LE100L254 B
CDM1LE100L324 B
CDM1LE100L404 B
CDM1LE100L504 B
CDM1LE100L634 B
CDM1LE100L804 B
CDM1LE100L1004 B
CDM1LE225L1003
CDM1LE225L1253
CDM1LE225L1403
CDM1LE225L1603
CDM1LE225L1803
CDM1LE225L2003
CDM1LE225L2253
CDM1LE225L1004 A
CDM1LE225L1254 A
CDM1LE225L1404 A
CDM1LE225L1604 A
CDM1LE225L1804 A
CDM1LE225L2004 A
CDM1LE225L2254 A
CDM1LE225L1004 B
CDM1LE225L1254 B
CDM1LE225L1404 B
CDM1LE225L1604 B
CDM1LE225L1804 B
CDM1LE225L2004 B
CDM1LE225L2254 B
CDM1LE400L2003
CDM1LE400L2503
CDM1LE400L3153CDM1LE400L3503
CDM1LE400L4003
8/10/2019 Delixi Catalogue 2009
46/112
Delixi Electric 39
CDM1L
Standard: IEC 60947-2
Overall dimensions
Type
CDM1L-100L
CDM1L-100M
CDM1L-225L
CDM1L-225M
CDM1L-400L,M
Poles
3
4
34
3
4
3
4
3
4
Overall size
L1 L2 L3 L4
150max
150max
150max150max
165max
165max
165max
165max
257max
257max
94max
94max
110max110max
94max
94max
110max
110max
146max
146max
75max
75max
92max92max
72max
72max
90max
90max
103max
103max
Installation size
a b d
30
60
3060
35
70
35
70
88
88
129
129
129129
126
126
126
126
194
194
4 4.5
6 4.5
4 4.56 4.5
4 4.5
6 4.5
4 4.5
6 4.5
4 4.5
6 6.5
Key to overall dimensions
92max
122max
92max122max
107max
142max
107max
142max
154max
198max
Unit:mm
Reference
Type M
CDM1LE400M2004 A
CDM1LE400M2254 A
CDM1LE400M2504 A
CDM1LE400M3154 A
CDM1LE400M3504 A
CDM1LE400M4004 A
CDM1LE400M2004 B
CDM1LE400M2254 B
CDM1LE400M2504 B
CDM1LE400M3154 B
CDM1LE400M3504 B
CDM1LE400M4004 B
Type
4P A
CDM1L-400 4P B
Rated current
In A
200
225
250
315
350
400
200
225
250
315
350
400
Type L
CDM1LE400L2004 A
CDM1LE400L2254 A
CDM1LE400L2504 A
CDM1LE400L3154 A
CDM1LE400L3504 A
CDM1LE400L4004 A
CDM1LE400L2004 B
CDM1LE400L2254 B
CDM1LE400L2504 B
CDM1LE400L3154 B
CDM1LE400L3504 B
CDM1LE400L4004 B
8/10/2019 Delixi Catalogue 2009
47/112
Delixi Electric40
CDM1L
Standard: IEC 60947-2
Centrally revolvable type
Frame
Dimension
Dimension for handle mechanism
CDM1L-100
49
CDM1L-225
55
CDM1L-400
74
Unit:mm
Handle mechanism
Square Handle
The accessories are fixed into the circuit breaker.
MN (Undervoltage Release)
Accessories
Technical data
Rated operating voltage US(V)
Drop-out voltage(V)
Pick-up voltage(V)
230V, 400V AC
(0.35~0.7) Us
(0.85~1.1) Us
8/10/2019 Delixi Catalogue 2009
48/112
Delixi Electric 41
CDM1L
Standard: IEC 60947-2
MX (Shunt Release)
Technical data
Rated control voltage Us(V)
Operating voltage(V)
230V, 400V AC
(0.7~1.1) Us
OF (Auxiliary Contact)
Rated thermal current Ith 3A
Rated operating voltage Us(V)1NO+1NC (Change over)
2NO+2NC (Change over)
Technical data
0.4A (400V AC)
SD (Alarm Switch)
Rated thermal current Ith 3A
Rated operating voltage Us(V)
1NO+1NC
Technical data
0.26A (400V AC)
0.4A (400V AC)
Type
CDM1L-100
CDM1L-225
CDM1L-400
Ordering information
Reference
MN*
CDM1LE100MN230
CDM1LE100MN400
CDM1LE225MN230
CDM1LE225MN400
CDM1LE400MN230
CDM1LE400MN400
Voltage
(V)
230V AC
400V AC
MX*
CDM1LE100MX230
CDM1LE100MX400
CDM1LE225MX230
CDM1LE225MX400
CDM1LE400MX230
CDM1LE400MX400
OF
CDM1LE100OF
CDM1LE225OF
CDM1LE400OF
SD
CDM1LE100SD
CDM1LE225SD
CDM1LE400SD
TS(Square Handle)
CDM1LE100TS
CDM1LE225TS
CDM1LE400TS
TR(Round Handle)
CDM1LE100TR
CDM1LE225TR
CDM1LE400TR
8/10/2019 Delixi Catalogue 2009
49/112
Delixi Electric42
CDW7
Standard: IEC 60947-2
Application
Appl ied to power distribution of AC 50Hz/60Hz, rated operational voltage 400/
690V, rated current 200A~6300A and lower
For power distribution and protecting circuit and power supply equipment aganist
harm from overload, undervoltage, short circuit, earthing, and other faults
Circuit breaker which ampere frame size is under 630A can protect motor aganist
overload,undervoltage and shortcircuit
Core parts use intelligent control unit which has accurate discrimination protection, it
can avoid unnecessary power failure and enhance the reliability of power supply
system
Standard and certification
International standard: IEC609472
Approved certification: CB, CE, KEMA
Operating condition and installation recommendation
Ambient temperature shall be controlled between
+40 and -5 , the average temperature in 24 hours
shall not exceed +35
Note:contacting manufacturer about circuit breaker
used in place where ambient temperature is higher
than +40 or lower than -5
8/10/2019 Delixi Catalogue 2009
50/112
Delixi Electric 43
CDW7
Standard: IEC 60947-2
Parameter and characteristics
Certification approved: IEC 60947-1 IEC 60947-2
CDW7-1000
3, 4
B
0
400
690
8000
50
200/400/630
/800/1000
42
--
30
--
88
--
30
--
9000
1000
CDW7-2000
3, 4
B
0
400/690
800
8000
50
630/800/1000
/1250/1600/2000
80
50
50
40
176
105
50
40
9000
1000
CDW7-3200
3, 4
B
0
400/690
800
8000
50
2000/2500
/3200
100
65
80
50
220
143
65
50
4500
500
CDW7-6300
3, 4
B
0
400
800
8000
50
4000/5000
/6300
120
--
100
--
264
--
85
--
1500
500
In
Icu
Ics
Icm
AC 400V
AC 690V
AC 400V
AC 690V
AC 400V
AC 690V
AC 400V
AC 690V
8/10/2019 Delixi Catalogue 2009
51/112
Delixi Electric44
Fault and alarm reset buttonFault/Alarm LED
In normal state, this LED is off. In case of fault release, the red LED will flash quickly; in case of
alarm, the red LED will be on constantlyNormal LED As long as the controller is on and operates normally, the green LED always flashes
Communication indicator The communication state indication is as follows: Profibus: OFF if no communication; ON if communication exists Modbus: OFF if no communication; flash if communication exists Device Net: Flash if no communication; ON if communication exists
Curve LEDs Red LEDs exist behind the curve. In case of fault release, the corresponding LED will flash indicating the fault type; During the parameter setting process, the LED is always on and
indicates the current item.
KeypadMeasure key l, used to switch to the default measurement menu.Set key 2, used to switch to the parameter setting menu.Protection Key 3, used to switch to the protection parameter setting menu.Info key 4, used to switch to the historical record and maintenance menu.Up, Move up the cursor through the menu items on the current level, or
increment the value of the selected parameter.Down, Move down the cursor through the menu items on the current
level, or decrement the value of the selected parameter.Exit, exit from the current level and return to the upper level, or cancel the
current parameter selection.Select, Select to enter into the next level from the current item, or select the current parameter, or store the change.
CDW7
Standard: IEC 60947-2
Protection characteristics
8/10/2019 Delixi Catalogue 2009
52/112
Delixi Electric 45
CDW7
Standard: IEC 60947-2
8/10/2019 Delixi Catalogue 2009
53/112
Delixi Electric46
CDW7
Standard: IEC 60947-2
8/10/2019 Delixi Catalogue 2009
54/112
Delixi Electric 47
ECWS- H
Different curves
available for long time
delay protection
Different curves
available for inverse
short time delay protec-
tion
Definite short time delay
protection
Instantaneous protection
Current unbalance (open
phase) protection
Earth protection
Earth fault alarm
Neutral phase protection
Load monitor
ECW - M
ECW - H
DO Signal alarm function
MCR and out-of-limit
tripping protection
Earth fault or leakageprotection (either)
Over-voltage protection
Under-voltage protection
Voltage unbalance
protection
Over-currency protection
Under-frequency
protection
Phase protection
Inverse power protection
Demand protection
Zonal system interlock
protection
Communication function
Long time delay protec-
tion
Definite time delay +
inverse time delay forshort time delay protec-
tion
Instantaneous protection
Earthing protection
Load monitor
Different curves
available for long time
delay protection
Different curves
available for inverse
short time delay protec-
tion
Definite short time delay
protection
Instantaneous protection
MCR and out-of-limit
tripping protection
Current unbalance (open
phase) protection
Earth protection
Earth fault alarm
Neutral phase protection
Load monitor
Max. phase current
Four phase current (I1,
I2, I 3, IN) and earth
current
Four phase current (I1,
I2, I 3, IN) and earth
current
Thermal capacity
Digital display
LED indication
Key operation
Digital setting ofprotection param-
eters
LCD display of
Chinese GUI
LED indication
Key operation
Fault log
Self-diagnosis
function
Feature test
function
Up to 8 fault logs
Up to 8 alarm logs
Up to 8 position logs
Historical current
peak
Contact equivalence
Number of operating
cycles
Fault clock function
Self-diagnosis fault
log
Self-diagnosis
function
Feature test
function
CDW7
Standard: IEC 60947-2
Four phase current (I1,
I2, I 3, IN) and earth
current
Thermal capacity
Up to 8 fault logs
Up to 8 alarm logs
Up to 8 position logs
Historical current peak
Contact equivalence
Number of operating
cycles
Clock function
Self-diagnosis function
LCD display of
Chinese GUI
LED indication
Key operation
MCR and out-of-limit
tripping protection
DO Signal alarm function
Communication function
8/10/2019 Delixi Catalogue 2009
55/112
Delixi Electric48
ECW-H intelligent controllers
Ir1=(0.4~1)ln
2h
1h
15,30,60,120,240,360,480,
600,720,840,960
8.4,16.9,33.8,67.5,135,202.5,270,337.5,405,472.5,540
Ir2=(1.5~15)In
10%
Ts=K/10(N2-1),(Ts 20ms)
0.1,0.2,0.3,0.4
0.06,0.13,0.2,0.27
Ir4=(0.2~1.0)In
10%
0.1s~1s(Rank difference 0.1s)
CDW7-1000
ECWS-H intelligent control-
lers
Ir1=(0.4~1)ln
2h
2h
8,12.8,19.2,32,48,64,80,
108,144,224,320,480,640,
800,960,1120
3.32,5.32,8.00,13.32,20.00,
26.66,33.30,45.00,60.00,
93.32,133,200,266,333,
400,433
1.25,2.00,3.00,5.00,7.50,
10.0,12.5,16.8,22.5,35.0,
50.0,75.0,100,125,150,162
Ir2=(1.5~15)In
15%
Ts=K/10(N2-1),(Ts 20ms)
0.1,0.2,0.3,0.4
0.06,0.13,0.2,0.27
1.05 Ir1 h
1.3 Ir1 h
1.5Ir1
2.0Ir1
3.0Ir1
CDW7
Standard: IEC 60947-2
CDW7-2000~6300
ECW-M intelligent controllers
Ir1=(0.4~1)ln
2h
1h
15,30,60,120,240,480
8.4,16.9,33.8,67.5,135,270
Ir2=(0.4~15)In
10%
I2Ts= 8Ir1)2ts
0.1,0.2,0.3,0.4
0.06,0.16,0.25,0.34
Ir4=(0.2~1.0)In
10%
0.1~0.4s (Rank difference 0.1s)
ECW-M
CDW7-2000
Ir3=1In~50KA+OFF
15%
ECWS-H ECW-H
CDW7-1000~6300A
(1.0~20)ln
15%
Ir4=(0.2~1.0)In
10%
0.1s~1s(Rank difference 0.1s)
CDW7-3200
Ir3=1In~75KA+OFF
15%
CDW7-6300
IIr3=1In~100KA+OFF
15%
8/10/2019 Delixi Catalogue 2009
56/112
Delixi Electric 49
AC 380V
(0.35~0.7)Ue
(0.85~1.1)Ue
0.35Ue
36VA
5VA
AC380 AC220 DC220 DC110
36VA 24VA 24W 24W
5VA 5VA 5W 5W
(0.7~1.1)Us
less than 30ms
7-2000~6300
AC380 AC220 DC220 DC110
36VA 24VA 24W 24W
10VA 10VA 10W 10W
(0.85~1.1)Us
less than 70ms
CDW7
Standard: IEC 60947-2
Auxiliary functions
AC220V
(0.35~0.7)Ue
(0.85~1.1)Ue
0.35Ue
24VA
5VA
8/10/2019 Delixi Catalogue 2009
57/112
Delixi Electric50
AC-15
10
1
1
0.3
10
1.1
0.3
10
DC-13
1
1
1
6Pe
1.1
1.1
6Pe
10
CDW7
Standard: IEC 60947-2
AC380 AC220 DC220 DC110
85VA 85VA 85VA 85VA
110VA 110VA 110VA 110VA
150VA 150VA 150VA 150VA
80VA 80VA 80VA 80VA
(0.85~1.1)Us
less than 5s
Pe 50W T0.95es upper limit 300ms
U/Ue
cos 0.95
I/Ie
U/Ue
cos T0.
CDW7-
2000~6300
CDW7-1000
In 2000A
2000A In 3200A
3200A In 6300A
8/10/2019 Delixi Catalogue 2009
58/112
Delixi Electric 51
200, 400
630
800, 1000
200, 400
630
800, 1000
CDW7-1000A fixed circuit breaker outline and horizonal/vertical connected dimension
L
266
266
266
336
336
336
L1
244
244
244
314
314
314
N
6
12
12
8
16
16
L2
-
-
-
70
70
70
CDW7
Standard: IEC 60947-2
Overall and mounting dimension
8/10/2019 Delixi Catalogue 2009
59/112
Delixi Electric52
200, 400
630
800, 1000
200, 400
630
800, 1000
CDW7-1000A drawout type circuit breaker outline and horizonal/vertical wiring Unit:mm
3P
4P
L
284
284
284
354
354
354
L1
194
194
194
264
264
264
L3
55
75
75
55
75
75
L4
63
83
83
63
83
83
L2
-
-
-
70
70
70
n
6
12
12
8
16
16
H
6
8
10
6
8
10
CDW7
Standard: IEC 60947-2
8/10/2019 Delixi Catalogue 2009
60/112
8/10/2019 Delixi Catalogue 2009
61/112
Delixi Electric54
CDW7-2000
CDW7-3200
CDW7-6300
(4000/5000A)
CDW7-6300
CDW7-2000A~6300A drawout type circuit breaker outline and horizonal/vertical connection Unit:mm
In A
400~800
1000~1600
2000
2000~2500
3200~4000
3200~4000
4000
5000~6300
5000~6300
a
10
15
20
20
30
30
20
30
30
3P
4P
3P
4P
4000A
3P
4P
3P
L1
375
375
470
435
550
550
813
928
928
L2
335
335
430
395
510
510
773
888
888
L3
292
292
292
352
352
352
352
352
352
L4
265
265
360
325
440
440
703
818
818
L5
247
247
247
307
307
307
307
307
307
W1
461
461
461
471
471
494
494
494
494
W2
507
507
507
517
517
540
540
540
540
b
179
179
179
189
189
212
212
212
212
W7-3200 can expand to 4000A,which mounting dimension is as same as 4P of CDW7-3200
DW7-2000 the mounting dimension is same regardless of different current used in"horizonal-connected" or "vertical-connected"
CDW7
Standard: IEC 60947-2
CDW7-2000A~6300A
CDW7-2000A drawout circuit breaker vertical connection diagram
8/10/2019 Delixi Catalogue 2009
62/112
Delixi Electric 55
CDW7-2000~6300 panel cut-out dimension and mounting dimension Unit:mm
CDW7-2000
CDW7-3200
CDW7-6300
a
306
366
366
b
346
406
406
c
3P
0
0
189(4000/5000A)
246.5(6300A)
4P
47.5
57.5
246.5(4000/5000A)
--
CDW7
Standard: IEC 60947-2
CDW7-1000
CDW7-2000~6300
CDW7-2000~6300A
CDW7-2000~6300A
CDW7-1000ACDW7-1000A
8/10/2019 Delixi Catalogue 2009
63/112
Delixi Electric56
41 42 when controller power choose DC,the output is DC24V,user can select DC
power module
43 44 circuit breaker status detection terminal(used when MCR function included)
45 overload pre-alarm signal output
46 automatic diagnosis alarm signal output
47 fault trip alarm signal output
48 earthing but non-tripping,only alarm signal output
49 four groups of contacts output common terminal
50 51 externally sensor input terminal
58 able to directly connect to power supply(automatic pre-energization),also able
to join up with normal open pushbutton to connect to power supply(manual pre-energization)
F X with different current ratings shall con-
nect with different sources.
CDW7
Standard: IEC 60947-2
Auxiliary connection diagramn
8/10/2019 Delixi Catalogue 2009
64/112
Delixi Electric 57
CDW7
Standard: IEC 60947-2
Pin functions:
Pin 1# and 2#: Auxiliary power input,pin 1# is
positive for DC input
Pin 3#, 4#, 5#: Fault trip contact output (4# is
common terminal); contact capacity: AC380V, 16A
Pin 6# and 7#, 8# and 9#: Two groups of auxiliary
contacts for breaker status; contact capacity:
AC380V, 16A
12#,13#(Contact1)and 14#,15#(Contact2)and 16#,
17#(Contact3)and 18#,19#(Contact4):Output of
four groups of signal for controllers,contact
capacity:4A/240V 7A/24VDC
20#: Earth protection
21#~24#:input of voltage signal (Note:the order cant
be wrong)
Note: 1. If the control voltage values of Q, F, X, and M are different to each
other, these components can be connected to different power supply units; in the
application, the shunt release and closing electromagnet shall be connected
serially with normally open and normally closed auxiliary contacts (the part
enclosed by dotted lines shall be connected by the user; the part represented by a
two-dot chain line is the wiring of circuit 51);
Note 2: The pin 35# can be connected to the power supply directly (automatic
pre-energy storage) or connected serially to a normally open button and then to
the power supply (manual pre-energy storage);
Note 3: If the user requests, pin #6~#7 can be connected to normally closed
contacts;
Note 4: The ECW power supply module I is a DC power supply module, and itcan be omitted if the power supply is AC power supply; the polarity and lead-ins/
lead-outs shall not be reversed (for draw-out type circuit breakers, the lead-outs
of the power supply module has been connected before the circuit break is
shipped from the factory);
Note 5: In case of circuit 47, the auxiliary contacts are four closed and four
open contacts; pin #25 and #26 are input terminals of an external current trans-
former , used for earth fault protection as (3P+N)T type ;
Note 6: In case of circuit 51, the auxiliary contacts are six closed and six open
contacts (or five closed and five open contacts); pin #25, #26, and #51 form
normally open and normally closed contacts;
Note 7: If Profibus or any other protocol is used, ECW-H + DP conversion module
and other conversion modules must be ordered; ECW power supply module lV and
ECW201 relay module must be ordered separately; Note 8:Pin #12~#19 input/output contacts can be user-defined programmable
signal contacts.
Components:
Q - Under-voltage release
F - Shunt release
X Closing electromagnet
DF - Auxiliary switch
M - Motor
SB1Button for closing
SB2Button for shunt
8/10/2019 Delixi Catalogue 2009
65/112
Delixi Electric58
1# 2#: 1# is the front terminal when DC is supplied by auxiliary power
3# 4# 5
AC380V 16A
6# 7# 8# 9#:
two groups of circuit breaker status auxiliary terminal: AC380V 16A
10# 11#: respectively as the communication leading-out of RS485A ,RS485B
12#: overload pre-alarm signal output
13#: communication remote control shunt release output
14#: communication remote control closing output or instantaneous short time-delay
trip signal output
15#: communication remote control energy storage or long time-delay trip signal output
16#: S-earth(RS-485 transmissionn common ground wire
17#: load monitor output1
19#: signal output common earth wire
21#: neutral voltage signal N phase
23#: voltage signal B phase
1
2: terminal 35# can directly connect to power supply
(automatic pre-energy storage),or join up with normal open
push