Top Banner
DDI-HeatExchangers Inc. DDI-HeatExchangers Inc. www.ddi-heatexchangers.com www.ddi-heatexchangers.com DDI Since 1980 DDI Since 1980
42
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: DDI-HeatExchangers Inc.  DDI Since 1980.

DDI-HeatExchangers Inc.DDI-HeatExchangers Inc.

www.ddi-heatexchangers.comwww.ddi-heatexchangers.comDDI Since 1980DDI Since 1980

Page 2: DDI-HeatExchangers Inc.  DDI Since 1980.

Poster

Page 3: DDI-HeatExchangers Inc.  DDI Since 1980.
Page 4: DDI-HeatExchangers Inc.  DDI Since 1980.

Sketch Anaerobic Digestion

Page 5: DDI-HeatExchangers Inc.  DDI Since 1980.

Advantages

Page 6: DDI-HeatExchangers Inc.  DDI Since 1980.

These 2 HX have been in These 2 HX have been in continuous non-stop operation continuous non-stop operation

for for 9 years9 years withoutwithout any any maintenancemaintenance

Page 7: DDI-HeatExchangers Inc.  DDI Since 1980.

NapaneeNapanee

Page 8: DDI-HeatExchangers Inc.  DDI Since 1980.

Pembroke

Page 9: DDI-HeatExchangers Inc.  DDI Since 1980.

Comparison Flier

Page 10: DDI-HeatExchangers Inc.  DDI Since 1980.

Payback is possible in 1 yearPayback is possible in 1 year

Page 11: DDI-HeatExchangers Inc.  DDI Since 1980.

Energy Saved (15 Years)

Page 12: DDI-HeatExchangers Inc.  DDI Since 1980.

Energy ROIEnergy ROI

Page 13: DDI-HeatExchangers Inc.  DDI Since 1980.

Electricity CostElectricity Cost

Page 14: DDI-HeatExchangers Inc.  DDI Since 1980.

Cogeneration

Page 15: DDI-HeatExchangers Inc.  DDI Since 1980.

DDI HXDDI HX

Page 16: DDI-HeatExchangers Inc.  DDI Since 1980.

DDI Outline

Page 17: DDI-HeatExchangers Inc.  DDI Since 1980.

Tube Disadvantages –Heat Area

Page 18: DDI-HeatExchangers Inc.  DDI Since 1980.

Tube Disadvantages - Length

Page 19: DDI-HeatExchangers Inc.  DDI Since 1980.

Tube Disadvantages - Sludge

Page 20: DDI-HeatExchangers Inc.  DDI Since 1980.

DDI Sketch w/ advantages

Page 21: DDI-HeatExchangers Inc.  DDI Since 1980.

SPIRAL technology gets SPIRAL technology gets BLOCKED,BLOCKED, Max. gap is only 1” Max. gap is only 1” and has pins for other liquid (no and has pins for other liquid (no

% solids there).% solids there). - 1“- - 1“-

Page 22: DDI-HeatExchangers Inc.  DDI Since 1980.

TUBE Technology cannot have TUBE Technology cannot have same flow for both liquids, and same flow for both liquids, and 3” gap each, at the same time.3” gap each, at the same time.

Page 23: DDI-HeatExchangers Inc.  DDI Since 1980.

DrawingDrawing

Page 24: DDI-HeatExchangers Inc.  DDI Since 1980.
Page 25: DDI-HeatExchangers Inc.  DDI Since 1980.

Vitalix 65-70 % Solids Vitalix 65-70 % Solids MolassesMolasses

12 Sep 200712 Sep 2007• Vitalix Inc. has been using the DDI heat Vitalix Inc. has been using the DDI heat

exchanger almost a year now with very positive exchanger almost a year now with very positive results. results. Raw molasses at 65% to 70% solidsRaw molasses at 65% to 70% solids is is running on one side and hot water on the other. running on one side and hot water on the other. We have had no problems with plugging We have had no problems with plugging or pressure build upor pressure build up. We are also very . We are also very pleased with the pleased with the effectiveness of this unit effectiveness of this unit in heat transferin heat transfer. Thank you for your help and . Thank you for your help and support.support.

Plant Mgr.  Doug OlsonPlant Mgr.  Doug Olson 308-762-8358308-762-8358 Vitalix Inc.Vitalix Inc. Alliance NEAlliance NE. .

Page 26: DDI-HeatExchangers Inc.  DDI Since 1980.

Pembroke Direct Sludge-to-Pembroke Direct Sludge-to-SludgeSludge

• From:From: David Atkinson David Atkinson Sent:Sent: September 7, 2007 11:23 AM September 7, 2007 11:23 AMTo:To: '[email protected]' '[email protected]'Subject:Subject: Letter of Reference Letter of Reference

•   • The Pembroke Pollution Control Centre is using the DDI Heat Exchanger with very The Pembroke Pollution Control Centre is using the DDI Heat Exchanger with very

positive results.  positive results.  Raw sludgeRaw sludge with an average temperature between 11* with an average temperature between 11*

C to 19* C flows through one side of the heat exchanger C to 19* C flows through one side of the heat exchanger and re-and re-circulated sludgecirculated sludge from the digesters with temperatures ranging in from the digesters with temperatures ranging in the high thirty’s flows through the opposite side of the heat exchanger.  This has the high thirty’s flows through the opposite side of the heat exchanger.  This has resulted in substantial savings as the resulted in substantial savings as the raw sludge is increased raw sludge is increased in temperature prior to entering the digesters in temperature prior to entering the digesters at no expense to the City sewage systemat no expense to the City sewage system..  After   After almost two years of operation no plugging has occurred and it works as per almost two years of operation no plugging has occurred and it works as per specification.  I am very satisfied with the results of this piece of equipment.  specification.  I am very satisfied with the results of this piece of equipment. 

•   • David AtkinsonDavid Atkinson• City of PembrokeCity of Pembroke• Utilities SuperintendentUtilities Superintendent• Office 613-735-6821 ext. 1490Office 613-735-6821 ext. 1490• Fax    613-732-7028 Fax    613-732-7028

Page 27: DDI-HeatExchangers Inc.  DDI Since 1980.

Doors opened after 8.5 Doors opened after 8.5 yearsyears

Page 28: DDI-HeatExchangers Inc.  DDI Since 1980.

The Gaskets after 8.5 YearsThe Gaskets after 8.5 Years

Page 29: DDI-HeatExchangers Inc.  DDI Since 1980.

Inside – Clean and without Inside – Clean and without damage after 8.5 yearsdamage after 8.5 years

Page 30: DDI-HeatExchangers Inc.  DDI Since 1980.

Viscosity Influence on required Viscosity Influence on required areaarea

Page 31: DDI-HeatExchangers Inc.  DDI Since 1980.

RepresentativesRepresentatives

Page 32: DDI-HeatExchangers Inc.  DDI Since 1980.
Page 33: DDI-HeatExchangers Inc.  DDI Since 1980.

LinksLinks

•Personnel (http://www.ddi-heatexchangers.com/resume.htm)

•Other Products(http://www.ddi-heatexchangers.com/other_products.htm)

DDI can supply Parker Boiler & Pumps DDI can supply Parker Boiler & Pumps tootoo

DDI has PIG CLEANING optionDDI has PIG CLEANING option

Page 34: DDI-HeatExchangers Inc.  DDI Since 1980.

Sample QuoteSample Quote

Page 35: DDI-HeatExchangers Inc.  DDI Since 1980.

Tulsa OK, Via Ashbrook and Tulsa OK, Via Ashbrook and HDRHDR

Page 36: DDI-HeatExchangers Inc.  DDI Since 1980.

Rialto- EnerTech via HDRRialto- EnerTech via HDR

11 Heat Exchangers- all phases.11 Heat Exchangers- all phases.

Page 37: DDI-HeatExchangers Inc.  DDI Since 1980.

Molasses with 65 % Molasses with 65 % SolidsSolids VitalixVitalix

Page 38: DDI-HeatExchangers Inc.  DDI Since 1980.

DDI HX and Boiler setDDI HX and Boiler set DDI in Pontiac with Boiler combined- DDI in Pontiac with Boiler combined- (Cover removed)(Cover removed)

Page 39: DDI-HeatExchangers Inc.  DDI Since 1980.

Building’s Sewage Heat Building’s Sewage Heat RecoveryRecovery

RECOVERING HEATRECOVERING HEAT from the Hot from the Hot liquids leaving the Suites (i.e. liquids leaving the Suites (i.e. SewageSewage with % Solidswith % Solids) at about ) at about 20-28 deg C. 20-28 deg C.

Directly to… Directly to…

Cold WaterCold Water entering the Building entering the Building before the Boiler, at about 2-10 before the Boiler, at about 2-10 deg C.deg C.

Page 40: DDI-HeatExchangers Inc.  DDI Since 1980.

Man-Hole Man-Hole (video on the web)(video on the web)

Page 41: DDI-HeatExchangers Inc.  DDI Since 1980.

Davit Arm – swings door in limited Davit Arm – swings door in limited spacespace

Page 42: DDI-HeatExchangers Inc.  DDI Since 1980.

DDI Logo - Final