Top Banner
DCPS Telecom DC Power Systems
12

DCPS - lamarchemfg.comweb.lamarchemfg.com/userfiles/brochures/Telecom-DC-Power-Systems.pdf · described below and in NEMA Standards Publication 250-2003, “Enclosures for Electrical

Mar 21, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: DCPS - lamarchemfg.comweb.lamarchemfg.com/userfiles/brochures/Telecom-DC-Power-Systems.pdf · described below and in NEMA Standards Publication 250-2003, “Enclosures for Electrical

DCPS Telecom DC Power Systems

Page 2: DCPS - lamarchemfg.comweb.lamarchemfg.com/userfiles/brochures/Telecom-DC-Power-Systems.pdf · described below and in NEMA Standards Publication 250-2003, “Enclosures for Electrical

1

About Us

Since 1945, La Marche has been providing reliable power conversion products. We are dedicated to the development and production of innovative quality products to meet our customer’s electrical power requirements. La Marche products include battery chargers, rectifiers, power supplies, inverters and others. We serve the Utility, Telecommunication, Engine Start, Material Handling, Railroad, Marine, and Mining markets.

La Marche integrated DC Power systems provide power needs for telecom, cable and microwave networks. For over 70 years, La Marche has delivered customized systems to suit any telecom application. La Marche DC power systems offer high reliability, high efficiency, high power density rectifiers, DC to DC converters, distribution centers, and supervisory modules.

THE POWERFUL

ADVANTAGE

RELIABILITY YOUCAN TRUST

CUSTOM SOLUTIONS TECHNOLOGY

U.S. COMPANY 24 HOUR SERVICE

Page 3: DCPS - lamarchemfg.comweb.lamarchemfg.com/userfiles/brochures/Telecom-DC-Power-Systems.pdf · described below and in NEMA Standards Publication 250-2003, “Enclosures for Electrical

DC Power Systems200 Amp

2

Custom Modular 200A - 800A Systems

Custom Modular High Power DC Systems

Complete and Stand Alone 200A SystemUp to 12kW @ -48Vdc Universal Rectifier AC InputController with Battery and Load Management and Protection Modes Alarm Dry Output and Input Contacts, and Sensor Inputs Web User Interface and SNMP Communication Protocol16 Pluggable Load Breakers and 2 Battery BreakersLVBD (Low Voltage Battery Disconnect)DC Surge ProtectionRack Mount; 4RU 19” or 23”

12kW – 48kW @ -48Vdc200 Amp @ -48Vdc Per Rectifier ShelfOne or Two 600A Distribution Tiers20 Breaker Positions per TierLow Voltage Disconnect (LVD) Contactor per TierUniversal Rectifier AC InputController with Battery and Load Management and Protection ModesAlarm Dry Output and Input Contacts, and Sensor InputsWeb User Interface and SNMP Communication ProtocolOpen Rack or NEMA rated EnclosuresBattery Trays with Disconnect Breakers

Up to 100kW systems200 Amp @ -48Vdc Per Rectifier Shelf600A per Tier for Distribution24 Breaker positions per TierLVD Contactors 23” Frame Enclosed Cabinet

Shown above: DCPS-4RU-200A

Shown above: 400A DC System Examples

400A Open Rack System

400A NEMA 4 System

Page 4: DCPS - lamarchemfg.comweb.lamarchemfg.com/userfiles/brochures/Telecom-DC-Power-Systems.pdf · described below and in NEMA Standards Publication 250-2003, “Enclosures for Electrical

DC Power System ComponentsDC Power System Components

3

La Marche offers Power Systems of multiple sizes of rectifiers, converters, inverters and feature loaded distribution panels (LVD, Ground/Charge Busbars, etc.)

Charge Busbarsand Ground Busbars

Distribution Center:• Plug-in Load Breakers• LVLD/LVBD

Control Unit:• System Controller with monitoring capabilities• Communication Ports• Alarm Contacts• Sensor Inputs

Power Equipment:• Rectifiers• Converters• Inverters

Breaker Panels:• Battery Disconnect Main Breakers• Load Disconnect Main Breakers

Battery Trays

Cabinets:• NEMA and IP Rated Enclosures• Seismic Relay Rack

Example Block Diagram

LOWVOLTAGE

DISCONNECT

Page 5: DCPS - lamarchemfg.comweb.lamarchemfg.com/userfiles/brochures/Telecom-DC-Power-Systems.pdf · described below and in NEMA Standards Publication 250-2003, “Enclosures for Electrical

ControllerController (DCSC)

La Marche’s DC System Controller (DCSC) is an intelligent module that monitors and manages La Marche DC power systems. The controller provides the system with Battery Management, Energy Conservation, Rectifier Management, Intelligent Battery Hibernation Mode, Battery Testing, Battery Charging, and Current Limiting controls.

System configuration settings and real-time parameters can be accessed either locally (through a two-line LCD display), or remotely (through a Web User Interface).

(1) Run Indicator(2) Minor Alarm Indicator(3) Major Alarm Indicator(4) Control Buttons(5) USB port

(6) RS485/RS232 Port(7) Handle(8) Locking Latch(9) Fast Ethernet (FE) Port(10) LCD

Controller Indicator Description

Indicator

Run Indicator

Minor AlarmIndicator

Major AlarmIndicator

Color Status

Green

Off

Steady OnOff

Red

Yellow

Description

Blinking at0.5 Hz

Blinking at 4 HzOff

Steady On

Controller OFF

Controller communicating properly

Controller ON but not communicating properly

No minor alarm(s)

Minor alarm(s) generated

No critical or major alarm(s)Critical or major alarm(s) generated

DCU I/O Interface Module

Equipped with the I/O module (DCU), the controller supports configurable digital inputs, alarm dry-contacts and site sensor ports for environment management and alarms reporting. The DCU I/O module provides the ability to add multiple sensors for: ambient temperature, humidity, water, door status, smoke and battery temperature. The dry-contacts alarm are configurable and can be customized upon the DC system’s requirements. All alarms can be easily configured and monitored remotely through the WebUI (Web User Interface).

DCU Port Description

Port Type Silk Screen DescriptionTEM-HUMWATERTEMP1TEMP2GATESMOKEBTEMPDIN1DIN2DIN3DIN4DIN5DIN6ALM1ALM2ALM3ALM4ALM5ALM6ALM7ALM8COM

Ambient Temp. and humidity sensorWater SensorAmbient Temperature Sensor 1Ambient Temperature Sensor 2Door Status SensorSmoke SensorBattery Temperature SensorDry Contact Input 1Dry Contact Input 2Dry Contact Input 3Dry Contact Input 4Dry Contact Input 5Dry Contact Input 6Dry Contact Output 1Dry Contact Output 2Dry Contact Output 3Dry Contact Output 4Dry Contact Output 5Dry Contact Output 6Dry Contact Output 7Dry Contact Output 8RS485 Port

Sensor Port

Dry Contact Input

NOTE: For details aboutthe signal definitions, see the power system user manual

Dry Contact Output

NOTE: For details aboutthe alarms associated with drycontact outputs, see the power system user manual

Communication Port

123

4

Page 6: DCPS - lamarchemfg.comweb.lamarchemfg.com/userfiles/brochures/Telecom-DC-Power-Systems.pdf · described below and in NEMA Standards Publication 250-2003, “Enclosures for Electrical

ControllerController Features

Mechanical

.

Grid Quality Detection Battery ManagementAC Input Voltage

AC Input Current

AC Frequency

DC Output Voltage

Total Load Current

Total Battery Current

Battery Current

Battery Temperature

Ambient Temperature

Rectifier Hibernation

Rectifier Operation Information

Rectifier Power-On/Off Control

Rectifier Output Voltage and Current Limit

Rectifier Overvoltage Protection

Sequential Rectifier Startup

Battery Hibernation

Battery Control

Battery Charging

Battery Test

Battery Current Limiting

Battery Temperature Compensation

Battery High Temperature Protection

Multi-Mode & Multi-Level Disconnecting Protection

Battery Imbalance Detection

Battery Capacity Calculation/Backup Time Calculation

Internal Fault

AC Phase Failure

AC/DC Overvoltage/Undervoltage

Load/Battery Fuse Break

Battery Discharging

Low Voltage Battery Disconnect (LVBD)

Battery Temperature High/Very High/Low/Very Low

Rectifier Failure

Rectifier Communication Failure

No Redundant Rectifiers

AC/DC Surge Protection Device (SPD) Failure

Energy Conservation Management

Rectifier Management

Alarm

Overall Dimensions: (W x D x H)

7.6” x 1.6” x 3.9”194.3 x 40.8 x 99mm

Grid Quality Detection

Weight: 3.3lb (1.5kg)

Natural Cooling

Low Voltage Load Disconnects (LVLD1, LVLD2)

The Controller is Hot Swappable

5

Page 7: DCPS - lamarchemfg.comweb.lamarchemfg.com/userfiles/brochures/Telecom-DC-Power-Systems.pdf · described below and in NEMA Standards Publication 250-2003, “Enclosures for Electrical

ControllerCommunication Ports

Web User Interface

The Web User Interface allows for a secure password protected remote access to the DC system for monitoring and control purposes. The WebUI provides system’s running parameters, active alarms and configurations. Various settings can be configured using the WebUI. Settings include: alarm parameters and configurations, rectifier management, battery management and communications settings.

The WebUI provides flexible alarm configuration settings that includes a PLC (Programmable Logic Controller) programming tool.

Communication Ports

FE port

RS485/RS232 port

Communication Parameter Communication Protocol

10/100M auto-adaptation

Baude rate: 9600 bit/s

HTTPS and SNMP

Master/slave protocols

NOTE: All ports are protected by a security mechanism.

6

Page 8: DCPS - lamarchemfg.comweb.lamarchemfg.com/userfiles/brochures/Telecom-DC-Power-Systems.pdf · described below and in NEMA Standards Publication 250-2003, “Enclosures for Electrical

RectifierRectifier (DCR)

3500

500

1000

1500

2000

3000

2500

40 50 55 65 75

100%80%60%40%20%

10098969492908886848280

The DCR50 rectifier converts AC power to DC power and delivers high performance features, such as high efficiency (>96%), high power density, walk-in start, complete protection and low noise. The output voltage of the rectifiers can be adjusted through the DC System controller. The rectifier is hot swappable, providing easy installation and maintenance.

High Efficiency Exceeds 96%

Universal AC Input

Operating Temperature Range: -40 to 65°C

Total Harmonic Distortion (THD): <5%

Hot Swappable

Communication Over CAN

Meets RoHS Requirements

TUV, CE, CB, UL Recognized

40

45

50

55

60

5 10 15 20 25 30 35 40 45 50 55 60 65

Output Feature

Efficiency Curve

Power Derating Curve

Current / A

Load Rate

Temperature/℃

Volta

ge/V

Pow

er/W

Features

7

Page 9: DCPS - lamarchemfg.comweb.lamarchemfg.com/userfiles/brochures/Telecom-DC-Power-Systems.pdf · described below and in NEMA Standards Publication 250-2003, “Enclosures for Electrical

RectifierRectifier Specifications

W eight ≤4.4lb (≤2kg)

Cooling

Forced Air Cooling

Input voltage 85-300 VAC

Frequency

45-66 Hz

Maximum input current

≤17A

Power factor

≥0.99

THD

≤5%

Output voltage

42-58 VDC, Nominal: 54 VDC

Output power

55A @ 54V (176-300 VAC)Linearly derated to 23A @ 54V (85-175 VAC)

Operating temperature

Storage temperature

Relative humidity

Altitude

Input overvoltage protection 300 VAC

Input undervoltage protection 80 VAC

Output overvoltage protection 58.5-60.5 VDC

Output short circuit protection

Over-temperature protection

MTBF

>500,000 hours

≤55dB (40℃, Full Load)

Safety certification

EMC

AC Input

Protection

Reliability

Safety/emc/Lightning Protection

Mechanical

DC Output

Environmental

Audible Noise

Overall Dimension(W x D x H)

4.1” x 11.1” x 1.6”105 x 281 x 40.8mm

5% - 95% (Non-Condensing)Up to 6,562ft (Derate Operating Temperature by 1°C/656ft for 6,562ft-13,123ft)

-40 to 65°C (-40 to 149°F), Derated Output Above 55°C (131°F)

-40 to 75°C (-40 to 167°F)

TUV, CE, UL UL60950-1IEC60950-1EN60950-1CAN/CSA C22.2 No. 60950-1 EN55022 Class BEN55024EN61000-3-2EN61000-3-3ETSI EN300 386ETSI EN301489ITU-T K.20

Lightning protection YD 5098-2005 5KA

Efficiency >96%

8

Page 10: DCPS - lamarchemfg.comweb.lamarchemfg.com/userfiles/brochures/Telecom-DC-Power-Systems.pdf · described below and in NEMA Standards Publication 250-2003, “Enclosures for Electrical

Other ComponentsDC Distribution

Battery Tray

La Marche Relay Rack Mounted Battery Trays are beneficial if floor space is confined and batteries are to be mounted directly in the DC power system equipment racks.

Battery Disconnects

Constructed from 12 Gauge Steel

ANSI-61 Gray Paint Finish

Assembly and Mounting Hardware

Welded Corners

600 lbs Weight Capacity

Available with Battery Disconnects

Features

Plug-In Breakers

Breaker Positions Required:

1A - 100A125A - 200A

= 1 Position= 2 Positions

Available Breaker Current Ratings1A, 2A, 3A, 5A, 10A, 15A, 20A, 25A, 30A, 35A, 40A, 50A, 60A, 70A, 80A, 100A, 125A, 150A, 200A

9

Highly Customizable Distribution

Positive Ground Detection

600A Distribution Tier with Plug-in Type Breakers

LVBD (Low Voltage Battery Disconnects)

LVLD (Low Voltage Load Disconnects)

Current Sensing

Load Breakers

Battery Breakers

Charge and Ground Busbars

Page 11: DCPS - lamarchemfg.comweb.lamarchemfg.com/userfiles/brochures/Telecom-DC-Power-Systems.pdf · described below and in NEMA Standards Publication 250-2003, “Enclosures for Electrical

EnclosuresEnclosure Information

La Marche Manufacturing offers Complete Power Systems; including Battery Chargers, Rectifiers, Converters, Inverters, Batteries and Distribution in Indoor and Outdoor Cabinets. La Marche Power Systems are available in multiple arrangements in order to meet different applications’ specific requirements. Cabinets are available in NEMA 1, NEMA 3(R), NEMA 4(X), NEMA 12 and IP ratings.

Different NEMA ratings provide different levels of protection against environmental conditions as described below and in NEMA Standards Publication 250-2003, “Enclosures for Electrical Equipment (1000 Volts Maximum)”.

NEMA 1 is a basic general purpose indoor enclosure designed to protect people from incidental contact with the components inside as well as a degree of protection against solid objects.

NEMA 3R is a basic outdoor enclosure designed to protect the enclosed equipment against rain. It provides protection against falling dirt, rain, sleet and snow.

NEMA 4 is a watertight and dust tight enclosure. It provides protection against falling dirt, windblown dust, rain, sleet, snow, splashing water and hose directed water. NEMA 4(X) provides protection against corrosion.

NEMA 12 is a dust tight and drip tight enclosure intended for indoor use. It provides protection against falling dirt, circulating dust, lint, fibers, and dripping water.

*NEMA 3R, 4 and 12 also provide protection for people against incidental contact with internal components.

Shown above: NEMA 4

Shown above: NEMA 4

Shown above: NEMA 3R

10

Page 12: DCPS - lamarchemfg.comweb.lamarchemfg.com/userfiles/brochures/Telecom-DC-Power-Systems.pdf · described below and in NEMA Standards Publication 250-2003, “Enclosures for Electrical

La Marche Mfg. (A U.S. Company) 106 Bradrock Drive, Des Plaines, IL 60018Tel: 001.847.299.1188Fax: [email protected]

La Marche DC Systems

Maintaining Power Across the Globe