Page 1: Datastream Installation Guide

DATASTREAM VERSION 5.1

Document Version 5.1 Date of issue: 20/05/2011

INSTALLATION GUIDE

Page 2: Datastream Installation Guide

Document Version 5.1 Date of issue: 20/05/2011

CONTENTS

1 Introduction 3

Target audience 3

What you will need 3

Supporting information 3

2 Installing datastream 4

Before you start 4

Installation rights and component registration 4

Datastream installation 4

Starting Datastream Launcher 4

New installation 6

Upgrading from earlier versions 12

Batch files 12

Installing using the Advance MSI file 12

Configuring communication settings 13

3 Installing OFFICE ADD-INS 14

Installing Datastream Advance for Office (AFO) Add-Ins 14

Installing the Microsoft Excel Add-In 14

Installing the Microsoft Word Add-In 15

Microsoft Office PowerPoint 2003 and previous versions 15

Installing the Datastream Charting Add-In manually (for Microsoft Office 2003 and later) 15

4 Uninstalling Datastream 16

5 Uninstalling Datastream Advance for Office (AFO) 17

6 Common problems and solutions 19

7 Datastream files 20

~DSSETUP.log 20

.adv files 20

AdvanceOffice.xla 20

AdvanceOffice.xlam 20

DS5REG.bat 20

AFOWord.dot 23

complete.bat 23

config.mdb 24

DSAFO5PP.ppa 24

ReadMe.txt 24

search.mdb 24

uninstall.bat 24

uct.mdb 25

Page 3: Datastream Installation Guide

© Copyright Thomson Reuters 2011 3

1 INTRODUCTION

This installation guide contains step-by-step procedures for installing Thomson Reuters Datastream

version 5.1 (“previously known as Advance”) and associated Add-Ins – Datastream Advance for Office

(AFO). This guide also describes how to uninstall the Datastream software.

The guide brings together in single, comprehensive document information previously published in

number of different locations.

TARGET AUDIENCE

This guide is aimed at technical teams who have experience of installation of a range of Windows

software, either using our installation program or a network roll out using a script.

WHAT YOU WILL NEED

An Datastream installation CD

Systems that meet the requirements defined in the technical facts on our Extranet at:

http://extranet.datastream.com/User%20Support/PubDoc/Advance.htm

If you are not already registered for the Datastream Extranet you will be prompted to do so.

Registration is free and available to all Datastream users.

The appropriate rights to install software on the target computer(s). See Installation rights and

component registration.

To run Datastream, an account on the Datastream central system with user ID and password and

the necessary data communications protocols and configuration settings.

SUPPORTING INFORMATION

You will find release notes on the Datastream Installation CD in the Readme.txt file.

The Datastream Extranet also contains a wealth of support information including hotfixes where these

are available. You can access the Datastream Extranet at: http://extranet.datastream.com

Page 4: Datastream Installation Guide

© Copyright Thomson Reuters 2011 4

2 INSTALLING DATASTREAM

BEFORE YOU START

Version 5.1 of Datastream is available only as a Windows Installer setup. Windows Installer is a

system service available as standard in Windows XP and later.

Note Any upgrades will require old versions of advance to be uninstalled. Refer Page 12 Upgrading from Previous Versions for more details.

If Windows Installer is not installed on your system, the Datastream installation program will ensure

that Windows Installer is correctly installed and configured before starting to install Datastream.

Windows Installer setup may require the system to be rebooted; normally the Datastream installation

program will be re-started automatically when the system restarts, but if it does not, restart it manually

and proceed with the Datastream installation. The installation has been tested with Windows Installer

versions up to and including 4.0.

INSTALLATION RIGHTS AND COMPONENT REGISTRATION

You will need the „right to install software‟, usually interpreted as „administrator rights‟. Datastream

must then be run once using those rights to register self registering controls. Thereafter Datastream

can be used by users with non-privileged rights, so that a user can run Datastream with user

permission after installation.

In addition:

Database and user folders must be set with read/write/create and delete rights because they hold

updateable files.

You will find details in the DS5_rights.xls file supplied on the Datastream Installation CD with each

version of Datastream.

The registry entries for Datastream 5.1 are available on the Extranet, including the entries created

when Datastream is first loaded and run, and when some other components are registered. You will

need to bear this in mind when creating a script to roll out Datastream centrally.

DATASTREAM INSTALLATION

The Datastream Launcher (setup.exe) starts automatically when you insert the CD into the drive and

enables you to initiate most common Datastream setups.

Starting Datastream Launcher

Insert the Datastream installation CD in the drive. The Datastream Launcher starts:

Page 5: Datastream Installation Guide

© Copyright Thomson Reuters 2011 5

You have the following options:

Full Install

Installs a full copy of Datastream onto the local PC.

Uninstall

Removes Datastream 5.1 from the local PC, but does not remove user created files and

configuration information.

Do not use this option for earlier versions of Datastream – use Control Panel to uninstall

previous versions of Datastream.

Release Notes

Release notes contains last minute information about the current release.

Installation Instructions

Browse CD

Enables you to examine the contents of the installation CD.

Online Customer Support

A link to the Datastream Extranet at http://extranet.datastream.com

Page 6: Datastream Installation Guide

© Copyright Thomson Reuters 2011 6

There are also two check boxes:

Quiet

To enable or disable quiet mode operation.

Logging

To record installation results and messages. The log is built in the system-defined TEMP folder in a

file called ~DSsetup.log. Subsequent installations append data to the log file and do not overwrite

it. If a Datastream installation fails, copy this file to another location and be ready to supply it to

support staff – it can provide many of the answers to questions support will have.

Before starting an installation, Datastream Launcher checks:

Operating system version and service pack level. If this is not sufficient to support Datastream, the

installation will abort.

Versions of some Windows system files. If these are not compatible with Datastream, the

installation will abort.

Running Office components.

New installation

1. From the Datastream Launcher click Full Install to this PC:

Page 7: Datastream Installation Guide

© Copyright Thomson Reuters 2011 7

Datastream displays the InstallShield Wizard dialog to guide you through the installation process:

2. Click Next. The InstallShield Wizard asks you to select the type of setup you want:

3. For first time installation click the Typical. This is the default.

The InstallShield Wizard gives you the option to change the default location for Datastream. If

you select to use default locations and options Datastream is installed in the folder:

Page 8: Datastream Installation Guide

© Copyright Thomson Reuters 2011 8

In XP:

c:\Program Files\datastream\datastream advance

In Vista/ Windows 7 (32) bit: Default installation will copy all the files to C:\Program Files\Datastream\Datastream Advance User and Database folders will be copied to C:\ProgramData\datastream\datastream advance

In Vista / Windows 7 (64) bit: Default installation will copy all the files to

C:\Program Files (X86)\Datastream\Datastream Advance\ User and Database folders will be copied to C:\Programdata\Datastream\datastream Advance\

Note Custom opinion installation can be used if user wants to customize his installation, like select features and change system drive for installation.

4. Click Next.

5. The InstallShield Wizard asks you to install Datastream shortcut, Graphic components,

Datastream Charting, SVG Viewer & Microsoft Office-2007/2010 Add-Ins automatically.

Page 9: Datastream Installation Guide

© Copyright Thomson Reuters 2011 9

Note If you have Office 2003 installed then InstallShield Wizard will not auto install AFO add-ins.

Note SVG Viewer option will be in disabled state if you have already installed it.

Note To install the Datastream Charting add-ins requires Microsoft's .NET framework (3.5), Office 2007 Primary Interop Assemblies (PIA) and Visual Studio Tools. For details see http://extranet.datastream.com/Products_Data/Servicepcks/Guidelines_for_installing_components%202.0.pdf. If these are not installed - please run the Datastream Charting Add-In.msi from the Datastream Charting Directory to install the Datastream Charting Add-in and you will be prompted to download and install these components.

Note With the Datastream Charting add-in there is an auto update facility (the default is to Always update to latest version) - for details see http://extranet.datastream.com/Products_Data/Servicepcks/Guidelines_for_installing_components%202.0.pdf

Note Datastream Charting Add-in will be installed always in „quite‟ mode, Refer ~DSSETUP.LOG for failed Add-In installation.

Choose the required options and click Next.

Page 10: Datastream Installation Guide

© Copyright Thomson Reuters 2011 10

6. Click Install. The InstallShield Wizard displays a progress indicator while the installation takes

place…:

Page 11: Datastream Installation Guide

© Copyright Thomson Reuters 2011 11

7. Click Finish. Datastream is now installed and can be launched from Start > Programs >

Datastream > Datastream 5.1 or use the Datastream 5.1 desktop shortcut.

Page 12: Datastream Installation Guide

© Copyright Thomson Reuters 2011 12

UPGRADING FROM EARLIER VERSIONS

Datastream 5.1 does not support upgrading from earlier version of Datastream Advance. You need to

uninstall the existing version from the Control Panel and then install Datastream 5.1.

Uninstalling Advance To uninstall Advance -

Remove the add-in from Excel - the best way to do this is to go to View > Toolbars > Customize.... leave this window open to the side and drag the AFO menu option out of the top area and drop it into the sheet area. Close the customise window then go to Tools > Add-ins and untick the advance office option from the list, ok the changes then close Excel.

Go to Control Panel > Add/Remove Programs and remove Advance from the list.

Search for these file extensions - *.OCA;*.TWD;*.EXD and delete any that refer to Datastream or DS.

Browse to C:\Program Files\Datastream\Datastream Advance and make a backup of the USER folder. Once done, delete the Datastream folder and its sub folders (C:\Program Files\Datastream).

Go into the registry and delete these keys and it‟s sub-keys - o Delete HKEY_CURRENT_USER\software\Datastream o Delete HKEY_LOCAL_MACHINE\software\Datastream o Delete HKEY_USERS\.DEFAULT\software\Datastream

Once this has been completed, reboot the machine then re-install Advance. Run the Adv5reg.bat file after this to ensure that all the DS components are correctly registered. In Excel, insert the AFO add-in but use the browse option (xla located in C:\Program Files\Datastream\Datastream Advance) instead of using the one already in the add-in list.

Batch files

To help you with smaller scale roll-outs and also to illustrate the syntax of some install and uninstall

commands, three batch files are supplied on the installation CD in the setup folder:

DS5reg.bat

Can be used to manually register all Datastream components. You should not need to use this

under normal circumstances.

complete.bat

Can be used to invoke silent setup of all components on a workstation from an administrator‟s

copy held on a server, with logging.

uninstall.bat

Can be used to uninstall a local copy of Datastream, with logging.

The content of these files is reproduced in 6 Datastream files.

Installing using the Advance MSI file

We supply the Advance.msi file to use within a scripting package such as SMS. However, this does

not perform some critical install checks such as:

Microsoft Office or Internet Explorer version.

Removal of previous Add-In.

Removal of *.twd, *.exd, *.oca files. The retention of these files from a previous installation of

Datastream can lead to errors appearing in Excel, PowerPoint and Word.

Page 13: Datastream Installation Guide

© Copyright Thomson Reuters 2011 13

Configuring communication settings

1. Launch Datastream from the Start menu:

Start > Programs > Datastream > Datastream 5.1

2. Select Tools > Configure Communications.

3. Select the Communications tab.

4. Set Device to TN3270.

5. Click Config.

6. Ensure that the TN3270 configuration dialog shows the default settings:

i. Host: SOURCE.DATASTREAM.COM

ii. Port: 23

iii. Use RAS: unchecked (the box is clear)

iv. Script setting are blank

7. Click OK to close the TN3270 configuration dialog.

Note User can use other device like DSGate or PAD / PAD Dialup.

8. Click OK to close the Datastream configuration dialog.

Page 14: Datastream Installation Guide

© Copyright Thomson Reuters 2011 14

3 INSTALLING OFFICE ADD-INS

INSTALLING DATASTREAM ADVANCE FOR OFFICE (AFO) ADD-INS

Datastream Advance For Office (AFO) gives you access to many Datastream facilities from within

Microsoft Office applications. AFO functionality is delivered through a set of Add-Ins for Excel, Word,

and PowerPoint, supplied with Datastream. In addition to Datastream you will need to have Microsoft

Office XP or later installed.

The Office 2003 Add-Ins is copied to the default Datastream folder as part of Datastream installation

and need to be selected from within the Office application. And if you have Office 2007 / 2010

installed, you can either install the add-ins automatically during installation or select them from within

Excel / Word / PowerPoint after installation.

Note Auto install of Add-In is only for Excel & PowerPoint 2007/2010.

When you have installed Datastream follow the relevant section below to start using AFO.

Installing the Microsoft Excel Add-In

There are three ways to add the Datastream for Office Add-In to Excel.

Microsoft Office 2003 and previous versions

This method loads the AdvanceOffice.xla each time you run Excel, making the Datastream for Office

facilities always available from the Datastream menu. To select this method:

1. Run Excel from the Windows Start menu.

2. Select Add-Ins... from the Tools menu. The Add-ins dialog is displayed.

3. Click the Browse button and navigate to the Datastream Advance directory, select

AdvanceOffice.xla, and click OK.

4. Click the Datastream Office check box.

5. Click OK.

Microsoft Office 2007 and later users (who installed the add-ins automatically)

1. This method loads the AdvanceOffice.xlam each time you run Excel, making the Datastream for

Office and Datastream Charting for Office facilities available from the Datastream menu. To

select this method:

2. Run the Datastream installation program.

3. Check the Excel box when asked whether you want to install add-ins automatically.

4. Complete the Datastream installation process.

On opening Excel Datastream is available as a ribbon in Excel-2007.

Microsoft Office 2007 and later users (who haven’t installed the add-ins automatically)

1. Run Excel from the Windows Start menu.

2. Click the Office button in Excel-2007. The File menu is displayed.

Page 15: Datastream Installation Guide

© Copyright Thomson Reuters 2011 15

3. Click the Excel Options button. The Excel Options dialog is displayed.

4. Select the Add-Ins option on the left hand side. The Add-Ins dialog is displayed.

5. Select Excel Add-Ins from the Manage drop-down list.

6. Click the Go button. The Add-Ins dialog is displayed.

7. Click the Browse button and navigate to the Datastream Advance directory (most commonly

C:\Program Files\Datastream\Datastream Advance), select AdvanceOffice.xlam, and click OK.

8. Click the Advance Office 2007 check box.

9. Click OK.

After you load the AdvanceOffice.xlam add-in, Datastream is available as a ribbon in Excel-2007.

Installing the Microsoft Word Add-In Microsoft Office Word 2003 and 2007

1. Navigate to the Datastream Advance folder. By default this is „\Program

Files\Datastream\Datastream Advance‟.

2. Copy the AFOWord.dot from Datastream Advance folder to the Office Startup folder.

Office 2003 Startup path is „\Program Files\Microsoft Office\Office\Startup‟

Office 2007 Startup path is „\Program Files\Microsoft Office\Office\ Office12\Startup‟

The Word Add-In is now installed and you will see the Datastream menu option on the main Word

menu bar.

Installing the Microsoft PowerPoint Add-In

Microsoft Office PowerPoint 2003 and previous versions

1. Following Datastream installation, open PowerPoint

2. Select Tools > Add-Ins…

3. In the Add-Ins dialog click Add New…

4. In the Add New PowerPoint Add-In dialog navigate to the folder holding Datastream. By default

this is \Program Files\Datastream\Datastream Advance.

5. Select the PowerPoint Add-In DSAFO5PP.ppa and click OK.

6. The Add-In is displayed in the Add New PowerPoint Add-In dialog. Click OK.

The PowerPoint Add-In is now installed and you will see the Datastream menu option on the main

PowerPoint menu bar. Use this menu to select AFO facilities from within PowerPoint.

Installing the Datastream Charting Add-In manually (for Microsoft Office 2003 and later)

Insert the Datastream installation CD in the drive, the Datastream Launcher starts:

1. Click Browser CD, open Datastream Charting folder

2. Double click “Datastream Charting Add-In.msi”

3. InstallShield Wizard dialog is displayed.

4. Go through the installation process.

Page 16: Datastream Installation Guide

© Copyright Thomson Reuters 2011 16

4 UNINSTALLING DATASTREAM

You can uninstall Datastream by using:

The uninstall option from the setup utility. You can only use this option for the supplied version of

Datastream with setup.exe; it will not work for earlier versions of Datastream.

The recommended way to uninstall Datastream is by using the Remove option from Windows

Control Panel > Add or Remove Programs as you can use this option for all versions of

Datastream.

Both of the options above uninstall the Datastream application, but they do not remove User

created files and configuration details from:

Windows XP: C:\Program Files\Datastream\Datastream Advance

Windows Vista\ Windows 7: C:\Programdata\Datastream\Datastream Advance

User created files, including project files (.adv extension), list files (.llt extension), and other files

such as graphics schemes (.csc extension).

config.mdb

Holds information on the preferences for interface options set by the user.

search.mdb

Holds the user‟s equity searches.

uct.mdb

Holds the user‟s favourites.

Setup log (~DSsetup.log)

Registry entries:

HKEY_CLASSES_ROOT: the .adv file association

HKEY_CURRENT_USER/Software/Datastream/DSAccess: user communications settings

HKEY_CURRENT_USER/Software/Datastream/Datastream Advance: entries created by

Advance

HKEY_LOCAL_MACHINE/SOFTWARE/Datastream/Datastream Advance: version entries

Uninstallation of Datastream will not uninstall Datastream Charting and SVG viewer. You can use

Control Panel > Add or Remove Programs for uninstallation.

Do not attempt to uninstall Datastream by deleting the Datastream directory – this can leave your

system in an unstable state.

When UAC is on in Vista and Windows 7 (64) bit the virtualization comes into act and to facilitate the

changes the registry entries are also copied to the following path.

HKEY_CLASSES_ROOT\VirtualStore\MACHINE\SOFTWARE\Wow6432Node\Datastream\Datas

tream Advance\Version

HKEY_CURRENT_USER\Software\Classes\VirtualStore\MACHINE\SOFTWARE\Wow6432Node\

Datastream\Datastream Advance\Version

Note Although upgrading Datastream should preserve your existing settings, taking backups before you upgrade enables you to recover settings in the event of an unsuccessful upgrade.

Page 17: Datastream Installation Guide

© Copyright Thomson Reuters 2011 17

5 UNINSTALLING DATASTREAM ADVANCE FOR OFFICE (AFO)

Remove the following registry entries:

From:

HKEY_LOCAL_MACHINE\SOFTWARE\Datastream\Datastream Advance\Office

HKEY_USERS\.DEFAULT\Software\Datastream\Datastream Advance\Office

AdvanceInstallationCheckFile

AFOSamplesDownloadPath

AFOSamplesURL

AFOSamplesXMLPath

AutoRefresh_Default

DisplayDataType_Default

DisplayExpression_Default

Editor

Editorcall

EmbedInsert_Default

EnableTriggering

ExpressionPicker_Launch

ExpressionPicker_Path

FastLoad_Default

FunctionPicker

GrpIndex

IgnoreChartSheets

InjectAdvanceVerifierCode

Intellisense

LastValueFirst

LinkToMetadata_Default

ListMemberTimeSeriesConfirm

NA_DEFAULT

NavPreload

RefreshButton_Default

ReqTable_SwitchFocusOnSave

sCurrentUserStat

SearchId

SpecialDatatype

VBTrustAlert

VerionInfoProvider

From:

HKEY_CURRENT_USER\Software\Datastream\Datastream Advance\Office

Page 18: Datastream Installation Guide

© Copyright Thomson Reuters 2011 18

Del_AutoCorrect_3Dots

EditExpression_Warning

REQUEST_TABLE_PATH

Row_Default

SeriesSelCategory

Set_T1Code

Set_T1Code_Static

Set_T1Code_TimeSeries

ShortCutMenu_Default

SuppressComments

T1Code_Default

Transpose_Default

UCTS_REQUEST_TABLE_PATH

WindowsHandle

Wizard_AutoSave

Wizard_RCAsDefault

Note All entries available in HKEY_USERS are also valid here.

Page 19: Datastream Installation Guide

© Copyright Thomson Reuters 2011 19

6 COMMON PROBLEMS AND SOLUTIONS

The Datastream Extranet gives you access to a downloadable document containing frequently asked

questions and answers connected with Datastream installation. Go to:

http://extranet.datastream.com/Products_Data/Servicepcks/installations.htm

Page 20: Datastream Installation Guide

© Copyright Thomson Reuters 2011 20

7 DATASTREAM FILES

This chapter provides brief descriptions of the most important files supplied with or created by

Datastream version 5.1.

~DSSETUP.LOG

A logging file created in the TEMP directory defined by your system. This file contains details

of each Datastream installation you attempt on your system, with each subsequent installation

appending information to the end of the file. If a Datastream installation fails, copy this file to

another location and be ready to supply it to support staff – it can provide many of the answers

to questions support will have.

.ADV FILES

Datastream project files created by users. By default .adv files are saved to the Program

Files\datastream\datastream advance\User folder.

ADVANCEOFFICE.XLA

The Datastream Advance for Office 2003 and previous versions Excel Add-In is supplied on

the Datastream Installation CD.

ADVANCEOFFICE.XLAM

The Datastream Advance for Office 2007 and later Excel Add-In is supplied on the Datastream

Installation CD.

DS5REG.BAT

A batch file supplied for reference. It can be used to manually register all Datastream

components but should not be needed during a normal installation. The content of the file is:

@ECHO OFF

ECHO.

ECHO Registering Datastream components

ECHO #################################

ECHO.

rem manual registration of datastream 5.1

rem the next two lines must be set to where the files have been installed...

c:

cd "\program files\datastream\datastream advance"

rem register tlb for sign and safe the controls

REGTLIB OBJSAFE.TLB

Page 21: Datastream Installation Guide

© Copyright Thomson Reuters 2011 21

rem API...

REGSVR32 /s DSAPICOMCLT.DLL

REGSVR32 /s COMSERVERPS.DLL

REGSVR32 /s ImgX61.dll

REGSVR32 /s ImgXCapture61.dll

REGSVR32 /s ImgXDialog61.dll

REGSVR32 /s ImgXPrint61.dll

REGSVR32 /s ImgXTwain61.dll

rem Datastream...

REGSVR32 /s DSAAfoSamples.ocx

REGSVR32 /s DSAUCIManager.dll

REGSVR32 /s DSAOSOFFVER.dll

REGSVR32 /s DSAHTTP.dll

REGSVR32 /s DSALocalList.DLL

REGSVR32 /s DSAChart.dll

REGSVR32 /s DSAList.dll

REGSVR32 /s DSTimers.DLL

REGSVR32 /s DSAReport.dll

REGSVR32 /s DSOnline2.dll

REGSVR32 /s DSARptFormatter.dll

REGSVR32 /s DSAReport.dll

REGSVR32 /s DSASearch.dll

REGSVR32 /s DSData.dll

REGSVR32 /s XLDATA.DLL

REGSVR32 /s DSParser.dll

REGSVR32 /s DSARegistry.DLL

REGSVR32 /s DSFormatters32.dll

REGSVR32 /s ASyncRequestProxy.dll

regsvr32 /s DSRemoteCodes.OCX

REGSVR32 /s dsamigration.dll

REGSVR32 /s dataset.dll

REGSVR32 /s dsanavigator.ocx

REGSVR32 /s dsacodex.dll

REGSVR32 /s KEYSTA32.OCX

REGSVR32 /s MSOUTL32.OCX

REGSVR32 /s SSCALA32.OCX

REGSVR32 /s sstabs32.ocx

Page 22: Datastream Installation Guide

© Copyright Thomson Reuters 2011 22

REGSVR32 /s SSTree.ocx

REGSVR32 /s Tab32x20.ocx

REGSVR32 /s Tab32x30.ocx

REGSVR32 /s tdbg5.ocx

REGSVR32 /s THREED32.OCX

REGSVR32 /s VCF15.ocx

REGSVR32 /s VsVIEW3.ocx

REGSVR32 /s Richtx32.ocx

REGSVR32 /s AFOPowerPoint.OCX

REGSVR32 /s AFOChart.ocx

REGSVR32 /s AnnotationControl.ocx

REGSVR32 /s DSAFOData.ocx

REGSVR32 /s DSAList.dll

REGSVR32 /s DSAChart.dll

REGSVR32 /s MDRAW32p.OCX

REGSVR32 /s DSRemoteCodes.OCX

regsvr32 /s DSIntellisense.ocx

REGSVR32 /s DSAFO32Editor.ocx

REGSVR32 /s DSAFO32.ocx

REGSVR32 /s GABrowserControl.ocx

REGSVR32 /s AFOWord.ocx

REGSVR32 /s DSAListFormatCode.dll

REGSVR32 /s DSChartControls.ocx

REGSVR32 /s NavSerPicker.ocx

rem AFO...

REGSVR32 /s AFOChart.ocx

REGSVR32 /s DSAChart.dll

REGSVR32 /s AnnotationControl.ocx

REGSVR32 /s XLDATA.DLL

REGSVR32 /s DSADataTypesFinder.DLL

REGSVR32 /s DSACodeFinder.DLL

REGSVR32 /s DSAListViewer.DLL

REGSVR32 /s DSAFormatCodeLookUp.DLL

REGSVR32 /s DSAExpressionPicker.dll

REGSVR32 /s DSAConvertDDE.dll

REGSVR32 /s DSCAFormats.dll

REGSVR32 /s DSAMigration.dll

Page 23: Datastream Installation Guide

© Copyright Thomson Reuters 2011 23

REGSVR32 /s DSExpressionBuilder.dll

REGSVR32 /s DSListWizard.ocx

REGSVR32 /s DSAFutOptPicker.dll

REGSVR32 /s DSAListWizard.dll

rem Registering Datastream T1 components

REGSVR32 /s DSSMCommon.dll

REGSVR32 /s DSNavPowerSearchClient.dll

REGSVR32 /s DSSMServer.dll

REGSVR32 /s DSSymbolMappingClient.dll

REGSVR32 /s RDCEnumerationWrapper.dll

REGSVR32 /s DSAdvanceProxy.ocx

REGSVR32 /s DSNavigatorUtils.dll

rem out-of-proc servers...

DSAChart2.EXE /regserver

DSAFOController32.EXE /regserver

dsapicomsvr.exe /regserver

DSConServer.exe /regserver

DSMonitor32.EXE /regserver

DSAUCIManagerEXE.exe /regserver

Advance32.EXE /regserver

ECHO.

ECHO Finished registering components

pause

AFOWORD.DOT

The Datastream for Office Word Add-In supplied on the Datastream Installation CD.

COMPLETE.BAT

A batch file provided for reference. It can be used to invoke silent setup of all components on a

workstation from an administrator‟s copy held on a server, with logging. The content of the file

is:

@ECHO OFF

ECHO.

ECHO Installing Datastream 5.1 on your computer

ECHO ##########################################

ECHO.

Page 24: Datastream Installation Guide

© Copyright Thomson Reuters 2011 24

rem will invoke silent setup (complete) from admin copy on server, with logging...

set SRC="<serverPath>\Advance.msi"

set TGT="c:\program files\datastream\datastream advance"

set LOG="c:\~DSsetup.log"

rem Microsoft Office 2007 & above users, run the below command for the auto installation of

excel and powerpoint addins where PARAM1,PARAM2 can accept "TRUE"or"FALSE".

rem msiexec /i %SRC% EXCELADDIN="PARAM1" PPTADDIN="PARAM2" /q /leucmo+

%LOG% INSTALLDIR=%TGT% INSTALLLEVEL=100

msiexec /i %SRC% /q /leucmo+ %LOG% INSTALLDIR=%TGT% INSTALLLEVEL=100

ECHO Datastream 5.1 succesfully installed

ECHO ####################################

ECHO.

pause

CONFIG.MDB

A database file containing configuration details including the user‟s preferences for interface

options created during the installation process.

DSAFO5PP.PPA

The Datastream for Office PowerPoint Add-In supplied on the Datastream Installation CD.

README.TXT

Contains last minute information provided by the Datastream Development team, includes all

known issues and workarounds.

SEARCH.MDB

A database file created to hold the user‟s equity searches.

UNINSTALL.BAT

A batch file provided for reference. It can be used to uninstall a local copy of Datastream, with

logging. The content of the file is:

@ECHO OFF

@ECHO OFF

ECHO.

ECHO Removing Datastream 5.1 from your computer

Page 25: Datastream Installation Guide

© Copyright Thomson Reuters 2011 25

ECHO ##########################################

ECHO.

rem will uninstall local setup , with logging...

set SRC="<serverPath>\Advance.msi"

set LOG="c:\~DSsetup.log"

msiexec /x %SRC% /qn /leucmo+ %LOG%

ECHO Datastream 5.1 succesfully removed from your computer

ECHO #####################################################

ECHO.

pause

UCT.MDB

A database file created to hold the user‟s favourites.

Page 26: Datastream Installation Guide

© 2011 Thomson Reuters. All rights reserved. Republication or redistribution of Thomson Reuters content, including by framing or similar means, is prohibited without the prior written consent of Thomson Reuters. 'Thomson Reuters' and the Thomson Reuters logo are registered trademarks and trademarks of Thomson Reuters and its affiliated companies.