Description – Overload protection – trip class 10 – Phase loss sensitivity – Disconnect function – Temperature compensation from -25 … +60 °C – Adjustable current setting for overload protection – Suitable for three- and single-phase application – Trip-free mechanism – Status indication for short-circuit trip – Clear switch position indication ON/OFF/TRIP – Lockable handle Order data MS132 screw terminal Setting range A Type Trip class Order code Pack- ing unit PCE Weight per PCE kg 0.10...0.16 MS132-0.16 10 1SAM350000R1001 1 0.215 0.16...0.25 MS132-0.25 10 1SAM350000R1002 1 0.215 0.25...0.40 MS132-0.4 10 1SAM350000R1003 1 0.215 0.40...0.63 MS132-0.63 10 1SAM350000R1004 1 0.215 0.63...1.00 MS132-1.0 10 1SAM350000R1005 1 0.215 1.00...1.60 MS132-1.6 10 1SAM350000R1006 1 0.265 1.60...2.50 MS132-2.5 10 1SAM350000R1007 1 0.265 2.50...4.00 MS132-4.0 10 1SAM350000R1008 1 0.265 4.00...6.30 MS132-6.3 10 1SAM350000R1009 1 0.265 6.30...10.0 MS132-10 10 1SAM350000R1010 1 0.265 8.00...12.0 MS132-12 10 1SAM350000R1012 1 0.310 10.0...16.0 MS132-16 10 1SAM350000R1011 1 0.310 16.0...20.0 MS132-20 10 1SAM350000R1013 1 0.310 20.0...25.0 MS132-25 10 1SAM350000R1014 1 0.310 25.0...32.0 MS132-32 10 1SAM350000R1015 1 0.310 Note: MS132 with pre-assembled auxiliary contact HKF1-11, please order as follow 1SAM350005Rxxxx Manual motor starters are electro- mechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less against short-circuit, overload and phase failures. Fuse less protection with a manual motor starter saves costs, space and ensures a quick reaction under short- circuit condition, by switching off the motor within milliseconds. Fuse less starter combinations are setup together with contactors. Manual motor starter MS132 Data sheet 2CDC241003V0013
12
Embed
Data sheet Manual motor starter MS132 - ABB Group...motor starter saves costs, space and ensures a quick reaction under short-circuit condition, by switching off the motor within milliseconds.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Description – Overload protection – trip class 10 – Phase loss sensitivity – Disconnect function – Temperature compensation from -25 … +60 °C – Adjustable current setting for overload protection – Suitable for three- and single-phase application – Trip-free mechanism – Status indication for short-circuit trip – Clear switch position indication ON/OFF/TRIP – Lockable handle
Note: MS132 with pre-assembled auxiliary contact HKF1-11, please order as follow 1SAM350005Rxxxx
Manual motor starters are electro-mechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less against short-circuit, overload and phase failures. Fuse less protection with a manual motor starter saves costs, space and ensures a quick reaction under short-circuit condition, by switching off the motor within milliseconds. Fuse less starter combinations are setup together with contactors.
Manual motor starter MS132Data sheet
2CD
C24
1003
V00
13
2 - 2CDC131021D0202
Functional description2C
DC
2420
33F0
013
1
2
3
4
5
6
7
1 Terminals 1L1, 3L2, 5L3
2 Switch position TRIP
3 Lockable handle
4 Test function
5 Status indication for short-circuit
6 Current setting range / Adjustable current setting for overload protection
7 Terminals 2T1, 4T2, 6T3
Application
The manual motor starters protect the load and the installation against short-circuit and overload. They are three pole protection devices with thermal tripping elements for overload protection and electromagnetic tripping elements for short-circuit protection. Furthermore, they provide a disconnect function for safely isolation of the installation and the supply and can be used for the manual switching of loads.
The manual motor starters have a setting scale in amperes, which allows the direct adjusting of the device without any additional calculation. In compliance with international and national standards, the setting current is the rated current of the motor and not the tripping current (no tripping at 1.05 x I, tripping at 1.2 x I; I = setting current).
Operation mode
2CD
C24
2023
F000
9
Single-phase operation
2CD
C24
2028
F001
3
Single-phase operation
2CD
C24
2024
F000
9
Three-phase operation
Wiring diagram
1L1 3L2 5L3
2T1 4T2 6T3
2CD
C24
2025
F000
9
2CDC131021D0202 - 3
Resistance and power loss per pole
Type Setting range Resistance per pole Power loss per pole
Intermittent periodic duty, ta: Motor starting time
4 - 2CDC131021D0202
Dimensions
in mm / inches
1.3
8"
0.1
"
3.5
4"
2.9
5"
0.22" 0.06"
0.55"
1.77"
0.55"
2.85"
3.2"
1.71"
1.7
7"
35
1.7
90
75
5.51.5
14
45
14
72.4
81.25
43.5
45"
2CD
C24
2015
F000
9
MS132 ≤ 10 A
0.06" 0.22" 0.22"
2.84"
3.19"
0.1"
3.85
"
1.77
"
0.55" 0.55"
1.77"
2.95
"
1.38
"
1.5 5.5 43.3
72.2
81.05
1.7
97.8
45
14 14
45
75
35
2CD
C24
2016
F000
9
MS132 > 10 A
0.35"Ø 0.18" 0.21"
4.3
3"
4.8
"
0.69"
9 Ø 4.5 5.4
110
122
17.5
2CD
C24
2017
F000
9
MS132 ≤ 10 A with screw fixing kit FS116 (accessory)
0.21"0.35" Ø 0.18"
4.33
"
4.8"
0.69"
2CD
C24
2018
F000
9
MS132 > 10 A + with screw fixing kit FS116 (accessory)
2CDC131021D0202 - 5
Technical data IEC/EN
Data at TA = 40 °C and at rated values, if nothing else indicated
Main circuit
1L1-3L2-5L3
2T1-4T2-6T3
Rated operational voltage Ue 690 V AC250 V DC
Setting range - thermal overload protection see table “Order data” on page 1Rated operational current Ie see table belowRated operational current DC-5 Ie
3 conducting paths in series up to 250 V
see “Rated operational current Ie”
Rated instantaneous short-circuit current setting Ii see table belowRated service short-circuit breaking capacity Ics see table “Short-circuit breaking capacity and
back-up fuses” on page 7Rated ultimate short-circuit breaking capacity Icu
Rated service short-circuit breaking capacity DC Ics
3 conducting paths in series up to 250 V
10 kA
Trip class see table “Order data” on page 1Rated frequency DC, 50/60 HzNumber of poles 3Resistance per pole see table “Resistance and power loss per pole”
on page 3Power loss per pole
Isolation data
Rated impulse withstand voltage Uimp 6 kV
Rated insulation voltage Ui 690 V
Pollution degree 3
Electrical connection MS132 ≤ 10 A MS132 ≥ 12 A
Connecting capacity solid 1/2 x 1 ... 4 mm² 1/2 x 1 ... 2.5 mm²
1/2 x 2.5 ... 6 mm²
stranded 1/2 x 1 ... 4 mm² 1/2 x 1 ... 6 mm²
1/2 x 2.5 ... 6 mm²
flexible with ferrule 1/2 x 0.75 ... 2.5 mm² 1/2 x 0.75 ... 6 mm²
flexible with ferrule insulated 1/2 x 0.75 ... 2.5 mm² 1/2 x 0.75 ... 6 mm²
flexible without ferrule 1/2 x 0.75 ... 2.5 mm² 1/2 x 1 ... 2.5 mm²
1/2 x 2.5 ... 6 mm²
Stripping length 9 mm 10 mm
Tightening torque 0.8 ... 1.2 Nm 2 Nm
Recommended screw driver M3.5 M4
Type Rated instantaneous short-circuit current setting li
You can find the address of your local sales organization on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems
Contact us
Note:We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.
We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB AG.