Description – Short-circuit protection – Disconnect function – Suitable for three- and single-phase application – Trip-free mechanism – Clear switch position indication ON/OFF/TRIP – Lockable handle Order data MO132 screw terminal Rated operational current A Type Trip class Order code Pack- ing unit PCE Weight per PCE kg 0.16 MO132-0.16 - 1SAM360000R1001 1 0.215 0.25 MO132-0.25 - 1SAM360000R1002 1 0.215 0.40 MO132-0.4 - 1SAM360000R1003 1 0.215 0.63 MO132-0.63 - 1SAM360000R1004 1 0.215 1.00 MO132-1.0 - 1SAM360000R1005 1 0.215 1.60 MO132-1.6 - 1SAM360000R1006 1 0.265 2.50 MO132-2.5 - 1SAM360000R1007 1 0.265 4.00 MO132-4.0 - 1SAM360000R1008 1 0.265 6.30 MO132-6.3 - 1SAM360000R1009 1 0.265 10.0 MO132-10 - 1SAM360000R1010 1 0.265 12.0 MO132-12 - 1SAM360000R1012 1 0.310 16.0 MO132-16 - 1SAM360000R1011 1 0.310 20.0 MO132-20 - 1SAM360000R1013 1 0.310 25.0 MO132-25 - 1SAM360000R1014 1 0.310 32.0 MO132-32 - 1SAM360000R1015 1 0.310 Manual motor starters magnetic only are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less against short- circuit. Fuse less protection with a manual motor starter saves costs, space and ensures a quick reaction under short- circuit condition, by switching off the motor within milliseconds. Fuse less starter combinations are setup together with contactors and overload relays. Manual motor starter magnetic only MO132 Data sheet 2CDC241009S0011
9
Embed
Data sheet Manual motor starter magnetic only MO132 · Order code Pack-ing unit PCE Weight per PCE kg 0.16 MO132-0.16 - 1SAM360000R1001 1 0.215 ... Rated ultimate short-circuit breaking
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Description – Short-circuit protection – Disconnect function – Suitable for three- and single-phase application – Trip-free mechanism – Clear switch position indication ON/OFF/TRIP – Lockable handle
Manual motor starters magnetic only are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less against short-circuit. Fuse less protection with a manual motor starter saves costs, space and ensures a quick reaction under short-circuit condition, by switching off the motor within milliseconds. Fuse less starter combinations are setup together with contactors and overload relays.
Manual motor starter magnetic only MO132Data sheet
2CD
C24
1009
S00
11
2 - 2CDC131035D0202
Functional description2C
DC
2420
34F0
013
1
2
3
4
5
1 Terminals 1L1, 3L2, 5L3
2 Switch position TRIP
3 Lockable handle
4 Test function
5 Terminals 2T1, 4T2, 6T3
Application
The manual motor starters magnetic only protect the load and the installation against short-circuit. They are three pole protection devices with electromagnetic tripping elements for short-circuit protection. Furthermore, they provide a disconnect function for safely isolation of the installation and the supply and can be used for the manual switching of loads.
For overload protection of the motors, an appropriate thermal or electronic overload relays must be used.
MO132 ≤ 10 A with screw fixing kit FS116 (accessory)
0.21"0.35" Ø 0.18"
4.33
"
4.8"
0.69"
5.49 Ø 4.5
110
122
17.5
2CD
C24
2008
F001
1
MO132 > 10 A + with screw fixing kit FS116 (accessory)
4 - 2CDC131035D0202
Technical data IEC/EN
Data at TA = 40 °C and at rated values, if nothing else indicated
Main circuit
1L1-3L2-5L3
2T1-4T2-6T3
Rated operational voltage Ue 690 V AC-
Rated operational current Ie see table belowRated operational current DC-5
3 conducting paths in series up to 250 V
-
Rated instantaneous short-circuit current setting Ii see table belowRated service short-circuit breaking capacity Ics see table “Short-circuit breaking capacity and back-
up fuses” on page 6Rated ultimate short-circuit breaking capacity Icu
Rated frequency 50/60 HzNumber of poles 3Power loss per pole see table “Power loss per pole” on page 3
Isolation data
Rated impulse withstand voltage Uimp 6 kV
Rated insulation voltage Ui 690 V
Pollution degree 3
Electrical connection MO132 ≤ 10 A MO132 ≥ 12 A
Connecting capacity solid 1/2 x 1 ... 4 mm² 1/2 x 1 ... 2.5 mm²
1/2 x 2.5 ... 6 mm²
stranded 1/2 x 1 ... 4 mm² 1/2 x 1 ... 6 mm²
1/2 x 2.5 ... 6 mm²
flexible with ferrule 1/2 x 0.75 ... 2.5 mm² 1/2 x 0.75 ... 6 mm²
flexible with insulated ferrule 1/2 x 0.75 ... 2.5 mm² 1/2 x 0.75 ... 6 mm²
flexible without ferrule 1/2 x 0.75 ... 2.5 mm² 1/2 x 1 ... 2.5 mm²
1/2 x 2.5 ... 6 mm²
Stripping length 9 mm 10 mm
Tightening torque 0.8 ... 1.2 Nm 2 Nm
Recommended screw driver M3.5 M4
Type Rated instantaneous short-circuit current setting li
You can find the address of your local sales organization on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems
Contact us
Note:We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.
We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB AG.