Data cable (Class 6.6.4.1) l For extremely heavy duty applications l TPE outer jacket l Double-shielded l Oil and bio-oil resistant l PVC and halogen-free l Hydrolysis and microbe-resistant
chainflex® CF12
Example imageFor detailed overview please see design table
Outer jacket Low-adhesion, extremely abrasion-resistant and highly flexible TPE mixture, adapted to suit the requirements in e-chains®.Colour: Steel-blue (similar to RAL 5011)Printing: white
„00000 m“* igus chainflex CF12.--.--.02j ---k EAC CE RoHS-II
conform www.igus.de +++ chainflex cable works +++
* Length printing: Not calibrated. Only intended as an orientation aid.j / k Cable identification according to Part No. (see technical table).Example: ... chainflex ... CF12.02.04.02 ... (4x(2x0.25)C)C ... EAC ...
Data cable (Class 6.6.4.1) l For extremely heavy duty applications l TPE outer jacket l Double-shielded l Oil and bio-oil resistant l PVC and halogen-free l Hydrolysis and microbe-resistant
chainflex® CF12
These values are based on specific applications or tests. They do not represent the limit of what is technically feasible.
Dynamic informationBend radius e-chain® linear minimum 10 x d
flexible minimum 8 x dfixed minimum 5 x d
Temperature e-chain® linear -35 °C up to +100 °Cflexible -50 °C up to +100 °C (following DIN EN 60811-504)fixed -55 °C up to +100 °C (following DIN EN 50305)
v max. unsupported 10 m/sgliding 6 m/s
a max. 100 m/s²
Travel distance Unsupported travel distances and up to 400 m for gliding applications, Class 6
Guaranteed service life according to guarantee conditions 5 million 7.5 million 10 million
Temperature,from/to [°C]
R min. [factor x d] R min. [factor x d] R min. [factor x d]
-35/-25 12.5 13.5 14.5
-25/+90 10 11 12
+90/+100 12.5 13.5 14.5
Minimum guaranteed service life of the cable under the specified conditions.The installation of the cable is recommended within the middle temperature range.
Double strokes
Electrical informationNominal voltage 300/300 V (following DIN VDE 0298-3)
Data cable (Class 6.6.4.1) l For extremely heavy duty applications l TPE outer jacket l Double-shielded l Oil and bio-oil resistant l PVC and halogen-free l Hydrolysis and microbe-resistant
chainflex® CF12
Properties and approvalsUV resistance High
Oil resistance Oil resistant (following DIN EN 60811-404), bio-oil resistant (following VDMA 24568 with Plantocut 8 S-MB tested by DEA), Class 4
Silicone-free Free from silicone which can affect paint adhesion (following PV 3.10.7 – status 1992)
Halogen-free Following DIN EN 60754
EAC Certificate No. RU C-DE.ME77.B.01254 (TR ZU)
Lead-free Following 2011/65/EC (RoHS-II)
Clean room According to ISO Class 1. The outer jacket material of this series complies with CF9.15.07 - tested by IPA according to standard DIN EN ISO 14644-1
CE Following 2014/35/EU
Typical lab test setup for this cable seriesTest bend radius R approx. 100 - 200 mm
Test travel S approx. 1 - 15 m
Test duration minimum 2 - 4 million double strokes
Data cable (Class 6.6.4.1) l For extremely heavy duty applications l TPE outer jacket l Double-shielded l Oil and bio-oil resistant l PVC and halogen-free l Hydrolysis and microbe-resistant
chainflex® CF12
Typical application areas For heaviest duty applications, Class 6 Unsupported travel distances and up to 400 m and more for gliding applications, Class 6 Almost unlimited resistance to oil, also with bio-oils, Class 4 No torsion, Class 1 Indoor and outdoor applications, UV-resistant For maximum EMC protection Storage and retrieval units for high-bay warehouses, Machining units/machine tools, quick handling, Clean room,
semiconductor insertion, outdoor cranes, low temperature applications
Data cable (Class 6.6.4.1) l For extremely heavy duty applications l TPE outer jacket l Double-shielded l Oil and bio-oil resistant l PVC and halogen-free l Hydrolysis and microbe-resistant
chainflex® CF12
Part No. Number of cores and conductor nominal cross section
Outer diameter (d) max. Copper index Weight
[mm²] [mm] [kg/km] [kg/km]
CF12.02.04.02 (4x(2x0.25)C)C 11.0 51 174
CF12.05.03.02 (3x(2x0.5)C)C 13.5 65 228
CF12.05.04.02 (4x(2x0.5)C)C 14.5 83 266
CF12.05.06.02 (6x(2x0.5)C)C 17.0 128 388
CF12.05.08.02 (8x(2x0.5)C)C 20.5 163 516
CF12.05.10.02 (10x(2x0.5)C)C 23.0 203 600
CF12.05.14.02 (14x(2x0.5)C)C 23.0 297 705
CF12.10.06.02 (6x(2x1.0)C)C 20.0 198 537
Note: The given outer diameters are maximum values and may tend toward lower tolerance limits.G = with green-yellow earth core x = without earth core
Technical tables:Mechanical information
Conductor nominal cross section
Maximum conductor resistance at 20 °C(following DIN EN 50289-1-2)
Maximum current rating at 30 °C(following DIN VDE 0298-4)
[mm²] [Ω/km] [A]
0.25 79.0 5
0.5 39.0 10
1 19.5 17
Electrical information
The final maximum current rating depends among other things on the ambient conditions, the type of the installation and the number of loaded cores.
Data cable (Class 6.6.4.1) l For extremely heavy duty applications l TPE outer jacket l Double-shielded l Oil and bio-oil resistant l PVC and halogen-free l Hydrolysis and microbe-resistant
Data cable (Class 6.6.4.1) l For extremely heavy duty applications l TPE outer jacket l Double-shielded l Oil and bio-oil resistant l PVC and halogen-free l Hydrolysis and microbe-resistant
chainflex® CF12
Colour code in accordance with DIN 47100Conductor no.