Data Center Test Solutions Ethernet in the Data Center - Webinar Kees Propstra November 18 th , 2020
Data Center Test Solutions Ethernet in the Data Center - Webinar
Kees PropstraNovember 18th, 2020
Test Challenges
Data Center Test SolutionsData Center Test Solutions
Engineering Life Cycle support
Data Center Test Solutions
Module and Port Optimization
Optical Modules, AOCs and DACs encounter new challenges at PAM4 rates
▪ Power consumption is key - optimization of power consumption yields significant cost savings
▪ MultiLane BERTs support fine-tuning of TX and RX EQ to trade-off BER performance and power consumption for both hosts and pluggables
TX/RX Equalization Control
7-Tap TX Equalization
RX EQ and Diagnostics
EQ Optimization using ML BERT
Moduleoptimization
Switchoptimization
Module and Port Optimization
Error-prone PAM4 designs require advanced BER tracking capabilities▪ Error bursts are a major concern and must be
correctly identified and diagnosed
▪ ThunderBERT enables tracking of cumulative and instantaneous BER data
PAM4 systems rely on Forward Error Correction to stabilize erroneous links▪ ThunderBERT supports Real Hardware RS-FEC Analysis
▪ Correctable/Uncorrectable Codeword count▪ SER Histogram
BER and FEC Analysis
History Navigation to track BER Data
KP4 SER Histogram
Compliance testing
Data Center Test Solutions
Optical Testing
Transmitter
DUT O-DSOBERT
Clock
MCB
ML4041-K-56QSFP56 MCB 4x56Gb
ML4015D-25-SM/MM25 GHz SM O-DSO
ML4039D200G BERT
Test pattern generation PAM4 Eye Diagram etc.
IEEE 802.3bs clause 122. 200GBASE-FR4, 200GBASE-LR4, 400GBASE-FR8, and 400GBASE-LR8
Optical Testing
Test Procedure - stressed eye closure
Stressed Receiver Sensitivity – SRSSRS block diagram
O-DSO ML4015D
JTOL Clock Source ML407-PAM
BERT ML4039D/ML4039EN
E-O MX35D
Open Eye MSA receiver specifications: table 4-3
BERT signal
Add filter (FFE) + Interference (crosstalk noise)
Add Sj JTOL
Calibrated stressed eye
Optical Testing
Measure BER as a function of optical power (AOP, OMA)
Receiver Sensitivity
Integrated Optical Switch Box for SR4 and FR4 transceivers• MLO4034-SR4• MLO4034-CWDM4
BER
ROP
Electrical Testing
Receiver Stress testing
DUTBERT MCB
ML4041-K-56QSFP56 MCB 4x56Gb
ML4039EN200/400G BERTWith Crosstalk Noise
Optical loopback
JTOL Clock
0.0
1.0
2.0
3.0
4.0
5.0
6.0
0.0E+00 5.0E+05 1.0E+06 1.5E+06 2.0E+06 2.5E+06 3.0E+06
Sj m
agni
tude
[U
I]
Frequency [Hz]
Sj vs frequency
ML407-PAMJTOL Clock Source
Clean signal
Impaired signal
IEEE802.3bs Annex 120EChip-to-module(200GAUI-4 C2M)
Electrical Testing
Transmitter testing
DUT
BERT
MCB
ML4041-K-56QSFP56 MCB 4x56Gb
ML4039D200G BERT
Optical loopback orshallow loopback
DSO
ML40254CH 50 GHz E-DSO
Table 120E–3—200GAUI-4 and 400GAUI-8 C2M module output characteristics (at TP4)
Clock
Figures of merit 200GAUI-4
Manufacturing testing
Data Center Test Solutions
DUTBERT Adapter Switch + VOA + PM
O-DSO
4x
ML4054B-QSFPField replace-able interfaceReplace after 500 insertions
Test Electrical IO BER Test Optical IO BER
Test Optical transmitter
MLO4034-SR4/CWDM4Optical Switch Box
ML4015D-25-SM/MM25 GHz SM/MM O-DSO
ML4054B200/400G Manufacturing BERT
Hardware FEC testingTest pre- and post-FECBER/SER
RMA testing
ML7007 Series Productivity Software:
▪ Fully automated test report
▪ Pass/Fail results
It supports most Single Mode (SM) and Multi Mode (MM) 10 to100G optical transceivers available in the market. (200/400Gcoming soon)
▪ Return merchandise authorization (RMA) testing
▪ New supplier validation & incoming inspection
Data Center Test Solutions
‘Optics PhD in a box’
Get PhD insight into your DUT from your Technicians and
Operators!
CMIS testing
CMIS X.X complexity is a challenge for 400GE deployments
ML4066 Adapters and Analyzers / ML4054B
▪ Validate CMIS compliance
▪ Monitor and save I2C transactions between host and pluggable
▪ Validate State Machine command execution
▪ Load and Save Entire MSA files
▪ Read or write individual module registers
Data Center Test Solutions
Module Compliance Board▪ User friendly GUI for I2C R/W
commands and loading custom MSA Memory Maps
▪ Gain access to all high-speed Tx and Rx signals
▪ Compliant with CEI-56G-VSR
▪ DUT voltage supply control
▪ DUT Current Sense
▪ Temperature Monitor
▪ On-board LEDs showing MSA output Alarm states
Host Compliance Board▪ Gain access to all high-speed Tx and Rx
signals
▪ Compliant with CEI-56G-VSR
Connectivity
Data Center Test Solutions
ML4041K-56 Insertion Loss ML4064-HCB Insertion Loss
Port validation
How to validate the proper operation of your system port?▪ Can the port recognize a transceiver? CMIS compatible?
▪ Sufficient Signal Integrity?
▪ Can the system support the intended thermal/power load?
Loopback/thermal loads▪ SI traces loopback Port TX into RX
▪ MSA Housing Compatible▪ QSFP-DD, OSFP, QSFP28, etc.
▪ Programmable power dissipation▪ Up to 30W QSFP-DD800 / OSFP 800
▪ Fully customizable – emulate your Data Center Interconnect
Data Center Test Solutions
Smart Loopbacks
QSFP-DD Example
▪ MSA compatible configuration and EEPROM
▪ Programmable MSA memory pages
▪ Custom memory maps
▪ Low speed I2C signal status
▪ Detect control signals
▪ Force alarm signals
Data Center Test Solutions
LCD Display LED Indicator Pin Header
LCD power state indicator
Monitored LCD
R & G Indicators
Alarm System
4 Temp.Sensors
Voltage Sensor
Current Sensor
Pin header connector
Port Troubleshooting
▪ Loopback test indicates SI problem – high BER
▪ Impedance measurements help identify source of problem
▪ The ML4035 enables TDR Testing for port debug:▪ Isolate impedance mismatches and discontinuities▪ Pass/Fail verdict for each lane▪ Gated TDR enables hone-in on fault area
(for instance, a bad connector or broken pin)▪ Sub ohm accuracy▪ ~1 mm resolution
Data Center Test Solutions
What is next? 800G
Data Center Test Solutions
Conclusions
▪ Equalization tuning critical for system optimization
▪ Hardware FEC provides insight into real system performance
▪ Module compliance testing is a multi-dimensional test challenge
▪ CMIS validation is important for Interoperability
▪ Connectivity to your DUT is a hard requirement for your testing
▪ System Engineering requires stringent Port validation
▪ Port troubleshooting critical part of system debug
▪ Development tools for 800G & volume manufacturing solutions for 400G are needed now
Data Center Test Solutions
THANK YOU