Enclosure Strategies for Efficiency – Data Center Efficiency Best-Practice Starts with Your Racks

Historically, Data Center managers didn't invest much thought in their deployment of server racks beyond basic functionality, air flow, and the initial cost of the rack itself. Today, the widespread deployment of high-density configurations is causing major hot spot concerns and capacity issues. These factors, along with the high cost of power, require a sound understanding of how your server rack deployment plan relates to your overall efficiency strategy.

To view the recorded webinar presentation, please visit http://www.42u.com/enclosure-strategies-webinar.htm
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Data Center Server Rack Strategies

42U Confidential ©2008 42U All rights reserved Slide 1

Enclosure Strategies for Efficiency – Data Center Efficiency Best-

Practice Starts with Your Racks

September 5, 2008

________________________________

Page 2: Data Center Server Rack Strategies

Overview

• Business Factors

• Data Center Strategy

• Rack Designs

• Rack Arrangement

• Rack Configuration

• Summary

• Q&A

42U Confidential ©2008 42U All rights reserved Slide 2

Page 3: Data Center Server Rack Strategies

Business Factors

• Service Level Agreement (SLA)– N+1 and 2N Requirements

• Information Technology Infrastructure Library (ITIL)

• Total Cost of Ownership (TCO)

• Stranded Capacity

42U Confidential ©2008 42U All rights reserved Slide 3

Page 4: Data Center Server Rack Strategies

Efficiency Drivers

• Rising Energy Costs• Physical Limitations

– Building Infrastructure– Utility Capabilities

• Mandates– Carbon Tax– Utility Initiatives– C-Level Need for ‘Green’ Message

42U Confidential ©2008 42U All rights reserved Slide 4

Page 5: Data Center Server Rack Strategies

Energy Cost Projection

42U Confidential ©2008 42U All rights reserved Slide 5

Source: Uptime Institute

Page 6: Data Center Server Rack Strategies

Data Center Strategy

• Virtualization

• Blades

• Application Expansion

• Facilities

• Power Management

• Air Handling Infrastructure

42U Confidential ©2008 42U All rights reserved Slide 6

Page 7: Data Center Server Rack Strategies

Rack kW Trend

• 10 kW of Load Becoming the Norm

• Continued Increasing Density

42U Confidential ©2008 42U All rights reserved Slide 7

Source: IDC, The Impact of Power and Cooling on Data Center Infrastructure

Page 8: Data Center Server Rack Strategies

Energy Consumers

• 70% of Power Consumption Goes to the Infrastructure

• Over Twice that of the IT Equipment

42U Confidential ©2008 42U All rights reserved Slide 8

Source: The Green Grid, Guidelines for Energy-Efficient Datacenters

Page 9: Data Center Server Rack Strategies

Functional Limitations

• CRACs Are Reaching Their Functional Limits

42U Confidential ©2008 42U All rights reserved Slide 9

Source: Aperture, Managing Today’s Data Centers, Avoiding the Impending Crisis

Page 10: Data Center Server Rack Strategies

Rack Designs

• 2-, 4-Post Open– Low Heat Equipment

• Perforated– Ambient Cooling– Maximum Thermal Airflow

• Enclosed– Airflow Control– In-Row Cooling

42U Confidential ©2008 42U All rights reserved Slide 10

Page 11: Data Center Server Rack Strategies

Efficiency Strategies

• Variable-Speed Fans• Power Design• Modularity• Airflow Control

– Perforated Tile Configuration– Blanking Panels– Floor Grommets– Containment

42U Confidential ©2008 42U All rights reserved Slide 11

Page 12: Data Center Server Rack Strategies

Density Distribution

• Close-Coupled Cooling

• High-Density Checkerboard

42U Confidential ©2008 42U All rights reserved Slide 12

Source: APC, Ten Cooling Solutions, #42

Page 13: Data Center Server Rack Strategies

Confirmation of Fundamentals

• Impact of a Single Blanking Panel

• Consistent Results For– Floor Leaks– Tile

Arrangement

Top of rack

Middle of rack

42U Confidential ©2008 42U All rights reserved Slide 13

Page 14: Data Center Server Rack Strategies

Results of Floor Tile Tuning

• Improved Under-Floor Pressure

• Measurable Correlation to Cooling Efficiency

Under-Floor Pressure

Rack-Top Temperatures

42U Confidential ©2008 42U All rights reserved Slide 14

Page 15: Data Center Server Rack Strategies

Rack Management

• Hot/Cold Aisle

• Density Distribution Scheme• Modularity• Structured Cabling

42U Confidential ©2008 42U All rights reserved Slide 15

Source: APC, Ten Cooling Solutions, #42

Page 16: Data Center Server Rack Strategies

Airflow Containment

• Aisle Containment

• 30-49% Increase in CRAH/CRAC Capacity

42U Confidential ©2008 42U All rights reserved Slide 16

Source: Accenture/LBNL Air Flow Study 2007

Page 17: Data Center Server Rack Strategies

Hot Aisle Containment

• 40% Reduction in Fan Energy

42U Confidential ©2008 42U All rights reserved Slide 17

Source: Accenture/Oracle Data Center Air Flow Management – Hot Aisle Containment

Page 18: Data Center Server Rack Strategies

Cold Aisle Containment

• 75% Reduction in Fan Energy

42U Confidential ©2008 42U All rights reserved Slide 18

Source: Accenture/LBNL Air Flow Study 2007

Page 19: Data Center Server Rack Strategies

Efficiency Checklist

• Reduce Your Electric Bills– 20-50% for

No/Low-Cost Design and Operations Changes

42U Confidential ©2008 42U All rights reserved Slide 19

Source: The Green Grid, Guidelines for Energy-Efficient Datacenters

Page 20: Data Center Server Rack Strategies

Summary

• Consider the Big Picture

• Rack Configuration Plan

• Rack Layout Plan

• Airflow Containment

• Efficiency Improvement Plan

42U Confidential ©2008 42U All rights reserved Slide 20

Page 21: Data Center Server Rack Strategies

Q&A

42U Confidential ©2008 42U All rights reserved Slide 21

For More InformationContact Your 42U

Data Center Efficiency Consultant:

1-800-638-2638 or www.42U.com

For a Copyof

Today’s Presentation Email:

[email protected]

Please Type Your Questions In The Chat Window

Thank You