Page 1: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

DATA ANALYSIS FROM THE CERN TEST EXPERIMENT ABOUT THE HADES ELECTROMAGNETIC CALORIMETER

By : Tazio TorrieriSupervisor : Vladimir Wagner

Page 2: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

PLAN

HADES experiment

The HADES electromagnetic calorimeter

The CERN test experiment

Data analysis and results

Page 3: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

HADESHigh Acceptance Di-Electron Spectrometer

Page 4: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

HADES

Study of nuclear matter properties at high density : Modification of hadron properties

Page 5: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

HADES Detection of electron-positron pair

Extract the invariant mass of light vector mesons (ω, ρ, Φ)

Page 6: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

HADES ELECTROMAGNETIC CALORIMETER

Page 7: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

HADES ELECTROMAGNETIC CALORIMETER

Aim : Improvement of the signal from light vector mesons by removing the background.

Two main sources of background :

π0 → γ + e− + e+ η → γ + e− + e+ Dalitz decay≈ 1.2

%Charged pions

Page 8: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

HADES ELECTROMAGNETIC CALORIMETER Detection of gamma pair :

π0 → γ + γ η → γ + γ

Better π− / e− supression for large momenta

Page 9: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

HADES ELECTROMAGNETIC CALORIMETER Replace the HADES pre-shower detector Placed at 2.40 m from the target 8m² required Angle covering : 18° < θ < 45°

≈ 840 lead glass modules from OPAL experiment

Module dimensions : 42 x 9.2 x 9.2 cm

Page 10: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

CERN TEST EXPERIMENT

Page 11: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

CERN TEST EXPERIMENT

Page 12: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

DATA ANALYSIS AND RESULTS

Page 13: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

Distribution of the energy deposited in the first detector

Page 14: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

Electron peakfitting for the first detector

Page 15: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

Energy calibration

Energy resolution

Expected resolution :5% / √E (GeV)

Page 16: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

Gaussian + Exponential fitting

Gaussian + Parabole fitting

Page 17: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

Distribution of the energy deposited in the first detectorafter energy calibration

Page 18: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

200 400 600 800 10001200140016001800200022000.700

0.750

0.800

0.850

0.900

0.950

1.000

1.050

e− / π− separation

Series1Series5Series9

Energy (MeV)

π−

sep

/ al

l π−

Page 19: Data analysis from the CERN test experiment about the HADES electromagnetic calorimeter

QUESTIONS ?