MEGGITT S.A.
FRIBOURG / SWITZERLAND
Subject DAS USER GUIDE
Doc. No. N/A
Item DATA ACQUISITION SOFTWARE Type : DAS PNR :
259-102-000-xxx
Application CMC-116 for EMBRAER PNR : 251-116-013-0SS
Prepared by : Approved by : Released by :
Rev Date Engineering Engineering Section Leader
Project Manager
01 27.07.11 D.SCHERER J-C. COULET A. JOVER
Distribution Complete document : Customer : EMBRAER CAGE
CODE
Production Engineering, Project Team Leader S3960 PAGE 1
Title page only : Configuration Management OF 51 PAGES
EXPORT CONTROL Information contained in this document may be
subject to Export Control Regulations of the European Union, USA or
other countries. Each recipient of this document is responsible for
ensuring that transfer or use of any information contained in this
document complies with all relevant Export Control Regulations. ECN
N/A. PROPRIETARY INFORMATION This document and its contents are
CONFIDENTIAL and are protected by trade secret, copyright, and
other applicable laws. It is to be used only as authorised by
Meggitt SA. Unauthorised use is illegal.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 2
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 3
REVISION RECORD SHEET
REV DATE DESCRIPTION PM N
00 19.04.07 Update for DAS version 021 Add front page and
revision record sheet 6.X : update for the new DAS version
06419
01 27.07.11 Update for DAS version 25.0 Updated chapter 2:
- Removed reference to Windows 95 / 98, NT, ME / 2000; they are
not supported anymore.
- Added USB/RS-232 adapter installation notes. Update Front
Page
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 4
TABLE OF CONTENTS
1 ABBREVIATIONS AND DEFINITIONS
.................................................................................................................
61.1 ABBREVIATIONS
........................................................................................................................................................
62 INSTALLING THE DAS PROGRAM
......................................................................................................................
72.1 DAS PROGRAM INSTALLATION
.................................................................................................................................
72.2 USB/RS-232 ADAPTER INSTALLATION
PROCEDURE...............................................................................................
11
2.2.1 USB/RS-232 Adapter Installation
.................................................................................................................
112.2.2 DAS Installation Procedure (Win XP/Win 7)
................................................................................................
112.2.3 DAS Installation Procedure (Vista)
..............................................................................................................
11
3 GENERAL
.................................................................................................................................................................
143.1 OVERVIEW
..............................................................................................................................................................
143.2 FUNCTIONALITY
......................................................................................................................................................
14
3.2.1 Startup sequence
...........................................................................................................................................
154 RUNNING THE DAS PROGRAM
..........................................................................................................................
165 USER INTERFACE
..................................................................................................................................................
175.1 MENUS
....................................................................................................................................................................
17
5.1.1 Main Menu
....................................................................................................................................................
185.1.2 Download Menu
............................................................................................................................................
185.1.3 Preview Menu
...............................................................................................................................................
195.1.4 Print Menu
....................................................................................................................................................
205.1.5 Clear Menu
...................................................................................................................................................
215.1.6 Tools Menu
...................................................................................................................................................
225.1.7 Help Menu
....................................................................................................................................................
235.1.8 Exit Menu
......................................................................................................................................................
23
5.2 VIEWS
.....................................................................................................................................................................
245.2.1 Viewing CMC Maintenance and Exceedance Messages
...............................................................................
245.2.2 Viewing CMC Trend Data
............................................................................................................................
255.2.3 Viewing CMC Trend Dig Data
.....................................................................................................................
265.2.4 Viewing CMC Exceedance data
....................................................................................................................
275.2.5 Viewing CMC FLS data
................................................................................................................................
285.2.6 Viewing CMC FLS Dig Data
........................................................................................................................
295.2.7 Viewing CMC FADEC SNAPSHOT Data
....................................................................................................
305.2.8 Viewing FADEC Data Recorder
...................................................................................................................
315.2.9 Viewing FADEC Data recorder error data
..................................................................................................
325.2.10 Viewing FADEC Realtime Analog Labels
....................................................................................................
335.2.11 Viewing FADEC Realtime Discrete Labels
..................................................................................................
355.2.12 Viewing FADEC Labels data
........................................................................................................................
37
5.3 DIALOGS
.................................................................................................................................................................
385.3.1 DAS Selection Dialog
...................................................................................................................................
385.3.2 Memory Status Area Dialog
..........................................................................................................................
405.3.3 Clear Memory Areas Dialog
.........................................................................................................................
415.3.4 Directory Selection Type
Dialog...................................................................................................................
425.3.5 Download Dialog
..........................................................................................................................................
435.3.6 FADEC - Label Type Dialog
........................................................................................................................
445.3.7 FADEC Data Recorder Dialog
.....................................................................................................................
455.3.8 FADEC Labels Select Dialog
.......................................................................................................................
46
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 5
6 FILES
..........................................................................................................................................................................
476.1 DAS DIRECTORY STRUCTURE
................................................................................................................................
47
6.1.1 Aircraft Contents
...........................................................................................................................................
476.1.2 Doc Contents
................................................................................................................................................
476.1.3 Lbs Contents
.................................................................................................................................................
476.1.4 Ini File Contents
...........................................................................................................................................
47
6.2 CREATED FILES
.......................................................................................................................................................
487 CMC DATA
...............................................................................................................................................................
497.1 EXCEEENCE DATA
...................................................................................................................................................
497.2 TREND DATA
..........................................................................................................................................................
507.3 MAINTENANCE DATA
..............................................................................................................................................
507.4 FLS DATA
...............................................................................................................................................................
507.5 FADEC SNAPSHOT DATA
.......................................................................................................................................
517.6 REALTIME ARINC 429 DATA
.................................................................................................................................
517.7 DIG CODES
.............................................................................................................................................................
51
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 6
1 Abbreviations and Definitions
1.1 Abbreviations
ARINC 429 A communication protocol, commonly used on
aircraft
CMC Central Maintenance Computer
COM1 Communication port 1 for serial interface communication
DAS Data Acquisition Software
EXC Exceedance
FADEC Hardware for collecting and transmitting all engine
data
FDSN FADEC Fault Word Snapshot
FLS Flight Leg Summary
INI Initialization file used for storing configuration data and
loaded at program start
MSG Maintenance Messages
PC Personal Computer
PNR Part Number
RS232 Serial Communications Bus/Protocol
TRN Trend
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 7
2 Installing the DAS program
2.1 DAS Program Installation
The DAS software has an automatic install procedure.
Windows Version Setup file to execute Windows XP, Vista, 7
DAS-xx.x-setup.exe
Note: xx.x is the version of the DAS (in the following example
xx.x = 25.0). Step 1: To start the install procedure, execute the
setup file from the table above. The following window will be
displayed.
Step 2: Read the text and press Next.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 8
Step 3: Choose for which users you want to install DAS and press
Next.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 9
Step 4: Choose the folder in which to install the DAS program,
and then press Install.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 10
Step 5: Click Finish to close the DAS installation wizard.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 11
2.2 USB/RS-232 Adapter Installation Procedure The following
USB/RS-232 adapter installation procedure applies to the Vivanco
USB SER-N 23425 adapter. The installation procedure for another
USB/RS-232 adapter might be slightly different. Adapter Type :
Vivanco USB SER-N 23425 (www.vivanco.de) Supported platforms : Win
98SE, 2000, ME, XP, Win7, Vista Supplied with adapter: CD-ROM
containing device drivers and installation instruction manual
2.2.1 USB/RS-232 Adapter Installation 1.
DonotconnecttheUSBadaptertotheUSBportonyourcomputer!2.
InserttheCDROMintoyourCDROMdrive.3. Windows98SE,ME,2000,XP:
DoubleclickWinXDriverInstaller.exe
WindowsVista,7: DoubleclickVistaDriverInstaller.exe4.
Followtheinstructionsonthescreen5.
ConnecttheUSBadaptertoyourcomputer6. Windows98SE:
ThesystemwillaskyoutoinserttheWin98SECDROM,andcopy
thenecessaryfiles.WindowsME,2000,XP,Vista,7:
Thehardwareisrecognizedandinstalledbythesystem.
Once the system recognized and installed the serial adapter, a
system message popped-up saying that a new COM Port (COM4 on our
test laptop used for Win7/Vista compatibility tests) is available
and ready for use.
2.2.2 DAS Installation Procedure (Win XP/Win 7)
Followtheinstructionsin2.1toinstalltheDASprogram.
EditthefileC:\ProgramFiles\VibroMeter\DAS\\Ini\das.ini
Replace:ComPort=COM1byComPort=COMn(wherenistheIDoftheCOMportavailablethroughtheUSBadapter)
2.2.3 DAS Installation Procedure (Vista)
MakesureallthelatestMicrosoftpatchesandupdatesfortheOShavebeeninstalledproperly.Without
thosepatches,theDASapplicationwillnotwork.
CreateaDASfolderintheC:\Users\Publicdirectory.
DoubleclickontheDASsetup.exefiletostarttheinstallation.
IntheChooseInstallLocationdialog,clicktheBrowsebutton,andselecttheC:\Users\Public\DASfolder.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 12
The Choose Install Location window should look like this:
Click the Install button to finish the installation. CAUTION: Do
not install DAS into the default C:\Program Files\Vibro-Meter\DAS
folder. The DAS application will not work when installed into this
directory!
Edit the file C:\Users\Public\DAS\\Ini\das.ini:
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 13
Replace ComPort=COM1 by ComPort=COMn (where n is the ID of the
COM port available through the USB adapter) Replace
AircraftPath=C:\Program Files\Vibro-Meter\DAS\Aircraft\ by
AircraftPath=.\DAS\Aircraft\ Replace FadecRecorderDATA=C:\Program
Files\Vibro-Meter\DAS\Lbs\Default.lbs by
FadecRecorderDATA=.\DAS\Lbs\Default.lbs Make sure
TestActive=FALSE
Save your changes and close the editor If an error message
pops-up when starting DAS for the 1st time, double-click on
C:\Users\Public\DAS\\vcredist_x86.exe which will install the
Microsoft Visual Studio 2005 redistributables.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 14
3 General
3.1 Overview
The DAS (Data Acquisition Software) receives data from the CMC
(Central Maintenance Computer) and displays the data in a readable
format for the Maintenance personnel. The DAS is compatible with
all CMC versions and displays the CMC data accordingly. Detection
of CMC versions 10 and higher is performed automatically, while
with versions lower than 10, the user must manually perform the
detection.
CMC PCSerial Rs232
Display
Files
DAS System Overview
3.2 Functionality The following is a list of the DAS
functionality
Download CMC Data, Download Real-time CMC Data, Record CMC Data,
Clear CMC Data, Display CMC Data on Screen, Write CMC Data to
Files, Print CMC Data.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 15
3.2.1 Startup sequence
1. When the Application starts up, the Serial Port is
initialized. 2. The CMC Version is requested, for versions 10 or
higher the version is automatically detected.
3. For older CMC versions, a dialog shown in the figure below is
displayed enabling the user to
input the correct CMC version.
4. Following this procedure, the main dialog is displayed to
allow the user to select the DAS functions.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 16
4 Running the DAS program
Step 1: In your computer, double click on the DAS icon.
The DAS program starts and displays the following window.
Step 2: Select one of the buttons to download the CMC data:
Full DAS This option allows full access to all DAS
functionalities. Automatic DAS This option performs an automatic
downloadind of all
data and stores the data on a floppy disk, if requested. Upon
completion the DAS Selection dialog appears.
FADEC Labels This option displays the Preview FADEC Realtime
screen followed by the dialog for selecting Analog or Discrete
Labels. Upon completion the DAS Selection dialog appears.
Note: Exit terminates the program
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 17
5 User Interface
The Application is Menu and Dialog based, comprising of several
dialogs, one Scrolling view for displaying Download data and two
Form views for displaying the FADEC Real-Time Data.
5.1 Menus
Menus enable the selection of the different functions in the
Full DAS, with the user selecting with the mouse or keyboard the
required menu option, corresponding to the task required to be
performed. In the following items, the menus and options available
are detailed.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 18
5.1.1 Main Menu
5.1.2 Download Menu
Provides options to allow the user to select which CMC data
shall be verified.
All Performs the download of Maintenance and Exceedance
Messages, Trend Data, Exceedance Data, FLS Data, FADEC Snapshot and
FADEC Labels.
Trend/Exceedance/FLS Downloads the Trend, Exceedance and FLS
Data. Maint_Exceed Message Downloads the Maintenance and Exceedance
Messages. FLS Data Downloads the FLS Data. FADEC Snapshot Downloads
the FADEC Snapshot. FADEC Labels Downloads all discrete and analog
FADEC Labels for all
FADEC sources (1A/1B/2A/2B). Single File Downloads the
Exceedance Data, Maintenance and
Exceedances messages, FADEC Snapshot and FADEC labels and stores
the data in a single file.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 19
5.1.3 Preview Menu
Provides options to allow the user to view the data previously
downloaded from the CMC. Also activates the Real-time viewing of
FADEC Labels.
Maint_Exceed Message Previews the Maintenance and Exceedance
Messages. Trend Data Previews the Trend Data. Trend Dig Previews
the Trend and Exceedance Data in Dig format. Exceedance Previews
the Exceedance Data. FLS Data Previews the FLS Data. FLS Dig
Previews the FLS Data in Dig format. FADEC Snapshot Previews the
FADEC Snapshot. FADEC Data Recorder Previews the FADEC Data
Recorder labels previously
recorded using the Tools/FADEC Data Recorder option. FADEC Real
Time Previews the FADEC Labels (Analog or Discrete) in real
time. FADEC Labels Previews the FADEC Labels (Analog and
Discrete together)
of FADEC 1A, 1B, 2A or 2B previously downloaded. Message Status
Displays the DAS internal memory area status.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 20
5.1.4 Print Menu
Provides options to allow the user to Print out the data that
was downloaded from the CMC.
Maint_Exceed Message Prints out the Maintenance and Exceedance
Messages. Exceedance Prints out the Exceedance Data. Trend Data
Prints out the Trend Data. Trend Dig Prints out the Trend and
Exceedance Data in Dig format. FLS Data Prints out the FLS Data.
FLS Dig Prints out the FLS Data in Dig format. FADEC Snapshot
Prints out the FADEC Snapshot. FADEC Data Recorder Prints out the
FADEC Data Recorder. FADEC Error Files Prints out the FADEC Data
Recorder errors results. FADEC Labels Prints out the FADEC Labels
(Analog and Discrete together)
of FADEC 1A, 1B, 2A or 2B previously downloaded. Single File
Prints out the Exceedance Data, Maintenance and Exceedance
Messages, FADEC Snapshot and FADEC labels stored in a single
file.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 21
5.1.5 Clear Menu
Provides options to allow the user to clear the data that is
stored in the CMC.
Maint Message Clears the Maintenance Messages. Exceedance Clears
the Exceedance Data and Exceedance Messages. Trend Clears the Trend
Data. FLS Clears the FLS Data. FADEC Snapshot Clears the FADEC
Snapshot. All Clears all the above data.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 22
5.1.6 Tools Menu
Provides options to allow the user to record FADEC Labels
previously selected and recorded to a file with a specific source,
also allowing the visualization of the file that records FADEC bits
errors. Configures the font and serial port.
FADEC Data Recorder Opens the FADEC Data Recorder Dialog. View
error file Previews the FADEC Data Recorder Error results. Options
Allows the user to configure the font and serial interface.
Note: The System Options is available only when activated in the
INI file providing the following options:
Save Data, force the data to be re-saved into its corresponding
file. Load / Save Raw data, allows later loading of an actual
download. Get Version, Gets the CMC version and restarts the
program. Generate Test Data, Generates random data used for
testing.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 23
5.1.7 Help Menu
Provides information of the DAS as can be seen in the
example.
5.1.8 Exit Menu
Used for exiting the software.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 24
5.2 Views
5.2.1 Viewing CMC Maintenance and Exceedance Messages
Menu option: Preview->Maint_Exceed_Message
The Scrolling View displays the CMC Maintenance and Exceedance
Messages downloaded to the computer.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 25
5.2.2 Viewing CMC Trend Data
Menu option: Preview->Trend-> Trend Data
The Scrolling View displays the CMC Trend Data downloaded to the
computer. Each leg represents the Takeoff /Cruise Trend recorded
during one single flight.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 26
5.2.3 Viewing CMC Trend Dig Data
Menu option: Preview->Trend->Trend Dig
The Scrolling View displays the CMC Trend Dig Data downloaded to
the computer.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 27
5.2.4 Viewing CMC Exceedance data
Menu option: Preview->Exceedance
The Scrolling View displays the CMC Exceedance Data downloaded
to the computer.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 28
5.2.5 Viewing CMC FLS data
Menu option: Preview->FLS->FLS Data
The Scrolling View displays the CMC FLS Data downloaded to the
computer.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 29
5.2.6 Viewing CMC FLS Dig Data
Menu option: Preview->FLS->FLS Dig
The Scrolling View displays the CMC FLS Dig Data downloaded to
the computer.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 30
5.2.7 Viewing CMC FADEC SNAPSHOT Data
Menu option: Preview->FADEC Snapshot
The Scrolling View displays the CMC FADEC Snapshot Data
downloaded to the computer.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 31
5.2.8 Viewing FADEC Data Recorder
Menu option: Preview->FADEC data recorder
The Scrolling View displays the FADEC Data Recorder stored in
the computer.
Note: The label data is displayed in Hexadecimal values.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 32
5.2.9 Viewing FADEC Data recorder error data
Menu option: Tools->View error file The Scrolling View
displays the FADEC Data recorder error data.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 33
5.2.10 Viewing FADEC Realtime Analog Labels
Menu option: Preview->FADEC Real-time ----- Analog selection
----- FADEC Source
The View Real-time Analog Labels displays continuously the CMC
FADEC Analog Labels for the FADEC Source Selected (1A, 1B, 2A or
2B).
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 34
Where the meaning for the fields is explained below:
FADEC Source Selected FADEC Source.
A/C Ident Aircraft Identification (via hardware) in the CMC.
Flight Aircraft Flight number. Data Contains the label data and
description for all the analog
labels. Errors Displays any errors to the CMC. Stop Real-time
Stops the downloading of real-time data. Select Labels Allows the
user to switch to another analog label or to
the discrete labels. Re-start Re-starts the real-time
downloading after it has been
stopped. Das Selection Returns to the Das Selection Dialog.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 35
5.2.11 Viewing FADEC Realtime Discrete Labels
Menu option: Preview->FADEC Real-time ----- Discrete
selection----- FADEC Source
The View Real-time Discrete Labels displays continuously the CMC
FADEC Discrete Labels for the FADEC Source Selected (1A, 1B, 2A or
2B).
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 36
Where the meaning for the fields is explained below:
FADEC Source Selected FADEC Source.
A/C Ident Aircraft Identification (via hardware) in the CMC.
Flight Aircraft Flight number. Update Rate Time difference between
the label data, updated only
when the connection to the CMC is working. Data Contains the
label data and description for all the
discrete labels. Errors Displays any errors to the CMC. Stop
Real-time Stops the downloading of real-time data. Select Labels
Allows the user to switch to another discrete label or to
the analog labels. Re-start Re-starts the real-time downloading
after it has been
stopped. Das Selection Returns to the Das Selection Dialog.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 37
5.2.12 Viewing FADEC Labels data
Menu option: Preview->FADEC Labels->FADEC 1A(FADEC 1B, 2A,
2B) The Scrolling View displays the Analog and Discrete FADEC
Labels previously downloaded.
Note: *** means the label was not downloaded.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 38
5.3 Dialogs
All Dialogs allow to the user to enter program options or
perform a specific action.
5.3.1 DAS Selection Dialog After startup the following dialog is
displayed to allow the user to choose a DAS option.
Where the meaning for the fields is explained below: CMC Version
The current CMC version selected or found. Directory Selection
Type
Directory selected by Serial or Aircraft number.
Auto Message Clear State
Shows the auto message clear status..
Save to floppy Shows the save to floppy disk status. Change
Options This option displays the dialog for changing the
startup
options as described: Directory Selection Type: allows the files
to be
stored by Tail number or Serial number Auto Message Clear asks
the user if the data
already downloaded shall be erased.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 39
Save to Floppy asks the user if the files already downloaded to
the computer shall also be saved in a floppy disk.
Full DAS This option allows full access to all DAS
functionalities. Automatic DAS This option performs an automatic
download of all data
and store the data on a floppy disk if requested. Upon
completion the DAS Selection dialog appears.
FADEC Labels This option displays the Preview FADEC Realtime
screen followed by the dialog for selecting Analog or Discrete
Labels. Upon completion the DAS Selection dialog appears.
Exit This option terminates the Program.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 40
5.3.2 Memory Status Area Dialog This dialog box appears when the
following sequence is used: Menu option: Preview->Message Status
It displays the status of the DAS internal memory and current
files.
Where the meaning for the fields is explained below:
Open Opens the displayed file in an editor. Status Indicated the
status of the Data Loaded. OK or Cancel Exits the dialog. Clear
Calls the DAS clear memory area dialog.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 41
5.3.3 Clear Memory Areas Dialog
This dialog box appears when the following sequence is used:
Menu option: Preview->Message Status ----- Clear This
function is used to clear the internal data in the DAS program,
used to erase previous data in the displays.
Where the meaning for the fields is explained below:
Clear Clears the internal data in the DAS program. All Selects
all areas for clearing.
Cancel Aborts the Clear area operation.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 42
5.3.4 Directory Selection Type Dialog
The access to the option below is through the Change Button in
the DAS Selection screen. This dialog box has the following
options:
Directory Selection Type that changes to tail number or serial
number the directory name where the files are stored,
Auto Message Clear State Option that selects if the CMC shall be
erased automatically or not after an automatic downloading and
Save to Floppy Option that requests or not that the files be
recorded to a floppy disk after the downloading is performed.
Note: The OK is used to change the required setting and the
Cancel is used to abort any changes made.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 43
5.3.5 Download Dialog
Shows the state of the current download, allows the user to stop
or re-start the download.
Where the meaning for the fields is explained below:
Messages Provides messages informing about the downloading
process. Action List of downloads to perform. OK Exits the
dialog. Cancel Do not save or clear the data. Serial Break Stops
the download. Repeat Restarts the download after an error has
occurred.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 44
5.3.6 FADEC - Label Type Dialog Menu option: Preview->FADEC
Realtime or Menu option: DAS Selection Screen->FADEC Labels
Used to selects the FADEC label to be displayed in the real-time
mode.
Where the meaning for the fields is explained below:
Label Selects Analog or Discrete labels. FADEC Source Selects
the FADEC Source to monitor. FADEC Discrete Label Select
Selects which discrete label will be monitored.
OK The selected label is monitored. Cancel The real-time mode is
not activated.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 45
5.3.7 FADEC Data Recorder Dialog Menu option: Tools->FADEC
data recorder This dialog records selected FADEC labels of selected
sources.
Where the meaning for the fields is explained below:
Data File for storing File where the record results will be
stored. Browse Selects the path where the record results file is.
Label Select File Displays the current file that contains the
labels to be
recorded. Duration of recording The time in seconds for which
the recording will be
active. Start Record Initiates the data recording. Cancel Aborts
the dialog and returns to the Main window. New Opens the FADEC
Labels Select dialog allowing the
selection of label(s) and source(s) that will be recorded in the
file.
Edit Edits the file created.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 46
5.3.8 FADEC Labels Select Dialog
Menu option: Tools->FADEC data recorder --- New or Menu
option: Tools->FADEC data recorder --- Edit
Displays the screen used to select/edit the FADEC labels.
Where the meaning for the fields is explained below:
ALL Selects all labels in its group. Save As Saves the label
information in a new file. Save Saves the label information in the
current file. Cancel Aborts the changes made.
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 47
6 Files
6.1 DAS Directory Structure By default, the DAS application is
installed in C:\Program Files\Vibro-Meter\DAS.
Directory Description
DAS Main project directory containing DAS executable
DAS\Aircraft Sub directory to manage Aircraft specific files
DAS\Doc Sub directory containing the DAS release notes. DAS\Ini Sub
directory containing DAS initialization file DAS\Lbs Sub directory
to manage User FADEC Recorder files
6.1.1 Aircraft Contents
The Aircraft directory stores the files with the result of the
downloading performed.
6.1.2 Doc Contents The Doc directory contains the DAS release
notes file (PDF).
6.1.3 Lbs Contents
The Lbs directory stores the files used for selecting FADEC
Labels during a record session. These files are created and used by
the DAS software automatically.
6.1.4 Ini File Contents
The Ini directory allows the program to be configured without
being recompiled. The following Ini files entries are currently
available. Parameter Type Description
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 48
Parameter Type Description AircraftPath PATH Directory where the
files will be stored TestActive TRUE If test mode is active
AutoClear TRUE If Clear data is to be asked ComPort COM1 For serial
port com1 communication FadecRecorderDATA STRING Directory where
the Recorder files will be
stored FadecRecorderINTERVAL INTEGER For the FADEC Recorder
recording time FadecRecorderLBS FILENAME LBS file last used
AircraftNo STRING Current aircraft number TailNo STRING Current
tail number PrintFontSize INTEGER Font size used for printing
SystemOptions TRUE If the system options are to be available
UseTailNumber 0 or 1 1: if the tail number is to be used instead
of
aircraft number WindowPosLeft INTEGER Saved window position
WindowPosTop INTEGER Saved window position WindowPosRight INTEGER
Saved window position WindowPosBottom INTEGER Saved window position
AnimationEnabled TRUE If the animation in the status bar is enabled
SerialTimeoutShortMs INTEGER Timeout for the serial interface
SerialTimeoutLongMs INTEGER Timeout for the serial interface
SerialRetries INTEGER Number of retries allows SaveToFloppy TRUE If
the save files to disk question is to asked FloppyPath PATH Path to
save the floppy files.
6.2 Created Files The downloaded files are stored by the
following convention. Filename Used for Maaaaddmmmyyc.dat
Maintenance Messages Taaaaddmmmyyc.dat Trend data Taaaaddmmmyyc.dig
Trend and Exceedance data without text. Eaaaaddmmmyyc.dat
Exceedance data Faaaaddmmmyyc.dat Flight Leg Summary data
Faaaaddmmmyyc.dig Flight Leg Summary data, without text
Faaaaddmmmyyc.1a FADEC 1A Labels Faaaaddmmmyyc.1b FADEC 1B Labels
Faaaaddmmmyyc.2a FADEC 2A Labels Faaaaddmmmyyc.2b FADEC 2B Labels
Naaaaddmmmyyc.dat FADEC Fault word Snapshot Saaaaddmmmyyc.dat
Single file data,Maint, Exceed, FADEC
Snapshot,FADEC Labels
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 49
Where :
aaaa AC Ident dd day mmm month yy year c Counter
Example: M012322FEB021.dat : Maintanence data, Aircraft ID 0123,
22 Feb 2002, count =1
7 CMC Data
Below is an explanation of how the data is organized, ordered
and displayed. For all data type except the real time data there is
a Header followed by the data then a checksum. The Header
defines
How many bytes are contained in the message, If a CMC memory
area is nearly full and a download followed by a Clear is required,
The Aircraft Identification, Status of the message.
Each data type contains Leg Status, which has the following
values.
UNUSED Leg does not contain any valid data. PREVIOUS Leg
contains valid data. LAST Leg contains valid data and is the
current Leg in use.
Each data type may contain Data Status, which has the following
values.
UNUSED Does not contain any valid data. USED Contains valid
data.
7.1 Exceeence Data
The Exceedance Message is split into two areas.
1. Leg Information: Leg Status values of UNUSED , PREVIOUS,
LAST
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 50
First Pointer Index to the first data block used in this Leg
Last Pointer Index to the last data block used in this Leg
2. Leg Data: Maximum 100 Legs with 10 exceedances in each
leg.
The Display order is oldest Leg first, newest leg last.
Note: The Leg Status is a circular buffer
7.2 Trend Data
The Trend Area contains a Maximum of 75 Legs and each leg
contains the following.
Leg Status values of UNUSED , PREVIOUS, LAST Engine 1 Takeoff
Data Contains Data status and data Engine 2 Takeoff Data Contains
Data status and data Engine 1 Cruise Data Contains Data status and
data Engine 2 Cruise Data Contains Data status and data
The Display order is oldest Leg first, newest leg last. Note:
The Leg Status is a circular buffer
7.3 Maintenance Data
The Maintenance Area contains a maximum of 100 messages. The
Display order is newest message first, oldest message last. Note:
The Messages are in a circular buffer.
7.4 FLS Data
The FLS Area contains a Maximum of 75 Legs The Display order is
oldest Leg first, newest leg last. Note: The Leg Status is a
circular buffer
-
DAS Application User Guide Rev 01
MEGGITT SA FRIBOURG / SWITZERLAND
PAGE 51
7.5 FADEC Snapshot Data
The FADEC Snapshot Area contains a Maximum of 10 Legs. The
Display order is oldest Leg first, newest leg last. Note: The Leg
Status is a circular buffer
7.6 Realtime ARINC 429 Data When Real-time mode is activated,
the labels are sent continuously for approximately 5 seconds, after
which the real-time mode is switched off and no more data will be
received. To receive further labels, the real-time mode must be
reactivated to transmit the labels for a further 5 seconds.
7.7 DIG Codes Each set of data has a code that is used in the
DIG files according to the following definition:
Code Meaning 00-34 Takeoff Trend 10-31 Cruise Trend 20-18 N1
Exceednace 30-18 N2 Exceedance 40-16 ITT Exceedance 50-15 N1
Vibration Exceedance 60-14 N2 Vibration Exceedance 70-13 Oil Low
Pressure Exceedance 80-13 Oil High Temp Exceedance 90-13 Fuel High
Temp Exceedance 91-10 FADEC Overtemp A0-46 Flight Leg Summary
Dataset 00-00 Unkown