1. Air conditioners should not be installed in areas where
corrosive gases, such as acid gas or alkaline gas, are produced.2.
If the outdoor unit is to be installed close to the sea shore,
direct exposure to the sea breeze should be avoided. If you need to
install the outdoor unit close to the sea shore, contact your local
distributor.
Cautions on product corrosion
Warning Ask a qualified installer or contractor to install this
product. Do not try to install the product yourself. Improper
installation can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Use only those parts and accessories supplied or specified by
Daikin. Ask a qualified installer or contractor to install those
parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water
or refrigerant leakage, electrical shock, fire or explosion.
Read the User's Manual carefully before using this product. The
User's Manual provides important safety instructions and warnings.
Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer,
distributor and/or retailer.
PVVMT1325
Heat Pump 50Hz
official Catalogue.
All rights reservedPrinted in Vietnam 06/12/001 VK
HEAD OFFICE
VAN PHONG CHNH
CHI NHANH HA NOI
CHI NHANH A NANG
CONG TY CO PHAN VIET KIMUmeda Center Bldg., 2-4-12,
Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan
Tang 14-15, toa nha Nam A, 201-203 Cach Mang Thang 8, P.4, Q.3,
TP.HCMTel: (08) 62 504 888 Fax: (08) 62 504 999
Tel: (04) 35 657 677 Fax: (04) 35 657 688
Tel: (0511) 362 4250 Fax: (0511) 362 4251
www.daik in .com.vn
Tang 12, toa nha Ocean Park Tower, 1 ao Duy Anh, Quan ong a, Ha
Noi
Tang 12, Lo A2.1, ng 30/4, P. Hoa Cng Bac, Q. Hai Chau, TP. a
Nang
ai ly phan phoi
www.nhathaucodienlanh.com-0976525242
-
COP 4.41 Achieved Strengthened line up by 3 types
Expanded to 60 HP Enhanced comfort with built in sensor
01
First launched in Japan in 1982, the Daikin VRV system has been
embraced by world markets for over 30 years.
Now, Daikin proudly introduces the next generation VRV IV
system.It now offers improved energy savings, comfort,
and ease of installation to meet
an ever wider variety of needs.
Next Generation VRV IV System
02
* VRV is a trademark of Daikin Industries, Ltd.
INDEX
P03
P12
P13
P34
P55
P63
P75
Main Features
Outdoor Unit Lineup
Indoor Unit Lineup
Outdoor Unit Combinations
Air Treatment Equipment Lineup
Specifications
P57Option List
Control Systems
www.nhathaucodienlanh.com-0976525242
-
Improve Coefficient of Performance (COP)
Quiet Operation
Excellent Operation Performance in compact design
Improve heat exchanger efficency, helps to reduced operation
sound.
Lower operation sound
Lineup
*12 HP of VRV IV improves more compact design and more saving
space than VRV III0
3
3.5
4
4.5
5
6 HP 8 HP 10 HP 12 HP 14 HP 16 HP 18 HP
4.414.30
3.843.72
3.673.46
3.25
*
Strengthened Lineup by 3 types Energy Saving
Peak in outdoor temperaturePeak in outdoor temperaturePeak in
outdoor temperaturePeak in outdoor temperaturePeak in outdoor
temperature
Enable night mode Enable night mode Enable night mode Enable
night mode Enable night mode
Large airflow, high static pressure and quiet technologyWithout
increasing operation sound, advanced analytic technologies are
utilized to optimise fan design and increase airflow rate and high
external static pressure of 78.4Pa.
Nighttime quiet operation function
Outdoor PCB automatically memorises the time when the peak
outdoor temperature appears. It will enable quiet operation mode
after 8 h*1, and return to normal mode after it keeps for 9
h*2.
*1 8 h is the initial setting with 6 h or 10 h also available.*2
9 h is the initial setting with 8 h or 10 h also available.
Notes: This function is available in setting at site. The
operating sound in quiet operation mode is the actual value
measured by our company. The relationship of outdoor temperature
(load) and time shown
above is just an example.
Streamlined air grilleIt promotes the discharge of swirling
airflow, further reducing the pressure loss.
Streamlined scroll fanThe sharp edge of each fan blade has a
certain curvature, reducing both the vibration and the pressure
loss.
Streamlined scroll fan
Illustrated fan
Ope
ratin
g so
un
d (d
B)Lo
ad
(%)
Capa
city
(%
) Night mode
min. 40 dB(A)
8 hrs
8:00
50
60
50
100
0
40
57
12:00 16:00 20:00 0:00 4:00 8:00
9 hrs
VRV IV VRV IV
6HP 8HP 10HP 12HP57
55 56 57 5957 58 60
High-Cop Type
Standard Type
Space Saving Type
20HP
20HP
20HP
Enables further energy saving 12HP-50HP with 4 new models
lineup
Offers higher capacity of up to 60HP6HP-60HP with 3 new models
lineup
New series with compact & lightweight design18HP-50HP with
17 new models lineup
VRV
HP
High-COP Type
Standard Type
Space Saving Type
Mo/C New Lineup
COP during cooling operation 3.93
Product Weight 490 kg
14%Decrease
22%Decrease
Installation Space 1.66 m2
380 kg
1.42 m2
VRV
Ena12H
EnergySaving
C
Up to60HP
CompactDesign
Mai
n Fe
atur
es
CoolingOperation
3.94
COP during cooling operation
Product Weight 490 kg
11%Increase
Installation Space 1.66 m2
555 kg2.13 m2
VRV
VRV
VRV
3.94
COP during cooling operation 3.11
Product Weight 490 kg
43%Decrease
35%Decrease
Installation Space 1.66 m2
320 kg
0.95 m23.94
4.36
03 04www.nhathaucodienlanh.com-0976525242
-
More options for installation location
More Flexible System Design
The long piping length provides more design flexibility, which
can match even large-sized buildings.
Long piping length
Maximum allowablepiping length
Minimum allowable piping length
When a mixed combination of VRV and residential indoor units is
connectedor when only residential indoor units are connected
Maximum allowablelevel difference Between the outdoor unit
and the indoor unit
Between BP unitand indoor unit
Between the indoor unitsBetween BP units
Between the first indoor branch and the farthest BP unit
orbetween the first indoor branch and the farthest VRV indoor
unit
Total piping lengthRefrigerant piping length
Between outdoor unit and the first indoor branch
15 m15 m
lm
n
n
o
a+b+c+d+e+f+g+h+i+j+k
b+c+g, b+c+d
a+b+c+g+k, a+b+c+d
h, i, j, k
a
100 m250 m
2 m15 m
2 m12 m2 m8 m
50 m*1
5 m
Actualpiping length Example
Level Difference Example
50 mIf the outdoor unit is above.If the outdoor unit is
below.
If indoor unit capacity index < 60.If indoor unit capacity
index is 60.If indoor unit capacity index is 71.
40 m
40 m*1. When the piping length exceeds 20 m, the size of the
main pipes (the gas side and the liquid side) must be increased.
Please refer to Engineering
Data Book for details.
Max. 50 m
Max. 40 m
Max. 15 m
Max. 15 m
a
o
l
n
dcbgfeFirst indoor branch
mh i
VRV : VRV indoor unitRA : Residential indoor unitBP : BP
unit
When a mixed combination of VRV andresidential indoor units is
connected
When only VRV indoor units are connected
jk
Between the outdoor unit and the BP unit
BP
RA RA
RA
RA
VRV
VRV
BP
Conditions of indoor unit connection capacity
Connection capacity at maximum is 200%.Connection ratio
Note:
* For the FXFQ25LU,FXFQ-S and FXVQ models, maximum connection
ratio is 130% for the entire range of outdoor units.
If the operational capacity of indoor units is more than 130%,
low airflow operation is enforcedin all the indoor units.
50%200%Connection ratio
Single outdoor units
Double outdoor units
Triple outdoor units
FXDQ, FXMQ-P, FXAQ modelsApplicable indoor units
200%
Other indoorunit models*
200%160%130%Connection ratio =
Total capacity index of the indoor unitsCapacity index of the
outdoor units
165 m
190 m
1000 m
Max. equivalent piping length
Outdoor unit above indoor unit:
2. Level differences above 50 m are available on request.Outdoor
unit below indoor unit:
1. No special requirements up to 40 m. The maximum actual piping
length can be 90 m, depending on conditions. Various conditions and
requirements have to be met to allow utilisation of 90 m piping
length. Be sure to refer to the Engineering Data Book for details
of these conditions and requirements.
2. Level differences above 50 m are not supported by default but
are available on request (If the outdoor unit is above the indoor
unit).
Maximumallowablelevel difference
Maximumallowablepiping length
Between the outdoor unitsand the indoor units
Between the indoor units
Between the outdoor units (Multiple use)
Between the first indoor branch and the farthest indoor unit
Between the outdoor branch and the last outdoor unit
Total piping length
Refrigerant piping length
30 m
90 m
5 m
90 m
q
s
r
r
a+b+c+d+e+f+g+h+i
a+f+g+h+i
f+g+h+i
k+p
165 m 190 m
1000 m
90 m**1
10 m 13 m
Actualpiping length
Equivalentpiping length Example
Level Difference Example
2 Available on requestIf the outdoor unit is above.
If the outdoor unit is below.
90 m 2
90 m
Max. actual piping length
Max. total piping length
Max. level differencebetween the outdoor unitsand the indoor
units
p
q
k
First outdoor branch
fab
Firstindoor branch
Multiple use
*The rest of indoor units are the same as for single use.
a
i
s
r
hgfedcb
First indoor branch
Single use
Colours in the diagram above are merely for identifying pipes
referenced with symbols such as a .
Outdoor unit combinations
*1. Only single outdoor unit (RXQ6-20TY1) can be connected.*2.
Total capacity index of connectable indoor units must be 50%130% of
the capacity index of the outdoor unit.
RXQ6TY1RXQ8TY1
RXQ10TY1RXQ12TY1RXQ14TY1RXQ16TY1RXQ18TY1RXQ20TY1
16.022.428.033.540.045.050.056.0
6HP8HP10HP12HP14HP16HP18HP20HP
150200250300350400450500
75100125150175200225250
150200250300350400450500
19550% 100% 130%
Combination (%)*2Total capacity index of connectable indoor
units*2
260325390455520585650
913161922262932
Model name*1 kW HP CapacityindexMaximum number of
connectable indoor units
Colours in the diagram below are merely for identifyingpipes
referenced with symbols such as a .
Mai
n Fe
atur
es
05 06www.nhathaucodienlanh.com-0976525242
-
Unit Alternate Operation Technology Long-term and stable
equipment operation
Reliable And Stable System
Daikin VRV IV system incorporates the humanized and efficient
test operation function, not only greatly accelerating the
installation process, but effectively improving the field setting
quality as well.
Efficient automatic test operation
AlternationAlternation
Automatically checks the wirings between outdoor units and
indoor units to confirm whether there is a defective wiring.
Confirms and corrects the actual piping length.
Automatically check whether the stop valve in each outdoor unit
is in normal status to ensure the smooth operation of air
conditioning system.
Automatic check
At the system starting, Daikin VRV IV system will automatically
enable the Unit Alternate Operation Function, which ensures the
long-term and stable equipment operation by balancing the operating
time of each outdoor unit.
Double backup operation functions responding resiliently to
various unexpected situations
Stage 1 Stage 2 Stage 3
Priority: Priority:
Alternation AlternationAlternationAlternation
Priority:
Daikin VRV IV system boasts double backup operation functions,
which can secure the use of air conditioners in this area to the
greatest extent by emergently enabling double backup operation
functions even if failure occurs in a set of air conditioning
equipment.
Double backup operation functions
Efficient after-sales service
VRV IV system utilises seven-segment luminous digital tubes to
display system operation information, visualising the operation
state and facilitating commissioning and after-sales service.
Function of information display by luminous digital tubeUnit
backup operation functionIf malfunction occurs in an outdoor
unit...Emergency operation can be conveniently set and enabled by
the remote controller for indoor unit (for systems composed of two
or more outdoor units ).
If malfunction occurs in a compressor...Emergency operation can
be easily set and enabled by the outdoor unit (for a single outdoor
unit system RXYQ14-20TY1 models).
Compressor backup operation function
7-segment luminous digital tubes utilized to display
information
Conventional light-emitting diodes utilized to display
information
Displays system operation information directly
Figures out system operation information by reading light
emitting state of different diodes, which is both inefficient and
fallible.
Multiple advanced features ensuring more accurate test operation
and stable system
Mai
n Fe
atur
es
Wiring check
Piping check
Stop valve check
07 08www.nhathaucodienlanh.com-0976525242
-
Small type large capacity inverter compressor Various advanced
control main PC board
Advanced Technologies Achieve Excellent Performances
Highly integrated heat exchanger
Computer control board SMT packaging material
*SMT: Surface mounted technology
Computer control board surface adopting SMT packaging
technology
Conventional computer control
board surface
SMT packaging technology adopted by the whole computer control
panel improves the anti-clutter performance.Protects your computer
boards from the adverse effect of sandy and humid weather.
SMT* packaging technologyLarge capacity inverter compressor
using high tension strength material,realise 12HP compressor using
8HP casing.
Mai
n Fe
atur
es
Small sizing coil end using concentrated winding, reduce copper
loss (winding resistance).
Improve motor efficiency in low rpm range (improve intermediate
efficiency).
Distributed winding motor(Current 8HP compressor)
Concentrated winding motor(New 12HP compressor)
Coilend
Gives 2.4 times tensile strength compare to conventional
materialNew Material: 600MPa Conventional Material : 250MPa
Increase compression chamber volume by using thin spiral
design.
As a result of having thinned a wall - thickness of the scroll,
compression chamber volume increase 50%
Improve performance by increasing heat exchanger area while
maintaining the same installation space
Change fin shape from fine louvre to waffle fin. Fin pitch can
be reduced fin pitch from 2.0mm to 1.4mm, to realise unit
efficiency which increased heat exchanger area.
Realise highly integrated heat exchanger performance(increase
row, reduce fin pitch) by reducing of airflow resistance which
changes cooling tube to 7.
Heat exchangerarea
Contribution of COP(cooling) 10HP16HP
13%UP 105.5%24%UP 111.5%
Fine Louver Fin Waffle Fin
Downsize electric component, re-locate to dead space of bell
mouth side to decrease airflow resistance.
Organise inner design to increase smooth airflow
Refrigerant cooling technology, ensures stability of PCB
temperature
Control board failure ratio at stable operation is reduced.
Improve reliability at high ambient temperature It is possible
to cool the inverter power module stability even at high ambient
temperature.This helps to keep air-conditioning capacity and also
reduces failure ratio.
Bell mouth
Electric Component Space
Roof terrace temperature in summer is over 40 C,
seriouslyaffecting inverter cooling efficiency, resulting in
decline ofinverter operating speed. Finally device parts
response
speed is reduced.
3 row with small pipe design,increases heat transfer
efficiency
20HP
Development of high strength material
Small type high efficiency concentrated winding motor
VRV
VRV
09 10www.nhathaucodienlanh.com-0976525242
-
Outdoor Units
Outdoor Unit Lineup
The outdoor unit capacity is up to 60 HP in increment of 2
HP.VRV IV outdoor unit offers a higher capacity of up to 60 HP,
responding to the needs of large-sized building.The single outdoor
unit has only 2 different shapes and dimensions, not only
simplifying the design process, but also bringing the system
flexibility to a new level.With the outdoor unit capacity increased
in increment of 2 HP, customers' needs can be precisely met.
12, 14, 16 HP
RXYQ18THY1RXYQ20THY1RXYQ22THY1RXYQ24THY1
RXYQ36THY1RXYQ40THY1
RXYQ42THY1RXYQ44THY1RXYQ46THY1RXYQ48THY1RXYQ50THY1
RXYQ12THY1RXYQ14THY1RXYQ16THY1
RXYQ6TY1RXYQ8TY1
RXYQ10TY1RXYQ12TY1
RXYQ18TY1RXYQ20TY1
RXYQ22TSY1RXYQ24TSY1
RXYQ26TSY1RXYQ28TSY1RXYQ30TSY1RXYQ32TSY1
RXYQ34TSY1RXYQ36TSY1RXYQ38TSY1RXYQ40TSY1
RXYQ42TSY1RXYQ44TSY1
RXYQ46TSY1RXYQ48TSY1RXYQ50TSY1
RXYQ14TY1RXYQ16TY1
RXYQ18TNY1RXYQ20TNY1
18, 20, 22, 24, 26, 28, 30, 32 HP 36, 40 HP
42, 44 HP 46, 48, 50, 52, 54, 56, 58, 60 HP
Triple Outdoor Units
Triple Outdoor Units
Triple Outdoor Units
Double Outdoor Units
6, 8, 10, 12 HP 14, 16 HP 22, 24, 26 HP 28, 30, 32 HP 34, 36 HP
38, 40 HP
18, 20 HP 22, 24 HP 26, 28, 30, 32 HP 34, 36, 38, 40 HP
Single Outdoor Units Double Outdoor Units
Single Outdoor Units Double Outdoor Units Double Outdoor
Units
High-COP Type
Standard Type
Space Saving Type
RXYQ34THY1RXYQ38THY1
RXYQ28TNY1RXYQ30TNY1RXYQ32TNY1
RXYQ22TNY1RXYQ24TNY1RXYQ26TNY1
RXYQ34TNY1RXYQ36TNY1
RXYQ38TNY1RXYQ40TNY1
RXYQ42TNY1RXYQ44TNY1
RXYQ46TNY1RXYQ48TNY1RXYQ50TNY1RXYQ52TNY1
34, 38 HP 42, 44, 46, 48, 50 HP
46, 48, 50 HP42, 44 HP
18, 20 HP
RXYQ54TNY1RXYQ56TNY1RXYQ58TNY1RXYQ60TNY1
RXYQ26THY1RXYQ28THY1RXYQ30THY1RXYQ32THY1
Heat Pump
11 12
Outd
oor U
nit L
ineup
www.nhathaucodienlanh.com-0976525242
-
Features of new VRVVRV indoor units Wide range of choices from 2
lineup
Indoor Unit Lineup
A mixed combination of VRV indoor units and residential indoor
unitsis enabled all in one system. Opening the door to stylish and
quiet indoor units.
FXUQ-A FXVQ-M
4-Way Flow Ceiling Suspended TypeThis slim, stylish indoor unit
achieves optimum air distribution, and can be installed without the
need for ceiling cavity.
Flaps close automatically when the unit stops whichgives a
simple appearance. Unified slim height of 198 mm. for all models
which gives a unified impression when models with different
capacities are installed in the same area.
VRV indoor units
Wall Mounted
Slim CeilingMounted Duct
Ceiling MountedCassette (Compact Multi Flow)
Type Model Name Rated Capacity 2.5 kW 6.0 kW 7.1 kW5.0 kW3.5
kWCapacity Index 25 60 715035
252.0 kW
20
20 60 715035
FFQ-BV1B
CDXS-EAVMA
FDXS-CVMA
Ceiling Mounted Cassette FCQ-BVE*
Ceiling MountedBuilt-in FBQ-BV1*
FTXS-DVMAFTXS-EVMA
FTXS-FVMA
(700 mm width type)
(900/1,100 mm width type)
7 types 22 models
17 types 86 models
Note: BP units are necessary for residential indoor units. Only
single outdoor unit (RXYQ6-20TY1) can be connected.
198 mm
BEV unit is not needed
FXFQ-SVM
FXVQ-MY1(6)*
Floor Standing Duct TypeLarge air volume type for
largespaces.Flexible interior design for each tenant.
5 directions of airflow can be selected with wired remote
controller BRC1E62, which realises optimum air distribution.
Built-in electronic expansion valve eliminates the need for a
BEV unit which improves flexibility of installation.
Residential indoor units with connection to BP units
Indo
or U
nit L
ineu
p
*FXVQ, FCQ and FBQ models are not available to the Hong Kong
market.
Detects presence or absence of any human. Detection of average
floor temperature realises comfortable air-conditioning without
loss of speedy and leads to energy savings.
FXFQ
Ceiling Mounted Casette type
Infrared Presence SensorThe presence of people is detected in
the room to deliver optimum air distribution. When no people are
detected during a continuously fixed time, the air conditioner
automatically stops or lowers capacity.
Infrared Floor SensorThe floor temperature is detected and
temperature differences between floor and ceiling are reduced.
Individual Flap ControlFore flaps individually control airflow
direction to prevent direct drafts on people.
Auto Operation for Energy SavingAuto Airflow rate mode + Auto
airflow direction mode
Infrared floor sensor detects the average floor temperature.
Total comfort by individual flap control and newly-equipped
airflow block function
Airflow block air velocity approx. 0.3m/s *1
Also can support such this case
Airflow block for cabinet
side
Airflow block function prevents uncomfortable drafts by reducing
air velocity to approx. 0.3m/s. *1
*1. In case of 63 type (Data is based on Daikin research.)
Airflow block function enables setting by remote controller with
no need for sealing material of air discharge outlet (option).
Comfortable Cooling
Comfortable Cooling that does not become cold at floor
level.
Conventional cassette type
ColdFloor temp.
20C
Cool air stays near the floor causing feet to get cold.
Round flow with sensing(Auto Operation for Energy Saving)
When people are detected, the unit controls airflow
direction
to prevent direct drafts.
The sensor detects low temperature
at floor level.
Floor temp.
28CSet temp. 28C
Energy SavingTo prevent excessive cooling at floor level,
airflow direction is automatically controlled.
Infrared presence sensor individually detects each of the areas
[ABCD] for the presence of people.
13 14www.nhathaucodienlanh.com-0976525242
-
Indoor Unit Lineup
Daikin offers a wide range of indoor units includes both VRV and
residential models responding to variety of needs of our customers
that require air-conditioning solutions.
Ceiling Mounted Cassette (Round Flow with Sensing) Type
Presence of people and floor temperature can be detected to
provide comfort and energy savings
Ceiling Mounted Cassette (Round Flow) Type
4-Way Flow Ceiling Suspended Type
This slim and stylish indoor unit achieves optimum air
distribution, and can be installed without the need for ceiling
cavity.
Ceiling Mounted Cassette (Double Flow) Type
Thin, lightweight, and easy to install in narrow ceiling
spaces
Slim Ceiling Mounted Duct Type
Slim design, quietness and static pressure switching
Wall Mounted Type
Stylish flat panel design harmonised with your interior dcor
Floor Standing Type
Concealed Floor Standing Type
Suitable for perimeter zone air conditioningCeiling Mounted
Cassette
(Compact Multi Flow) Type
Quiet, compact, and designed for user comfort
Floor Standing Duct Type
Large air volume type for large spaces.Flexible interior design
for each tenant.
Residential Indoor Units with connection to BP unit.
Ceiling Suspended Type
Slim body with quiet and wide airflow
Quiet, compact, and designedfor user comfort
Ceiling Mounted Cassette (Compact Multi Flow) Type
Specially designed for false ceilingsfor a smooth, modern
interior finish
Flexible air discharge unit tofit various forms of space
Ceiling MountedBuilt-in Type
Stylish flat panel harmoniseswith your interior dcor
Wall Mounted Type
Slim Ceiling MountedDuct Type
Slim and smooth design suitsyour shallow ceiling
Ceiling Mounted Duct Type
Ceiling MountedCassette Type
VRV Indoor Unit
High external static pressure allows flexible installations
Ceiling Mounted Cassette Corner Type
Slim design for flexible installation
FFQ-BV1B
CDXS-EAVMA
FDXS-CVMA
FCQ-BVE*
FBQ-BV1*
FTXS-DVMAFTXS-EVMA
FTXS-FVMA
FXFQ-SVM
FXDQ-PBVE(T)
FXDQ-NBVE(T)
360 airflow improves temperature distribution and offers a
comfortable living environment.
Indo
or U
nit L
ineu
p
FXVQ-MY1(6)*
15 16
*FXVQ, FCQ and FBQ models are not available to the Hong Kong
market.
www.nhathaucodienlanh.com-0976525242
-
Indoor Unit Lineup
360 airflow improves temperature distributionand offers a
comfortable living environment.
Note: Whatever the discharge direction, the same type of panel
is used. If installing for other than all-round flow, an air
discharge outlet sealing material (option) must be used to close
each unused outlet.
3-way flow L-shaped 2-way flowAll-round flow 4-way flow
The industrys first* Round Flow Ceiling Mounted Cassette type
offers 360 airflow with improved temperature distribution.
The light weight unit at 19.5 kg for FXFQ25-50LU models makes
installation easy.
A modern sophisticated decoration panel has been applied, with a
panel surface that has been treated with a dirt-repellant coating.
An antibacterial treatment that uses silver ions has
been applied to the drain pan, preventing the growth of slime,
mould and bacteria that cause blockages and odours.
The horizontal louvres prevent dew condensation. Their
non-flocking surfaces, which repel dirt, are easy to clean.
The air filter has an anti-mould and antibacterial treatment
that prevents the growth of mould generated from dust or moisture
that may adhere to the filter.
Example of airflow patterns:All-round flow is available, as well
as 2-way to 4-way flows, so you can choose the most suitable
airflow pattern depending on location or room layout.
Drain pump is equipped as a standard accessory with a 850 mm
lift.
Treated surface Untreated surface
Resists soiling
Condition after exposure to the smoke of 600 cigarettes in 1 m3
enclosed space.
Dirt andgrime
Control of the airflow rate can be selected from 3-step
control.
4-way flow Round Flow
There are areas of uneven temperature.
There are much fewerareas of uneven temperature.
* As of April 2004, the release date for Japan.
Low operation sound level (dB(A))
44/39/34
125
43/37.5/32
100
36/33.5/31
80
34/31/28
63
32/29.5/27
50
31/29/27
4025/32
30/28.5/27Soundlevel
(HH/H/L)
FXFQ-LU
850 mm
FXFQ25S/FXFQ32S/FXFQ40SFXFQ50S/FXFQ63S/FXFQ80SFXFQ100S/FXFQ125S
New Airflow Block function prevents uncomfortable drafts by
reducing air velocity and enables setting with wired remote
controller BRC1E62 with no need for sealing material of air
discharge outlet (option).
Drain pump is equipped as standard accessory with 850 mm
lift.
Control of airflow rate can be selected from 3-step control,
which provides comfortable airflow. Auto airflow rate control can
be selected with wired remote controller BRC1E62.
Low operation sound level
FXFQ25LU/FXFQ32LUFXFQ40LU/FXFQ50LU FXFQ63LU/FXFQ80LU
FXFQ100LU/FXFQ125LU
Presence of people and floor temperature can be detected to
provide comfort and energy savings
850 mm
Ceiling Mounted Cassette (Round Flow with Sensing) Type Ceiling
Mounted Cassette (Round Flow) Type
45/40/35
125
44/38/32
100
38/35/31
80
38/33/28
63
36/32/28
50
31/29/27
4025/32
30/28.5/27Soundlevel
(H/M/L)
FXFQ-S
VRV Indoor Units
Indoor unit offers 360 airflow discharges air in all directions
with more uniform temperature distribution.
Dual sensors detect the presence of people and floor temperature
to provide comfortable air-conditioning and energy savings.
With adoption of the individual airflow direction control,
airflow direction adjustment can be individually set for each air
discharge outlet to prevent direct drafts on people and deliver
optimum air distribution.
Dead spot of airflow
Presence of people in 4 areas
Detecting the average temperature of indoor floor
The sensor detects the human location and adjusts the airflow
automatically direction to prevent direct drafts.
Infrared presence sensor
Infrared floor sensorThe sensor detects the floor temperature
and automatically adjusts the operation condition of indoor unit to
reduce temperature difference between the ceiling and floor.
Energy efficiency has been improved thanks to the adoption of a
new heat exchanger with smaller tubes, DC fan motor and DC drain
pump motor.
lIndoor unit offers 360 airflow discharges air in all directions
with more uniform temperature distribution.
lDual sensors detect the presence of people and floor
temperature to provide comfortable air-conditioning and energy
savings.
lWith adoption of the individual airflow direction control,
airflow direction adjustment can be individually set for each air
discharge outlet to prevent direct drafts on people and deliver
optimum air distribution.
Dead spot of airflow
Presence of people in 4 areas
Detecting the average temperature of indoor floor
The sensor detects the human location and adjusts the airflow
automatically direction to prevent direct drafts.
The sensor detects the floor temperature and automatically
adjusts the operation condition of indoor unit to reduce
temperature difference between the ceiling and floor.
Infrared presence sensor
Infrared floor sensor
Indoor unit offers 360 airflow discharges air in all directions
with more uniform temperature distribution.
Dual sensors detect the presence of people and floor temperature
to provide comfortable air-conditioning and energy savings.
With adoption of the individual airflow direction control,
airflow direction adjustment can be individually set for each air
discharge outlet to prevent direct drafts on people and deliver
optimum air distribution.
Dead spot of airflow
Presence of people in 4 areas
Detecting the average temperature of indoor floor
The sensor detects the human location and adjusts the airflow
automatically direction to prevent direct drafts.
The sensor detects the floor temperature and automatically
adjusts the operation condition of indoor unit to reduce
temperature difference between the ceiling and floor.
Infrared presence sensor
Infrared floor sensor
17 18
Indo
or U
nit L
ineup
www.nhathaucodienlanh.com-0976525242
-
Indoor Units
This slim and stylish indoor unit achieves optimum air
distribution, and can be installed
without the need for ceiling cavity.Unit body and suction panel
adopted round shapes and realised a slim appearance design. The
unit can be used for various locations such as the ceilings with no
cavity and bare ceilings. Flaps close automatically when the unit
stops, which gives a simple appearance.Unified slim height of 198
mm for all models that gives the unified impression even when
models with different capacities are installed in the same
area.Built-in electronic expansion valve eliminates the need for a
BEV unit, which improves flexibility of installation.
With adoption of the individual flap control, airflow direction
adjustment can be individually set for each air outlet. 5
directions of airflow and auto-swing can be selected with wired
remote controller BRC1E62, which realises the optimum air
distribution.
Control of the airflow rate has been improved from 2-step to
3-step control. Auto airflow rate control can be selected with
wired remote controller BRC1E62. Energy efficiency has been
improved thanks to the adoption of a new heat exchanger with
smaller tubes, DC fan motor and DC drain pump motor.Drain pump is
equipped as a standard accessory, and the lift height has been
improved from 500 mm to 600 mm.Depending on installation site
requirements or room conditions, 2-way, 3-way and 4-way discharge
patterns are available.
4-way flow 3-way flow
L-shaped 2-way flow
198 mm
BEV unit is not needed
BEV unit is needed
Current model New model
Quiet, compact, and designed for user comfort Dimensions
correspond with 600 mm600 mm
architectural module ceiling design specifications.
Wide discharge angle: 0 to 60
2-, 3-, and 4-way airflow patterns are available, enabling
installation in the corner of a room.
Low operation sound level(dB(A))
0
60
0
60
Auto swing
Fixed angles: 5 levels
*Angles can be also set on site to prevent drafts (0-35) or
soiling of the ceiling (25-60), other than standard setting
(0-60).
32/2932/29
20/25 32 4040 5050
33/2933/29 36/3036/30 41/3441/34
FXZQ-M
750 mm
4-way flow 3-way flowL-shaped
2-way flow
1
2
0 0
60 60
FXZQ20M/FXZQ25M/FXZQ32MFXZQ40M/FXZQ50M
FXUQ71A/FXUQ100A
Comfortable airflow
Drain pump is equipped as standard accessory with 750 mm
lift.
Sound level(H/L)
Sound level(H/L)
*For 3-way or 2-way flow installation, the sealing member for
air discharge outlet (option) must be used to close each unused
outlet.
Ceiling Mounted Cassette (Compact Multi Flow) Type 4-Way Flow
Ceiling Suspended Type
VRV Indoor Units
Indoor Unit Lineup
Position 0 Position 2
Position 3 Swing
Individual airflow direction example case
19 20
Indo
or U
nit L
ineup
www.nhathaucodienlanh.com-0976525242
-
Thin, lightweight, and easy to install in narrow ceiling
spaces
FXCQ20M/FXCQ25M/FXCQ32MFXCQ40M/FXCQ50M/FXCQ63MFXCQ80M/FXCQ125M
(dB(A))
305 mm
The thin unit (only 305 mm high) can be installed in a ceiling
space as narrow as 350 mm. All models feature a compact design with
a depth of only 600 mm.
(When a high-efficiency filter is attached, the unit's height is
400 mm.)
Low operation sound level
Designed with higher airflow suitable for high ceiling
application up to 3 metres.
Providing 2 different settings of standard and ceiling soiling
prevention, the auto swing mechanism realises even distribution of
airflow and room temperature.
Two types of optional high-efficiency filter are available (65%
and 95%, colourimetric method).
A long-life filter (maintenance free up to one year*) is
equipped as standard accessory.* 8 hr/day, 25 day/month. For dust
concentration of 0.15 mg/m3
Drain pump is equipped as standard accessory with 600 mm
lift.
Major maintenance work can be performed by removing the panel. A
flat-type suction grille and a detachable blade make cleaning
easy.
600 mm
FXCQ-M 20
32/27
25/32
34/28
63
37/32
40/50
34/29
80
39/34
125
44/38Soundlevel (H/L)
Ceiling Mounted Cassette (Double Flow) Type Ceiling Mounted
Cassette Corner Type
Slim design for flexible installation
Main body
Air discharge grille (Option)
Set for front discharge using a suspended ceiling.
Downward discharge is shut off and air is blown straight out
(front discharge).
Front discharge is possible with an air discharge unit (option),
which allows the installation in the drop-ceiling or sagging
wall.
Single-flow type allows effective air discharge from corner or
from drop-ceiling.
Providing 3 different settings of standard, draft prevention and
ceiling soiling prevention, the auto swing mechanism realises even
distribution of airflow and room temperature.
Main body
Downward discharge
Air discharge grille (Option)
FXKQ25MA/FXKQ32MAFXKQ40MA/FXKQ63MA
3
32C 30C28C 26C 24C
22C
20C
2
1
0 1 2 3 4 5 6 (m)
(m)
500 mm
Drain pump is equipped as standard accessory with 500 mm
lift.
Panel spacer
20 mm
Min.195 mm
Slim body needs only 220 mm space above the ceiling. If you use
a panel spacer (option), the unit can be installed in the minimum
space of 195 mm.
A long-life filter (maintenance free up to one year*) is
equipped as standard accessory.
* 8 hr/day, 25 day/month. For dust concentration of 0.15
mg/m3
VRV Indoor Units
Indoor Unit Lineup
21 22
Indo
or U
nit L
ineup
www.nhathaucodienlanh.com-0976525242
-
Indoor Units
Slim design, quietness and static pressure switching
FXDQ20PB/FXDQ25PB/FXDQ32PB
External static pressure selectable by remote controller
switching make this indoor unit a very comfortable and flexible
model.10 Pa-30 Pa/factory set: 10 Pa for FXDQ-PB models.15 Pa-44
Pa/factory set: 15 Pa for FXDQ-NB models.
Only 200 mm in height, this model can be installed in rooms with
as little as 240 mm depth between the drop-ceiling and ceiling
slab.
Only 700 mm in width and 23 kg in weight, this model is suitable
to install in limited spaces like drop-ceilings in hotels.
Low operation sound level (dB(A))
* The values of operation sound level represent those for
rear-suction operation.Sound level values for bottom-suction
operation can be obtained by adding 5 dB(A).
* Values are based on the following conditions:FXDQ-PB: external
static pressure of 10 Pa; FXDQ-NB: external static pressure of 15
Pa.
* 1,100 mm in width for the FXDQ63NB model.
200 mm900 mm
Suction grille *AIR
AIR
Discharge grille *
Air filterSuspension bolt*
240 mm
* To be obtained locally
FXDQ-PB and FXDQ-NB models are available in two types to suit
different installation conditions.FXDQ-PB/NBVE: with a drain pump
(750 mm lift) as a standard accessoryFXDQ-PB/NBVET: without a drain
pump
Only 700 mm200 mm
Great for hotel use!
Suited to use in drop-ceilings!
750 mm
Ceiling
Control of the airflow rate has been improved from 2-step to
3-step control.
FXDQ40NB/FXDQ50NB/FXDQ63NB
36/34/3236/34/32
6363
35/33/31
50
34/32/30
40
33/31/29
20/25/32Sound level
(HH/H/L)
FXDQ-PB/NB
Slim Ceiling Mounted Duct Type Ceiling Mounted Duct Type
Middle and high static pressureallows for flexible duct
design
FXMQ20P/FXMQ25P/FXMQ32PFXMQ40P/FXMQ50P/FXMQ63PFXMQ80P/FXMQ100P/FXMQ125PFXMQ140P
Built-in Drain Pump (Option)Housing the drain pump inside the
unit reduces the space required for installation.
All models are only 300 mm in height, an improvement over the
390 mm height of conventional models. The weight of the FXMQ40P has
been reduced from 44 kg to 28 kg.
A DC fan motor increases the external static pressure capacity
range to include middle to high static pressures, increasing design
flexibility.
Indoor unit
470 mm
Indoor unit
470 mm0250mm
222 mm
Without drain pump With drain pump
Simplified Static Pressure ControlExternal static pressure can
be easily adjusted using a change-over switch inside the electrical
box to meet the resistance in the duct system.
FXMQ200MA/FXMQ250MA
Drain pump is equipped as standard accessory with 700 mm
lift.
Control of the airflow rate has been improved from 2-step to
3-step control.
(dB(A))
46/45/43
140
42/40/38
63
43/41/39
80/100
41/39/37
50
39/37/35
40
34/32/30
32
33/31/29
20/25Soundlevel
(HH/H/L)
FXMQ-P
700 mm
Ceiling
30 Pa100 Pa for FXMQ20P-32P30 Pa160 Pa for FXMQ40P50 Pa200 Pa
for FXMQ50P-125P50 Pa140 Pa for FXMQ140P
Low operation sound level
Improved ease of installation
Improved ease of maintenance
Airflow rate can be controlled using a remote controller during
test operation. With the conventional model, the airflow rate was
controlled from the PC board. It is automatically adjusted to the
range between approximately 10% of the rated HH tap airflow for
FXMQ20P125P.
The drain pan can be detached for easy cleaning. An
antibacterial treatment that uses silver ions has been applied to
the drain pan, preventing the growth of slime, mould and bacteria
that cause blockages and odours.
Energy-efficientThe adopted DC fan motor is much more efficient
than the conventional AC motor, yielding an approximate 20%
decrease in energy consumption (FXMQ125P).
25 mm
44/42/40
125
VRV Indoor Units
Indoor Unit Lineup
23 24
Indo
or U
nit L
ineup
www.nhathaucodienlanh.com-0976525242
-
Stylish flat panel design harmonised with your interior dcor
Drain pan and air filter can be kept clean by mould-proof
polystyrene.
Vertical auto-swing realises efficiency of air distribution. The
louvre closes automatically when the unit stops.
5 steps of discharge angle can be set by remote controller.
Discharge angle is automatically set at the same angle as the
previous operation when restarting. (Initial setting: 10 for
cooling and 70 for heating)
Flexible installationDrain pipe can be fitted to from either
left or right sides.
FXAQ20P/FXAQ25PFXAQ32P/FXAQ40PFXAQ50P/FXAQ63P
Stylish flat panel design creates a graceful harmony that
enhances any interior space.
Flat panel can be cleaned with only the single pass of a cloth
across their smooth surface.Flat panel can also be easily removed
and washed for more thorough cleaning.
Low operation sound level
47/4147/41
6363
42/3742/37
5050
39/3439/34
4040
38/3138/31
3232
36/3136/31
2525
35/3135/31
2020
Sound level(H/L)
Sound level(H/L)
FXAQ-PFXAQ-P(dB(A))
Slim body with quiet and wide airflowAdoption of QUIET STREAM
FAN
Drain pump kit (option) can be easily incorporated.
Easy-to-clean flat designMaintenance is easier because
everything can be performed from below the unit.
Non-dew Flap with no implanted bristles
FXHQ-MA
Sound level(H/L)
Sound level(H/L)
3232
36/3136/31
6363
39/3439/34
100100
45/3745/37
(dB(A))Low operation sound level
Uses the quiet stream fan and many more advanced
technologies.
Sound absorptionmember
Turbulent flow is produced Straightening vane
Quiet stream fan
Installation is easyMaintenance is easy
Drain pump kit(built inside main unit)
600 mmBristle-free Flap minimises contamination and makes
cleaning simpler.
Non-dew Flap
100
Wide air discharge openings produce a spreading 100 airflow.
A long-life filter (maintenance free up to one year*) is
equipped as standard accessory.* 8 hr/day, 25 day/month. For dust
concentration of 0.15 mg/m3
FXHQ32MA/FXHQ63MAFXHQ100MA
Wall Mounted TypeCeiling Suspended Type
VRV Indoor Units
Drain pump kit is available as optional accessory, which lifts
the drain 1,000 mm from the bottom of the unit.
Drain pump kit
1,000 mm
Height of drain-up
Indoor unit
Indoor Unit Lineup
25 26
Indo
or U
nit L
ineup
www.nhathaucodienlanh.com-0976525242
-
Suitable for perimeter zone air conditioning
Wall hanging Floor installation
Floor Standing types can be hung on the wall for easier
cleaning. Running the piping from the back allows the unit to be
hung on walls. Cleaning under the unit, where dust tends to
accumulate, is considerably easier.
A long-life filter (maintenance free up to one year*) is
equipped as standard accessory.* 8 hr/day, 25 day/month. For dust
concentration of 0.15 mg/m3
The adoption of a fibre-less discharge grille featuring an
original design to prevent condensation also helps prevent staining
and makes cleaning easier.
Designed to be concealed in the perimeter skirting-wall
Connecting port
Refrigerant piping
* Applies also to Floor Standing type (FXLQ-MA).
The unit is concealed in skirting-wall of perimeter, that
enables to create high class interior design.
The connecting port faces downward, greatly facilitating on-site
piping work.
A long-life filter (maintenance free up to one year*) is
equipped as standard accessory.* 8 hr/day, 25 day/month. For dust
concentration of 0.15 mg/m3
FXNQ20MA/FXNQ25MAFXNQ32MA/FXNQ40MAFXNQ50MA/FXNQ63MA
FXLQ20MA/FXLQ25MAFXLQ32MA/FXLQ40MAFXLQ50MA/FXLQ63MA
Floor Standing Type
Concealed Floor Standing Type
VRV Indoor Units
Indoor Unit Lineup
FXVQ125M/FXVQ250MFXVQ200M/FXVQ400MFXVQ500M
Floor Standing Duct Type
Large air volume type for large spaces.Flexible interior design
for each tenant.
Full-scale duct connection airflow allows for air conditioning
evenly in spacious areas.
Adding the plenum chamber (option) allows for simple operation
with direct airflow.* Note that the operation sound increases by
approximately 5 dB(A).
Large airflow type that fits for spacious areas such as
factories and large stores.
Various installations can be supported from full-scale duct
connection airflow to direct airflow that allows for easy
installation.
The high static pressure type driven by the belt drive system
allows for use of air discharge outlets in various shapes as well
as long ducts. Highly flexible installation is possible.
Design with high maintainability that allows major services and
maintenance services to be performed at the front.
A long-life filter (maintenance free up to one year*) is
equipped as a standard accessory. * 8 hr/day, 26 day/month. For
dust concentration of
0.15 mg/m3
A wide range of optional accessories are available such as
high-efficiency filters.
Outdoor air intake mode is useable as an outdoor-air processing
air conditioner. *When using the unit as an outdoor-air processing
unit, there are some restrictions. Strictly follow the restrictions
specified in the Engineering Data Book.
Duct connection airflow type
Direct airflow type
FXVQ models are not available to the Hong Kong market.
27 28
Indo
or U
nit L
ineup
www.nhathaucodienlanh.com-0976525242
-
0 0
FCQ models are not available to the Hong Kong market.
www.nhathaucodienlanh.com-0976525242
-
FBQ60B41/35 dB (A)
FBQ71B41/35 dB (A)
(H/L)
The indoor unit can be installed in rooms with as little as 350
mm between the drop ceiling and ceiling slab. It also works with
both flexible and ordinary ducts.
To cope with the challenges of L-shaped or U-shaped spaces, it
is possible to install the air discharge unit away from the main
unit. This extends the possibilities for coping with human
gathering patterns or sun lighting. At the same time, different
types of architectural space can be kept comfortable.
1
3
7
11
1
23
3
4
8
9
7911
5
10
46
5
Air conditioner
Long-life filter
Air blow Air intake
425 mm or more46
5
2 2Air conditioner
Long-life filterAir blow Air intake
350 mm or more
Standard installation examples With high-efficiency filter
Ceiling return
In crawl space With canvas bellows and air intake panel (sold
separately)
45 mm
46
5
Air conditioner
Long-life filter
Air blow
Air intake450 mm or more
8
Air conditioner Ordinary duct(procured locally)Ordinary duct
(procured locally)
Air blow Air intake
460 mm or more
8
Air intake
Ceiling return with high-efficiency filter With ordinary
ducts
46
5
Air conditioner
Air blow Air intake
540 mm or more13
946
5
Air conditioner
Air blow
540 mm or more
Options
Air discharge opening adaptorDecorative panel
Canvas bellows and air intake panelFlexible ductAir discharge
grille
Air discharge opening flangeRear intake blocking pad
6
78
Air discharge chamber
Inspection panelHigh-performance filter
111213 Low-draft filter chamber
Branch ductRear intake filter chamber
1011
2
2
2
Flexible air discharge unit to fit various forms of space
Drain pump is equipped as standard accessory with 250 mm
lift.
250 mm
L-shaped room U-shaped room Long room
Low operation sound level
Slim and smooth design suits your shallow ceiling
Signals from the wireless remote controller aretransmitted to
the signal receiver.
240 mm
200 mm
Only 700 mm
CDXS-EA
Dimensions (H x W x D)WeightAirflow rate (H)External static
pressure
200 x 700 x 620 mm21 kg
8.7 m3/min30 Pa
200 x 900 x 620 mm25 kg
40 Pa
CDXS25EA CDXS35EA FDXS25C FDXS35C
9.5 m3/min 10 m3/min
FDXS2535/31/29 dB (A)
FDXS3535/31/29 dB (A)
FDXS50
37/33/31 dB (A)FDXS60
38/34/32 dB (A)
(H/L/SL)Low operation sound level
Home Leave Operation prevents large rises or falls in the indoor
temperature by continuing operation* while you are sleeping or out
of your home. This means that an air-conditioned welcome awaits
when you wake or return. It also means that the indoor temperature
can quickly return to your favourite comfort setting.
Models in the CDXS-EA series are only 700 mm in width and 21 kg
in weight, so are easily installed in limited spaces. Just 200 mm
in height, all models can be installed in rooms with as little as
240 mm depth between the drop ceiling and ceiling slab, making them
ideal for even shallow ceilings.
Notes: 1. To prevent an increase in operation noise, avoid
installing the air suction grille directly below the suction
chamber.
2. Grilles, piping connections, ducts, and installation parts
should be obtained locally. Slim Ceiling Mounted Duct type FDKS
models do not have drain-up pumps.
3. The signal receiver unit must be located near the air suction
inlet, because the unit includes a sensor that detects room
temperature.
Suction grille (KDGF19A45)
Option
* Locally obtained partsAIRAir suction grille*
Suction duct*
Signal receiver
Air discharge duct* Suspension bolt*Air discharge grille*
Signal receiver wireLength = 1,900 mm
Chamber
AIR
Air filter
* Home Leave Operation can be selected for any temperature from
18 to 32C for cooling operation and 10 to 30C for heating
operation.
* Home Leave Operation function must be set using the remote
controller when going to sleep or leaving the house, and after
waking up or returning home.
Standard accessoryNote: Remote controllers other than the
standard accessory wireless remote controller cannot be used.
Great for hotel use!
Ceiling Mounted Built-in Type Slim Ceiling Mounted Duct Type
700 mm width type
900/1,1000 mm width type
CDXS25EA/CDXS35EA
FDXS25C/FDXS35CFDXS50C/FDXS60C
FBQ60B/FBQ71B
VRV Indoor UnitsResidential Indoor Units with connection to BP
units
Indoor Unit Lineup
Note: Remote controller cables not included. Cables should
beobtained locally.
Option
CDXS25 CDXS35
FBQ models are not available to the HongKong market.
The indoor unit can be installed in rooms with as little as 350
mm between the drop ceiling and ceiling slab.It also works with
both flexible and ordinary ducts.
11
3
8
7911
46
5
Air conditioner
Long-life filter
Air blow Air intake
425 mm or more46
5
2 2Air conditioner
Long-life filterAir blow Air intake
350 mm or more
Standard installation examples
Ceiling return
In crawl space With canvas bellows and air intake panel (sold
separately)
45 mm
46
5
Air conditioner
Long-life filter
Air blow
Air intake450 mm or more
8
Air conditioner Ordinary duct(procured locally)Ordinary duct
(procured locally)
Air blow Air intake
460 mm or more
8
Air intake
Ceiling return with high-efficiency filter With ordinary
ducts
946
5
Air conditioner
Air blow
540 mm or more
1011
2
3
7
1
With high-efficiency filter
46
5
Air conditioner
Air blow Air intake
540 mm or more13
2
2
Options2 Air discharge opening adaptor1 Decorative panel
3 Canvas bellows and air intake panel 9 Rear intake blocking
pad8 Inspection panel7 High-performance filter 10 Air discharge
opening flange
13 Low-draft filter chamber12 Branch duct11 Rear intake filter
chamber
4 Flexible duct5 Air discharge grille6 Air discharge chamber
31 32
Indo
or U
nit L
ineup
www.nhathaucodienlanh.com-0976525242
-
Wall Mounted indoor units achieve quiet sound levels of 22 dB
(A) during cooling operation.
Intelligent Eye with its infrared sensor automatically controls
air conditioner operation according to human movement in a room.
When there is no movement, it adjusts the temperature by 2C for
energy savings.
3-D Airflow combines Vertical and Horizontal Auto-Swing to
circulate air to every part of a room for uniform cooling of even
large spaces.* This function is available for
FTXS50/60/71F.
FTXS20/2537/25/22 dB (A)
FTXS3539/26/23 dB (A)
FTXS5043/34/31 dB (A)
FTXS6045/36/33 dB (A)
FTXS7146/37/34 dB (A)
(H/L/SL)
When you are in the room When you go out
A uniform temperatureis achieved throughout the entire room.
Stylish flat panel harmonises with your interior dcor
* Remote controllers other than the standard accessory wireless
remote controller cannot be used.
Standard accessory*
Standardaccessory*
Wall Mounted Type
FTXS20D/FTXS25E/FTXS35E
FTXS50F/FTXS60F/FTXS71F
Residential Indoor Units with connection to BP units
Indoor Unit Lineup
Ceiling Mounted Cassette (Round Flow with Sensing) Type
VRV Indoor Units
Fresh white50950950
5.5
Galvanised steel plate
7.16,90027,300
8.0
9.08,60034,100
10.0
11.210,80042,70012.5
14.013,80054,60016.0
24,200 30,700 38,200 47,800 6,100 7,700 9,600 12,000
1-phase, 220-240 V/220-230 V, 50/60 HzFXFQ63SVM FXFQ80SVM
FXFQ100SVM FXFQ125SVM
BYCQ125B-W1
Fresh white50950950
5.5
19 23246840840
441/406/353 441/406/353 512/459/388 777/618/47730/28.5/27
30/28.5/27 31/29/27 36/32/28
12.5/11.5/10.0 12.5/11.5/10.0 14.5/13.0/11.0 22.0/17.5/13.5
246840840 288840840
830/653/477 830/688/530 1,165/918/671 1,218/971/74138/33/28
38/35/31 44/38/32 45/40/35
23.5/18.5/13.5 23.5/19.5/15.0 33.0/26.0/19.0 34.5/27.5/21.0
Galvanised steel plate
0.0310.027
0.0410.037
0.0310.027
0.0800.075
2.82,80010,900
3.2
3.63,40013,600
4.0
4.54,300
17,1005.0
5.65,400
21,5006.3
9,600 12,300 15,400 19,100 2,400 3,100 3,900 4,800
1-phase, 220-240 V/220-230 V, 50/60 HzFXFQ25SVM FXFQ32SVM
FXFQ40SVM FXFQ50SVM
6.412.7
I.D. 25O.D. 32(VP25)BYCQ125B-W1
9.515.9
I.D. 25O.D. 32(VP25)
0.0950.090
0.1940.180
0.0950.090
0.2190.199
23 26
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB,
Equivalent piping length: 7.5 m, Level difference: 0 m. Heating:
Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping
length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity
of indoor unit is based on the total capacity index. (See
Engineering Data Book for details.)
Sound level: Anechoic chamber conversion value, measured at a
point 1.5 m downward from the unit centre.
Titanium apatite is a photocatalytic material with high
adsorption power. Titanium apatite also effectively adsorbs and
decomposes bacteria across its entire surface. The photocatalyst is
activated simply by exposure to light.
These filters are not medical devices. Benefits such as the
adsorption and decomposition of bacteria are only effective for
substances that are collected on and in direct contact with the
Titanium Apatite Photocatalytic Air-Purifying Filter.Bacteria
Removal TestTesting method: dropping methodResult certificate: No.
012553-1 and 012553-2Testing organisation: Japan Spinners
Inspecting Foundation
Titanium Apatite Photocatalytic Air-purifying Filter
Air filterCatches dust
cfmdB(A)mmkg
mm
mmkg
kcal/hBtu/hkW
kcal/hBtu/hkWkWkW
m3/min
Liquid (Flare)Gas (Flare)DrainModelColour
Dimensions(HWD)Weight
PowerconsumptionCasing
Sound level (H/M/L)
Airflow rate (H/M/L)
Dimensions (HWD)Machine weight
Piping connections
Panel(Option)
Power supply
Heating capacity
Cooling capacity
MODEL
Cooling
Heating
cfmdB(A)mmkg
mm
mmkg
kcal/hBtu/hkW
kcal/hBtu/hkWkWkW
m3/min
Liquid (Flare)Gas (Flare)DrainModelColour
Dimensions(HWD)Weight
PowerconsumptionCasing
Sound level (H/M/L)Dimensions (HWD)Machine weight
Piping connections
Panel(Option)
Power supply
Heating capacity
Cooling capacity
MODEL
Cooling
Heating
Airflow rate (H/M/L)
33 34
Spec
ificat
ions
www.nhathaucodienlanh.com-0976525242
-
Ceiling Mounted Cassette (Round Flow) Type
1-phase, 220-240 V, 50 Hz2,4009,6002.8
2,80010,900
3.20.0330.027
3,10012,300
3.63,400
13,6004.0
0.0330.027
3,90015,400
4.54,300
17,1005.0
0.0470.034
4,80019,100
5.65,400
21,5006.3
0.0520.038
13/11.5/10459/406/35330/28.5/27
246X840X84019.5
15/13/11530/459/388
31/29/27246X840X840
19.5
16/13.5/11565/477/38832/29.5/27
246X840X84019.5
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB,
Equivalent piping length: 7.5m, Level difference: 0m.
Capacity of indoor unit is only for reference. Actual capacity
of indoor unit is based on the total capacity index. (See
Engineering Data Bookfor details.)
Sound level: Anechoic chamber conversion value, measured at a
point 1.5m downward from the unit centre.
FXFQ25LUV1 FXFQ32LUV1 FXFQ40LUV1 FXFQ50LUV1
1-phase, 220-240 V, 50 Hz6,100 7,700 9,600 12,000
24,200 30,700 38,200 47,8007.1 9.0 11.2 14.0
6,90027,300
8.00.0660.053
8,60034,10010.0
0.0930.075
10,80042,70012.5
0.1870.174
13,80054,60016.0
0.2090.200
Galvanised steel plate
Galvanised steel plate
19/16.5/13.5671/583/477
34/31/28246X840X840
22
32/26/201,130/918/706
43/37.5/32288X840X840
25
33/28/22.51,165/989/794
44/39/34288X840X840
25
21/18/15742/636/53036/33.5/31
246X840X84022
9.515.9
VP25 (External Dia, 32/Internal Dia, 25)BYCP125K-W1
Fresh white50X950X950
5.5
FXFQ63LUV1 FXFQ80LUV1 FXFQ100LUV1 FXFQ125LUV1
VRV Indoor Units
Ceiling Mounted Cassette (Compact Multi Flow) Type
4-way Flow Ceiling Suspended Type
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB,
Equivalent piping length: 7.5m, Level difference: 0m.
Capacity of indoor unit is only for reference. Actual capacity
of indoor unit is based on the total capacity index. (See
Engineering Data Book ference: 0m. for details.)
Sound level: Anechoic chamber conversion value, measured at a
point 1.5m downward from the unit centre. During actual operation,
these values are normally somewhat higher as a result of ambient
conditions.
1-phase, 220-240 V/220 V, 50/60 Hz1,9007,500
2.22,2008,500
2.5
2,4009,600
2.82,80010,900
3.2
3,10012,300
3.63,40013,600
4.00.0760.068
3,90015,400
4.54,300
17,1005.0
0.0890.080
4,80019,100
5.65,400
21,5006.3
0.1150.107
Galvanised steel plate9/7 9.5/7.5 11/8 14/10
318/247 335/265 388/282 493/353
30/25-32/26 30/25-32/26 32/26-34/28 36/28-37/29 41/33-42/35
286575575186.412.7
VP20 (External Dia, 26/Internal Dia, 20)BYFQ60B8W1
White (6.5Y9.5/0.5)55700700
2.7
FXZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ50MVEFXZQ40MVE
1-phase, 220-240 V/220-230 V, 50/60 Hz6,900 9,600
27,300 38,2008.0
7,70030,700
9.00.0900.073
11.210,80042,70012.5
0.2000.179
Fresh white22.5/19.5/16 31/26/21794/688/565 1,094/918/741
40/38/36 47/44/40198950950
26 279.515.9
VP20 (External Dia, 26/Internal Dia, 20)
FXUQ71AVEB FXUQ100AVEB
Spec
ificat
ions
0.0730.064
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB,
Equivalent piping length: 7.5m, Level difference: 0m. Heating:
Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping
length: 7.5m, Level difference: 0m.
246X840X84019.5 6.4
12.7VP25 (External Dia, 32/Internal Dia, 25)
BYCP125K-W1Fresh white
50X950X9505.5
246X840X84019.5 6.4
12.7
15/13/1113/11.5/10 13/11.5/10
30/28.5/27 30/28.5/27530/459/388
31/29/27246X840X840
19.5 6.4
12.7
16/13.5/11565/477/388459/406/353 459/406/35332/29.5/27
246X840X84019.5 6.4
12.7
19/16.5/13.5671/583/477
34/31/28246X840X840
22 9.5
15.9
21/18/15742/636/53036/33.5/31
246X840X84022
9.5 15.9
32/26/201,130/918/706
43/37.5/32288X840X840
25 9.5 15.9
33/28/22.51,165/989/794
44/39/34288X840X840
25 9.5 15.9
VP25 (External Dia, 32/Internal Dia, 25)BYCP125K-W1
Fresh white50X950X950
5.5
13/11.5/10459/406/35330/28.5/27
246X840X84019.56.412.7
13/11.5/10459/406/35330/28.5/27
246X840X84019.5
15/13/11530/459/388
31/29/27246X840X840
19.5
16/13.5/11565/477/38832/29.5/27
246X840X84019.5
6.412.7
VP25 (External Dia, 32/Internal Dia, 25)BYCP125K-W1
Fresh white50X950X950
5.5
13/11.5/10459/406/35330/28.5/27
246X840X84019.5
19/16.5/13.5671/583/477
34/31/28246X840X840
22
21/18/15742/636/53036/33.5/31
246X840X84022
32/26/201,130/918/706
43/37.5/32288X840X840
25
33/28/22.51,165/989/794
44/39/34288X840X840
25
cfm
dB(A)
mmkg
mm
mmkg
kcal/hBtu/hkW
kcal/hBtu/hkWkWkW
m3/min
Liquid (Flare)Gas
(Flare)DrainModelColourDimensions(HWD)Weight
PowerconsumptionCasing
Dimensions (HWD)Machine weight
Piping connections
Panel(Option)
Power supply
Heating capacity
Cooling capacity
MODEL
CoolingHeating
cfmdB(A)mmkg
mm
kcal/hBtu/hkW
kcal/hBtu/hkWkWkW
m3/min
Liquid (Flare)Gas (Flare)Drain
PowerconsumptionCasing
Sound level (H/M/L)Dimensions (HWD)Machine weight
Piping connections
Power supply
Heating capacity
Cooling capacity
MODEL
CoolingHeatingcfm
dB(A)mmkg
mm
mmkg
kcal/hBtu/hkW
kcal/hBtu/hkWkWkW
m3/min
Liquid (Flare)Gas
(Flare)DrainModelColourDimensions(HWD)Weight
PowerconsumptionCasing
Sound level (HH/M/L)Dimensions (HWD)Machine weight
Piping connections
Panel(Option)
Power supply
Heating capacity
Cooling capacity
MODEL
CoolingHeating
cfmdB(A)mmkg
mm
mmkg
kcal/hBtu/hkW
kcal/hBtu/hkWkWkW
m3/min
Liquid (Flare)Gas
(Flare)DrainModelColourDimensions(HWD)Weight
PowerconsumptionCasing
Sound level (HH/M/L)Dimensions (HWD)Machine weight
Piping connections
Panel(Option)
Power supply
Heating capacity
Cooling capacity
MODEL
CoolingHeating
Airflow rate (H/L)
Airflow rate (H/M/L)
Airflow rate (HH/M/L)
Airflow rate (HH/M/L)
Sound level (H/L) 230 V-240 V
35 36
Specifications
www.nhathaucodienlanh.com-0976525242
-
A single outdoor unit capacity ranges from 8 HP to 22 HP in
increment of 2 HP, and the capacity of a triple outdoor unit system
is up to 66 HP.
Large capacity unit
VRV Indoor Units
Specifications
Ceiling Mounted Cassette (Double Flow) Type
Ceiling Mounted Cassette Corner Type
FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE
FXCQ80MVE FXCQ125MVE1-phase, 220-240 V/220 V, 50/60 Hz
1,900 2,400 3,100 3,900 4,800 6,100 7,700 12,0007,500 9,600
12,300 15,400 19,100 24,200 30,700 47,800
2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.02,2008,5002.5
0.0770.044
2,80010,900
3.20.0920.059
3,40013,600
4.00.0920.059
4,30017,100
5.00.1300.097
5,40021,500
6.30.1300.097
6,90027,300
8.00.1610.126
8,60034,10010.0
0.2090.176
13,80054,60016.0
0.2560.223
Galvanised steel plate7/5 9/6.5 9/6.5 12/9 12/9 16.5/13 26/21
33/25
247/177 318/230 318/230 424/318 424/318 582/459 918/741
1,165/88332/27 34/28 34/28 34/29 34/29 37/32 39/34 44/38
305775600 305775600 305775600 305990600 305990600 3051,175600
3051,665600 3051,66560026.0 26.0 26.0 31.0 32.0 35.0 47.0 48.06.4
6.4 6.4 6.4 6.4 9.5 9.5 9.512.7 12.7 12.7 12.7 12.7 15.9 15.9
15.9
VP25 (External Dia, 32/Internal Dia, 25)BYBC32G-W1 BYBC50G-W1
BYBC63G-W1 BYBC125G-W1
White (10Y9/0.5)531,030680 531,030680 531,030680 531,245680
531,245680 531,430680 531,920680 531,920680
8.0 8.0 8.0 8.5 8.5 9.5 12.0 12.0 Cooling: Indoor temp.: 27CDB,
19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level
difference: 0 m. Capacity of indoor unit is only for reference.
Actual capacity of indoor unit is based on the total capacity
index.
(See Engineering Data Book ference: 0 m.for details.) Sound
level: Anechoic chamber conversion value, measured at a point 1.5 m
downward from the unit centre. During actual operation, these
values are normally somewhat higher as a result of ambient
conditions.
FXKQ25MAVE
9,6002,400
Galvanised steel plate11/9
FXKQ32MAVE
12,3003,100
FXKQ40MAVE
15,4003,900
FXKQ63MAVE
2.8 3.6 4.5 7.124,2006,100
11/9 13/10 18/15388/318 388/318 459/353 635/530
215X1,110X71031
6.4 12.7
VP25 (External Dia, 32/Internal Dia, 25)BYK45FJW1
White (10Y9/0.5)70X1,240X800
8.5
215X1,110X71031
6.4 12.7
70X1,240X8008.5
215X1,110X71031
6.4 12.7
70X1,240X8008.5
215X1,310X71034
9.5 15.9
BYK71FJW1
70X1,440X8009.5
38/33 38/33 40/34 42/3740/35 40/35 42/36 44/39
1-phase, 220-240 V/220 V, 50/60 Hz
Note: Specifications are based on the following
conditions;Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.:
35CDB, Equivalent piping length: 7.5m, Level difference: 0m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB,
Equivalent piping length: 7.5m, Level difference: 0m.Capacity of
indoor unit is only for reference. Actual capacity of indoor unit
is based on the total capacity index. (See Engineering Data Book
for details.)Sound level: (FXCQ-M) Anechoic chamber conversion
value, measured at a point 1.5 m downward from the unit centre.
(FXKQ-MA) Anechoic chamber conversion value, measured at a point
1 m in front of the unit and 1 m downward. During actual operation,
these values are normally somewhat higher as a result of ambient
conditions.
Slim Ceiling Mounted Duct Type (700 mm width type)
Slim Ceiling Mounted Duct Type (900/1,100 mm width type)
FXDQ20PBVE FXDQ25PBVE FXDQ32PBVEFXDQ20PBVET FXDQ25PBVET
FXDQ32PBVET
FXDQ40NBVEFXDQ40NBVET
FXDQ50NBVEFXDQ50NBVET
FXDQ63NBVEFXDQ63NBVET
1-phase, 220-240 V/220 V, 50/60 Hz1,9007,500
2.22,2008,500
2.5
2,400 3,10012,300
3.63,400
13,6004.0
0.070
0.070
9,6002.8
2,80010,900
3.2
0.067
0.067
0.0860.0670.0670.067
0.086 0.089
0.067 0.070
Galvanised steel plate8.0/7.2/6.4 8.0/7.2/6.4 8.0/7.2/6.4
282/254/226 282/254/226 282/254/22630-10 1
33/31/29 33/31/29 33/31/29200700620 200700620 200700620
23.0 23.0 23.06.4 6.4 6.412.7 12.7 12.7
VP20 (External Dia, 26/Internal Dia, 20)
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB,
Equivalent piping length: 7.5m, Level difference: 0m.Capacity of
indoor unit is only for reference. Actual capacity of indoor unit
is based on the total capacity index. (See Engineering Data Book
for details.)
1-phase, 220-240 V/220 V, 50/60 Hz3,900 4,800 6,10015,400 19,100
24,200
4.54,30017,100
5.0
0.1470.1470.147
5.65,40021,500
6.30.1650.1520.1520.152
7.16,900
27,3008.0
0.1810.1680.1680.168
0.160
Galvanised steel plate10.5/9.5/8.5 12.5/11.0/10.0
16.5/14.5/13.0371/335/300 441/388/353 583/512/459
44-1534/32/30 35/33/31 36/34/32
200900620 200900620 2001,10062027.0 28.0 31.06.4 6.4 6.412.7
12.7 12.7
VP20 (External Dia, 26/Internal Dia, 20)
Note: Specifications are based on the following
conditions;Cooling: (*1) Indoor temp.: 27CDB, 19.5CWB, Outdoor
temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0
m. (*2) Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB,
Equivalent piping length: 7.5 m, Level difference: 0 m. Heating:
Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping
length: 7.5 m, Level difference: 0 m. Capacity of indoor unit is
only for reference. Actual capacity of indoor unit is based on the
total capacity index. (See Engineering Data Book for details.)Sound
level: Anechoic chamber conversion value, measured at a point 1.5 m
downward from the unit centre. During actual operation, these
values are normally somewhat higher as a result of ambient
conditions. 1 : External static pressure is changeable to set by
the remote controller. This pressure means "High static pressure -
Standard". (Factory setting is 10 Pa for FXDQ-PB models and 15 Pa
for FXDQ-NB models.) 2: The values of operation sound level
represent those for rear-suction operation. Sound level values for
bottom-suction operation can be obtained by adding 5 dB(A). 3:
Values are based on the following conditions: FXDQ-PB: external
static pressure of 10 Pa; FXDQ-NB: external static pressure of 15
Pa.
Sound level: Anechoic chamber conversion value, measured at a
point 1.5 m downward from the unit centre. During actual operation,
these values are normally somewhat higher as a result of ambient
conditions. 1 : External static pressure is changeable to set by
the remote controller. This pressure means "High static pressure -
Standard". (Factory setting is 10 Pa for FXDQ-PB models and 15 Pa
for FXDQ-NB models.) 2: The values of operation sound level
represent those for rear-suction operation. Sound level values for
bottom-suction operation can be obtained by adding 5 dB(A). 3:
Values are based on the following conditions: FXDQ-PB: external
static pressure of 10 Pa; FXDQ-NB: external static pressure of 15
Pa.
Spec
ificat
ions
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB,
Equivalent piping length: 7.5 m, Level difference: 0 m.
2,80010,900
3.20.0660.046
3,40013,600
4.00.0660.046
4,30017,100
5.00.0760.056
6,90027,300
8.00.1050.085
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB,
Equivalent piping length: 7.5m, Level difference: 0m.
1
cfmPa
dB(A)mmkg
mm
kcal/hBtu/hkW
kcal/hBtu/hkWkWkWkWkW
m3/min
Liquid (Flare)Gas (Flare)Drain
Power consumption(FXDQ-PBVET)
Power consumption(FXDQ-PBVE)
Casing
Dimensions (HWD)Machine weight
Piping connections
Power supply
Heating capacity
Cooling capacity
MODEL
CoolingHeating
CoolingHeating
with drain pumpwithout drain pump
External static pressureSound level (HH/H/L)
cfmPa
dB(A)mmkg
mm
kcal/hBtu/hkW
kcal/hBtu/hkWkWkWkWkW
m3/min
Liquid (Flare)Gas (Flare)Drain
Power consumption(FXDQ-PBVET)
Power consumption(FXDQ-PBVE)
Casing
Dimensions (HWD)Machine weight
Piping connections
Power supply
Heating capacity
Cooling capacity
MODEL
CoolingHeating
CoolingHeating
with drain pumpwithout drain pump
External static pressureSound level (HH/H/L)
cfmdB(A)mmkg
mm
mmkg
kcal/hBtu/hkW
kcal/hBtu/hkWkWkW
m3/min
Liquid (Flare)Gas
(Flare)DrainModelColourDimensions(HWD)Weight
PowerconsumptionCasing
Sound level (H/L)Dimensions (HWD)Machine weight
Piping connections
Panel(Option)
Power supply
Heating capacity
Cooling capacity
MODEL
CoolingHeating
cfm
mmkg
mm
mmkg
kcal/hBtu/h
kcal/hBtu/hkWkWkW
m3/min
Liquid (Flare)Gas
(Flare)DrainModelColourDimensions(HWD)Weight
PowerconsumptionCasing
Sound level (H/L)
Dimensions (HWD)Machine weight
Piping connections
Panel(Option)
Power supply
Heating capacity
Cooling capacity
MODEL
CoolingHeating
kW
220 V240 V
dB(A)
Airflow rate (H/L)
Airflow rate (HH/M/L)
Airflow rate (HH/H/L)
Airflow rate (HH/H/L)
2 3
2 3
37 38www.nhathaucodienlanh.com-0976525242
-
VRV Indoor Units
Specifications
Ceiling Mounted Duct Type
Note: Specifications are based on the following
conditions;Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.:
35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB,
Equivalent piping length: 7.5 m, Level difference: 0 m.Capacity of
indoor unit is only for reference. Actual capacity of indoor unit
is based on the total capacity index. (See Engineering Data Book
for details.)Sound level: Anechoic chamber conversion value,
measured at a point 1.5 m downward from the unit centre. During
actual operation, these values are normally somewhat higher as a
result of ambient conditions. 1: External static pressure can be
modified using a remote controller that offers seven (FXMQ20-32P),
thirteen (FXMQ40P), fourteen (FXMQ50-
125P) or ten (FXMQ140P) levels of control. These values indicate
the lowest and highest possible static pressures. The standard
static pressure is 50 Pa for FXMQ20-32P and 100 Pa for
FXMQ40-140P.
FXMQ40PVE FXMQ50PVE
15,4003,900
Galvanised steel plate
565/459/388
300X700X70028
VP25 (External Dia, 32/Internal Dia, 25)
19,1004,800
635/582/530
300X1,000X70036
4.5 5.6
1-phase, 220-240 V/220 V, 50/60 Hz
6.4 12.7
6.4 12.7
16/13/11 18/16.5/15
30-160 50-2001 139/37/35
7,5001,900
318/265/230
300X550X70025
2.2
6.4 12.7
9/7.5/6.5
30-10033/31/29
FXMQ25PVE
9,6002,400
318/265/230
300X550X70025
2.8
6.4 12.7
9/7.5/6.5
30-10033/31/29
FXMQ32PVE
12,3003,100
335/282/247
300X550X70025
3.6
6.4 12.7
9.5/8/7
30-10034/32/30 41/39/37
1 1 1
FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE
Galvanised steel plate
VP25 (External Dia, 32/Internal Dia, 25)
24,2006,100
688/618/565
300X1,000X70036
9.5 15.9
30,7007,700
883/794/706
300X1,000X70036
9.5 15.9
38,2009,600
1,130/953/812
300X1,400X70046
9.5 15.9
47,80012,000
1,377/1,165/988
300X1,400X70046
9.5 15.9
7.1 9.0 11.2 14.0
1-phase, 220-240 V/220 V, 50/60 Hz
19.5/17.5/16 25/22.5/20 32/27/23 39/33/28
50-200 50-200 50-200 50-200 1 1 1 1 1
42/40/38 43/41/39 43/41/39 44/42/40
FXMQ140PVE
54,60013,800
1,624/1,377/1,130
300X1,400X70047
9.5 15.9
16.0
46/39/32
50-140 46/45/43
1
Ceiling Mounted Duct Type
Ceiling Suspended TypeFXHQ32MAVE FXHQ63MAVE FXHQ100MAVE
1-phase, 220-240 V/220 V, 50/60 Hz3,100 6,100 9,60012,300 24,200
38,200
3.6 7.1 11.23,40013,600
4.00.1110.111
6,90027,300
8.00.1150.115
10,80042,70012.5
0.1350.135
White (10Y9/0.5)12/10 17.5/14 25/19.5
424/353 618/494 883/68836/31 39/34 45/37
195960680 1951,160680 1951,40068024.0 28.0 33.06.4 9.5 9.512.7
15.9 15.9
VP20 (External Dia, 26/Internal Dia, 20)
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB,
Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity
of indoor unit is based on the total capacity index. (See
Engineering Data Book for details.)
Sound level: (FXMQ-MA) Anechoic chamber conversion value,
measured at a point 1.5 m downward from the unit centre. (FXHQ-MA)
Anechoic chamber conversion value, measured at a point 1 m in front
of the unit and 1 m downward. During actual operation, these values
are normally somewhat higher as a result of ambient conditions 1 :
External static pressure is changeable to change over the
connectors inside electrical box, this pressure means
"Standard-High static pressure".
FXMQ200MAVE FXMQ250MAVE
76,40019,300
22.4 28.095,50024,100
1-phase, 220-240 V/220 V, 50/60 Hz
Galvanised steel plate58/50
2,047/1,765
470X1,380X1,100137 9.5
19.1PS1B
72/622,542/2,189
470X1,380X1,100137 9.5
22.2
132-221 191-270 1 148/45 48/4549/46 49/46
Spec
ificat
ions
FXMQ20PVE
2,2008,500
2.50.0810.069
6,90027,300
8.00.2300.218
8,60034,100
10.00.2980.286
10,80042,700
12.50.3760.364
13,80054,600
16.00.4610.449
15,50061,400
18.00.4610.449
2,80010,900
3.20.0810.069
3,40013,600
4.00.0850.073
4,30017,100
5.00.1940.182
5,40021,500
6.30.2150.203
21,50085,30025.01.2941.294
27,100107,500
31.51.4651.465
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB,
Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB,
Equivalent piping length: 7.5 m, Level difference: 0 m.
cfmPa
dB(A)mmkg
mm
kcal/hBtu/hkW
kcal/hBtu/hkWkWkW
m3/min
Liquid (Flare)Gas (Flare)Drain
Power consumption
Casing
Dimensions (HWD)Machine weight
Piping connections
Power supply
Heating capacity
Cooling capacity
MODEL
CoolingHeating
External static pressureSound level (HH/H/L)
cfmPa
mmkg
mm
kcal/hBtu/hkW
kcal/hBtu/hkWkWkW
m3/min
Liquid (Flare)Gas (Flare)Drain
Power consumption
Casing
Dimensions (HWD)Machine weight
Piping connections
Power supply
Heating capacity
Cooling capacity
MODEL
CoolingHeating
External static pressureSound level(H/L)
cfmdB(A)mmkg
mm
kcal/hBtu/hkW
kcal/hBtu/hkWkWkW
m3/min
Liquid (Flare)Gas (Flare)Drain
Power consumption
Casing
Dimensions (HWD)Machine weight
Piping connections
Power supply
Heating capacity
Cooling capacity
MODEL
CoolingHeating
Sound level (H/L)
cfmPa
dB(A)mmkg
mm
kcal/hBtu/hkW
kcal/hBtu/hkWkWkW
m3/min
Liquid (Flare)Gas (Flare)Drain
Power consumption
Casing
Dimensions (HWD)Machine weight
Piping connections
Power supply
Heating capacity
Cooling capacity
MODEL
CoolingHeating
External static pressureSound level (HH/H/L)
220 V240 V
dB(A)
Airflow rate (H/L)
Airflow rate (H/L)
Airflow rate (HH/H/L)
Airflow rate (HH/H/L)
39 40www.nhathaucodienlanh.com-0976525242
-
Residential indoor units with connection to BP units
VRV Indoor Units
Specifications
Wall Mounted Type
Floor Standing Type/Concealed Floor Standing Type
FXLQ
FXNQ
Floor Standing Duct Type
Ceiling Mounted Cassette Type
Spec
ificat
ions
*FXVQ models are not available to the Hong Kong market.
*FCQ models are not available to the Hong Kong market.
41 42
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB,
Equivalent piping length: 7.5 m, Level difference: 0 m.Heating:
Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping
length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity
of indoor unit is based on the total capacity index. (See
Engineering Data Bookfor details.)
Sound level: (FXAQ-P) Anechoic chamber conversion value,
measured at a point 1 m in front of the unit and 1 m
downward.(FXLQ-MA, FXNQ-MA) Anechoic chamber conversion value,
measured at a point 1.5 m in front of the unit at a height of 1.5
m.During actual operation, these values are normally somewhat
higher as a result of ambient conditions.
Rp1 (PS 1B internal thread)Long-life filter (anti-mould resin
net)
Belt drive system
3-phase 4-wire system, 380415 V, 50 Hz
Ivory white (5Y7.5/1)
FXVQ125MY1
1,67075051011552
15.9 (Brazing)
FXVQ250MY1 FXVQ400MY1
1,9001,47072027061
1,9001,17072022564
12.7 (Brazing) 28.6 (Brazing)
FXVQ200MY1
0.590.59
12,00047,80014.0
13,80054,60016.0
19,30076,40022.4
21,50085,30025.0
24,10095,50028.0
27,100107,500
31.5
38,700154,000
45.043,000171,000
48,200191,000
1.681.68
50.03.973.97
2.622.62
1.411.41
1,6701,17051016559
22.2 (Brazing)
1,67095051014055
9.5 (Brazing) 19.1 (Brazing)
FXVQ500MY1
5.5172480
5.025.02
FXVQ500MY16
1-phase, 220-240 V/220 V, 50/60 Hz
2 steps
FCQ71BVE
35/3019.0 (671)
9.515.9
FCQ60BVEFCQ50BVE
15.0 (530)
12.7
FCQ35BVE
33/2914.0 (494)
6.49.5
MODELPower supply
Both liquid and gas pipesHeat insulation
Fan speedMicrocomputer control
I.D 25XO.D 32
230X840X840Temperature control
Airflow rates (H)Sound levels (H/L)* dB (A)
m3/min (cfm)
Dimensions (HXWXD) mm24Machine weight kg
40X950X950
BYC125K-W1White
mm5kg
Pipingconnections
Panel(Option)
Drain
Liquid (Flare)
ModelColourDimensions (HXWXD)Weight
Gas (Flare) mm
Note: * For 220 V operation.
56.054,200215,000
63.0
15.9 (Brazing) 28.6 (Brazing)
0.7543150
1.569210
1.586270
3.7134380
3.7165125
29567
Notes: Specifications are based on the following
conditions;Cooling : Indoor temp. of 27CDB, 19CWB, and outdoor
temp. of 35CDB.Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB,
6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. *1
Sound level : measured when the air discharge outlet duct (2 m) is
attached (anechoic chamber conversion value). It increases by
approximately 5 dB(A) when the plenum chamber is installed to
deliver direct airflow.*2 The value is the external static pressure
with standard pulley.
mmkg
dB(A)mmmmmm
kWm3/min
Pa
kcal/hBtu/hkW
kcal/hBtu/hkWkWkW
LiquidGasDrainTypeMotor outputAirflow rateExternal static
pressure *2Drive system
PowerconsumptionCasing colour
Sound level *1
Dimensions (HWD)Machine weight
Piping connections
Power supply
Heating capacity
Cooling capacity
MODEL
CoolingHeating
Air filter
Fan
FXAQ20PVE FXAQ25PVE FXAQ32PVE FXAQ40PVE FXAQ50PVE
FXAQ63PVE1-phase, 220-240 V/220 V, 50/60 Hz
1,900 2,400 3,100 3,900 4,800 6,1007,500 9,600 12,300 15,400
19,100 24,2002.2 2.8 3.6 4.5 5.6 7.1
2,2008,5002.5
0.0190.029
2,80010,900
3.20.0280.034
3,40013,600
4.00.0300.035
4,30017,100
5.00.0200.020
5,40021,500
6.30.0330.039
6,90027,300
8.00.0500.060
2,2008,5002.5
0.0490.049
2,80010,900
3.20.0490.049
3,40013,600
4.00.0900.090
4,30017,100
5.00.0900.090
5,40021,500
6.30.1100.110
6,90027,300
8.00.1100.110
White (3.0Y8.5/0.5)7.5/4.5 8/5 8.5/5.5 12/9 15/12 19/14
265/159 282/177 300/194 424/318 530/424 671/49435/31 36/31 38/31
42/3739/34 47/41
290795238 290795238 290795238 2901,050238 2901,050238
2901,05023811.0 11.0 11.0 14.0 14.0 14.06.4 6.4 6.4 6.4 6.4 9.512.7
12.7 12.7 12.7 12.7 15.9
VP13 (External Dia, 18/Internal Dia, 13)
FXLQ50MAVEFXNQ50MAVE
FXLQ40MAVEFXNQ40MAVE
FXLQ32MAVEFXNQ32MAVE
FXLQ25MAVEFXNQ25MAVE
FXLQ20MAVEFXNQ20MAVE
FXLQ63MAVEFXNQ63MAVE
1-phase, 220-240 V/220 V, 50/60 Hz1,900 2,400 3,100 3,900 4,800
6,1007,500 9,600 12,300 15,400 19,100 24,2002.2 2.8 3.6 4.5 5.6
7.1
FXLQ: Ivory white (5Y7.5/1)/FXNQ: Galvanised steel plate7/6 7/6
8/6 11/8.5 14/11 16/12
247/212 247/212 282/212 388/300 494/388 565/42435/32 35/32 35/32
38/33 39/34 40/35
6001,000222 6001,000222 6001,140222 6001,140222 6001,420222
6001,420222610930220 610930220 6101,070220 6101,070220 6101,350220
6101,350220
25.0 25.0 30.0 30.0 36.0 36.019.0 19.0 23.0 23.0 27.0 27.06.4
6.4 6.4 6.4 6.4 9.512.7 12.7 12.7 12.7 12.7 15.9
VP13 (External Dia, 18/Internal Dia, 13)
cfmdB(A)mmkg
mm
kcal/hBtu/hkW
kcal/hBtu/hkWkWkW
m3/min
Liquid (Flare)Gas (Flare)Drain
Power consumption
Casing
Dimensions (HWD)Machine weight
Piping connections
Power supply
Heating capacity
Cooling capacity
MODEL
CoolingHeating
Sound level (H/L)
cfmdB(A)
mm
kcal/hBtu/hkW
kcal/hBtu/hkWkWkW
m3/min
Liquid (Flare)Gas (Flare)Drain
Power consumption
Casing
Machine weight
Piping connections
Power supply
Heating capacity