Split SkyAir VRV Packaged Air Conditioners AIR CONDITIONERS LINE UP PCG0558 The specifications, designs, and information in this brochure are subject to change without notice. All rights reserved Printed in Japan 10/05/003 Y.K. c Dealer Head Office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan Tokyo Office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global/ 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided and choose an outdoor unit with anti-corrosion treatment. Cautions on product corrosion Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorized parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. For any inquiries, contact your local distributor. All Daikin Industries locations and subsidiaries in Japan have received environmental management system standard ISO 14001 certification. The air conditioners manufactured by Daikin Industries have received ISO 9001 certification for quality assurance. Certificate Number. JMI-0107 JQA-0495 JQA-1452 Daikin Industries, Ltd. Domestic Group Certificate Number. EC99J2044 ISO 14001 is the standard defined by the International Organization for Standardization (ISO) relating to environmental management systems. Our group has been acknowledged by an internationally accredited compliance organisation as having an appropriate programme of environmental protection procedures and activities to meet the requirements of ISO 14001. About ISO 14001
this is the Original Daikin Catalogs for VRV Splits, and Sky air products for the middle East including the specification and the Daikin Part no Daikin Middle East Middle East Cooling
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
SplitSkyAirVRV
Packaged Air Conditioners
AIR CONDITIONERSLINE UP
PCG0558
The specifications, designs, and information in this brochure are subject to change without notice.
All rights reservedPrinted in Japan 10/05/003 Y.K.c
DealerHead Office:Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:JR Shinagawa East Bldg., 2-18-1, Konan,Minato-ku, Tokyo, 108-0075 Japan
http://www.daikin.com/global/
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided and choose anoutdoor unit with anti-corrosion treatment.
Cautions on product corrosion
Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer orcontractor to install those parts and accessories. Use of unauthorized parts and accessories orimproper installation of parts and accessories can result in water or refrigerant leakage, electricalshock, fire or explosion.Read the User's Manual carefully before using this product. The User's Manual provides importantsafety instructions and warnings. Be sure to follow these instructions and warnings.
For any inquiries, contact your local distributor.
All Daikin Industries locationsand subsidiaries in Japan havereceived environmentalmanagement system standardISO 14001 certification.
The air conditioners manufacturedby Daikin Industries havereceived ISO 9001 certification forquality assurance.
ISO 14001 is the standard defined by theInternational Organization for Standardization (ISO)relating to environmental management systems.Our group has been acknowledged by aninternationally accredited compliance organisationas having an appropriate programme ofenvironmental protection procedures and activitiesto meet the requirements of ISO 14001.
Reliability derived from 80 years of achievementSince it's foundation in 1924, Daikin Industries, Ltd. has constantly beendeveloping to become a global leader in an array of fields, such as airconditioning systems, refrigerants, fluorochemicals, electronics and hydraulicmachineries. In particular, Daikin holds the largest market share of bothresidential- and commercial-use air conditioning systems in Japan. It isthe world's sole manufacturer that combines research, development andmanufacturing of air conditioning systems, refrigerants and compressors.
CHINA
Daikin (China) InvestmentGuangzhou Branch
Daikin (China) InvestmentShanghai Branch
Daikin AirconditioningGermany
Daikin AirconditioningFrance
Daikin AirconditioningUK
Daikin IndustriesCzech Republic
Daikin AirconditioningSpain
Daikin AustraliaDaikin AirconditioningSingapore
Daikin Industries (Thailand)
ASIA/OCEANIA
Daikin AirconditioningItaly
Examples of installation
Ministry of Agriculture &Fisheries LaboratoryOmanApril 20027 VRV Plus
Al Nokhba Tower(Elite Residential Suites)KuwaitJune 200311 VRV Plus
Sanabel Tower HotelSaudi ArabiaJanuary 200175 VRV Plus
Awqaf TowerQatarJune 20048 VRV Plus
Contents
29.....Control Systems
42.....Water Chillers
28.....HRV
S P L I T T y pe A i r C o n di t i o n e r s
Air Cooled Split Type Air Conditioners
PACKAGEDAIR CONDITIONERS
The Intelligent Air Conditioning System
3
21
7
33
Osaka Head Office
Tokyo Head Office
Production Site
Overseas Affiliate
Sales Agent
DAIKINASAGLOBALCORPORATE CITIZEN
Osaka Head Office
Tokyo Head Office
Production Site
Overseas Affiliate
Sales Agent
FT60D
Note: Availability of the products shown in this catalog varies by country.
3 4
The Split System is the ideal air conditioning solution for one room oran area of your home. Daikin air conditioners lead the industry withtheir energy savings. Each indoor unit features silent operationfunction, bringing comfort in your living room or bedroom.Daikin now has a new D series. The simple and stylish design softlyharmonizes with your living space.
Wall-mounted type...............................5
Split type air conditioners
SPLIT Type Air Conditioners
Line up
Type
Function listFunction
Model Name
Wall-mountedtype
H/P 60 HzFTY-GA
Capacity class
17,100 20,5001.42 1.72
5.0 6.04,300
BtuRT
kWkcal 5,160
FT-GA C/O 50 Hz
FT-GA C/O 60 Hz
FT-D C/O 60 Hz
Wall-mounted typeFT50/60GA FTY50/60GA
Power-airflow dual flaps
Comfortableairflow
Comfortcontroloperation
Wide-angle louvers
Vertical auto-swing
Horizontal auto-swing
Auto fan speed
W I D EA N G L E
A U T O
Lifestyleconvenience
Healthy &clean
Timer
Worry free
Power airflow flap
Air-purifying filter with photocatalytic deodorizing function
Program dry function
Automatic operation
New powerful operation
Indoor unit On/Off switch
Air-purifying filter
Mold-proof air filter
Washable grille
Filter cleaning indicator
24-hour On/Off timer
Night set mode
Auto-restart after power failure
Self-diagnosis digital display
Anticorrosion treatment of outdoor heat exchanger fin
N E WN E W
S E L F
C L E A N
2 4
Wipe-Clean flat panel
5 6
Wall-mounted type5.0·6.0 kW
Air-Purifying Filter with Photocatalytic Deodorizing Function isable to remove both bacteria and viruses, in addition toeliminating mold and odors. It can be used for approximately3 years with appropriate maintenance.
High Energy SavingsDaikin air conditioners’ advanced technology allows themto achieve significant energy savings with a COP of 2.55even during periods of extended use.
Compact and Stylish Design
The compact and stylish design of Daikin unitsharmonizes with any interior decor. The innovativeflat panel of the new D series enhances this effectand also ensures optimum operation.
SPLIT Type Air Conditioners
FT-D Series
Wall-mounted type
Healthy and Clean
Unique features such as our Vertical auto-swing and Horizontal auto-swingwill keep your home wrapped in a cloud of air-conditioned comfort.
Compact and quietThe rounded contours of the compact, lightweight indoor unit allow it toharmonize smoothly with your interior decor, and an improved fan designmakes operating noise hardly noticeable.
Energy-savingUsing your air conditioner for extended periods of time is now a completelyaffordable luxury thanks to Daikin’s advanced energy-saving technology.
Notes : •*1:Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB. Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB. Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
Conversion rates
kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284 Conversion rates
kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284
The flap descends to blowwarm air directly downto the floor to quickly warmthe whole room.
The flap flattens out so thatcool air slides off to reachthe farthest corners of theroom.
Notes: •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB. Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB. Equivalent ref. piping: 5 m (Horizontal)(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB. Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
•*2:Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB. Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB. Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
Cooling *1 (2)Heating *2 (2)
5.8/5.0 6.5/5.6
19,800/17,1004,990/4,300
22,200/19,1005,590/4,800
1.65/1.42 1.85/1.59
6.3/6.0 7.19/7.10
21,500/20,5005,420/5,200
24,500/24,2006,180/6,100
1.79/1.71 2.04/2.02
2.903.37
1.87/1.852.492.95
2.44/2.46
FT50GAVAL FT60GAVALR50GVAL R60GVAL
1 phase, 220 V, 60 Hz
FTY50GAVAL FTY60GAVALRY50GVAL RY60GVAL
1 phase, 220 V, 60 Hz
—19.4 to 54
-10 to 1519.4 to 54
5.6/4.5 6.8/5.6
19,100/15,4004,800/3,900
23,200/19,1005,850/4,800
1.59/1.28 1.93/1.59
— —
——
——
— —
2.57—
—2.54—
—2.18/2.50 2.68/3.06 2.00/2.30 2.61/2.97
Wipe-CleanFlat Panel
Note: Availability of the products shown in this catalog varies by country.
7 8
Stores often feature the latest in designed decor. This refined beauty attractspeople.Meanwhile, offices have a functional beauty. This encourages those within towork hard and apply intelligence and passion to their tasks.In either situation, a certain elegance should fill the space because thinkingminds require high quality air conditioning. SkyAir by Daikin ensures acomfortable indoor environment. All over the world, stores, offices, and homesprefer the low operating noise, attractive design, complete comfort control,and other benefits brought by SkyAir.
Notes: •Specifications for RT, Btu and kW are based on the following conditions; Power supply: 60 Hz; Cooling: Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.•The values given for 2 HP to 6 HP are for the FHY(C) model and 8 HP to 20 HP are for the FD model. The values given for simultaneous operation system are for the FHYC model.•*1:FDYB and FDYM model operate for 20·25 (kW) class. •*2:FDYB and FDYM model operate for 20 (kW) class.
Packagedairconditioners
Capacity
Capacity
Outdoorunit
9 10
Air Cooled Split Type Air Conditioners
Wall Mounted TypeCeiling Suspended Type
Floor Standing TypeCeiling Mounted Cassette Corner Type
Ceiling Mounted Cassette Type Ceiling Mounted Built-in Type
Uni-directional discharge outlet isperfect for corner installation.A thin, 21.5 cm main bodyenables installation even in asmall ceiling overhead space.
FHK
FH(Y)B
FA(Y)
FV(Y)
Floor standing type units are easy toinstall and maintain; their slimness issuitable for installation in high-ceilingstores and offices.
Wall mounted type units featurethe lowest sound levels in theindustry and greatly upgradedcomfort, thanks to the high fanspeed mode.
With the use of simple ducts,discharge outlets can be locatedin a multitude of ways. Top prioritygiven to interior decor, built-intype units realize ideal air currentdistribution.
Quiet,decor-blending form and easyinstallation in new or old buildings.Multiple unit installations maintain aphysical uniformity that isaesthetically pleasing and make iteasier to plan ceiling lightingsystems and to design interiors.
Packaged Air Conditioners Duct Connection Series
FDB(G)FDYB FD(Y)FD(Y)M
FDMG
For details, please refer to P33-P40.
Low static pressure High static pressureMiddle static pressure
11 12
Air Cooled Split Type Air Conditioners—Specifications
Notes : •*1:Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
Notes : •*1:Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
Notes : •*1:Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
Notes : •*1:Nominal cooling capacities are based on the following conditions:(1) Return air temperature:27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature:29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
Notes : •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
•*2: Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
Model
Model
Heat Pump (60 Hz)
RT
kWkWHeating *2 (1)/(2)
Cooling *1 (1)
Heating *2 (1)
Cooling *1 (1)/(2)
Operation range(Outdoor temp.)
19.4 to 54-10 to 15
-5 to 54-10 to 15.5 -10 to 15
°CDB°CWBHeating
Cooling
Operation range(Outdoor temp.)
°CDB°CWBHeating
Cooling
Operation range(Outdoor temp.)
°CDB°CWBHeating
Cooling
kWHeating *2 (1)/(2)Cooling *1 (1)
Heating *2 (1)
Cooling *1 (1)/(2) kW
kWHeating *2 (1)/(2)Cooling *1 (1)
Heating *2 (1)
Cooling *1 (1)/(2) kW
19.4 to 54-10 to 15
-5 to 54-10 to 15.5
-5 to 54-10 to 15.5
Conversion rates
kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284
Conversion rates
kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284
(For specifications of duct connection series, please refer to P35-P40.)
•Branch piping kit is optionally available.Refrigerant piping uses terminal branching to facilitate installation
•An optional remote controller is required for one of the combination indoor units.•Optional remote controllers are a single item, and cannot operate the air conditioning individually. Indoor units should not therefore be installed in separate rooms.•If operating with optional wireless remote controllers, set one as the main unit and install a light receptor.
Precautions when selecting optional remote controller
Branch piping kit
Branch piping kit
*Typical combination
Twin Multi Application
Triple Multi Application Double Twin Multi Application
Note: This type of system does not allow individual control or independent operation ofindoor units. It is not the best choice for large rooms with partitions.
In a single-floor restaurant, for example, positioning 4 unitsat strategic locations achieves comfortable air flow thatreaches every inch of the room.
Indoor units include the super cassette type, duct connection low and middle static pressure type and ceiling suspended type.(Indoor units are limited to same capacity and type combination.)
In large interior spaces a single indoor unit may not be ableto provide uniform comfort. Installation of 2 to 4 units,distributed to consider sun light and human gatheringpatterns, can provide an effective solution.
Simultaneously operates 2 to 4 indoor units usinga single outdoor unit.
Installing multiple units iseconomical and ensures comfortLower cost of installation than for individual pair typeLess space needed for outdoor unitsEnhanced comfort from distributed indoor units
Air Cooled Split Type Air Conditioners—Specifications
3.78/4.40 4.77/6.00 6.00/6.70
2.542.14
2.832.39
2.932.38
3.55/3.90 4.52/5.15 5.53/5.60
Power comsumption
COP
Notes : •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
•*2: Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
Operation range(Outdoor temp.)
°CDB°CWBHeating
Cooling
kWHeating *2 (1)/(2)Cooling *1 (1)
Heating *2 (1)
Cooling *1 (1)/(2) kW
-5 to 54-10 to 15.5
Power comsumption
COP
Operation range(Outdoor temp.)
°CDB°CWBHeating
Cooling
kWHeating *2 (1)/(2)Cooling *1 (1)
Heating *2 (1)
Cooling *1 (1)/(2) kW
-5 to 54-10 to 15.5
2.3/1.9 3.2/2.6
2.6/2.4 3.6/3.4
2.6/2.4 3.6/3.4 4.6/4.3
2.3/1.9 3.2/2.6 4.1/3.6
Conversion rates
kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284
(For specifications of duct connection series, please refer to P35-P40.)
Notes : •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
•*2: Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)
FHYC71KVEX3FHYC50KVEX4
Btu/hkcal/h 23,300/22,900
76,800/75,70019,400/19,100
92,500/90,800
Heating capacity*2 (1)
kW 28.422.7
RT 8.16.4Btu/hkcal/h 24,400
77,50019,500
96,900
Model Indoor unit
Outdoor unit
Cooling capacity*1 (1)/(2)
Ceiling suspended type
Power supply
200 250
RY200KUY1
FHY100BVEX2
RY250KUY1
kW
RT
RT
FHY71BVEX3FHY50BVEX4
Btu/hkcal/h
Heating capacity*2 (1)
kW
Btu/hkcal/h
FHYC125KVEX2
FHYC60KVEX4
FHY125BVEX2
FHY60BVEX4
C ooling Only (50 Hz)
COP *1 (1)/(2)
COP *1 (1)/(2)
kW
°CDB -5 to 52
Power comsumption *1 (1)/(2)
Operation range (Outdoor temp.)
kW
°CDB
7.7/7.6 9.7/9.7
7.7/7.6 9.7/9.7
2.92/2.92 2.79/2.74
7.7/7.66.4/6.3
2.92/2.92 2.79/2.74
-5 to 52
Power comsumption *1 (1)/(2)
Operation range (Outdoor temp.)
7.7/7.6 9.7/9.7
3.492.92/2.92
3.092.79/2.74
6.5 9.2Power comsumption
COP
kWHeating *2 (1)Cooling *1 (1)/(2)Heating *2 (1)
Cooling *1 (1)/(2) kW
Power comsumption
COP
kWHeating *2 (1)Cooling *1 (1)/(2)
Heating *2 (1)
Cooling *1 (1)/(2) kW
Conversion rates
kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284
Notes : •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)
•*2: Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)
Notes : •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
•*2: Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
Notes : •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
FHYC125KVEX2
Power comsumption *1 (1)/(2)COP *1 (1)
Operation range (Outdoor temp.)
Power comsumption *1 (1)/(2)COP *1 (1)
Operation range (Outdoor temp.)
Power comsumption
Operation range(Outdoor temp.)
COP
Heating *2 (1)/(2)Cooling *1 (1)
Heating *2 (1)
Cooling *1 (1)/(2)
HeatingCooling °CDB
°CWB
kWkW 6.0/7.2 10.2/12.5
3.072.63
2.932.61
3.242.71
5.9/6.0 9.7/9.97.0/7.18.2/10.0Power comsumption
Operation range(Outdoor temp.)
COP
Heating *2 (1)/(2)Cooling *1 (1)
Heating *2 (1)
Cooling *1 (1)/(2)
HeatingCooling °CDB
°CWB
-10 to 15
-5 to 54 0 to 54-10 to 15
-5 to 54
5.7/6.92.77
8.2/10.02.71
10.2/12.52.61
Conversion rates
kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284
Conversion rates
kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284
(For specifications of duct connection series, please refer to P35-P40.)
Note: Availability of the products shown in this catalogue varies by country.
21 22
Rising energy and general building services running costs have led end users toexpect a truly complete and acceptable air conditioning system. It must be energyefficient, economic to run, easy to install, flexible, reliable and user friendly.Featuring inverter technology and individual control, the VRV systemrevolutionised building air conditioning the world over by meeting all theserequirements, and has been installed in various buildings throughout the world forthe last 20 years.
Line Up
Indoor Units.................................24VRV II Series...............................25
Note: • Specifications for RT, Btu and kW are based on the following conditions;Cooling : Indoor temp. of 27-°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
BtuRT 0.8 ton 1.0 ton 1.3 ton 1.6 ton 2.0 ton 2.6 ton 3.2 ton 4.0 ton 6.4 ton 8.0 ton
Slim Ceiling Mounted Duct FXDQ-NVE
Wall Mounted
Floor StandingFXAQ-MHV1FXLQ-MHV1
Wall Mounted
FXAQ-MHV1 FXLQ-MHV1
Wall Mounted Floor S tanding
FXUQ-MV1
New C eiling S uspendedC assette
*FXDQ-NVE: with a drain-up pump (750 mm lift) as a standard accessoryFXDQ-NVET: without a drain-up pump
FXDQ-NVET
Connection unit series (50 Hz only)
• Indoor units in the 63 class are not available for the above models.• Connection unit BEVQ-M is necessary for each indoor unit.
BEVQ-MVE
C onnec tion unit for indoor unit
H/P
H/P
H/P
H/P: Heat Pump Type
withdrain-up pumpwithoutdrain-up pump
Capacity
Capacity
Notes: • Specifications for RT and Btu are based on the following conditions;Cooling : Indoor temp. of 27-°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
Note: • Specifications for RT and Btu are based on the following conditions; Cooling : Indoor temp. of 27-°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
Note : 1. Optional models (-E type) feature components treated for heat and rust corrosion resistance, such as external panels, fan motor, and electric component box, in addition to the fins ofthe heat exchanger. These models are designed specifically for use in areas which are subject to salt damage and atmospheric pollution. Please contact Daikin for more information.
2. Specifications are based on the following conditions;•Cooling : (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35°CDB.
(*2) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 46°CDB.(*3) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35°CDB.(*4) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 46°CDB.
•Heating : (*5) Indoor temp. of 20°CDB, and outdoor temp. 7°CDB/6°CWB.•Sound level : (*4) Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation,
these values are normally somewhat higher as a result of ambient conditions.
Conversion rates
kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284
Conversion rates
kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284
Outdoor units (50Hz) Outdoor units (60Hz)
Heat Pump Type (50 Hz) Heat Pump Type (60 Hz)
26
Capacity
Note: • Specifications for RT, Btu and kW are based on the following conditions;Cooling : Indoor temp. of 27-°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
Note: • Specifications for RT, Btu and kW are based on the following conditions;Cooling : Indoor temp. of 27-°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
Note : 1. Optional models (-E type) feature components treated for heat and rust corrosion resistance, such as external panels, fan motor, and electric component box, in addition to the fins ofthe heat exchanger. These models are designed specifically for use in areas which are subject to salt damage and atmospheric pollution. Please contact Daikin for more information.
2. Specifications are based on the following conditions;•Cooling : (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35°CDB.
(*2) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 46°CDB.(*3) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35°CDB.(*4) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 46°CDB.
•Heating : (*5) Indoor temp. of 20°CDB, and outdoor temp. 7°CDB/6°CWB.•Sound level : (*4) Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation,
these values are normally somewhat higher as a result of ambient conditions.
27 28
Heat Reclaim Ventilation
VAM150FAVE VAM350FAVE
VAM500FAVE VAM1000FAVE
VAM1500FAVE VAM2000FAVE
HRV Remote Controller
Daikin's HRV recovers heat energy lost through ventilation and holdsdown room temperature changes caused by ventilation, therebymaintaining a comfortable and clean environment.The HRV is interlocked to Daikin's system, SkyAir and other airconditioning systems and automatically switches over ventilation mode,further increasing the effects of energy conservation.First-Class Compactness in the Industry has been achieved by employinga originally developed High Efficiency Paper (HEP) element, and using anoptimized fan and airflow passage design.First-Class Energy Conservation in the IndustryA total of 28% reduction of air conditioning load has been achievedthrough a combined use of total heat exchange mode, linked operationwith an air conditioner, and pre-heat/pre-cool control.
R emote C ontroller
The HRV creates a high-quality environmentby interlocking with the air conditioner
Indoor unit
Daikin air conditioner
LCD remote controllerfor indoor unit
• Operating mode signal• Filter cleaning signal• Failure detection signal
• ON/OFF signal• Cooling/Heating mode signal• Set temperature signal• Ventilation signal• Humidifier ON/OFF signal
HRV
• Coffee shop and restaurant • Dressmakingshop• Super market • Other variety shops• Office• Small and medium size office building• Large house• Amusement center
Shops
O f f i c e
HousingOthers
Cooling Only & Heat Pump
3 phase, 220 V, 60 HzPower supplyRSNY8KTALModel
Cooling capacity (*1)/(*2) Btu/h6.4/7.1
76,400/85,300
85,300
19,300/21,50022.4/25.07.1Heating capacity (*3) RT
RT
kWkcal/h
Btu/h
118.9/8.5Power comsumption kW
kW
2.272.52/2.94COP
Cooling (*1)/(*2)HeatingCooling (*1)/(*2)Heating
25.021,500kcal/h
kW
Notes: 1. Optional models (-E type) feature components treated for heat and rust corrosionresistance, such as external panels, fan motor, and electric component box, inaddition to the fins of the heat exchanger. Please contact Daikin for moreinformation.
RSNY8KTAL22.4kw(8HP)
Different capacity and different typeof indoor unit can be connected atthe capacity ratio of 50 to 100% ofthe outdoor unit, and up to 6 indoorunits can be connected withindividual control.
The individual control of the air conditioning system for 4–5 rooms can be realizedby more simple and lesser installation work.
Notes: Specifications are based on the following conditions;(1)Cooling : 27°CDB, 19.5°CWB, and outdoor temp. 35°CDB.(2)Cooling : 27°CDB, 19.0°CWB, and outdoor temp. 35°CDB.
• Heating : Indoor temp. of 20°CDB, of 7°CDB, 6°CWB.• Equivalent piping length : 7.5 m.• Level difference : 0 m.
2. Specifications are based on the following conditions;•Cooling: (*1) Indoor temp.: 27.0°CDB, 19.0°CWB, Outdoor temp.: 35.0°CDB
Note:• Specifications for RT and Btu are based on the following conditions; Cooling : Indoor temp. of 27-°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.
29 30
Individual Control Systems Centralized Control SystemsControl Systems Control Systems
Large liquid crystal screen displayscomplete operating status.Digital display lets you settemperature in 1°C units.Lets you individually program bytimer the respective times foroperation start and stop within amaximum of 72 hours.Equipped with a thermostat sensor inthe remote controller that makespossible more comfortable roomtemperature control.Enables you to select cool/heat/fanoperation mode with the indoorremote controller of your choicewithout using the cool/heat selector.
Constantly monitors malfunctions inthe system for 80 items, and isequipped with a "self-diagnosisfunction" that lets you know bymessage immediately when amalfunction occurs.Lets you carry out various fieldsettings by remote controller.
Wired remote controller (Optional)
Wired remote controller
The remote controller hascentralized its frequently usedoperation selectors andswitches (on/off, operationmode, temperature setting andairflow volume), making itselfsuitable for use in hotel roomsor conference rooms.
Signal receiver unit(Separate type)
Wireless remotecontroller
The concealed-type remote controller smartly fits into anight table or console panel in a hotel room.
Exposed type
Concealed type(For hotel use)
Wireless remote controller (Optional)
Simple remote controller (Optional)
The same operation modes and settings as with wired remote controllers arepossible.
• A light receiving unit for a ceiling-mounted cassette (double-flow, multi-flow) type,ceiling-suspended type and wall-mounted type is mounted into the indoor unit.
Signal receiver unit(Installed type)
Signal receiving unit can beinstalled on the panelex. Ceiling mounted cassette (multi-flow) type
Note : 1. Installation box for adaptor must be procured on site.
Central remote controller (Optional)64 groups (zones) of indoor units can becontrolled individually same as LCD Remote controller.Max.64 groups (128 indoor units controllable)Max. 128 groups (128 indoor units) are controllable by using 2 central remote controllers,which can control from 2 different places.Zone controlMalfunction code displayMax. wiring length 1,000 m (Total : 2,000 m)Combination with Unified ON/OFF controller, schedule timer and BMS systemAirflow volume and direction can be controlled individually for indoor units in each group operation.Ventilation volume and mode can be controlled for Heat Reclaim Ventilation (HRV).Up to 4 Operation/Stop pairs can be set per day by connecting a schedule timer.
Unified ON/OFF controller (Optional)16 groups of indoor units can be operatedsimultaneously/individually.Max. 16 groups (128 indoor units) controllable2 remote controllers can be used to control from 2 different places.Operating status indication (Normal operation, Alarm)Centralized control indicationMax. wiring length 1,000 m (Total : 2,000 m)Compact size casing (Thickness : 16 mm)Combination with Central Remote controller, Schedule timer and BMS system
Schedule timer (Optional)Max.128 indoor units can be operated asprogramed schedule.Max. 128 indoor units controllableWhen used in combination with a central remote controller, a maximum of 8 weekly schedulepatterns can be set, while the central controller can be used to select desired zones. Up to 4Operation/Stop pairs can be set per day.Max. 48 hours back up power supplyMax. wiring length 1,000 m (Total : 2,000 m)Compact size casing (Thickness : 16 mm)Combination with Central Remote controller, Unified ON/OFF controller and BMS system
Part name Model No. Function
Unification adaptor for computerized control DCS302A52
Interface between the central monitoring board and centralcontrol units. Combined with the central remote controller,this adaptor enables the central monitoring board tocentralize such functions as the on/off control, operationstatus monitoring, and normal/malfunction monitoring.(*1)
Interface adaptor for SkyAir series DTA102A52
Wiring adaptor for other air-conditioner DTA103A51
DTA107A55
Adaptors required to connect products other than those ofthe VRV System to the high-speed DIII-NETcommunication system adopted for the VRV System.
* To use any of the above optional controllers, an appropriate adaptor must beinstalled on the product unit to be controlled.
Central control adaptor kitFor UAT(Y)-K(A), FD-K
For SkyAir, FD(Y)M-FA, FDYB-KA, FDY-KAFVY(P)J-A, FXUQ-MH, FXLQ-MH
For air conditioners other than mentioned above.
DCS302C61
DCS301B61
DST301B61
Set back time clock (Optional)
Set back time clock
Connected to LCD wired remote controller(BRC type), this time clock can set 2 setsof on/off times in an increment of 30 minutes within a day. For each on/off setting atemperature setting is also possible.
31 32
Daikin's advanced air-conditioning control systemsControl Systems
Contact signal
Ai unit
Light/Fan
Daikin CentralAir ConditioningSystem
Localmonitoring& control
WatchDOGRemoteMulti-PC
Ethernet
Remote PC Sub PC
SecurityFire alarm
D -NET
D -NET
D -NETD -NET
Wiring adaptor required for connection withother equipment not compatible with D -NET
DAM602A51/52/53*2
Viainternet
HRV
VRV System
Centralized control system for easy provision of effective control andmonitoring of VRV system functionsFloor visual navigationGraphical reportRemote intelligent managerMulti-PC accessWatch dog function for remote error monitoringPower limit controlSliding temperature <optional (DAM101A51) unit required>Automatic heat/cool change-overECO modeTemperature limitationAir Conditioning Network Service System (Optional Maintenance Service)
Ethernet
Local Controller
Please contact Daikin for compatibility with BMS system
SecurityPower supply facility
Fire alarm
ElevatorPumpLighting...etc
BMS
HRV
VRV System
Integrated control systems that recognize the trend of open control systems
*1Air ConditioningNetwork Service System(Optional Maintenance Service)
Compatibility with BMS enhanced by utilizing the international communication standards,BACnet® or LONWORKS®.
XIF file for confirming of specifications of the units.Connectable up to 10 outdoor units and 64 indoor unit groups.
Conformance class 3 (ASHRAE 135–1995)Standard BACnet® Device B-ASC (ASHRAE 135–2001)BACnet® OPC server compatibilityBACnet®/IP over EthernetUp to 40 outdoor units and 256 indoor uit groups on one gateway. (optional adapter)
DMS504B51 Interface for use in LONWORKS®
DMS502A51 Interface for use in BACnet®
NewNew
Dio unit
Interfacing requirements vary depending on model, and some systems may not be suitable. Please contact your distributor for details.
Local dealers
I/F unit*5Automatic data transfer
Mainfunction informationby E-mail
INTERNET
*1. There are restrictions in applicable areas and release times, therefore please consult us separately for details.*2. Model name varies upon the system size.*3. BACnet® is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).*4. LONWORKS® is a registered trade mark of Echelon Corporation.*5. For an I/F unit, one of the following can be selected: L oc al C ontroller, intelligent touch Controller, or intelligent Manager II.*6. Ethernet is a registered trademark of Xerox Corporation.
ACC center
Maintenance services that boost profitsand customer satisfaction
Air ConditioningNetwork Service System
24 hour on-line diagnostic systemEnergy saving and extention of aircon operating lifeMaintenance management via A/C network service system reportsReliable service at shortest lead time
BACnet® LONWORKS®Interface for and
DMS502A51(Interface for use in BACnet®)
DMS504B51(Interface for use in LONWORKS®)
N e w F u n c t io n sN e w F u n c t io n s
• Features control and monitoring functions for centralA/C products and an Air Conditioning NetworkService function.
• Using an external contact via DIII-NET, monitors andcontrols equipment such as lighting, fans, orbuilding security systems.
NewNew
Color LCD touch panel icon displaySmall manageable sizeSimplified engineeringMulti language (English, French, Italian, German, Spanish and Chinese)Yearly scheduleP.P.D. (Power Proportinal Distribution function) (Optional)Auto heat/cool change-overTemperature limitationHistory of 500 actionsAir Conditioning Network Service System (Optional Maintenance Service)Simple Interlock Function
New communication functions in the user-friendly icon-based multilingualcontroller simplify centralized control of the VRV system.
Support for centralized control from elsewhereusing a PC with a Web browser (Optional)Sending of e-mail alerts to a specified addresswhen malfunctions occur (Optional)Built-in modem for connecting toAirnet Service System (Optional)
Built-in Ethernet port for connecting tothe Internet or an intranetManagement of facilities / equipmentother than A/C units(Compatible with Dio unit and Di unit)
Doubling of number of control pointsby adding a D -NET Plus Adapter (Optional)
ACC center• Air Conditioning Network Service System
Forced OFF from the fire alarm
Pi Port
• Connection to power consumptionmeter when using power proportionaldistribution function. (Optional)
DIII-NETPlus Adapter(option)
Number of indoor unit expanded from 64 to 128.
Indoor Unit
RS-232CControl pump,lighting
Monitoring of roomenter/exit sign
Simple Interlock Function
Public phone line
Air ConditioningNetwork Service Systemmodem for connections
• CSV output of powerproportional distributionresults (Optional)
PCMCIAFlashMemory
Mobile PhoneTrouble reports
Forced OFF contact input
HRV
Dio Unit
Di Unit
D -NET
NewFunction 6
NewFunction 1
Remote monitoring and control
NewFunction 5
NewFunction 3
NewFunction 2
NewFunction 4
NewFunction 6
NewFunction 1
NewFunction 3
NewFunction 5
NewFunction 3
NewFunction 2
NewFunction 4
NewFunction 6
NewFunction 7
NewFunction 7
NewFunction 1
NewFunction 3
NewFunction 5
NewFunction 3
NewFunction 2
NewFunction 4
NewFunction 1New
Function 1
NewFunction 2New
Function 2
NewFunction 3New
Function 3
NewFunction 4New
Function 4
NewFunction 5New
Function 5
NewFunction 6New
Function 6
NewFunction 7New
Function 7 Simple Interlock Function
N e w F u n c t io n sN e w F u n c t io n s
Trouble reports
DCS601C51
Unification adaptorfor computerized control
[DCS302A52]
Unified ON/OFF andstatus monitoring fromthe central monitoring panel
Upgrade
Upgrade
NewNew
Note: Availability of the products shown in this catalogue varies by country.
Note: •Specifications for RT, Btu and kW are based on the following conditions; Power supply: 60 Hz; Cooling: Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.•The values given for 2 HP to 3 HP are for the FDB model, 4 HP to 6 HP are for the FDM model and 8 HP to 20 HP are for the FD model.The values given for 30 HP are for the UAT model and based on the following conditions; Power supply: 50 Hz; Cooling: Indoor temp. of 27°C DB, 19.5°C WB, and outdoor temp. of 35.0°C DB.
33 34
Daikin’s duct connection type packaged air conditioners are the best choicefor stores and offices. By placing the air conditioner in the ceiling, the designand finish of all areas remain attractive and unblemished. With minimaloperating sound, people nearby are almost unaware of the unit’s presence.And simultaneous operation of 2 to 4 indoor units with a single outdoor unit ispossible. When indoor units are distributed taking sunlight and humanoccupation patterns into consideration, a comfortable air flow is effectivelyspread throughout the room.Air cooled packaged water chillers are also available.Such systems can easily meet all the air-conditioning requirements offactories and other large areas.
Air Cooled Packaged Air ConditionersDuct Connection Series....................................... 35Air Cooled Single Packaged Air Conditioners......41Air Cooled Packaged Water Chillers....................42
Line Up
Packaged air conditioners
PACKAGEDAIR CONDITIONERS
Type Model Name
Air cooledpackagedduct connectionseriesLow staticpressure type
Air cooledpackagedduct connectionseriesMiddle staticpressure type
C/O60 Hz
50 Hz
FDM H/P60 Hz
50 Hz
Air cooledpackagedduct connectionseriesHigh staticpressure type
C/O60 Hz
50 Hz
H/P60 Hz
50 Hz
UAT
UATY
Air cooledsingle packagedair conditionersRoof top type
C/O
C/O
50 Hz60 Hz
H/P 50 Hz60 Hz
Simultaneousoperationsystem
UWAAir cooledpackagedwater chillers 60 Hz
50 Hz
50 100 150 200 250 300 400 500 600 700kW 800
PACKAGEDAIR CONDITIONERS
WATER CHILLERS
Capacity
Type Model Name HP 2 2.5 3 4 5 6 7.5 10 15 20 30
Operation range(Outdoor temp.)
Operation range(Outdoor temp.)
35 36
Duct Connection Series Low Static Pressure Type
PACKAGEDAIR CONDITIONERS
Air Cooled Packaged Air Conditioners—FD(Y)B(G) Series Air Cooled Packaged Air Conditioners—FD(Y)M Series
Duct Connection Series Low Static Pressure TypePerfect for quiet, beautiful, living spaceslike condominiums and apartments,houses and hotels, and similar living areas
R emote C ontroller Outdoor Unit
Whisper QuietIndoor unit with the industry's lowest level of sound
HandySmall, lightweight and easy-to-install outdoor unit
DurableThe special acryl precoated fin (PE fin) for anti-corrosiontreatment on the outdoor unit heat exchanger ensuresgreater resistance against salt damage and atmosphericpollution than ever.
Easy to UseEasy to read LCD wired remote controller (Optionalaccessory for heat pump type) (FDYB only)
Duct Connection Series Middle Static Pressure TypeDuct Connection Series Middle Static Pressure TypeMain unit can be mountedin the ceiling, and air can bedelivered freely by duct.
DurableThe special acryl precoated fin (PE fin)for anti-corrosion treatment on theoutdoor unit heat exchanger ensuresgreater resistance against salt damageand atmospheric pollution than ever.
Easy to UseEasy to read LCD wired remotecontroller. (Optional accessory)(FDYM only)
Central controlMany options are available for use withlarge-scale and advanced-functioncentrally controlled systems.(FDYM only)
FDBG50AVEFDB50KVE
FDBG60/71AVEFDB60/71KVE
FDYB50KAVE FDYB60/71KAVE
Digital RemoteController
LCD WiredRemoteController (Only for Heat Pump)
RemoteController
For Cooling Only Type For Heat Pump Type
SignalReceiverUnit
Wireless Remote Controller
Cooling Only (50 Hz)
Cooling Only (60 Hz) Heat Pump (60 Hz)
Notes: •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
•*2: Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
• Shows net capacities. When cooling it is the value minus the heat of the indoor unit fan motor. When heating, the heat of the fan motor is added.
Notes: •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
•*2:Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
• Shows net capacities. When cooling it is the value minus the heat of the indoor unit fan motor. When heating, the heat of the fan motor is added.• For FDMG models, capacities show gross capacities which do not include a deduction for evaporator fan motor heat.
R emote C ontroller Outdoor Unit
Cooling*1 (2)Heating *2 (1)
Cooling *1 (2)Heating *2 (1)
FDMG71AV1 FDMG100/125AV1
Digital RemoteController
RemoteController
For FD(Y)M modelsFor FDMG models
Conversion rates
kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284 Conversion rates
kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284
37 38
PACKAGEDAIR CONDITIONERS
Air Cooled Packaged Air Conditioners—FD(Y) Series
Duct Connection Series High Static Pressure TypeDuct Connection Series High Static Pressure TypeRecommended for spacious and large-volume areas because ofits flexible installation. Suitable for large stores, factories, andother large areas, and for use with housing ducts in homes.
Highly Adaptable InstallationHigh static pressure and long piping enable flexibleinstallation and use wherever the unit is placed.
CompactSpace-saving outdoor unit also enables lateralconnection.
DurableHighly durable outdoor unit employs PE fins, resistssalt damage and atmospheric pollution.
Super QuietIndoor unit with the industry's lowest level of sound.
Central controlMany options are available for use with large-scaleand advanced-function centrally controlledsystems.
Y1: 3 phase, 380-415 V (4 wires), 50 HzPower Supply
ModelRY250KUY1X2
200 250 400 500
RY200KUY1X2RY250KUY1FDY20KAY1FDY15KAY1FDY10KAY1
Heat Pump (50 Hz)
Notes: •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
•*2: Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
Notes: •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
Outdoor unitFDY08KAY1RY200KUY1
Indoor unit
R emote C ontroller Outdoor Unit
°CDB
kWCOP *1 (1)/(2)
Operation range (Outdoor temp.)
Power comsumption *1 (1)/(2)
°CDB
kWCOP *1 (2)Operation range (Outdoor temp.)
Power comsumption *1 (2)/(3)
kWkWPower comsumption
Heating*2 (1)Cooling*1 (2)/(3)
COP Cooling*1 (1)/(2)Heating *2 (1)/(2)
0 to 54-10 to 15
7.7/9.4 9.7/11.9 15.3/18.8
3.52 3.17 3.39 3.05
6.6/6.72.88
9.3/9.52.79
13.2/13.42.84
18.6/19.02.73
19.4/23.8
Operation range(Outdoor temp.)
CoolingHeating
kWkWPower comsumption
°CDB°CWB
Heating*2 (1)/(2)Cooling*1 (2)/(3)
COP Cooling*1 (2)Heating *2 (1)
Conversion rates
kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284
Conversion rates
kcal/h = kW x 860Btu/h = kW x 3412RT = kW x 0.284
39 40
PACKAGEDAIR CONDITIONERS
Simultaneous Operation System—Twin, Triple & Double Twin Multi Application Operation
In large interior spaces a single indoor unit may not be able to provide uniform comfort. Installation of 2 to 4 units, distributed toconsider sun light and human gathering patterns, can provide an effective solution.
In a single-floor restaurant, for example, positioning 4 units at strategic locations achieves comfortable air flow that reachesevery inch of the room.
Simultaneously operates 2 to 4 indoor units usinga single outdoor unit.
Installing multiple units is economical and ensures comfort
Lower cost of installation than for individual pair typeLess space needed for outdoor unitsEnhanced comfort from distributed indoor units
Note: This type of system does not allow individual control or independent operation of indoor units. It is not the best choice for large rooms with partitions.
Notes: •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
•*2: Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
Notes: •*1: Nominal cooling capacities are based on the following conditions:(1) Return air temperature: 27°CDB, 19.5°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 27°CDB, 19.0°CWB, Outdoor temperature: 35°CDB Equivalent ref. piping: 5 m (Horizontal)(3) Return air temperature: 29°CDB, 19.0°CWB, Outdoor temperature: 46°CDB, 24°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
•*2: Nominal heating capacities are based on the following conditions:(1) Return air temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 5 m (Horizontal)(2) Return air temperature: 21°CDB, Outdoor temperature: 7°CDB, 6°CWB Equivalent ref. piping: 7.5 m (Horizontal) (SSA385/386)
°CDB
kWCOP *1 (1)/(2)Operation range (Outdoor temp.)
Power comsumption *1 (1)/(2)Operation range(Outdoor temp.)
Digital Remote Controller Remote Controller(Only for Cooling Only)
Cooling Only (50 Hz/60 Hz)
Notes: 1. The above data marked with *1 are rated in accordance with JIS C-9612. 27°CDB (80°FDB)/ 19.5°CWB (67°FWB) indoor temp. And 35°CDB (95°FDB) outdoor temp.2. The above data marked with *2 are rated in accordance with SSA-385/386, 29°CDB (84°FDB)/ 19°CWB (66°FWB) indoor temp. And 46°CDB (115°FDB) outdoor temp.3. The figures of *2 are reference value.4. Capacity (*1, 2) is gross capacity which does not include a deduction for evaporator fan motor heat.5. *3: EER conditions: 27°CDB (80°FDB) and 19.5°CWB (67°FWB) for indoor temp. 35°CDB (95°FDB) for outdoor temp.
Notes: 1. Cooling capacities marked with *1 are based on 27°CDB (80°FDB) 19.5°CWB (67°FWB) indoor temp. and 35°CDB (95°FDB) outdoor temp.2. Cooling capacities marked with *2 are based on 29°CDB (84°FDB) 19.0°CWB (66°FWB) indoor temp. and 46°CDB (115°FDB) outdoor temp.3. Heating capacities are based on 21°CDB for indoor temp. 7°CDB/6°CWB for outdoor temp.4. The figures of *2 is reference value.5. *3: EER Cooling conditions: 27°CDB (80°FDB) and 19.5°CWB (67°FWB) for indoor temp. 35°CDB (95°FDB) for outdoor temp.6. *4: EER Heating conditions: 20°CDB for indoor temp. 7°CDB/6°CWB for outdoor temp.
*1 Cooling capacity is based on the following conditions: Leaving chilled water temp. 6.7°C (44°F), entering water temp. 12.2°C (54°F) outdoor temp. 35°C (95°FDB).*2 Cooling capacity is based on the following conditions: Leaving chilled water temp. 6.7°C (44°F), entering water temp. 12.2°C (54°F) outdoor temp. 46.0°C (115°FDB).
Notes :
3 phase, 208-230 V, 60 HzPower supply
Model
USRTCooling capacity *1
UWA70JATJ
722,200212.0
60.0
kWBtu/h
USRTCooling capacity *2 653,100
191.0
54.2
UWA80JATJ UWA90JATJ
865,000 936,400253.0 274.0
72.0 78.0
746,400 845,200219.0 248.0
62.1 70.4
UWA108JATJ UWA122JATJ
1,107,000 1,262,000324.0 370.0
92.2 105.0
972,200 1,145,000285.0 335.0
81.0 95.3
kWBtu/h
3 phase, 208-230 V, 60 HzPower supply
R emote C ontroller
Roof Top TypeRoof Top TypeEasy to install on rooftop or veranda, requiring only ducting,power line and drain piping.In addition to its high efficiency, the scroll compressor is 10%lighter and 30% more compact than conventionalreciprocating compressors. This makes this series among theindustry's most lightweight and compact than previous models.Also, since the scroll compressor generates less vibration, thisseries has greatly improved its durability and achieved theindustry's lowest operation sound. (UAT(Y)-K Series)Efficient cross fin coils are used: the unique waffle louverfins*1 maximize heat exchange efficiency, while the Hi-XAcopper tube*2, featuring an inner spiral groove, fully exploitsrefrigerant turbulence to help increase heat exchangeefficiency. The result is substantial energy savings.U.S. PAT. *1; No.4,434,844 *2; No.4,480,684
Wide Operation Range:Operative high outdoor temperature.UWA37JAY1–109JAY1: 5 to 52°CUWA27JATJ, 37JATJ: 15 to 49°CUWA43JATJ–122JATJ: 5 to 49°CUWA120JY1–270JY1: 5 to 49°C
Equipped with a compact andpowerful semi-hermetically sealedreciprocating compressor.
Energy saving.
Capacity can be controlled in multiple steps from 3 to 7 steps to saveenergy.